Fractal Characteristics and Fractal Dimension Measurement on Broken Surfaces of Aluminum Electric Porcelain 被引量:5
1
作者 杨志远 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第1期37-41,共5页
The characteristics of broken surfaces were r esearched by a scanning electron microscope (SEM) and a reflection microscope, a nd the fractal dimensions of broken surfaces were measured by the Slit Island me thod. Th... The characteristics of broken surfaces were r esearched by a scanning electron microscope (SEM) and a reflection microscope, a nd the fractal dimensions of broken surfaces were measured by the Slit Island me thod. The experimental results indicate that the broken surface of aluminum elec tric porcelain is a fractal body in statistics, and the fractal dimensions of br oken surfaces are different with the different amplification multiple value.In a ll of measured fractal dimensions,both of values measured in 100× under reflect ion microscope and in 500× under SEM are maximum, whereas the values measur ed in 63× under reflection microscope and in 2000× under SEM are obviously min imum. The fractal dimensions of broken surfaces are also affected by the degrees of gray comparison and the kinds of measuring methods. The relationships betwee n the fractal dimensions of broken surfaces and porcelain bend strengths are tha t they are in positive correlation on the low multiples and in negative correlat ion on the high multiples. 展开更多
关键词 broken surface fractal dimension Slit Island m ethod electric porcelain
下载PDF
Experimental and analytical studies on multiple tuned mass dampers for seismic protection of porcelain electrical equipment 被引量:9
2
作者 Bai Wen Dai Junwu +2 位作者 Zhou Huimeng Yang Yongqiang Ning Xiaoqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第4期803-813,共11页
Porcelain electrical equipment (PEE), such as current transformers, is critical to power supply systems, but its seismic performance during past earthquakes has not been satisfactory. This paper studies the seismic ... Porcelain electrical equipment (PEE), such as current transformers, is critical to power supply systems, but its seismic performance during past earthquakes has not been satisfactory. This paper studies the seismic performance of two typical types of PEE and proposes a damping method for PEE based on multiple tuned mass dampers (MTMD). An MTMD damping device involving three mass units, named a triple tuned mass damper (TTMD), is designed and manufactured. Through shake table tests and finite element analysis, the dynamic characteristics of the PEE are studied and the effectiveness of the MTMD damping method is verified. The adverse influence of MTMD redundant mass to damping efficiency is studied and relevant equations are derived. MTMD robustness is verified through adjusting TTMD control frequencies. The damping effectiveness of TTMD, when the peak ground acceleration far exceeds the design value, is studied. Both shake table tests and finite element analysis indicate that MTMD is effective and robust in attenuating PEE seismic responses. TTMD remains effective when the PGA far exceeds the design value and when control deviations are considered. 展开更多
关键词 current transformer DAMPING porcelain electrical equipment finite element analysis multiple tuned massdampers shake table test