Dielectric wall accelerator(DWA), towards high gradient acceleration field(30 MeV/m–100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. Th...Dielectric wall accelerator(DWA), towards high gradient acceleration field(30 MeV/m–100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. This needs a short pulse high current electron source to match the acceleration field generated by the Blumlein-type pulse forming lines(PFLs). In this paper, we report the design and test of a new type short pulse high current electron gun based on principle of vacuum arc discharge. Electron beams of 100 mA with pulse width of 10 ns were obtained.展开更多
Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam...Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam quality under different cathode positions were simulated by CST software.Results Changes in the cathode position can cause changes in the electricfield distributions under the cathode emission surface change,thereby changing the size of the effective emitting area and affecting the relationship between the bias voltage and beam current.Conclusions Only when the cathode is installed in the proper positions,the beam current and the bias voltage have an approximately linear proportional relationship.When the cathode is installed improperly,the electron beam emission is disordered,resulting in decreased electron beam quality.展开更多
为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测...为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测量值基本吻合,线圈内部的磁感应强度大小和电磁场分布的均匀性可以满足电子束高频偏转扫描的要求。实际扫描试验表明,该线圈实现了两点电子束高频偏转扫描,扫描频率可达30 k Hz。展开更多
基金Supported by knowledge innovation project of Chinese academy of sciences(No.Y115280YZD)the National Natural Science Foundation of China(No.11105195 and No.11105197)
文摘Dielectric wall accelerator(DWA), towards high gradient acceleration field(30 MeV/m–100 MeV/m), is under development at Institute of Modern Physics. A prototype was designed and constructed to prove the principle. This needs a short pulse high current electron source to match the acceleration field generated by the Blumlein-type pulse forming lines(PFLs). In this paper, we report the design and test of a new type short pulse high current electron gun based on principle of vacuum arc discharge. Electron beams of 100 mA with pulse width of 10 ns were obtained.
基金funded by National Natural Science Foundation of China(Nos.51805265,51775527)Natural Science Foundation of Jiangsu Province(No.BK20180472).
文摘Purpose The research focuses on the simulation of influence of cathode positions on beam current characteristics in the thermionic electron gun.Methods The electricfield distribution,bias voltage range and electron beam quality under different cathode positions were simulated by CST software.Results Changes in the cathode position can cause changes in the electricfield distributions under the cathode emission surface change,thereby changing the size of the effective emitting area and affecting the relationship between the bias voltage and beam current.Conclusions Only when the cathode is installed in the proper positions,the beam current and the bias voltage have an approximately linear proportional relationship.When the cathode is installed improperly,the electron beam emission is disordered,resulting in decreased electron beam quality.
文摘为了提高电子束偏转扫描频率和磁场均匀性,采用Helmholtz空心线圈结构设计了一种低感抗电子枪偏转扫描线圈。采用ANSYS有限元分析软件对偏转扫描线圈的电磁场分布进行仿真,并采用高斯计对线圈内部的电磁场进行了测量,仿真结果与实际测量值基本吻合,线圈内部的磁感应强度大小和电磁场分布的均匀性可以满足电子束高频偏转扫描的要求。实际扫描试验表明,该线圈实现了两点电子束高频偏转扫描,扫描频率可达30 k Hz。