There is a close theoretical similarity between water pressure gradients in aquifers and applied voltage gradients in aqueous solutions. A series of electric field analogue experiments has been conducted by focusing ...There is a close theoretical similarity between water pressure gradients in aquifers and applied voltage gradients in aqueous solutions. A series of electric field analogue experiments has been conducted by focusing on symmetrical multi-lateral wells and dual-lateral wells of arbitrary angles between laterals. This research not only evaluates the productivity equations of a symmetrical multi-lateral well showing the effect of angles on productivity, but also proposes the concept of the multi-lateral productivity coefficient. Moreover, the multi-lateral productivity coefficient equation is designed to calculate the productivity of dual-lateral wells of variable angles, which is in turn supported by experiment. It also helps provide the experimental basis for optimizing the configuration, and building the semi-analytic productivity model, of multi-lateral wells.展开更多
<em>Objective</em>: In order to take a decision about the revascularization approach to be adopted, it is of fundamental importance to determine whether coronary artery stenoses induce ischemia or not. An ...<em>Objective</em>: In order to take a decision about the revascularization approach to be adopted, it is of fundamental importance to determine whether coronary artery stenoses induce ischemia or not. An index, named (Fractional Flow Reserve), based on pressure measurements has been proposed to this aim and is usually interpreted in terms of flows. The objective of this work is to compute simultaneously pressures and flow rates in the coronary network of patients with three-vessel disease, in order to study more precisely the relationship between these two quantities. <em>Approach</em>: 22 patients have been included in the study. Some pressure and flow rate measurements were collected during by-pass surgery. These clinical data allow determining parameters for a patient’s specific model, based on the electric/hydraulic analogy. Collateral pathways are included in the model, as well as the severity of the disease and the impact of revascularization. <em>Main Results</em>: For patients with stenoses on LAD, LCx, LMCA and occlusion of the RCA, the flow rate delivered to the right territory is of course a function of the aortic pressure, the left stenoses severity, and the pressure distal to the thrombosis. But it mainly depends on the capillary and collateral resistances, and on the proportion between them. Abnormal microvascular hemodynamics, may be present in patients with non-hemodynamic significant lesions as assessed by the pressure ratio. Complete revascularization with the 3 grafts is demonstrated to be fully justified. The direction of collateral flows may be reversed, depending on the pressure gradient. In any case, they remain low and become negligible when the 3 grafts are operating. <em>Significance</em>: Surgical decision based only on pressure measurements may miss some real hemodynamic problems due to the considered stenosis. This risk is even greater in case of serial stenoses.展开更多
Actively cooled thermal protection system has great influence on the engine of a hypersonic vehicle, and it is significant to obtain the thermal and stress distribution in the system. So an analytic estimation and num...Actively cooled thermal protection system has great influence on the engine of a hypersonic vehicle, and it is significant to obtain the thermal and stress distribution in the system. So an analytic estimation and numerical modeling are performed in this paper to investigate the behavior of an actively cooled thermal protection system. The analytic estimation is based on the electric analogy method and finite element analysis(FEA) is applied to the numerical simulation. Temperature and stress distributions are obtained for the actively cooled channel walls with three kinds of nickel alloys with or with no thermal barrier coating(TBC). The temperature of the channel wall with coating has no obvious difference from the one with no coating, but the stress with coating on the channel wall is much smaller than that with no coating. Inconel X-750 has the best characteristics among the three Ni-based materials due to its higher thermal conductivity, lower elasticity module and greater allowable stress. Analytic estimation and numerical modeling results are compared with each other and a reasonable agreement is obtained.展开更多
The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting ...The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting the state-of-art scientific achievements in computer science and other IT fields.From 2012,展开更多
The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting ...The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting the state-of-art scientific achievements in computer science and other IT fields.From 2012,the journal enters into IEEE Xplore Digital Library with the open access mode. In 2015, Tsinghua Science and Technology has been indexed in the Science Citation Index Expanded with IF 1.063.展开更多
文摘There is a close theoretical similarity between water pressure gradients in aquifers and applied voltage gradients in aqueous solutions. A series of electric field analogue experiments has been conducted by focusing on symmetrical multi-lateral wells and dual-lateral wells of arbitrary angles between laterals. This research not only evaluates the productivity equations of a symmetrical multi-lateral well showing the effect of angles on productivity, but also proposes the concept of the multi-lateral productivity coefficient. Moreover, the multi-lateral productivity coefficient equation is designed to calculate the productivity of dual-lateral wells of variable angles, which is in turn supported by experiment. It also helps provide the experimental basis for optimizing the configuration, and building the semi-analytic productivity model, of multi-lateral wells.
文摘<em>Objective</em>: In order to take a decision about the revascularization approach to be adopted, it is of fundamental importance to determine whether coronary artery stenoses induce ischemia or not. An index, named (Fractional Flow Reserve), based on pressure measurements has been proposed to this aim and is usually interpreted in terms of flows. The objective of this work is to compute simultaneously pressures and flow rates in the coronary network of patients with three-vessel disease, in order to study more precisely the relationship between these two quantities. <em>Approach</em>: 22 patients have been included in the study. Some pressure and flow rate measurements were collected during by-pass surgery. These clinical data allow determining parameters for a patient’s specific model, based on the electric/hydraulic analogy. Collateral pathways are included in the model, as well as the severity of the disease and the impact of revascularization. <em>Main Results</em>: For patients with stenoses on LAD, LCx, LMCA and occlusion of the RCA, the flow rate delivered to the right territory is of course a function of the aortic pressure, the left stenoses severity, and the pressure distal to the thrombosis. But it mainly depends on the capillary and collateral resistances, and on the proportion between them. Abnormal microvascular hemodynamics, may be present in patients with non-hemodynamic significant lesions as assessed by the pressure ratio. Complete revascularization with the 3 grafts is demonstrated to be fully justified. The direction of collateral flows may be reversed, depending on the pressure gradient. In any case, they remain low and become negligible when the 3 grafts are operating. <em>Significance</em>: Surgical decision based only on pressure measurements may miss some real hemodynamic problems due to the considered stenosis. This risk is even greater in case of serial stenoses.
基金co-supported by the Foundation for Innovative Research Groups of the National Natural Science Foundation of China (No. 51121004)the Fundamental Research Funds for the Central Universities of China (No. HIT.BRETIV.201315)
文摘Actively cooled thermal protection system has great influence on the engine of a hypersonic vehicle, and it is significant to obtain the thermal and stress distribution in the system. So an analytic estimation and numerical modeling are performed in this paper to investigate the behavior of an actively cooled thermal protection system. The analytic estimation is based on the electric analogy method and finite element analysis(FEA) is applied to the numerical simulation. Temperature and stress distributions are obtained for the actively cooled channel walls with three kinds of nickel alloys with or with no thermal barrier coating(TBC). The temperature of the channel wall with coating has no obvious difference from the one with no coating, but the stress with coating on the channel wall is much smaller than that with no coating. Inconel X-750 has the best characteristics among the three Ni-based materials due to its higher thermal conductivity, lower elasticity module and greater allowable stress. Analytic estimation and numerical modeling results are compared with each other and a reasonable agreement is obtained.
文摘The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting the state-of-art scientific achievements in computer science and other IT fields.From 2012,
文摘The publication of Tsinghua Science and Technology was started in 1996.Since then,it has been an international academic journal sponsored by Tsinghua University and published bimonthly.This journal aims at presenting the state-of-art scientific achievements in computer science and other IT fields.From 2012,the journal enters into IEEE Xplore Digital Library with the open access mode. In 2015, Tsinghua Science and Technology has been indexed in the Science Citation Index Expanded with IF 1.063.