期刊文献+
共找到120篇文章
< 1 2 6 >
每页显示 20 50 100
Grouping separation of mixed rare earths from their coexisting aqueous solutions by liquid-column elution 被引量:3
1
作者 Wenjuan Cao Kun Huang +1 位作者 Xiaoqin Wang Huizhou Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第8期1828-1836,共9页
A new approach was proposed for grouping separation of 14 lanthanide rare-earth ions from their coexisting mixed aqueous solutions, by performing liquid-column elution using the aqueous solution containing 14 lanthani... A new approach was proposed for grouping separation of 14 lanthanide rare-earth ions from their coexisting mixed aqueous solutions, by performing liquid-column elution using the aqueous solution containing 14 lanthanide rare-earth ions as the stationary phase and the dispersed organic oil droplets containing P507 extractant as the mobile phase. It was revealed that 14 lanthanide rare-earth ions could be separated into four groups, according to the lanthanide tetrad effect, respectively eluting out from the liquid column at different time in a certain order. Various effects including the saponification degree of P507, the concentration of P507 in organic phase, the length and inner diameter of the extraction column on the performance of grouping separation of rare-earth ions were discussed. The changes of the mass transfer coefficients were also investigated. The separation efficiency of the four groups of rareearth elements(REEs) was evaluated based on the elution resolution, Rs, of the elution peaks of La(Ⅲ),Gd(Ⅲ), Ho(Ⅲ) and Lu(Ⅲ), the four representative elements respectively from each of the four groups of REEs. Experimental results demonstrated that the separation of REEs by liquid-column elution mainly depended on the competitive adsorption of different rare-earth groups onto the surface of ascending P507 oil droplets. The affinity of different rare-earth groups with P507 extractant and a limited adsorption capacity of P507 molecules at the surface of the oil droplets ascending in liquid column play the important role. The present work highlights a promising technique for grouping separation of multiple lanthanide elements co-existing complex systems. 展开更多
关键词 elution LANTHANIDE TETRAD effect RARE-EARTHS Group SEPARATION
下载PDF
Purification of Pseudomonas sp. Lipase by Continuous Elution Electrophoresis Based on Pb^(2+) Precipitation Method
2
作者 ZHANGHua-li WANGZhi LIUBin WANGXue-li CAOShu-gui LIZheng-qiang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2005年第4期468-470,共3页
A Pb 2+ precipitation method was designed to get rid of the impure proteins in a lipase. The results show that it was a simple way in the primary treatment of the crude samples and about 20% impure proteins were remov... A Pb 2+ precipitation method was designed to get rid of the impure proteins in a lipase. The results show that it was a simple way in the primary treatment of the crude samples and about 20% impure proteins were removed in the precipitation step. Further, continuous elution electrophoresis was also applied as a preparative technique for attaining the highly pure lipase. During the continuous elution electrophoresis, the enzyme was eluted as a single peak and 5.7-fold purification was achieved in a yield of 54.3%. The two steps finally yielded an electrophoretically homogeneous enzyme. 展开更多
关键词 ULTRAFILTRATION Continuous elution electrophoresis Pb^(2+) precipitation Pseudomonas sp. Lipase
下载PDF
Microcomputer Simulation of Elution Behaviour for Dicarboxylic Acids in Ion-Exclusion Chromatography
3
作者 Zhao Guo-liang ZHAO Yu-ming and Liu Li-na (Deaprtment of Chemistry Dalian University of Technology, Dalian, 116011 ) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第2期79-84,共6页
he present paper covers a model involving Donnan memhrane equilibrium andadsorption eluilibrium to describe the retention process for diprotic organic acids inion-exclusion chromatography. On this basis the microcompu... he present paper covers a model involving Donnan memhrane equilibrium andadsorption eluilibrium to describe the retention process for diprotic organic acids inion-exclusion chromatography. On this basis the microcomputer simulation of elu-tion behaviour for dicarboxylic acids was investigated. Influences of eluent acidityand sample concentration on the retention value were studied. The theoreticallypredicted results are in reasonable agreement with the experimental data. 展开更多
关键词 Ion-exclusion chromatography elution behaviour Microcomputer simulation Dicarboxylic acids
下载PDF
Kinetics of Elution of Gentamicin from a Gentamicin-Loaded PMMA Bone Cement
4
作者 Gladius Lewis Li Li 《World Journal of Engineering and Technology》 2019年第3期418-428,共11页
Antibiotic-loaded poly (methyl methacrylate) bone cement (ALBC) is widely used for anchoring joint replacements as a means of reducing the potential for peri-prosthetic joint infection (primary cases) and treating a p... Antibiotic-loaded poly (methyl methacrylate) bone cement (ALBC) is widely used for anchoring joint replacements as a means of reducing the potential for peri-prosthetic joint infection (primary cases) and treating a patient who has an infected joint replacement (revision cases). One shortcoming of the cement is the high maximum exothermic temperature experienced upon polymerization (Tmax), a phenomenon that, it has been postulated, may cause or be implicated in thermal necrosis of peri-prosthetic tissues. There are many reports in the literature on methods of reducing Tmax, with one such study involving the addition of a phase change material (microencapsulated paraffin) (MEPAR) to the cement powder or adding a chain-stopping chemical (1-dodecyl mercaptan) (DDM) to the liquid. In that report, the results of gentamicin elution tests were presented. In the present work, those results were used to calculate various indices of gentamicin elution kinetics, namely 1) diffusion coefficient (Dgent);and 2) values of the coefficients in four equations that are widely used to model antibiotic elution from ALBCs. We found 1) the difference in Dgent of either a MEPAR- or DDM-containing formulation, on the one hand, and that of the control cement, on the other, was not significant;and 2) a consistent trend in the value of only one coefficient in one of the four model equations, with this change suggesting insignificant difference in gentamicin elution mechanism between an experimental cement formulation and the control cement. The implications of these findings for guiding selection of additives that simultaneously produce significant reduction of Tmax but minimal effect on gentamicin elution kinetics are discussed. This guide is a novel contribution to the literature. 展开更多
关键词 Poly (Methyl Methacrylate) Bone CEMENT GENTAMICIN elution Diffusion Coefficient KINETICS Models
下载PDF
Acid Elution of Aluminum and Calcium from Human Deciduous Enamel in Relation to Dental Caries
5
作者 Koji Watanabe Toshiko Tanaka +5 位作者 Ayaka Enomoto Katsura Saeki Shigenori Kawagishi Hideaki Nakashima Kenshi Maki Shigeru Watanabe 《Open Journal of Stomatology》 2016年第2期54-63,共10页
Although aluminum itself was reported to prevent dental caries, previous in vitro studies reported that the aluminum level in the whole saliva of children was independent of caries prevalence. Purposes of this study w... Although aluminum itself was reported to prevent dental caries, previous in vitro studies reported that the aluminum level in the whole saliva of children was independent of caries prevalence. Purposes of this study were to compare the elution levels of aluminum and calcium from deciduous enamel into acidic artificial saliva, and determine whether the degree of aluminum elution reflects individual caries risk. One hundred and eleven extracted human deciduous teeth were collected. Concentrations of aluminum and calcium eluted from sound regions of enamel into artificial saliva (pH 6.2 or 5.5) were determined using atomic absorption spectrophotometry. One hundred and four and 108 available data samples were obtained for aluminum and calcium evaluation, respectively, and were compared based on the sex, tooth type, caries history, and the number of the donor’s carious teeth at each pH. Calcium elution was not affected by the sex;however, more aluminum was eluted from boys’ than from girls’ teeth at pH 5.5. The aluminum release depended on the tooth type, and was significantly higher in incisors than in molars at a pH of 5.5. In relation to the caries history, aluminum (at pH 5.5) and calcium (at pH 6.2) dissolved more from sound regions of the enamel of caries-experienced teeth than from the enamel of teeth without caries experience. Moreover, aluminum markedly dissolved from enamel in artificial saliva at both pH 6.2 and 5.5 when the donor had more carious teeth, regardless of the presence or absence of caries experience in the sampled teeth. There is a possibility that the rate of aluminum elution from enamel into acidic fluid reflects individual caries sensitivity. 展开更多
关键词 ALUMINUM elution Deciduous Enamel Dental Caries Artificial Saliva
下载PDF
Comparison between Two Ethanolic Solutions for 3’-Deoxy-3’-[<sup>18</sup>F]Fluorothymidine Elution
6
作者 Leonardo T. C. Nascimento Marina B. Silveira +1 位作者 Soraya M. Z. M. D. Ferreira Juliana B. Silva 《Advances in Chemical Engineering and Science》 2017年第1期23-33,共11页
3’-Deoxy-3’-[18F]Fluorothymidine—[18F]FLT is a Positron Emission Tomography (PET) tracer which has been used for noninvasive assessment of proliferation activity in several types of cancer. During the past few year... 3’-Deoxy-3’-[18F]Fluorothymidine—[18F]FLT is a Positron Emission Tomography (PET) tracer which has been used for noninvasive assessment of proliferation activity in several types of cancer. During the past few years, some novel approaches for [18F]FLT synthesis have been developed, mainly focused on optimization of reaction conditions and purification methods. The present study reports the use of two different eluents in the final step of [18F]FLT production and the evaluation of its effect on radiochemical yield and product quality. The first eluent evaluated was water: ethanol (90:10, v/v), commercially available, and the second was NaCl 0.9% (saline): ethanol (92:8, v/v). The mean of the corrected radiochemical yields corresponded to 27% ± 7% for elution with water and ethanol and to 23% ± 3% for elution with saline and ethanol, which could indicate that the eluent solutions have similar elution strength. Besides, quality control results were in accordance with the requirements and demonstrated that there was no significant difference between both formulations. Considering that pharmaceutical preparations containing ethanol should be preferentially diluted with saline to avoid hemolysis, the eluent saline:ethanol (92:8, v/v) was chosen for [18F]FLT extraction and final formulation. 展开更多
关键词 [18F]FLT Synthesis Quality Control Formulation elution RADIOPHARMACEUTICAL
下载PDF
ELUTION OF TUNGSTEN BY SODIUM COMPOUNDS AND ACCELERATION EFFECTS OF COEXISTENT COUNTER IONS IN MIXED ELUANT
7
作者 Wan Linsheng Deng Zuoguo 《Chinese Journal of Reactive Polymers》 1995年第1期1-7,共7页
The elution of WO ions by NaOH. NaNO3 NaCl and NH4Cl on strong basicanion exchange resins in quaternary ammonium form I and the adsorption properties after elution were studied. In addition, the elution curse, the per... The elution of WO ions by NaOH. NaNO3 NaCl and NH4Cl on strong basicanion exchange resins in quaternary ammonium form I and the adsorption properties after elution were studied. In addition, the elution curse, the permeation curveand the exchange capacities of operation were presented. The eluate containingtungsten with high content and excessive eluant of low content were obtained by employing the process of eluting using mixed solution of NaCl and NaOH. It's possible to obtain Na2WO4. 2H2O with high purity by evaporating and crystallizing theeluate. The results of mixed elution showed that the diffusion coefficients of Cl-.OH- and WO ions in solution or exchange agent varied due to the coexistence ofcounter ions and then the exchange velocity of WO→Cl- and WOe→OH- wasaccelerated. 展开更多
关键词 Strong basic anion exchange resins TUNGSTEN elution Acceleration effects
下载PDF
The Effect of Elution Volume for Immunoprecipitation on m6A-Seq Analysis
8
作者 Yuhui Xu Lize Shen Guolin Li 《Proceedings of Anticancer Research》 2021年第4期1-5,共5页
Objective:To develop a cost-effective method to reduce the time consumption of elution in immunoprecipitation.Methods Two volumes(125μL for Group C and 100μL for Group T)of elution buffer were used to explore whethe... Objective:To develop a cost-effective method to reduce the time consumption of elution in immunoprecipitation.Methods Two volumes(125μL for Group C and 100μL for Group T)of elution buffer were used to explore whether smaller volume could save testing time.Result:Time consumption of elution in Group T was significantly shorter than that in Group C,while the efficiency of eluted m6A-containing fragments and the performance of m^(6)A-Seq as indicated by m6A peak distributions showed no difference between the two groups.Conclusion:A smaller volume of elution buffer was an economical way to reduce time consumption in immunoprecipitation. 展开更多
关键词 m^(6)A-Seq IMMUNOPRECIPITATION elution buffer
下载PDF
Simultaneous elution of polycyclic aromatic hydrocarbons and heavy metals from contaminated soil by two amino acids derived from β-cyclodextrins 被引量:7
9
作者 Chengjian Yang Qingru Zeng +4 位作者 Yunzhong Wang Bohan Liao Jian Sun Hui Shi Xingdou Chen 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第12期1910-1915,共6页
Two highly water-soluble amino acids, which derived from β-CDs, i.e., glutamic acid-β-cyclodextrin (GluCD) and ethylene-diamine- β-cyclodextrin (EDCD), were synthesized and were examined for their effect on sol... Two highly water-soluble amino acids, which derived from β-CDs, i.e., glutamic acid-β-cyclodextrin (GluCD) and ethylene-diamine- β-cyclodextrin (EDCD), were synthesized and were examined for their effect on solubilization of anthracene (ANT), complexation of cadmium (Cd^2+), and elution removal of ANT and Cd^2+ in soil. The results showed that GluCD and EDCD were powerful complexant for ANT and Cd^2+. In the presence of 10 g/L GIuCD and EDCD, the solubilization of ANT increased by 47.04 and 23.85 times compared to the control, respectively. GluCD resulted in approximately 90% complexation of Cd^2+ while 70% complexation was observed for EDCD. Simultaneously, GluCD and EDCD could greatly enhance the elution removal of ANT and Cd^2+ from soil. GluCD resulted in the highest elution efficiency of ANT and Cd^2+. With the addition of 10 g/L GluCD, 53.5% of ANT and 85.6% of Cd^2+ were eluted, respectively. The ANT had a negligible effect on the Cd^2+ removal due to different complexing sites of ANT and Cd^2+, while Cd^2+ enhanced the ANT removal under the addition of GluCD because Cd^2+ neutralized the -COOH group of GIuCD. Adversely, the removal of ANT was decreased with Cd^2+ under the addition of EDCD, this was due to the fact that Cd^2+ enhanced the polarity of EDCD molecule and inhibited the complexation between ANT and EDCD. The study suggested that GluCD could be preferred and be successfully applied to remediation of heavy metals or organic compounds in contaminated soil. 展开更多
关键词 anthracene cadmium CYCLODEXTRIN SOLUBILIZATION elution soil
原文传递
Analysis of the Nucleoside Content of Cordyceps sinensis Using the Stepwise Gradient Elution Technique of Thin-Layer Chromatography 被引量:3
10
作者 马敬桦 周福添 吴建勇 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2004年第1期85-91,共7页
Nucleoside is the main class of active components in Cordyceps sinensis. Thin-layer chromatography (TLC) is one of the most commonly used methods in pharmacopoeias for analyzing chemical components of herbal medicine.... Nucleoside is the main class of active components in Cordyceps sinensis. Thin-layer chromatography (TLC) is one of the most commonly used methods in pharmacopoeias for analyzing chemical components of herbal medicine. Since the isocratic elution method cannot be applied successfully in TLC analysis for separating all the nucleoside components, the stepwise gradient elution has been developed in this work to separate eight nucleoside standards with success. In this way, quantitative analyses of the samples of Cordyceps sinensis were achieved via the pro-posed TLC procedure coupled with the scanning densitometric techniques of CAMAG and TLCQA methods for qualitative and quantitative analysis. 展开更多
关键词 thin-layer chromatography Cordyceps sinensis stepwise gradient elution NUCLEOSIDE SOFTWARE quantitative analysis
原文传递
Characteristics of elution profile in radial chromatography under linear conditions 被引量:1
11
作者 Andreas Seidel-Morgenstern 《Science China Chemistry》 SCIE EI CAS 2005年第4期352-360,共9页
Based on the mass balance equations of solute transfer in the radial chroma-tographic column,the theoretical expression to describe the column efficiency and shape of elu-tion profile is obtained under linear isotherm... Based on the mass balance equations of solute transfer in the radial chroma-tographic column,the theoretical expression to describe the column efficiency and shape of elu-tion profile is obtained under linear isotherm case.Moreover,the tendency for the variation of column efficiency and symmetry of peak profile is systematically discussed.The results showed that in radial chromatography the relationship between the column efficiency and volumetric flow rate is similar with that relationship in axial chromatography;relatively high column efficiency still can be obtained under high flow rate in radial chromatography.Accompanying the increase of retention factor of solutes and injection time,the column efficiency decreases monotonously.The effect of column diameter and column length on the column efficiency interfere with each other.It is more advantageous to increase the column efficiency by applying columns with larger column diameter and shorter column length.According to the discussion of the effect of diffusion on the column efficiency,radial chromatography is proved to be suitable for the separation of samples with relatively high diffusion coefficient,which predicts its obvious advantage in the preparative separation of samples such as proteins and DNA. 展开更多
关键词 RADIAL chromatography COLUMN efficiency elution profile symmetry.
原文传递
Superficial femoral artery pseudoaneurysm at implantation site of drug eluting stent discovered due to bacteremia:A case report
12
作者 Takafumi Akai Shintarou Ninomiya Takanori Kaneko 《World Journal of Clinical Cases》 SCIE 2024年第17期3194-3199,共6页
BACKGROUND Drug-eluting stents(DES)are used to treat lower extremity arterial disease.During DES treatment,aneurysmal degeneration occasionally occurs,especially with fluoropolymer-based DES.However,the incidence of p... BACKGROUND Drug-eluting stents(DES)are used to treat lower extremity arterial disease.During DES treatment,aneurysmal degeneration occasionally occurs,especially with fluoropolymer-based DES.However,the incidence of pseudoaneurysms after DES placement is rarely reported in the lower extremity region,although there have been several reports on pseudoaneurysm formation after DES placement in the coronary artery region.CASE SUMMARY We report the case of a 64-year-old man who presented with fever and pain in his left hand after dialysis.Bacteremia was diagnosed by blood culture,and after admission,he developed pain on the medial side of the right thigh.A pseudoaneurysm was observed in the right superficial femoral artery(SFA)at the proximal end of a previously placed DES.The bacteremia was thought to have been caused by a pseudoaneurysm of the left superficial brachial artery,and the pseudoaneurysm of the left superficial brachial artery was removed after antibiotic treatment.The pseudoaneurysm of the right SFA rapidly expanded after admission,but the expansion rate was reduced after infection control.Seven months after the first admission,the pseudoaneurysm of the left SFA was re-moved and in situ revascularization performed using a rifampicin-soaked Dacron graft.CONCLUSION Although pseudoaneurysm after DES placement in the lower extremity region is rare,it must be considered in patients with bacteremia. 展开更多
关键词 PSEUDOANEURYSM Drug eluting stent Superficial femoral artery BACTEREMIA REVASCULARIZATION Case report
下载PDF
Effects of ion elution on formation of ice core record
13
作者 Huang, CL Li, ZQ +1 位作者 Hou, SG Pu, JC 《Chinese Science Bulletin》 SCIE EI CAS 1997年第3期236-239,共4页
PREVIOUS studies have shown that 50%—80% of the pollutant load in the snowpacks can be released with the first 30% of the meltwater. So the ion elution can alter the seasonal-layer distribution of chemical contents d... PREVIOUS studies have shown that 50%—80% of the pollutant load in the snowpacks can be released with the first 30% of the meltwater. So the ion elution can alter the seasonal-layer distribution of chemical contents deposited in the snowpacks and form a new chemical distribution, which is preserved perpetually as the ice core record. In order to reconstruct the paleoclimate and paleo-environment from the ice core with high accuracy, it is necessary to determine the correlation of the chemical distribution between pre- and post-ion elution processes. 展开更多
关键词 ION elution ICE CORE RECORD chemical distribution.
原文传递
THE SIMULATION AND OPTIMIZATION OF GRADIENT ELUTION HPLC
14
作者 林炳承 刘文烨 +3 位作者 卢佩章 D.L.MASSART M.DE.SMET B.KOPPENHOEFER 《Science China Chemistry》 SCIE EI CAS 1992年第9期1056-1066,共11页
The movement of a particular component along an HPLC column is studied on the ba-sis of equilibrium equations. Numerical simulation of multi--step gradient elution HPLC isperformed by means o? a personal computer prog... The movement of a particular component along an HPLC column is studied on the ba-sis of equilibrium equations. Numerical simulation of multi--step gradient elution HPLC isperformed by means o? a personal computer program. The location x, as a fraction of thecolumn length, for a given time t o? each compound is calculated, the velocity and corre-sponding acceleration are given as well. Diagrams for x,dx/dt and d^2x/dt^2 versus t display themovement process of the different components along the HPLC column during gradient elu-tion. The prediction of the retention time and peak width, and the optimization for the multi-step gradient elution HPLC are all based on such simulation and the molecular structure ofthe. components is separated as well. 展开更多
关键词 HPLC MULTI-STEP gradient elution simulation in HPLC COLUMN optimization separation of CHIRAL DRUGS
原文传递
Steady-migration retention characteristics of peptides under gradient elution: application towards a dynamic separation method for minor-adjustments of the retention of peptides in RPLC
15
作者 Min Li Yongjun Lu +5 位作者 Yicong Yang Jianjun Li Lili Wang Wei Tuo Xiaohui Ning Xin-Du Geng 《Science China Chemistry》 SCIE EI CAS CSCD 2017年第6期829-836,共8页
Minor-adjustment of the retention of peptides, induced by varying the mobile phase flow-rate(MPF-R), is a new dynamic separation method for simultaneously and rapidly identifying and improving the selectivity of hidde... Minor-adjustment of the retention of peptides, induced by varying the mobile phase flow-rate(MPF-R), is a new dynamic separation method for simultaneously and rapidly identifying and improving the selectivity of hidden and overlapping peptide peaks. It can also-stabilize the reverse elution order of some pair-peaks under gradient elution in reverse phase liquid chromatography. The retention characteristics of peptides under gradient elution in RPLC was firstly found to be dominated by two variables of the steady region(SR) and migration region(MR). The changes in peptide retention induced by varying the MPF-R can be attributed to changes in the rate of bond breaking of multiple molecular interactions of peptides from the SR and of the mass transfer of peptides from the stationary phase to the mobile phase in the MR. The two dynamic variables were also found to independently depend on the type of peptide. Desirable results were obtained using six standard oligopeptides and a real sample of trypsin-digested lysozyme.It is expected that the quality control of peptide drugs, high dispersion of peptide peaks in peptide mapping and "bottom-up MS"in proteomics will be improved by this method, even enabling peptide purification on a preparative scale in industry. 展开更多
关键词 steady-migration retention liquid chromatography PEPTIDES dynamic separation minor-adjustment of retention elution orders
原文传递
Prediction of Retention Time of Solutes under Linear Gradient Elution Conditions in RP-HPLC
16
作者 杨更亮 田宝娟Department of Chemistry +3 位作者 Normal College of Baoding Baoding 陈义 王德先 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2003年第8期1084-1087,共4页
A model for predicting retention time of solutes under linear gradient elution conditions has been established. In this model, the theoretical expressions under different elution modes were derived and tested with the... A model for predicting retention time of solutes under linear gradient elution conditions has been established. In this model, the theoretical expressions under different elution modes were derived and tested with the retention behaviors of p hydroxybenzaldehyde, vanillin, biphenyl, phenanthrene in gradient elution. With taking into account the dwell time of the instrumental system, the theoretically predicted retention times agree well with those experimentally determined. 展开更多
关键词 high performance liquid chromatography gradient elution retention time prediction
原文传递
A simple and sensitive gradient elution liquid chromatography with tandem mass spectrometry(LC-MS/MS) method for the quantification of doxorubicin in rabbit plasma
17
作者 Jialin Li Liying Guo +1 位作者 Xiaoya Qin Tianyuan Fan 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2016年第8期576-581,共6页
In the present study, we developed and validated a simple and sensitive gradient elution liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of doxorubicin in rabbit plasma. Daunorubi... In the present study, we developed and validated a simple and sensitive gradient elution liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of doxorubicin in rabbit plasma. Daunorubicin was used as an internal standard (IS). The doxorubicin and IS were extracted with ethyl acetate from plasma samples. The chromatographic separations were achieved on a C18 column (2.1 mm×50 mm, 2.5μm) configured with a C18 guard column (2.1 mm×10 mm, 2.5 μm). The mobile phase of 0.1% formic acid-water solution and acetonitrile was delivered using a gradient elution program at a flow rate of 0.4 mL/min. The temperature for column was maintained at 40 ℃. The electrospray ionization (ESI) source was operated in the positive ion mode, and the quantification was conducted using multiple reaction monitoring (MRM) of the transitions m/z 544.07→396.96 and m/z 528.06→321.05 for doxorubicin and IS, respectively. The calibration curve of doxorubicin was linear (r 〉 0.999) within the range of 2-600 ng/mL. The lower limit of quantification was 2 ng/mL. The relative errors of intra-day and inter-day accuracies ranged from -2.48% to 0.18% and from -3.78% to 1.94%, respectively. The relative standard deviations of intra-day and inter-day precisions were less than 8.65% and 6.41%, respectively. The method exhibited satisfactory results in terms of specificity, sensitivity, matrix effect, recovery and stability. The newly developed LC-MS/MS method was reliable to monitor doxorubicin concentrations in rabbit plasma. 展开更多
关键词 DOXORUBICIN LC-MS/MS Gradient elution Rabbit plasma
原文传递
A high-efficiency pretreatment method for elution of pathogenic bacteria in lettuce
18
作者 Xiaoyan Liao Chunmin Pu +3 位作者 Yan Cui Yalong Bai Xianming Shi Lili Chen 《Food Quality and Safety》 SCIE CSCD 2022年第4期588-596,共9页
Many current studies on rapid detection of pathogenic bacteria in foods have focused on the construction of detection methods,neglecting pretreatment.It is also a key step to efficiently elute pathogenic bacteria from... Many current studies on rapid detection of pathogenic bacteria in foods have focused on the construction of detection methods,neglecting pretreatment.It is also a key step to efficiently elute pathogenic bacteria from food samples for rapid detection and can even determine the success or failure of an assay.In this study,we used Escherichia coli(E.coli),Salmonella enteritidis(S.enteritidis),and Listeria monocytogenes(L.monocytogenes)as model bacteria to compare the elution efficiency of different eluants;explore the effect of surfactant,ionic strength,protein(or amino acid and peptide),and enzyme on the recovery rate of bacteria in lettuce;and compare the compound effect caused by multiple factors.Finally,we developed an efficient bacterial recovery method and confirmed the superiority of this method to analyze the bacterial diversity of eluants from lettuce.The results showed that the recovery efficiency of E.coli,S.enteritidis,and L.monocytogenes,which were artificially contaminated with approximately 10^(5)CFU/g in lettuces,could reach 94.4%,90.6%,and 93.7%by using 10 mmol/L Tris·HCl(pH 9.5)with 0.1%peptone and 300 U/100 mL of cellulase,and furthermore,the elution efficiency could reach 99.6%,98.6%,and 100%with the aid of a 2-min stomaching.For the lettuce samples with only native bacteria,the recovery rate reached 92.1%for viable aerobic bacteria by this method,which was approximately 10%higher than that of the modified previous method.The bacterial diversity of the eluted solution was analyzed,and the result was significantly improved.Considering these advantages,it is important to improve the elution efficiency to achieve rapid and accurate detection of pathogenic bacteria in lettuces. 展开更多
关键词 LETTUCE foodborne pathogens elution PRETREATMENT diversity analysis
原文传递
A novel method through solid phase extraction combined with gradient elution for concentration and separation of 66(ultra)trace persistent toxic pollutants in Antarctic waters
19
作者 Li Zhang Guang-Shui Na +5 位作者 Chun-Xiang He Rui-Jing Li Hui Gao Lin-Ke Ge Yan-Jie Wang Yao Yao 《Chinese Chemical Letters》 SCIE CAS CSCD 2016年第3期405-411,共7页
This study developed a method to perform the simultaneous concentration and selective separation of 66 (ultra) trace persistent toxic substances in Antarctic waters. The substances included 30 polychlorinated biphen... This study developed a method to perform the simultaneous concentration and selective separation of 66 (ultra) trace persistent toxic substances in Antarctic waters. The substances included 30 polychlorinated biphenyls, 17 organochlorine pesticides, 16 polycyclic aromatic hydrocarbons, 3 hexabromocyclododecanes. Solid phase extraction was performed using a C18 membrane and silica gel column. Gradient elution was conducted using organic solvents with different polarities; as a result, the efficiency of the C18 film is improved and the interferences from impurities and target compounds are eliminated. Extracts were subsequently analyzed through gas chromatography or liquid and gas chromatography coupled to tandem mass spectrometry. Method validation yielded the following values: recoveries of all target analytes in the Antarctic water ranged from 87.3% to 117.6% and reproducibility as percent relative standard deviation was lower than 5%. Quantification limits ranged from 0.004 μg L^-1 to 0.030 μg L^-1. The established method improved the recoveries and reduced the limits of detection. Results indicated the method exhibited good performance in the simultaneous concentration and selective separation of 66 (ultra) trace organic pollutants; Therefore, the proposed sample pretreatment can potentially eliminate the effects of various classes of impurities to some extent. 展开更多
关键词 Polychlorinated biphenyls(PCBs) Organochlorine pesticides(OCPs) Polycyclic aromatic hydrocarbons(PAHs) Hexabromocyclododecanes(HBCDs) Solid phase extraction(SPE) Gradient elution
原文传递
The principle of optimization of binary mobile phase composition of multi-step linear gradient elution
20
作者 ZOU Han-Fa ZHANG Yu-Kui +2 位作者 DONG Li-Fu BAO Mian-Sheng LU Pei-Zhang 《Acta Chimica Sinica English Edition》 SCIE CAS CSCD 1989年第6期511-519,共1页
The basic principle of optimal method called “moving overlapping resolution mapping Method” to select the optimal binary mobile phase composition of multi-step linear gradient liquid chromatography is discussed with... The basic principle of optimal method called “moving overlapping resolution mapping Method” to select the optimal binary mobile phase composition of multi-step linear gradient liquid chromatography is discussed with simultaneously considering effects of position of solute inside the column and mobile phase composition on peak resolution and retention value, then a BASIC program based on this principle is developed in IBM-PC computer. The validities of both principle of optimization and BASIC program are confirmed by separation of samples Containing bile acids and PAHs in RP-HPLC. 展开更多
关键词 time LENGTH The principle of optimization of binary mobile phase composition of multi-step linear gradient elution
全文增补中
上一页 1 2 6 下一页 到第
使用帮助 返回顶部