The exergy analysis of an electric vehicle heat pump air conditioning system(HPACS) with battery thermal management system was carried out by studying the exergy loss of each component. The results indicate that the c...The exergy analysis of an electric vehicle heat pump air conditioning system(HPACS) with battery thermal management system was carried out by studying the exergy loss of each component. The results indicate that the compressor is the main source of system exergy loss in all operation conditions. The exergy loss distribution of HPACS is almost the same when the battery thermal management system integrated into the HPACS in cabin and battery mixed cooling mode and the system exergy loss was linearly related to the compressor speed in cooling modes. The performance of the HPACS is better than that of the positive temperature coefficient(PTC) heater in cabin heating mode. The degree of exergy efficiency improvement of the alternative mode was discussed at all operation conditions in cabin heating mode. The results indicate that the optimization effect using the electric vehicle HPACS to replace the PTC heater is obvious at lower compressor speed, surrounding temperature and internal condenser air flow rate.展开更多
The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of re...The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.展开更多
Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with r...Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with refrigerant injection.During the start-up stage of EV in winter,the inlet air temperature of the in-car condenser is the same as the ambient temperature.At this situation,the performance and control strategy of the heat pump require special attention.In the present study,a series of experiments were carried out on the heating performance of the Refrigerant Injection Heat Pump(RIHP)system in start-up stage of EV,at the ambient temperature from–20℃ to–5℃.The effects of compressor speed and injected refrigerant state on the heating performance of the system were discussed in depth.According to the results,the control strategies during start-up stage have been discussed in the end of the article.The study provides a practical control strategy for the RIHP system during the start-up stage of electric vehicles,helping to efficiently operate electric vehicles in cold regions.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The...An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.展开更多
The relationship among the hydrogen storage properties, cycling characteristics and thermal parameters of the metal hydride air conditioning systems was investigated. Based on a new alloy selection model, three pairs ...The relationship among the hydrogen storage properties, cycling characteristics and thermal parameters of the metal hydride air conditioning systems was investigated. Based on a new alloy selection model, three pairs of hydrogen storage alloys, LaNi_ 4.4 Mn_ 0.26 Al_ 0.34 / La_ 0.6 Nd_ 0.4 Ni_ 4.8 Mn_ 0.2 Cu_ 0.1 ,LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Nd_ 0.4 Ni_ 4.8 Mn_ 0.2 Cu_ 0.1 and LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Y_ 0.4 Ni_ 4.8 Mn_ 0.2 , were selected as the working materials for the metal hydride air conditioning system. Studies on the factors affecting the COP of the system showed that higher COP and available hydrogen content need the proper operating temperature and cycling time,large hydrogen storage capacity, flat plateau and small hysterisis of hydrogen alloys, proper original input hydrogen content and mass ratio of the pair of alloys. It also needs small weight, heat capacity and good heat conductivity of the reaction beds. An experimental metal hydride air-conditioning system was established by using LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Y_ 0.4 Ni_ 4.8 Mn_ 0.2 alloys as the working materials, which showed that under the operating temperature of 180℃/40℃, a low temperature of 13℃ was reached, with COP =0.38 and W_ net =0.09 kW/kg.展开更多
Policies and initiatives promoting carbon neutrality in the Nordic heating and transport systems are presented. The focus within heating systems is the promotion of HPs (heat pumps) while the focus within transport ...Policies and initiatives promoting carbon neutrality in the Nordic heating and transport systems are presented. The focus within heating systems is the promotion of HPs (heat pumps) while the focus within transport systems is initiatives regarding EVs (electric vehicles). It is found that the conversion to HPs in the Nordic region relies on both private economic and national economic incentives. Initiatives toward carbon neutrality in the transport system are mostly concentrated on research, development and demonstration for deployment of a large number of EVs. All Nordic countries have plans for the future heating and transport systems with the ambition of realizing carbon neutrality.展开更多
The air conditioning systems in electric city buses usually operate in rapidly changing ambient conditions and are more likely to suffer from mechanical faults. Although many fault detection and diagnosis (FDD) method...The air conditioning systems in electric city buses usually operate in rapidly changing ambient conditions and are more likely to suffer from mechanical faults. Although many fault detection and diagnosis (FDD) methods have been developed for building air conditioning systems, they are difficult to be applied to bus air conditioners since its operation is highly dynamic and fault-free data are usually unavailable. Therefore, this paper proposes an FDD method for electric bus air conditioners to tackle the above issues. First, the method identifies faults in an unsupervised manner by comparing selected features among a group of peer systems. Then, considering the features are influenced by the operating conditions, Gaussian process regression (GPR) models are established to find the relationships between each feature and its influential parameters. The probabilistic nature of the GPR is used to differentiate predictions with large uncertainty, which are then excluded from FDD. In this way, robustness of the method is evidently improved. Finally, fault indexes are defined to detect and diagnose mechanical faults. We applied the method to a group of air conditioners in a city bus fleet. Results showed that it can effectively identify refrigerant undercharge and indoor and outdoor fan problems with low false positive/genitive rates. Also, the method is highly robust and not sensitive to the faulty systems in the bus fleet.展开更多
文摘The exergy analysis of an electric vehicle heat pump air conditioning system(HPACS) with battery thermal management system was carried out by studying the exergy loss of each component. The results indicate that the compressor is the main source of system exergy loss in all operation conditions. The exergy loss distribution of HPACS is almost the same when the battery thermal management system integrated into the HPACS in cabin and battery mixed cooling mode and the system exergy loss was linearly related to the compressor speed in cooling modes. The performance of the HPACS is better than that of the positive temperature coefficient(PTC) heater in cabin heating mode. The degree of exergy efficiency improvement of the alternative mode was discussed at all operation conditions in cabin heating mode. The results indicate that the optimization effect using the electric vehicle HPACS to replace the PTC heater is obvious at lower compressor speed, surrounding temperature and internal condenser air flow rate.
基金supported by The Open Project Program of State Key Laboratory of Fire Science (No. HZ2018-KF03)Shanghai Sailing Program (No. 18YF1417900)Huaqiao University Scientific Research Foundation (No. 16BS801)
文摘The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.
基金support by the National Natural Science Foundation of China(No.51576203)。
文摘Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with refrigerant injection.During the start-up stage of EV in winter,the inlet air temperature of the in-car condenser is the same as the ambient temperature.At this situation,the performance and control strategy of the heat pump require special attention.In the present study,a series of experiments were carried out on the heating performance of the Refrigerant Injection Heat Pump(RIHP)system in start-up stage of EV,at the ambient temperature from–20℃ to–5℃.The effects of compressor speed and injected refrigerant state on the heating performance of the system were discussed in depth.According to the results,the control strategies during start-up stage have been discussed in the end of the article.The study provides a practical control strategy for the RIHP system during the start-up stage of electric vehicles,helping to efficiently operate electric vehicles in cold regions.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
基金supported by the National Key Research and Development Program of China(No.2016YFB0601602)National Natural Science Foundation of China(No.51676199)
文摘An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.
基金The Natural Science Foundation of China (50266063) .
文摘The relationship among the hydrogen storage properties, cycling characteristics and thermal parameters of the metal hydride air conditioning systems was investigated. Based on a new alloy selection model, three pairs of hydrogen storage alloys, LaNi_ 4.4 Mn_ 0.26 Al_ 0.34 / La_ 0.6 Nd_ 0.4 Ni_ 4.8 Mn_ 0.2 Cu_ 0.1 ,LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Nd_ 0.4 Ni_ 4.8 Mn_ 0.2 Cu_ 0.1 and LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Y_ 0.4 Ni_ 4.8 Mn_ 0.2 , were selected as the working materials for the metal hydride air conditioning system. Studies on the factors affecting the COP of the system showed that higher COP and available hydrogen content need the proper operating temperature and cycling time,large hydrogen storage capacity, flat plateau and small hysterisis of hydrogen alloys, proper original input hydrogen content and mass ratio of the pair of alloys. It also needs small weight, heat capacity and good heat conductivity of the reaction beds. An experimental metal hydride air-conditioning system was established by using LaNi_ 4.61 Mn_ 0.26 Al_ 0.13 /La_ 0.6 Y_ 0.4 Ni_ 4.8 Mn_ 0.2 alloys as the working materials, which showed that under the operating temperature of 180℃/40℃, a low temperature of 13℃ was reached, with COP =0.38 and W_ net =0.09 kW/kg.
文摘Policies and initiatives promoting carbon neutrality in the Nordic heating and transport systems are presented. The focus within heating systems is the promotion of HPs (heat pumps) while the focus within transport systems is initiatives regarding EVs (electric vehicles). It is found that the conversion to HPs in the Nordic region relies on both private economic and national economic incentives. Initiatives toward carbon neutrality in the transport system are mostly concentrated on research, development and demonstration for deployment of a large number of EVs. All Nordic countries have plans for the future heating and transport systems with the ambition of realizing carbon neutrality.
基金support of this research by the Research Talent Hub for ITF Project(ITP/002/22LP)sponsored by Hong Kong Innovation and Technology Fund and the Research Grants Council of the Hong Kong SAR(C5018-20GF).
文摘The air conditioning systems in electric city buses usually operate in rapidly changing ambient conditions and are more likely to suffer from mechanical faults. Although many fault detection and diagnosis (FDD) methods have been developed for building air conditioning systems, they are difficult to be applied to bus air conditioners since its operation is highly dynamic and fault-free data are usually unavailable. Therefore, this paper proposes an FDD method for electric bus air conditioners to tackle the above issues. First, the method identifies faults in an unsupervised manner by comparing selected features among a group of peer systems. Then, considering the features are influenced by the operating conditions, Gaussian process regression (GPR) models are established to find the relationships between each feature and its influential parameters. The probabilistic nature of the GPR is used to differentiate predictions with large uncertainty, which are then excluded from FDD. In this way, robustness of the method is evidently improved. Finally, fault indexes are defined to detect and diagnose mechanical faults. We applied the method to a group of air conditioners in a city bus fleet. Results showed that it can effectively identify refrigerant undercharge and indoor and outdoor fan problems with low false positive/genitive rates. Also, the method is highly robust and not sensitive to the faulty systems in the bus fleet.