期刊文献+
共找到16,797篇文章
< 1 2 250 >
每页显示 20 50 100
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
1
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
2
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
3
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 肺的静脉 导管脱离 Atrial 纤维性颤动 Transesophageal echocardiography 三维的 echocardiography
下载PDF
Real-time three-dimensional echocardiography predicts cardiotoxicity induced by postoperative chemotherapy in breast cancer patients 被引量:2
4
作者 Fang Zhou Lin Niu +2 位作者 Min Zhao Wei-Xing Ni Jian Liu 《World Journal of Clinical Cases》 SCIE 2020年第12期2542-2553,共12页
BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early... BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time. 展开更多
关键词 Atrial volume CHEMOTHERAPY Breast cancer Cardiac toxicity Real-time three-dimensional echocardiography ANTHRACYCLINES
下载PDF
Incremental value of three-dimensional and contrast echocardiography in the evaluation of endocardial fibroelastosis and multiple cardiovascular thrombi: A case report 被引量:1
5
作者 Li-Juan Sun Ying Li +2 位作者 Wei Qiao Jia-Hui Yu Wei-Dong Ren 《World Journal of Clinical Cases》 SCIE 2021年第14期3365-3371,共7页
BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac fu... BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk. 展开更多
关键词 Endocardial fibroelastosis three-dimensional echocardiography Contrast echocardiography THROMBOSIS Left ventricle Case report
下载PDF
Assessment of Atrial Septum Morphology by Live Three-dimensional Echocardiography
6
作者 方凌云 谢明星 +4 位作者 王新房 蒲朝霞 杨亚利 贺林 周小燕 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第6期687-690,共4页
To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics... To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneurysm, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols. 展开更多
关键词 live three-dimensional echocardiography atrial septal defects atrial septum
下载PDF
Evaluation of Biventricular Volume and Systolic Function in Children with Ventricular Septal Defect and Moderate to Severe Pulmonary Hypertension Using Real-Time Three-Dimensional Echocardiography
7
作者 Huan Zhou Jin Kang +5 位作者 Jun Gao Xiaoyuan Feng Li Zhou Xia Xiao Zhengliang Meng Chengwen Guo 《Congenital Heart Disease》 SCIE 2022年第6期697-707,共11页
Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE... Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH. 展开更多
关键词 Real-time three-dimensional echocardiography ventricular septal defect pulmonary hypertension CHILDREN
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Congenital Double Orifice Mitral Valve
8
作者 吕清 卢晓芳 +7 位作者 谢明星 王新房 王静 杨亚利 袁莉 贺林 刘夏天 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第5期625-628,共4页
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp... The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV. 展开更多
关键词 double orifice mitral valve echocardiography real-time three-dimensional
下载PDF
Clinical Value of Stereoscopic Three-dimensional Echocardiography in Assessment of Atrial Septal Defects: Feasibility and Efficiency 被引量:1
9
作者 王静 王新房 +3 位作者 谢明星 贺林 吕清 王蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第6期791-794,共4页
Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D... Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions. 展开更多
关键词 echocardiography stereoscopic vision real time three-dimension atrial septal defect OCCLUSION
下载PDF
Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography 被引量:1
10
作者 刘红云 邓又斌 +5 位作者 刘琨 李阳 汤乔颖 魏翔 昌盛 卢峡 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第5期765-769,共5页
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati... Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft. 展开更多
关键词 three-dimensional echocardiography speckle tracking imaging heart transplantation
下载PDF
Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair 被引量:1
11
作者 Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China, 2 Rush University Medical Center, Chicago, USA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期137-141,共5页
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information... Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair. 展开更多
关键词 echocardiography REAL-TIME transeophageal MITRAL VALVE REPAIR
下载PDF
Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Chronic Kidney Failure 被引量:1
12
作者 Yu-bo WANG Hui HUANG +4 位作者 Shan LIN Mei-jia HAO Lu-jiao HE Kun LIU Xiao-jun BI 《Current Medical Science》 SCIE CAS 2022年第4期895-901,共7页
Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional... Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional and three-dimensional transthoracic echocardiography was performed on 30 patients with CKF.The ejection fraction,mass and global peak longitudinal strain,global circumferential strain,global area strain,and global radial strain of the left ventricle were calculated.Results:The ejection fraction,mass and global peak longitudinal strain(GLS),global circumferential strain(GCS),global area strain(GAS),and global radial strain(GRS)in the CKF group were significantly lower than those in the control group.Simultaneously,the GLS,GCS,GAS and GRS were well correlated with the ejection fraction.For patients with normal ejection fraction in the CKF group,the GLS,GCS,GAS and GRS were lower than those in the control group,while the left ventricular mass was significantly higher in CKF patients than in the control group.For patients with hypertension in the CKF group,ejection fraction,GLS,GCS,GAS and GRS calculated using three-dimensional echocardiography were significantly lower than those in patients with normal blood pressure;however,the myocardial mass was higher.Conclusions:The parameters(GLS,GCS,GAS and GRS)calculated using three-dimensional speckle-tracking software were lower in the CKF group.Simultaneously,the left ventricular mass was higher in CFK patients than in the control group,thus showing that the myocardial contraction function was impaired and that myocardial remodeling had occurred. 展开更多
关键词 three-dimensional speckle-tracking echocardiography left ventricle ejection fraction STRAIN chronic kidney failure
下载PDF
Surgical Resection of Mitral Valve Papillary Fibroelastoma: A Robot-Assisted, Minimally Invasive Approach with Three-Dimensional Transesophageal Echocardiography Imaging 被引量:1
13
作者 Crystal R. Bonnichsen Harold M. Burkhart +1 位作者 Kyle W. Klarich Rakesh M. Suri 《World Journal of Cardiovascular Surgery》 2012年第2期10-13,共4页
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e... Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy. 展开更多
关键词 PAPILLARY FIBROELASTOMA ROBOTIC Surgery three-dimensional TRANSESOPHAGEAL echocardiography
下载PDF
Assessment of Papillary Fibroelastoma of the Semilunar Valves by Three-Dimensional Echocardiography
14
作者 Leonel Avendano-Pérez Nydia Avila-Vanzzini Nilda Espinola-Zavaleta 《World Journal of Cardiovascular Diseases》 2017年第12期429-434,共6页
Papillary fibroelastoma is an uncommon tumor. Recognitions of this tumor have been improved thanks to modern imaging advances, which have made more patients to be identified, but at the same time, the management of th... Papillary fibroelastoma is an uncommon tumor. Recognitions of this tumor have been improved thanks to modern imaging advances, which have made more patients to be identified, but at the same time, the management of this disease is still controversial. There aren’t enough studies to basic clinical actions. We present 2 interesting cases involving the semilunar valves. The purpose of presenting these cases is to review this rare disease and the superiority of the three-dimensional echocardiography in their diagnosis. 展开更多
关键词 Heart Tumor Papillary Fibroelastoma Pulmonary Valve Aortic Valve echocardiography
下载PDF
Dynamic Characteristic Mechanism of Atrial Septal Defect Using Real-Time Three-Dimensional Echocardiography and Evaluation of Right Ventricular Functions 被引量:6
15
作者 沙仁高娃 张军 +1 位作者 秦川 吕清 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第1期140-147,共8页
The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynami... The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane(LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group(n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method(4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume(P〈0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated(P〈0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group(P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group(P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group(P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant(P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group(P=0.031). The a RVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group(P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease. 展开更多
关键词 ultrasonic cardiography real-time three-dimension atrial septal defect tricuspid annulus right atrium
下载PDF
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
16
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 实时三维超声波心动描记术 定量法 左心室胞块 心血管疾病
下载PDF
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
17
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography(RT-3DE)and left atrial trackin... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography(RT-3DE)and left atrial tracking(LAT).Methods One hundred and thirty-three patients with essential hypertension were divided into four groups according to criteria proposed by Ganau et al:36 patients in normal pattern group(I),34 patients in concentric remodelling pattern group(II),33 patients in concentric hypertrophy pattern group(III),and 30patients in eccentric hypertrophy pattern group(IV).Thirty-two healthy volunteers were enrolled in this study.RT-3DE and LAT were used to obtain the volume-time and emptying fraction curves,and then the maximal volume,minimal volume,stroke volume,presystolic volume,ejection fraction,systolic filling rate,early diastolic emptying rate and late diastolic emptying rate of the left atrium were measured.Conduit volume and passive emptying volume of the left atrium were calculated.Results Left atrial indexes,conduit volume,passive emptying volume,and early diastolic emptying rate decreased,while the other indices increased in the group I compared with the control group(all P<0.05).Compared with the control group,I and II groups,the left atrial volume parameters manifested change in the group III and group IV(all P<0.01).Left atrial ejection fraction measured by RT-3DE or LAT,and late diastolic emptying rate were lower in the group IV compared with the group III(all P<0.05).There was no difference in left atrial conduit volume,passive emptying volume,and early diastolic left atrial emptying rate between the group II and group I(all P>0.05).There was a positive correlation between RT-3DE and LAT in evaluating left atrial function.Conclusions Left atrial booster pump function decreases in the eccentric hypertrophy pattern.Left atrial conduit function is unchanged in the normal pattern and the concentric remodelling pattern groups.RT-3DE and LAT technology can be used for quantitative evaluation of left atrial volume and function. 展开更多
关键词 高血压患者 超声心动图 几何模型 原发性 心房 跟踪 三维 实时
下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
18
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 心肌灌注损伤 超声波心动描记术 空间定量 临床
下载PDF
Application of three-dimensional speckle tracking technique in measuring left ventricular myocardial function in patients with diabetes
19
作者 Zheng Li Ying Qian +1 位作者 Chun-Yun Fan Yong Huang 《World Journal of Diabetes》 SCIE 2024年第4期783-792,共10页
BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use... BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM. 展开更多
关键词 Diabetes mellitus Left ventricular systolic dysfunction three-dimensional speckle tracking echocardiography Meta analysis
下载PDF
An initial study on left ventricular diastolic function in patients with hypertrophy cardiomyopathy using single-beat, real-time, three-dimensional echocardiography
20
作者 Bei Zhao Juan Li +2 位作者 Yong Xu Hong-Wei Zhu Guang Zhi 《Journal of Geriatric Cardiology》 CAS CSCD 2012年第3期220-227,共8页
ObjectivesTo 由使用单个敲击的、即时、三维的 echocardiography (RT-3DE ) 与 hypertrophic 心肌症(HCM ) 在病人估计地区性的心脏舒张的功能 .MethodsSixty -- 有在和五十匹配年龄、匹配性的正常控制的湾穴节奏的 HCM 的五个病人被... ObjectivesTo 由使用单个敲击的、即时、三维的 echocardiography (RT-3DE ) 与 hypertrophic 心肌症(HCM ) 在病人估计地区性的心脏舒张的功能 .MethodsSixty -- 有在和五十匹配年龄、匹配性的正常控制的湾穴节奏的 HCM 的五个病人被二维的 echocardiography (2DE ) 和 RT-3DE 学习。参数由包括的 RT-3DE 分析了:留给室( LV )体积,左室的喷射部分( LVEF ),结束心脏舒张的球状索引( EDSI ),心脏舒张的 dyssynchrony 索引( DDI ),分散结束扩张( DISPED ),并且由 RT-3DE 使 17 部分卷时间 curves.ResultsEvaluated 正常化, LVEF 与 2DE 相比是稍微更低的( 63.2 &#x000b1 ;6.8% 对 59.1 &#x000b1;6.4% , P &#x0003c;0.0001 ) 。正常题目为所有 LV 片断有相对一致的容量的曲线。在 HCM 病人,部分容量的曲线是 dyssynchronous。在结束扩张的增加的 DDI 和 DISPED 与 HCM 在病人被观察(9.95 &#x000b1;3.75, 41.76 &#x000b1;17.19, P &#x0003c;0.0001 ) ,并且并非所有反常容量的片断与 HCM 发生在 hypertrophic regions.ConclusionsPatients 在扩张阶段,和这现出症状之前的潜的损害介绍了地区性的心脏舒张的 dyssynchrony 能被单个敲击的 RT-3DE 认出。 展开更多
关键词 超声心动图 心肌病 患者 厚型 三维 时间曲线 体积曲线 正常人
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部