As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe desi...The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe design by focusing on design requirements,principles,and key elements.Drawing from relevant design optimization experiences,technology advancements,and optimization measures,the research will analyze and consolidate the essential aspects of municipal water supply and drainage pipe design.The goal is to fundamentally elevate the quality standards of these designs,ensuring they meet the criteria for engineering project excellence.Through this comprehensive approach,we aim to contribute to the improvement and sustainability of water supply and drainage systems,safeguarding the well-being of residents.展开更多
With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply...With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.展开更多
For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention....For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.展开更多
The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated s...The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.展开更多
In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow ...In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow and water source head. By using pump-station pressure head and initial tank water levels as decision variables, the model of optimal allocation of water supply between pump-sources was developed. Genetic algorithm was introduced to deal with the model of optimal allocation of water supply. Methods for handling each constraint condition were put forward, and overcome the shortcoming such as premature convergence of genetic algorithm; a solving method was brought forward in which genetic algorithm was combined with simulated annealing technology and self-adaptive crossover and mutation probabilities were adopted. An application example showed the feasibility of this algorithm.展开更多
With the continuous development of economy and society and the continuous improvement of peoples’living environment requirements,the concept of sponge city construction has been recognized and understood by more and ...With the continuous development of economy and society and the continuous improvement of peoples’living environment requirements,the concept of sponge city construction has been recognized and understood by more and more people.The country has also recognized the significance of planning and construction of sponge cities.In the process of planning and constructing a sponge city,it is necessary to combine the reality of urban development with the construction of urban water supply and drainage systems and underground pipe corridors to promote the process of urban modernization.Based on this,this paper analyzes the water supply and drainage construction of the integrated pipe corridor in the sponge city.展开更多
The construction of water supply and drainage pipelines is a very important part of municipal construction.The construction of HDPE pipe has been widely used in the construction field of water supply and drainage pipe...The construction of water supply and drainage pipelines is a very important part of municipal construction.The construction of HDPE pipe has been widely used in the construction field of water supply and drainage pipelines due to its many advantages.Therefore,the construction process of HDPE pipe has also been studied more and more in the construction of municipal water supply and drainage,which is of great significance for the application of HDPE in municipal water supply and drainage construction.This paper analyzes the HDPE pipe construction process of municipal water supply and drainage construction workers,and hopes to help the good application of HDPE pipe and the improvement of municipal water supply and drainage construction quality.展开更多
Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to cat...Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed.展开更多
Geographic Information Systems(GIS) can be successfully introduced as a tool to manage water system infrastructures.This technology was taken into consideration after the local authorities’ estimation for almost 30%l...Geographic Information Systems(GIS) can be successfully introduced as a tool to manage water system infrastructures.This technology was taken into consideration after the local authorities’ estimation for almost 30%losses in the water distribution networks in cities.The major issue of water shortage in展开更多
The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and...The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and prevent them. The described methodology has been applied based on a cross-border cooperation between twin capital cities Vienna and Bratislava in the Central Europe Region within the project deWaloP (Developing Water Loss Prevention) and adopted in Bratislava Water Company (BVS) in the Slovak Republic. The paper provides a complex of simple and easily available practices for analyses of water distribution measurements bringing essential information as to the necessity to use advanced procedures to actively reduce leakage. These practices involve minimum night flows analyses, hydrodynamic pressures analyses, pinpointing of water leakages by working with valves in the water network, the methodology of setting alarm limits for measured data, as well as use of advanced practices to obtain missing topologic data. As the water infrastructure in former socialistic countries are in bad technical condition and the lack of pertinent operational data is a significant obstacle to the application of a more sophisticated methodology based on GIS and other information systems, the procedures focus on using the most simple way to evaluate and control water losses. Finally, the introduction of described methodology in Bratislava Water Company after many years of unsuccessful effort even with expensive sophisticated leakage equipment brought positive outputs and the graph line of water losses level is finally going down. The use of expensive multi-correlating equipment together with human resources on the basis of implementing the above described leakage monitoring will subsequently become more effective, as it shall pinpoint major leakages, disclosure and removal of that shall significantly contribute to the effective reduction of water losses.展开更多
Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to i...Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to investigate the influence of SWSSs on the seasonal changes in heavy metal concentrations from input water to tank and tap water. The concentrations of nine evaluated heavy metals in all groups of water samples were found to be far below the specified standard levels in China. The concentrations of Fe, Mn, and Zn increased significantly from the input water samples to the tank and tap water samples in spring and summer( p < 0.05), especially for the water samples that had been stagnant for a long time. Negative correlations were found between most of the heavy metals and residual chlorine(Fe, Cu, Zn, and As, r =-0.186 to-0.519, p < 0.05). In particular, a high negative correlation was observed between Fe and residual chlorine( r =-0.489 to-0.519, p < 0.01) in spring and summer. Fe and Mn displayed positive correlations with turbidity( r = 0.672 and 0.328, respectively;p < 0.05). In addition, Cr and As were found to be positively associated with some nutrients(NO, TN, and SO;r = 0.420-0.786, p < 0.01). The material of the storage tanks had little influence on the difference in heavy metal concentrations. Overall, this survey illustrated that SWSSs may pose a chronic threat to water quality and could provide useful information for practitioners.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
文摘The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe design by focusing on design requirements,principles,and key elements.Drawing from relevant design optimization experiences,technology advancements,and optimization measures,the research will analyze and consolidate the essential aspects of municipal water supply and drainage pipe design.The goal is to fundamentally elevate the quality standards of these designs,ensuring they meet the criteria for engineering project excellence.Through this comprehensive approach,we aim to contribute to the improvement and sustainability of water supply and drainage systems,safeguarding the well-being of residents.
文摘With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.
基金supported by the National Natural Science Foundation of China(Grants No.52179062 and 51879087).
文摘For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.
文摘The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.
基金Project (No. 50078048) supported by the National Natural Science Foundation of China
文摘In view of the poor water supply system’s network properties, the system’s complicated network hydraulic equations were replaced by macroscopic nodal pressure model and the model of relationship between supply flow and water source head. By using pump-station pressure head and initial tank water levels as decision variables, the model of optimal allocation of water supply between pump-sources was developed. Genetic algorithm was introduced to deal with the model of optimal allocation of water supply. Methods for handling each constraint condition were put forward, and overcome the shortcoming such as premature convergence of genetic algorithm; a solving method was brought forward in which genetic algorithm was combined with simulated annealing technology and self-adaptive crossover and mutation probabilities were adopted. An application example showed the feasibility of this algorithm.
文摘With the continuous development of economy and society and the continuous improvement of peoples’living environment requirements,the concept of sponge city construction has been recognized and understood by more and more people.The country has also recognized the significance of planning and construction of sponge cities.In the process of planning and constructing a sponge city,it is necessary to combine the reality of urban development with the construction of urban water supply and drainage systems and underground pipe corridors to promote the process of urban modernization.Based on this,this paper analyzes the water supply and drainage construction of the integrated pipe corridor in the sponge city.
文摘The construction of water supply and drainage pipelines is a very important part of municipal construction.The construction of HDPE pipe has been widely used in the construction field of water supply and drainage pipelines due to its many advantages.Therefore,the construction process of HDPE pipe has also been studied more and more in the construction of municipal water supply and drainage,which is of great significance for the application of HDPE in municipal water supply and drainage construction.This paper analyzes the HDPE pipe construction process of municipal water supply and drainage construction workers,and hopes to help the good application of HDPE pipe and the improvement of municipal water supply and drainage construction quality.
文摘Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed.
文摘Geographic Information Systems(GIS) can be successfully introduced as a tool to manage water system infrastructures.This technology was taken into consideration after the local authorities’ estimation for almost 30%losses in the water distribution networks in cities.The major issue of water shortage in
文摘The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and prevent them. The described methodology has been applied based on a cross-border cooperation between twin capital cities Vienna and Bratislava in the Central Europe Region within the project deWaloP (Developing Water Loss Prevention) and adopted in Bratislava Water Company (BVS) in the Slovak Republic. The paper provides a complex of simple and easily available practices for analyses of water distribution measurements bringing essential information as to the necessity to use advanced procedures to actively reduce leakage. These practices involve minimum night flows analyses, hydrodynamic pressures analyses, pinpointing of water leakages by working with valves in the water network, the methodology of setting alarm limits for measured data, as well as use of advanced practices to obtain missing topologic data. As the water infrastructure in former socialistic countries are in bad technical condition and the lack of pertinent operational data is a significant obstacle to the application of a more sophisticated methodology based on GIS and other information systems, the procedures focus on using the most simple way to evaluate and control water losses. Finally, the introduction of described methodology in Bratislava Water Company after many years of unsuccessful effort even with expensive sophisticated leakage equipment brought positive outputs and the graph line of water losses level is finally going down. The use of expensive multi-correlating equipment together with human resources on the basis of implementing the above described leakage monitoring will subsequently become more effective, as it shall pinpoint major leakages, disclosure and removal of that shall significantly contribute to the effective reduction of water losses.
基金supported by the National Natural Science Foundation of China (Nos. 41861144023, U2005206)Xiamen Municipal Bureau of Science and Technology (No. YDZX20203502000003)。
文摘Water quality deterioration often occurs in secondary water supply systems(SWSSs), and increased heavy metal concentrations can be a serious problem. In this survey, twelve residential neighborhoods were selected to investigate the influence of SWSSs on the seasonal changes in heavy metal concentrations from input water to tank and tap water. The concentrations of nine evaluated heavy metals in all groups of water samples were found to be far below the specified standard levels in China. The concentrations of Fe, Mn, and Zn increased significantly from the input water samples to the tank and tap water samples in spring and summer( p < 0.05), especially for the water samples that had been stagnant for a long time. Negative correlations were found between most of the heavy metals and residual chlorine(Fe, Cu, Zn, and As, r =-0.186 to-0.519, p < 0.05). In particular, a high negative correlation was observed between Fe and residual chlorine( r =-0.489 to-0.519, p < 0.01) in spring and summer. Fe and Mn displayed positive correlations with turbidity( r = 0.672 and 0.328, respectively;p < 0.05). In addition, Cr and As were found to be positively associated with some nutrients(NO, TN, and SO;r = 0.420-0.786, p < 0.01). The material of the storage tanks had little influence on the difference in heavy metal concentrations. Overall, this survey illustrated that SWSSs may pose a chronic threat to water quality and could provide useful information for practitioners.