Background: A major cause of mortality and disability on a global scale is myocardial infarction (MI). These days, the most reliable way to detect and measure MI is via cardiovascular magnetic resonance imaging (CMR)....Background: A major cause of mortality and disability on a global scale is myocardial infarction (MI). These days, the most reliable way to detect and measure MI is via cardiovascular magnetic resonance imaging (CMR). Aims and Objectives: To evaluate the effectiveness of the Electrocardiogram DETERMINE Score in predicting the severity of coronary artery disease (CAD) in patients who have experienced an Acute Myocardial Infarction (AMI) & to assess improvements in left ventricular function at 6 months following coronary artery bypass grafting (CABG). Subjects and Methods: This Observational cohort study was done at the Cardiology and Radiology department and cardiac surgery department, Al-Azhar university hospitals and Helwan University hospital. The study involved 700 cases who patients diagnosed with Acute Myocardial Infarction and fulfilled specific criteria for selection. Result: There was highly statistically significant relation between Myocardial infarction size and ECG Marker Score as mean infarct size elevated When the number of ECG markers increased. There was a highly statistically significant relation between myocardial infarct segments, myocardial infarction size and improvement of cardiac function 6 months post-CABG. Conclusion: The study found that larger myocardial infarctions corresponded with higher DETERMINE Scores. It concluded that an ECG-based score better estimates infarct size than LVEF alone. Additionally, there was a significant statistical correlation between the size and segmentation of myocardial infarction and better cardiac function six months after CABG.展开更多
Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identif...Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identifying arrhythmias.The evolving landscape of fabric electrodes,specifically designed for the prolonged monitoring of human ECG signals,is the focus of this research.Adhering to the preferred reporting items for systematic reviews and meta-analyses(PRISMA)statement and assimilating data from 81 pertinent studies sourced from reputable databases,the research conducts a comprehensive systematic review and meta-analysis on the materials,fabric structures and preparation methods of fabric electrodes in the existing literature.It provides a nuanced assessment of the advantages and disadvantages of diverse textile materials and structures,elucidating their impacts on the stability of biomonitoring signals.Furthermore,the study outlines current developmental constraints and future trajectories for fabric electrodes.These insights could serve as essential guidance for ECG monitoring system designers,aiding them in the selection of materials that optimize the measurement of biopotential signals.展开更多
Electrocardiograms (ECG) of Eremias multiocellata were studied at 5-35℃ in body temperature. Electrocardiogram wave intervals (R-R,P-R,QRS,T-P,and R-T) shortened while heart rate increased with the increasing of bod...Electrocardiograms (ECG) of Eremias multiocellata were studied at 5-35℃ in body temperature. Electrocardiogram wave intervals (R-R,P-R,QRS,T-P,and R-T) shortened while heart rate increased with the increasing of body temperature. The average heart rate was 14.6/min at 5℃,whereas it was 201/min at 35℃. The duration of wave intervals of ECG and the heart rate were related significantly to the body temperature (P<0.001). Among the components of a cardiac cycle the cardiac rest period (TP intervals) and the atria-ventricular conduction time (PR interval) were affected mostly by body temperature. In the other hand the ventricular depolarization and repolarization (QRS and R-T intervals) were relatively less affected by the body temperature. The increasing of heart rate with body temperature was mainly caused by the shortening of ECG wave intervals,and the T-P interval (the cardiac rest period) was shortened more noticeably than other intervals.展开更多
Hydrogen sulfide (H2S) is the third gaseous signaling molecule discovered in recent years, and plays an important physiological role in the cardivascular system. To explore the effects of different doses of exogenou...Hydrogen sulfide (H2S) is the third gaseous signaling molecule discovered in recent years, and plays an important physiological role in the cardivascular system. To explore the effects of different doses of exogenous H2S on the electrocardiogram (ECG) of rats generally anesthetized by zoletil, different doses of NariS solution were used for the intervention of intraperitoneal injection 20 rain before the zoletil anesthesia. The ECGs of rats from each treatment group during the time range of 10^th-50^th min were determined under general anesthesia, and then were compared with those from the control group. The results showed that exogenous H2S could significantly reduce the Q-T interval time limit, thus played a role in slowing tachycardia or arrhythmia and other anomalies, thereby protecting the heart. S-T segment and T segment evaluation values were significantly reduced, which might be associated with bradycardia.展开更多
文摘Background: A major cause of mortality and disability on a global scale is myocardial infarction (MI). These days, the most reliable way to detect and measure MI is via cardiovascular magnetic resonance imaging (CMR). Aims and Objectives: To evaluate the effectiveness of the Electrocardiogram DETERMINE Score in predicting the severity of coronary artery disease (CAD) in patients who have experienced an Acute Myocardial Infarction (AMI) & to assess improvements in left ventricular function at 6 months following coronary artery bypass grafting (CABG). Subjects and Methods: This Observational cohort study was done at the Cardiology and Radiology department and cardiac surgery department, Al-Azhar university hospitals and Helwan University hospital. The study involved 700 cases who patients diagnosed with Acute Myocardial Infarction and fulfilled specific criteria for selection. Result: There was highly statistically significant relation between Myocardial infarction size and ECG Marker Score as mean infarct size elevated When the number of ECG markers increased. There was a highly statistically significant relation between myocardial infarct segments, myocardial infarction size and improvement of cardiac function 6 months post-CABG. Conclusion: The study found that larger myocardial infarctions corresponded with higher DETERMINE Scores. It concluded that an ECG-based score better estimates infarct size than LVEF alone. Additionally, there was a significant statistical correlation between the size and segmentation of myocardial infarction and better cardiac function six months after CABG.
文摘Cardiovascular disease persists as the primary cause of human mortality,significantly impacting healthy life expectancy.The routine electrocardiogram(ECG)stands out as a pivotal noninvasive diagnostic tool for identifying arrhythmias.The evolving landscape of fabric electrodes,specifically designed for the prolonged monitoring of human ECG signals,is the focus of this research.Adhering to the preferred reporting items for systematic reviews and meta-analyses(PRISMA)statement and assimilating data from 81 pertinent studies sourced from reputable databases,the research conducts a comprehensive systematic review and meta-analysis on the materials,fabric structures and preparation methods of fabric electrodes in the existing literature.It provides a nuanced assessment of the advantages and disadvantages of diverse textile materials and structures,elucidating their impacts on the stability of biomonitoring signals.Furthermore,the study outlines current developmental constraints and future trajectories for fabric electrodes.These insights could serve as essential guidance for ECG monitoring system designers,aiding them in the selection of materials that optimize the measurement of biopotential signals.
文摘Electrocardiograms (ECG) of Eremias multiocellata were studied at 5-35℃ in body temperature. Electrocardiogram wave intervals (R-R,P-R,QRS,T-P,and R-T) shortened while heart rate increased with the increasing of body temperature. The average heart rate was 14.6/min at 5℃,whereas it was 201/min at 35℃. The duration of wave intervals of ECG and the heart rate were related significantly to the body temperature (P<0.001). Among the components of a cardiac cycle the cardiac rest period (TP intervals) and the atria-ventricular conduction time (PR interval) were affected mostly by body temperature. In the other hand the ventricular depolarization and repolarization (QRS and R-T intervals) were relatively less affected by the body temperature. The increasing of heart rate with body temperature was mainly caused by the shortening of ECG wave intervals,and the T-P interval (the cardiac rest period) was shortened more noticeably than other intervals.
文摘Hydrogen sulfide (H2S) is the third gaseous signaling molecule discovered in recent years, and plays an important physiological role in the cardivascular system. To explore the effects of different doses of exogenous H2S on the electrocardiogram (ECG) of rats generally anesthetized by zoletil, different doses of NariS solution were used for the intervention of intraperitoneal injection 20 rain before the zoletil anesthesia. The ECGs of rats from each treatment group during the time range of 10^th-50^th min were determined under general anesthesia, and then were compared with those from the control group. The results showed that exogenous H2S could significantly reduce the Q-T interval time limit, thus played a role in slowing tachycardia or arrhythmia and other anomalies, thereby protecting the heart. S-T segment and T segment evaluation values were significantly reduced, which might be associated with bradycardia.