The flow field in the ejector-diffuser system and its optimal operation condition are hardly complicated due to the complicated turbulent mixing, compressibility effects and even flow unsteadiness which are generated ...The flow field in the ejector-diffuser system and its optimal operation condition are hardly complicated due to the complicated turbulent mixing, compressibility effects and even flow unsteadiness which are generated inside the ejector- diffuser system. This paper aims at the improvement in ejector-diffuser system by focusing attention on entrainment ratio and pressure recovery. Several mixing guide vanes were installed at the inlet of the secondary stream for the purpose of the performance improvement of the ejector system. A Computational Fluid Dynamics (CFD) method based on Fluent has been applied to simulate the supersonic flows and shock waves inside the ejector. A finite volume scheme and density-based solver with coupled scheme were applied in the computational process. Standard k-ω turbulent model, implicit formulations were used considering the accuracy and stability. Previous experimental results showed that more flow vortexes were generated and more vertical flow was introduced into the stream under a mixing guide vane influence. Besides these effects on the secondary stream, the mixing guide vane effects on the shock system of the primary stream were also investigated in this paper. Optimal analysis results of the mixing guide vane effects were also carried out in detail in terms of the positions, lengths and numbers to achieve the best operation condition. The comparison of ejector performance with and without the mixing guide vane was obtained. The ejector-diffuser system performance is discussed in terms of the entrainment ratio, pressure recovery as well as total pressure loss.展开更多
The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compres...The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compressibility effects and even flow unsteadiness which are generated around the nozzle extent.In the present study,the primary stream nozzle was redesigned using convergent nozzle to activate the shear actions between the primary and secondary streams,by means of longitudinal vortices generated between the Chevron lobes.Exactly same geometrical model of ejector-diffuser system was created to validate the results of experimental data.The operation characteristics of the ejector system were compared between Chevron nozzle and conventional convergent nozzle for the primary stream.A CFD method has been applied to simulate the supersonic flows and shock waves inside the ejector.It is observed that the flow structure and shock system were changed and primary numerical analysis results show that the Chevron nozzle achieve a positive effect on the supersonic ejector-diffuser system performance.The ejector with Chevron nozzle can entrain more secondary stream with less primary stream mass flow rate.展开更多
文摘The flow field in the ejector-diffuser system and its optimal operation condition are hardly complicated due to the complicated turbulent mixing, compressibility effects and even flow unsteadiness which are generated inside the ejector- diffuser system. This paper aims at the improvement in ejector-diffuser system by focusing attention on entrainment ratio and pressure recovery. Several mixing guide vanes were installed at the inlet of the secondary stream for the purpose of the performance improvement of the ejector system. A Computational Fluid Dynamics (CFD) method based on Fluent has been applied to simulate the supersonic flows and shock waves inside the ejector. A finite volume scheme and density-based solver with coupled scheme were applied in the computational process. Standard k-ω turbulent model, implicit formulations were used considering the accuracy and stability. Previous experimental results showed that more flow vortexes were generated and more vertical flow was introduced into the stream under a mixing guide vane influence. Besides these effects on the secondary stream, the mixing guide vane effects on the shock system of the primary stream were also investigated in this paper. Optimal analysis results of the mixing guide vane effects were also carried out in detail in terms of the positions, lengths and numbers to achieve the best operation condition. The comparison of ejector performance with and without the mixing guide vane was obtained. The ejector-diffuser system performance is discussed in terms of the entrainment ratio, pressure recovery as well as total pressure loss.
文摘The supersonic nozzle is the most important device of an ejector-diffuser system.The best operation condition and optimal structure of supersonic nozzle are hardly known due to the complicated turbulent mixing,compressibility effects and even flow unsteadiness which are generated around the nozzle extent.In the present study,the primary stream nozzle was redesigned using convergent nozzle to activate the shear actions between the primary and secondary streams,by means of longitudinal vortices generated between the Chevron lobes.Exactly same geometrical model of ejector-diffuser system was created to validate the results of experimental data.The operation characteristics of the ejector system were compared between Chevron nozzle and conventional convergent nozzle for the primary stream.A CFD method has been applied to simulate the supersonic flows and shock waves inside the ejector.It is observed that the flow structure and shock system were changed and primary numerical analysis results show that the Chevron nozzle achieve a positive effect on the supersonic ejector-diffuser system performance.The ejector with Chevron nozzle can entrain more secondary stream with less primary stream mass flow rate.