This paper summarizes a few spatial statistical analysis methods for to measuring spatial autocorrelation and spatial association, discusses the criteria for the identification of spatial association by the use of glo...This paper summarizes a few spatial statistical analysis methods for to measuring spatial autocorrelation and spatial association, discusses the criteria for the identification of spatial association by the use of global Moran Coefficient, Local Moran and Local Geary. Furthermore, a user-friendly statistical module, combining spatial statistical analysis methods with GIS visual techniques, is developed in Arcview using Avenue. An example is also given to show the usefulness of this module in identifying and quantifying the underlying spatial association patterns between economic units.展开更多
With increasing awareness of energy conservation and environmental protection, the Organic Rankine Cycle (ORC) system has gained significant attention. This technology enables the recovery of industrial waste heat, wa...With increasing awareness of energy conservation and environmental protection, the Organic Rankine Cycle (ORC) system has gained significant attention. This technology enables the recovery of industrial waste heat, waste incineration heat, and renewable energy sources such as geothermal heat, biomass energy, and solar energy at lower temperatures. However, the low-grade heat source utilized in ORC systems faces a challenge to achieving high power generation efficiency and output power. Therefore, enhancing the power generation capacity of ORC systems is a key research focus in this field. An entranced heat exchanger ORC system with the screw expander driven by the low-temperature heat source is established to investigate the relevant performance. Hot water temperature from 77°C to 132°C is adopted for performance analysis, while the environmental temperature is approximately 25°C. Refrigerant R245fa is selected as the working fluid, and the screw expander is employed for power generation. It is worth noting that the entranced heat exchanger ORC system has significant potential for low-temperature heat recovery. Experimental results indicate that the maximum power output is 12.83 kW, which is obtained at around 105°C hot water inlet temperature. Correspondingly, the average power output remains 11.75 kW, revealing the system’s high stability for power generation. The implementation of a plate heat exchanger for enhanced heat transfer has enabled a 50% reduction in system size compared to traditional shell-tube type ORC systems. Besides, economic calculations demonstrate substantial benefits associated with the ORC system. The calculations indicate an internal benefit of 560,000 RMB/year, accompanied by notable external benefits such as an energy saving and emission reduction potential of up to 784 t CO2 per year. Moreover, the payback period is 2.23 years. It shows a remarkable improvement in terms of performance and excellent economic benefits. As a result, the novel ORC presents a promising alternative for low-grade heat utilization as compared to conventional small-scale ORC systems.展开更多
In the paper the Czech toll system and its future are presented. E-toll Czech project: Facts and Figures (today) are included and the next steps in the process of developing microwave infrastructure are mentioned. ...In the paper the Czech toll system and its future are presented. E-toll Czech project: Facts and Figures (today) are included and the next steps in the process of developing microwave infrastructure are mentioned. In the event of possible system extension of the roads of the 1st, 2rid and 3rd class (ca 55,000 km), the satellite technology will be used. The feasibility of such a combination of these two technologies, microwave and satellite, is subject to the compatibility of both systems in terms of the control equipment. For the microwave toll system, economic analyses according to EU directives were prepared for the Czech Ministry of Transport. Special attention is paid to the problems of traffic congestion, noise and damage to the environment, on the basis of the "user pays" and "polluter pays" according to the Eurovignette Directive principles. A complete survey of the EU toll system is included in the list of information sources.展开更多
文摘This paper summarizes a few spatial statistical analysis methods for to measuring spatial autocorrelation and spatial association, discusses the criteria for the identification of spatial association by the use of global Moran Coefficient, Local Moran and Local Geary. Furthermore, a user-friendly statistical module, combining spatial statistical analysis methods with GIS visual techniques, is developed in Arcview using Avenue. An example is also given to show the usefulness of this module in identifying and quantifying the underlying spatial association patterns between economic units.
文摘With increasing awareness of energy conservation and environmental protection, the Organic Rankine Cycle (ORC) system has gained significant attention. This technology enables the recovery of industrial waste heat, waste incineration heat, and renewable energy sources such as geothermal heat, biomass energy, and solar energy at lower temperatures. However, the low-grade heat source utilized in ORC systems faces a challenge to achieving high power generation efficiency and output power. Therefore, enhancing the power generation capacity of ORC systems is a key research focus in this field. An entranced heat exchanger ORC system with the screw expander driven by the low-temperature heat source is established to investigate the relevant performance. Hot water temperature from 77°C to 132°C is adopted for performance analysis, while the environmental temperature is approximately 25°C. Refrigerant R245fa is selected as the working fluid, and the screw expander is employed for power generation. It is worth noting that the entranced heat exchanger ORC system has significant potential for low-temperature heat recovery. Experimental results indicate that the maximum power output is 12.83 kW, which is obtained at around 105°C hot water inlet temperature. Correspondingly, the average power output remains 11.75 kW, revealing the system’s high stability for power generation. The implementation of a plate heat exchanger for enhanced heat transfer has enabled a 50% reduction in system size compared to traditional shell-tube type ORC systems. Besides, economic calculations demonstrate substantial benefits associated with the ORC system. The calculations indicate an internal benefit of 560,000 RMB/year, accompanied by notable external benefits such as an energy saving and emission reduction potential of up to 784 t CO2 per year. Moreover, the payback period is 2.23 years. It shows a remarkable improvement in terms of performance and excellent economic benefits. As a result, the novel ORC presents a promising alternative for low-grade heat utilization as compared to conventional small-scale ORC systems.
文摘In the paper the Czech toll system and its future are presented. E-toll Czech project: Facts and Figures (today) are included and the next steps in the process of developing microwave infrastructure are mentioned. In the event of possible system extension of the roads of the 1st, 2rid and 3rd class (ca 55,000 km), the satellite technology will be used. The feasibility of such a combination of these two technologies, microwave and satellite, is subject to the compatibility of both systems in terms of the control equipment. For the microwave toll system, economic analyses according to EU directives were prepared for the Czech Ministry of Transport. Special attention is paid to the problems of traffic congestion, noise and damage to the environment, on the basis of the "user pays" and "polluter pays" according to the Eurovignette Directive principles. A complete survey of the EU toll system is included in the list of information sources.