The traditional measurement method was inaccurate to evaluate the motor controller efficiency,which the measurement efficiency value could be more than 100%in practical testing experiments.To deal with this issue,an i...The traditional measurement method was inaccurate to evaluate the motor controller efficiency,which the measurement efficiency value could be more than 100%in practical testing experiments.To deal with this issue,an improved electrical measurement method for the motor controller efficiency is proposed in this paper,which is established by analyzing the power loss distribution and phase currents of the motor controller.It is demonstrated that the SiC MOSFET chips are the main power loss devices in the motor controller,accounting for more than 93.1%of the total power loss.The accuracy of the proposed method is compared with the traditional method in simulation.It shows that the test error of the efficiency obtained by the traditional method fluctuates on a large scale,which varied from 0.094%to 1.911%.Compared with the traditional method,the test error of the proposed method appears to be less than 0.083%,which provides significant guidance for the motor controller efficiency test and design.展开更多
Wood elastic constants are needed to describe the elastic behaviors of wood and be taken as an important design parameter for wood-based composite materials and structural materials. This paper clarified the relations...Wood elastic constants are needed to describe the elastic behaviors of wood and be taken as an important design parameter for wood-based composite materials and structural materials. This paper clarified the relationships between compliance coefficients and engineering elastic constants combined with orthotropic properties of wood, and twelve elastic constants of Betula platyphylla Suk. were measured by electrical strain gauges. Spreading the adhesive quantity cannot be excessive or too little when the strain flakes were glued. If excessive, the glue layer was too thick which would influence the strain flakes?performance, and if too little, glues plastered were not firm, which could not accurately transmit the strain. Wood as an orthotropic material, its modulus of elasticity and poissons ratios are related by two formulas:μij /Ei =μji /Ej and μij < (Ei /Ej)1/2. The results showed that the elastic constants of Betula platyphylla Suk. measured by electrical strain gauges were accurate and reliable. The results of shear elastic modulus GTL and GLR show a high linear regression correlation coefficient (> 0.95) between the reciprocal of elastic modulus MOE-1 and the square of the ratio of depth to length (h/l)2, which indicate that shear modulus values measured were reliable by three point bending experiment.展开更多
基金Supported by National Key Research and Development Program of China(2016YFB0100605)。
文摘The traditional measurement method was inaccurate to evaluate the motor controller efficiency,which the measurement efficiency value could be more than 100%in practical testing experiments.To deal with this issue,an improved electrical measurement method for the motor controller efficiency is proposed in this paper,which is established by analyzing the power loss distribution and phase currents of the motor controller.It is demonstrated that the SiC MOSFET chips are the main power loss devices in the motor controller,accounting for more than 93.1%of the total power loss.The accuracy of the proposed method is compared with the traditional method in simulation.It shows that the test error of the efficiency obtained by the traditional method fluctuates on a large scale,which varied from 0.094%to 1.911%.Compared with the traditional method,the test error of the proposed method appears to be less than 0.083%,which provides significant guidance for the motor controller efficiency test and design.
文摘Wood elastic constants are needed to describe the elastic behaviors of wood and be taken as an important design parameter for wood-based composite materials and structural materials. This paper clarified the relationships between compliance coefficients and engineering elastic constants combined with orthotropic properties of wood, and twelve elastic constants of Betula platyphylla Suk. were measured by electrical strain gauges. Spreading the adhesive quantity cannot be excessive or too little when the strain flakes were glued. If excessive, the glue layer was too thick which would influence the strain flakes?performance, and if too little, glues plastered were not firm, which could not accurately transmit the strain. Wood as an orthotropic material, its modulus of elasticity and poissons ratios are related by two formulas:μij /Ei =μji /Ej and μij < (Ei /Ej)1/2. The results showed that the elastic constants of Betula platyphylla Suk. measured by electrical strain gauges were accurate and reliable. The results of shear elastic modulus GTL and GLR show a high linear regression correlation coefficient (> 0.95) between the reciprocal of elastic modulus MOE-1 and the square of the ratio of depth to length (h/l)2, which indicate that shear modulus values measured were reliable by three point bending experiment.