Design and simulation results of a novel multifunctional electronic calibration kit based on microelectromechanical system(MEMS)single-pole double-throw(SPDT)switches are presented in this paper.The short-open-load-th...Design and simulation results of a novel multifunctional electronic calibration kit based on microelectromechanical system(MEMS)single-pole double-throw(SPDT)switches are presented in this paper.The short-open-load-through(SOLT)calibration states can be completed simultaneously by using the MEMS electronic calibration,and the electronic calibrator can be reused 10^(6) times.The simulation results show that this novel electronic calibration can be used in a frequency range of 0.1 GHz–20 GHz,the return loss is less than 0.18 dB and 0.035 dB in short-circuit and open-circuit states,respectively,and the insertion loss in through(thru)state is less than 0.27 dB.On the other hand,the size of this novel calibration kit is only 6 mm×2.8 mm×0.8 mm.Our results demonstrate that the calibrator with integrated radiofrequency microelectromechanical system(RF MEMS)switches can not only provide reduced size,loss,and calibration cost compared with traditional calibration kit but also improves the calibration accuracy and efficiency.It has great potential applications in millimeter-wave measurement and testing technologies,such as device testing,vector network analyzers,and RF probe stations.展开更多
A Michelson interferometer, on loan from EFDA-JET(Culham, United Kingdom)has recently been commissioned on the experimental advanced superconducting tokamak(EAST,ASIPP, Hefei, China). Following a successful in-sit...A Michelson interferometer, on loan from EFDA-JET(Culham, United Kingdom)has recently been commissioned on the experimental advanced superconducting tokamak(EAST,ASIPP, Hefei, China). Following a successful in-situ absolute calibration the instrument is able to measure the electron cyclotron emission(ECE) spectrum, from 80 GHz to 350 GHz in extraordinary mode(X-mode) polarization, with high accuracy. This allows the independent determination of the electron temperature profile from observation of the second harmonic ECE and the possible identification of non-Maxwellian features by comparing higher harmonic emission with numerical simulations. The in-situ calibration results are presented together with the initial measured temperature profiles. These measurements are then discussed and compared with other independent temperature profile measurements. This paper also describes the main hardware features of the diagnostic and the associated commissioning test results.展开更多
Beam measurement is very important for accelerators. In this paper, modern digital beam measurement techniques based on I Q(In-phase & Quadrature-phase) analysis are discussed. Based on this method and highspeed hi...Beam measurement is very important for accelerators. In this paper, modern digital beam measurement techniques based on I Q(In-phase & Quadrature-phase) analysis are discussed. Based on this method and highspeed high-resolution analog-to-digital conversion, we have completed three beam measurement electronics systems designed for the China Spallation Neutron Source(CSNS), Shanghai Synchrotron Radiation Facility(SSRF), and Accelerator Driven Sub-critical system(ADS). Core techniques of hardware design and real-time system calibration are discussed, and performance test results of these three instruments are also presented.展开更多
基金Project supported by the National Defense Technology Industry Strong,China (Grant No. JCKY2018408B006)the Information System New Items Project,China (Grant Nos. 2018XW0026 and 2019XW0010)the Information System Pre-research Project,China (Grant No. 31513060101)
文摘Design and simulation results of a novel multifunctional electronic calibration kit based on microelectromechanical system(MEMS)single-pole double-throw(SPDT)switches are presented in this paper.The short-open-load-through(SOLT)calibration states can be completed simultaneously by using the MEMS electronic calibration,and the electronic calibrator can be reused 10^(6) times.The simulation results show that this novel electronic calibration can be used in a frequency range of 0.1 GHz–20 GHz,the return loss is less than 0.18 dB and 0.035 dB in short-circuit and open-circuit states,respectively,and the insertion loss in through(thru)state is less than 0.27 dB.On the other hand,the size of this novel calibration kit is only 6 mm×2.8 mm×0.8 mm.Our results demonstrate that the calibrator with integrated radiofrequency microelectromechanical system(RF MEMS)switches can not only provide reduced size,loss,and calibration cost compared with traditional calibration kit but also improves the calibration accuracy and efficiency.It has great potential applications in millimeter-wave measurement and testing technologies,such as device testing,vector network analyzers,and RF probe stations.
基金supported by National Natural Science Foundation of China(Nos.11405211,11275233)the National Magnetic Confinement Fusion Science Program of China(Nos.2013GB106002,2015GB101000)+1 种基金the RCUK Energy Programme(No.EP/I501045)partly supported by the JSPS-NRF-NSFC A3 Foresight Program in the Field of Plasma Physics(NSFC:No.11261140328)
文摘A Michelson interferometer, on loan from EFDA-JET(Culham, United Kingdom)has recently been commissioned on the experimental advanced superconducting tokamak(EAST,ASIPP, Hefei, China). Following a successful in-situ absolute calibration the instrument is able to measure the electron cyclotron emission(ECE) spectrum, from 80 GHz to 350 GHz in extraordinary mode(X-mode) polarization, with high accuracy. This allows the independent determination of the electron temperature profile from observation of the second harmonic ECE and the possible identification of non-Maxwellian features by comparing higher harmonic emission with numerical simulations. The in-situ calibration results are presented together with the initial measured temperature profiles. These measurements are then discussed and compared with other independent temperature profile measurements. This paper also describes the main hardware features of the diagnostic and the associated commissioning test results.
基金Supported by National Natural Science Foundation of China(11205153,10875119)Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)+1 种基金the Fundamental Research Funds for the Central Universities(WK2030040029)the CAS Center for Excellence in Particle Physics(CCEPP)
文摘Beam measurement is very important for accelerators. In this paper, modern digital beam measurement techniques based on I Q(In-phase & Quadrature-phase) analysis are discussed. Based on this method and highspeed high-resolution analog-to-digital conversion, we have completed three beam measurement electronics systems designed for the China Spallation Neutron Source(CSNS), Shanghai Synchrotron Radiation Facility(SSRF), and Accelerator Driven Sub-critical system(ADS). Core techniques of hardware design and real-time system calibration are discussed, and performance test results of these three instruments are also presented.