[Objectives] This study was conducted to optimize the extraction process of protocatechuic acid from Emilia sonchifolia DC. [Methods] The optimal extraction conditions were determined by single factor,response surface...[Objectives] This study was conducted to optimize the extraction process of protocatechuic acid from Emilia sonchifolia DC. [Methods] The optimal extraction conditions were determined by single factor,response surface analysis and variance analysis,and the content of protocatechuic acid was determined by HPLC. [Results] The protocatechuic acid standard curve equation was: y = 1 435 x + 8 403,R^2= 0. 999 8,indicating a good linear relationship. The optimal extraction conditions were as follows: a temperature at 80 ℃,an extraction time of 1 h,a material-to-liquid ratio at 1:10 and an ultrasonic power of 600 W,and the content of protocatechuic acid extracted was 1. 93 mg/g. The method showed a RSD of 0. 41%,less than 2%,and the detection limit was 0. 0000047261 g/ml.The experimental sample X1 was the low-level 0. 1 mg/ml standard solution,which showed recovery of protocatechuic acid between 100.8% and 105.2%,with a RSD of 0. 013%;and the sample X2 was the high-level 1. 0 mg/ml standard solution,which exhibited recovery between 100. 6% and 102. 2%,with a RSD of 0.076%. Thus,the recovery was high,and the requirements of the performance index were met. [Conclusions] The detection method is stable and reliable and can produce satisfactory results.展开更多
基金Supported by Basic and Applied Basic Research Plan of Hainan Province in2019 (2019RC245)Natural Science Foundation of Hainan Province in 2017(217157)。
文摘[Objectives] This study was conducted to optimize the extraction process of protocatechuic acid from Emilia sonchifolia DC. [Methods] The optimal extraction conditions were determined by single factor,response surface analysis and variance analysis,and the content of protocatechuic acid was determined by HPLC. [Results] The protocatechuic acid standard curve equation was: y = 1 435 x + 8 403,R^2= 0. 999 8,indicating a good linear relationship. The optimal extraction conditions were as follows: a temperature at 80 ℃,an extraction time of 1 h,a material-to-liquid ratio at 1:10 and an ultrasonic power of 600 W,and the content of protocatechuic acid extracted was 1. 93 mg/g. The method showed a RSD of 0. 41%,less than 2%,and the detection limit was 0. 0000047261 g/ml.The experimental sample X1 was the low-level 0. 1 mg/ml standard solution,which showed recovery of protocatechuic acid between 100.8% and 105.2%,with a RSD of 0. 013%;and the sample X2 was the high-level 1. 0 mg/ml standard solution,which exhibited recovery between 100. 6% and 102. 2%,with a RSD of 0.076%. Thus,the recovery was high,and the requirements of the performance index were met. [Conclusions] The detection method is stable and reliable and can produce satisfactory results.