BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To inves...BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice.展开更多
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod...BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs.展开更多
BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive in...BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive intraluminal hemorrhage.CASE SUMMARY A 67-year-old man was hospitalized for coffee ground vomiting,tarry stools,and colic abdominal pain.He was repeatedly admitted for active GI bleeding and hypovolemic shock.Intermittent and spontaneously stopped bleeders were undetectable on multiple GI endoscopy,angiography,computed tomography angiography(CTA),capsule endoscopy,and ^(99)mTc-labeled red blood cell(RBC)scans.The patient received supportive treatment and was discharged without signs of rebleeding.Thereafter,he was re-admitted for bleeder identification.Repeated CTA after a bleed revealed a small aortic aneurysm at the renal level contacting the fourth portion of the duodenum.A ^(99)mTc-labeled RBC singlephoton emission CT(SPECT)/CT scan performed during bleeding symptoms revealed active bleeding at the duodenal level.According to his clinical symptoms(intermittent massive GI bleeding with hypovolemic shock,dizziness,dark red stool,and bloody vomitus)and the abdominal CTA and ^(99)mTc-labeled RBC SPECT/CT results,we suspected a small aneurysm and an aortoduodenal fistula.Subsequent duodenal excision and duodenojejunal anastomosis were performed.A 7-mm saccular aneurysm arising from the anterior wall of the abdominal aorta near the left renal artery was identified.Percutaneous intravascular stenting of the abdominal aorta was performed and his symptoms improved.CONCLUSION Our findings suggest that ^(99)mTc-labeled RBC SPECT/CT scanning can aid the diagnosis of a rare cause of active GI bleeding.展开更多
BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-...BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy.展开更多
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC...AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy.展开更多
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com...AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of > 1000 mL.展开更多
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th...The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.展开更多
This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the r...This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pailidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients.展开更多
BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical chal...BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19,thus improving patient access.AIM To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography(SPECT/CT)in order to optimize therapy.METHODS All patients were selected for Y-90 RE through a multidisciplinary tumor board,and were screened and tested for COVID-19 infection per institutional protocol.A same day procedure was developed,consisting of angiography,imaging,and Y-90 resin particle delivery.Routine SPECT/CT after technetium-99m macroaggregated albumin(Tc-99m MAA)administration was performed for assessment of arterial supply,personalized dosimetry,and extrahepatic activity.Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery,by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles.RESULTS A total of 14 patients underwent same day Y-90 RE between March and June 2020.Mean lung shunt fraction was 6.13%(range 3.5%-13.1%).Y-90 RE was performed for a single lesion in 7 patients,while the remaining 7 patients had treatment of multifocal lesions.The largest lesion measured 8.3 cm.All patients tolerated the procedure well and were discharged the same day.CONCLUSION Same day Y-90 RE with resin-based microspheres is feasible,and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond.We recommend consideration of SPECT/CT,especially among patients with complex malignancies,for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE.展开更多
BACKGROUND Alveolar soft part sarcoma(ASPS)is an extremely rare malignant sarcoma,accounting for less than 1%of all soft-tissue sarcomas.However,limited information is available on multimodal imaging[computed tomograp...BACKGROUND Alveolar soft part sarcoma(ASPS)is an extremely rare malignant sarcoma,accounting for less than 1%of all soft-tissue sarcomas.However,limited information is available on multimodal imaging[computed tomography(CT),magnetic resonance imaging(MRI),and positron emission computed tomography/computed tomography(PET/CT)]of ASPS.CASE SUMMARY This study reports a case of a 35-year-old female patient with ASPS of the left thigh with lung metastasis.The patient presented with a 1-year history of a palpable mass in the lower extremity,which exhibited rapid growth for 3 wk.CT,MRI,and F-deoxyglucose PET/CT examinations were performed.CT showed a slightly hypodense or isodense mass with patchy calcifications.On MRI examination,the mass manifested hyperintensity on T1-weighted,T2-weighted,and diffusion-weighted images with some signal voids.PET/CT images demonstrated an intensely hypermetabolic mass in the left thigh and hypermetabolic nodules in lungs.CONCLUSION ASPS should be considered as a possible diagnosis when a slow-growing mass is detected in the soft tissue of the extremities,with hyperintensity and numerous signal voids on T1-weighted,T2-weighted,and diffusion-weighted images and intense F-deoxyglucose uptake on PET/CT.ASPS can have calcifications on CT.展开更多
BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopami...BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopamine levels or metabolic activity of the corpus striatum. OBJECTIVE: To validate the effects of STN DBS on dopamine metabolism and glucose metabolism in the corpus striatum of hemiparkinsonian monkeys using single photon emission computed tomography (SPECT) and position emission tomography (PET). DESIGN, TIME AND SET'rING: A controlled animal study was performed at the Neurosurgery Laboratory, Changhai Hospital of the Second Military Medical University of Chinese PLA between January 2004 and December 2007. METHODS: Hemiparkinsonism was induced in adult Rhesus Macaque monkeys, which exhibit similar characteristics of PD in humans, through unilateral internal carotid artery infusion of 1-methy-4-phenyl-1, 2, 3, 6-tetrahydropyrindine. Following model establishment, stimulation electrodes were implanted in the right STN, and chronic high-frequency stimulation (60 μs pulse width, 130 Hz frequency, and 1.5-2.0 V pressure) was performed. MAIN OUTCOME MEASURES: The changes in dopamine transporter (DAT), D2 receptor (D2R), and glucose metabolism in the corpus striatum following STN DBS were observed using SPECT and PET. RESULTS: SPECT examination showed that DAT specific binding in the right corpus striatum was increased at 3 months after DBS compared with prior to stimulation, and D2R specific binding in the right corpus striatum gradually decreased near levels on the left (non-electrode-implanted) side within 3 months after DBS. PET examination showed that the glucose metabolism in the right corpus striatum was markedly increased at 3 months after effective DBS. Hemiparkinsonism monkeys showed improved left limb rigidity, increased activities, and stable gait under chronic high-frequency stimulation. CONCLUSION: STN DBS increased striatal DAT, decreased D2R, and enhanced glucose metabolism, suggesting that chronic, high-frequency STN stimulation enhanced the metabolic activity of the corpus striatum, a mechanism for improving the PD symptoms of hemiparkinsonian monkeys.展开更多
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa...Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.展开更多
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim...BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment.展开更多
To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspecte...To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspected CAD were enrolled in the prospective study. All patients underwent myocardial perfusion scintigraphy in SPECT with dual isotopes of T1-201 and dipyridamole stress Tc-99m sestamibi. Rest and stress imaging protocol were performed in 2 hours by dose of 3 mCi TI-201 and 25 mCi Tc-99m sestamibi. The acquisition parameters includes LEHR collimator, energy peak of 72 and 167 keV for T1-201 and 140 keV for Tc-99m, 180-degree rotation from RAO to LPO, matrix size 64x64, and 25second/frame/64 frames. The 20-segment model of left ventricle was used in automatic quantitation software. Coronary angiography was used as gold standard. CAD was defined as 50% of lumen stenosis on coronary angiography. Rest TI-201/stress tc-99m sestamibi dual-isotope SPECT demonstrated a sensitivity of 94.59% and specificity of 70%, positive predictive value of 79.54% and negative predictive value of 91.3% in detection of coronary artery disease. Sensitivity and specificity for detecting multi-vessel coronary artery disease were 82.75% and 81.57% for the left anterior descending, 77.77% and 91.83% for left circumflex and 94.11% and 82% for right coronary artery. 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT has high sensitivity, specificity, positive predictive value and negative predictive value in detecting chronic coronary artery disease with greater than 50% stenosis assessed by coronary angiography Moreover, this imaging protocol gives high imaging quality, time-saving and convenience.展开更多
BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-...BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-old woman with a 4-wk history of daily fevers was admitted to our hospital.A whole body^(18)-Fluordesoxyglucose(PET-FDG)positron emission tomography/computed tomography(PET/CT)was performed to elucidate the source of the fever.However,whole body^(18)-FDG PET/CT raised the suspicion of a malignant lesion because of peripheral FDG accumulation(SUVmax 3.5 g/mL)higher than that of the normal liver parenchyma(SUVmax 1.6 g/mL)surrounding a hypoactive area,and no other abnormalities were showed.Subsequently,the patient underwent liver mass resection.Histopathology showed a hepatic cavernous hemangioma with fatty infiltration around the lesion.The fever disappeared four days after surgery and the patient did not present any complications during follow-up.CONCLUSION Fatty infiltration in the peripheral parts of hepatic cavernous hemangioma may lead to subacute inflammation which further activate the Kupffer cells.This may cause prolonged fever and peripheral rim FDG accumulation on PET/CT.展开更多
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi...Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.展开更多
BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated wit...BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated with infection,based on increased glucose utilization by activated macrophages and granulocytes.Aseptic vascular grafts,like all foreign bodies,can stimulate an inflammatory response,which can present as increased activity on 18F-FDG PET/CT.Consequently,distinguishing aseptic inflammation from graft infection,though important,can be difficult.In the case of endovascular aneurysm repair(EVAR),a minimally invasive procedure involving the transfemoral insertion of an endoprosthetic stent graft,the normal postoperative appearance of these grafts on 18F-FDG PET/CT can vary over time,potentially confounding study interpretation.AIM To investigate the visual,semiquantitative,and temporal characteristics of aseptic vascular grafts in patients status post EVAR.METHODS In this observational retrospective cohort study,patients with history of EVAR who underwent 18F-FDG PET/CT for indications other than infection were identified retrospectively.All patients were asymptomatic for graft infection-no abdominal pain,fever of unknown origin,sepsis,or leukocytosis-at the time of imaging and for≥2 mo after each PET/CT.Imaging studies such as CT for each patient were also reviewed,and any patients with suspected or confirmed vascular graft infection were excluded.One hundred two scans performed on 43 patients(34 males;9 females;age=77±8 years at the time of the final PET/CT)were retrospectively reviewed.All 43 patients had an abdominal aortic(AA)vascular graft,40 patients had a right iliac(RI)limb graft,and 41 patients had a left iliac(LI)limb graft.Twentytwo patients had 1 PET/CT and 21 patients had from 2 to 9 PET/CTs.Grafts were imaged between 2 mo to 168 mo(about 14 years)post placement.Eight grafts were imaged within 6 mo of placement,including three that were imaged within three months of placement.The mean interval between graft placement and PET/CT for all 102 scans was 51±39 mo.PET/CT data was reconstructed with region-of-interest analysis of proximal,mid and distal portions of the grafts and background ascending aorta.Maximum standardized uptake value(SUVmax)was recorded for each region.SUVmax-to-background uptake ratios(URs)were calculated.Visual assessment was performed using a 2-pattern grading scale:Diffuse(homogeneous uptake less than liver uptake)and focal(one or more areas of focal uptake in any part of the graft).Statistical analysis was performed.RESULTS In total,there were 306 AA grafts,285 LI grafts,282 RI grafts,and 306 ascending aorta background SUVmax measurements.For all 102 scans,mean SUVmax values for AA grafts were 2.8-3.0 along proximal,mid,and distal segments.Mean SUVmax values for LI grafts and RI grafts were 2.7-2.8.Mean SUVmax values for background were 2.5±0.5.Mean URs were 1.1-1.2.Visual analysis of the scans reflected results of quantitative analysis.On visual inspection,98%revealed diffuse,homogeneous 18F-FDG uptake less than liver.Graft URs and visual pattern categories were significantly associated for AA graft URs(F-ratio=21.5,P<0.001),LI graft URs(F-ratio=20.4,P<0.001),and RI graft URs(F-ratio=30.4,P<0.001).Thus,visual patterns of 18F-FDG uptake corresponded statistically significantly to semiquantitative URs.The age of grafts showing focal patterns was greater than grafts showing diffuse patterns,87±89 vs 50±37 mo,respectively(P=0.02).URs were significantly associated with graft age for AA grafts(r=0.19,P=0.001).URs were also significantly associated with graft age for LI grafts(r=0.25,P<0.0001),and RI grafts(r=0.31,P<0.001).Quartiles of similar numbers of graft(n=25-27)grouped by graft age indicated that URs were significantly higher for 4th quartile vs 2nd quartile URs(F-ratio=19.5,P<0.001).When evaluating URs,graft SUVmax values within 10%-20%of the ascending aorta SUVmax is evident in aseptic grafts,except for grafts in the oldest quartiles.In this study,grafts in the oldest quartiles(>7 years post EVAR)showed SUVmax up to 30%higher than the ascending aorta SUVmax.CONCLUSION Characteristics of an aseptic vascular stent graft in the aorta and iliac vessels on 18F-FDG PET/CT include graft SUVmax values within 10%-20%of the ascending aorta background SUVmax.The SUVmax of older aseptic grafts can be as much as 30%above background.The visual uptake pattern of diffuse,homogeneous uptake less than liver was seen in 98%of aseptic vascular grafts,making this pattern particularly reassuring for clinicians.展开更多
Parkinson disease(PD)is the second-most common neurodegenerative disorder.Its main pathological mechanism is the selective degeneration and deletion of dopaminergic neurons in the dense part of the substantia nigra an...Parkinson disease(PD)is the second-most common neurodegenerative disorder.Its main pathological mechanism is the selective degeneration and deletion of dopaminergic neurons in the dense part of the substantia nigra and the damage of dopaminergic neurons caused by the abnormal deposition of a Lewy body,leading to a decreased dopamine level.Positron emission computed tomography(PET)/single photon emission computed tomography(SPECT)is a molecular imaging technology that can directly or indirectly reflect changes in molecular levels by using a specific tracer.With the research and development on the tracers of related enzymes for labeling dopamine transporter and dopamine receptor and for being involved in dopamine formation,this imaging technology has been applied to all aspects of PD research.It not only contributes to clinical work but also provides an important theoretical basis for exploring the pathological mechanism of PD at a molecular level.Therefore,this review discusses the application value of PET/SPECT in PD in terms of early diagnosis,disease severity evaluation,clinical manifestations,differential diagnosis,and pathological mechanism.展开更多
Objective:To explore the effectiveness of electro-acupuncture(EA)in the treatment of childhood autism(CA)and evaluate its effectiveness using single photon emission computed tomography(SPECT).Methods:A total o...Objective:To explore the effectiveness of electro-acupuncture(EA)in the treatment of childhood autism(CA)and evaluate its effectiveness using single photon emission computed tomography(SPECT).Methods:A total of 55 CA patients(4.52±2.73 years)were enrolled in this study.All patients received EA treatments and were examined by SPECT before and after treatments.Results:Following treatment,the intracerebral multiple focal radioactivity distribution defect areas of CA patients were observed to be partially filled.Specifically,significant differences in the ratios of regional cerebral blood flow and global cerebral blood flow before(Fb)and after(Fe)EA treatment in different lesions were observed(in the left prefrontal cortex,t=5.01,P〈0.01;in the right prefrontal cortex,t=2.32,P〈0.05;in the left temporal lobe,t=4.54,P〈0.01;in the right temporal lobe,t=2.90,P〈0.05;in the left Broca’s area,t=5.82,P〈0.01).After EA treatment,the patients exhibited symptomatic relief.Conclusion:EA is useful to treat CA and SPECT can be used to evaluate the effectiveness of this treatment.展开更多
Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) ...Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) can depict many of the lesions depicted with a PET scanner in the lungs, which is used in place of PET-CT for discriminating malignant from benign pulmonary nodules in many studies. However, DHC-SPECT has inevitable false-negative results because the sensitivity for small lesions less than 2.0 cm is limited, and has high false-positive rate for active inflammatory nodules. Furthermore,DHC-SPECT also has a considerably higher cost ($300 in China) than other imaging examination.展开更多
文摘BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice.
文摘BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs.
文摘BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive intraluminal hemorrhage.CASE SUMMARY A 67-year-old man was hospitalized for coffee ground vomiting,tarry stools,and colic abdominal pain.He was repeatedly admitted for active GI bleeding and hypovolemic shock.Intermittent and spontaneously stopped bleeders were undetectable on multiple GI endoscopy,angiography,computed tomography angiography(CTA),capsule endoscopy,and ^(99)mTc-labeled red blood cell(RBC)scans.The patient received supportive treatment and was discharged without signs of rebleeding.Thereafter,he was re-admitted for bleeder identification.Repeated CTA after a bleed revealed a small aortic aneurysm at the renal level contacting the fourth portion of the duodenum.A ^(99)mTc-labeled RBC singlephoton emission CT(SPECT)/CT scan performed during bleeding symptoms revealed active bleeding at the duodenal level.According to his clinical symptoms(intermittent massive GI bleeding with hypovolemic shock,dizziness,dark red stool,and bloody vomitus)and the abdominal CTA and ^(99)mTc-labeled RBC SPECT/CT results,we suspected a small aneurysm and an aortoduodenal fistula.Subsequent duodenal excision and duodenojejunal anastomosis were performed.A 7-mm saccular aneurysm arising from the anterior wall of the abdominal aorta near the left renal artery was identified.Percutaneous intravascular stenting of the abdominal aorta was performed and his symptoms improved.CONCLUSION Our findings suggest that ^(99)mTc-labeled RBC SPECT/CT scanning can aid the diagnosis of a rare cause of active GI bleeding.
文摘BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy.
文摘AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy.
文摘AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of > 1000 mL.
基金supported by the National 973 Program of China,No.2006CB504505the National Natural Science Foundation of China,No.90709027
文摘The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.
基金support of the Pusan National University Research Grant for 2 years
文摘This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pailidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients.
文摘BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19,thus improving patient access.AIM To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography(SPECT/CT)in order to optimize therapy.METHODS All patients were selected for Y-90 RE through a multidisciplinary tumor board,and were screened and tested for COVID-19 infection per institutional protocol.A same day procedure was developed,consisting of angiography,imaging,and Y-90 resin particle delivery.Routine SPECT/CT after technetium-99m macroaggregated albumin(Tc-99m MAA)administration was performed for assessment of arterial supply,personalized dosimetry,and extrahepatic activity.Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery,by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles.RESULTS A total of 14 patients underwent same day Y-90 RE between March and June 2020.Mean lung shunt fraction was 6.13%(range 3.5%-13.1%).Y-90 RE was performed for a single lesion in 7 patients,while the remaining 7 patients had treatment of multifocal lesions.The largest lesion measured 8.3 cm.All patients tolerated the procedure well and were discharged the same day.CONCLUSION Same day Y-90 RE with resin-based microspheres is feasible,and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond.We recommend consideration of SPECT/CT,especially among patients with complex malignancies,for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE.
文摘BACKGROUND Alveolar soft part sarcoma(ASPS)is an extremely rare malignant sarcoma,accounting for less than 1%of all soft-tissue sarcomas.However,limited information is available on multimodal imaging[computed tomography(CT),magnetic resonance imaging(MRI),and positron emission computed tomography/computed tomography(PET/CT)]of ASPS.CASE SUMMARY This study reports a case of a 35-year-old female patient with ASPS of the left thigh with lung metastasis.The patient presented with a 1-year history of a palpable mass in the lower extremity,which exhibited rapid growth for 3 wk.CT,MRI,and F-deoxyglucose PET/CT examinations were performed.CT showed a slightly hypodense or isodense mass with patchy calcifications.On MRI examination,the mass manifested hyperintensity on T1-weighted,T2-weighted,and diffusion-weighted images with some signal voids.PET/CT images demonstrated an intensely hypermetabolic mass in the left thigh and hypermetabolic nodules in lungs.CONCLUSION ASPS should be considered as a possible diagnosis when a slow-growing mass is detected in the soft tissue of the extremities,with hyperintensity and numerous signal voids on T1-weighted,T2-weighted,and diffusion-weighted images and intense F-deoxyglucose uptake on PET/CT.ASPS can have calcifications on CT.
基金the National Natural Science Foundation of China,No.30471776
文摘BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopamine levels or metabolic activity of the corpus striatum. OBJECTIVE: To validate the effects of STN DBS on dopamine metabolism and glucose metabolism in the corpus striatum of hemiparkinsonian monkeys using single photon emission computed tomography (SPECT) and position emission tomography (PET). DESIGN, TIME AND SET'rING: A controlled animal study was performed at the Neurosurgery Laboratory, Changhai Hospital of the Second Military Medical University of Chinese PLA between January 2004 and December 2007. METHODS: Hemiparkinsonism was induced in adult Rhesus Macaque monkeys, which exhibit similar characteristics of PD in humans, through unilateral internal carotid artery infusion of 1-methy-4-phenyl-1, 2, 3, 6-tetrahydropyrindine. Following model establishment, stimulation electrodes were implanted in the right STN, and chronic high-frequency stimulation (60 μs pulse width, 130 Hz frequency, and 1.5-2.0 V pressure) was performed. MAIN OUTCOME MEASURES: The changes in dopamine transporter (DAT), D2 receptor (D2R), and glucose metabolism in the corpus striatum following STN DBS were observed using SPECT and PET. RESULTS: SPECT examination showed that DAT specific binding in the right corpus striatum was increased at 3 months after DBS compared with prior to stimulation, and D2R specific binding in the right corpus striatum gradually decreased near levels on the left (non-electrode-implanted) side within 3 months after DBS. PET examination showed that the glucose metabolism in the right corpus striatum was markedly increased at 3 months after effective DBS. Hemiparkinsonism monkeys showed improved left limb rigidity, increased activities, and stable gait under chronic high-frequency stimulation. CONCLUSION: STN DBS increased striatal DAT, decreased D2R, and enhanced glucose metabolism, suggesting that chronic, high-frequency STN stimulation enhanced the metabolic activity of the corpus striatum, a mechanism for improving the PD symptoms of hemiparkinsonian monkeys.
文摘Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.
文摘BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment.
文摘To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspected CAD were enrolled in the prospective study. All patients underwent myocardial perfusion scintigraphy in SPECT with dual isotopes of T1-201 and dipyridamole stress Tc-99m sestamibi. Rest and stress imaging protocol were performed in 2 hours by dose of 3 mCi TI-201 and 25 mCi Tc-99m sestamibi. The acquisition parameters includes LEHR collimator, energy peak of 72 and 167 keV for T1-201 and 140 keV for Tc-99m, 180-degree rotation from RAO to LPO, matrix size 64x64, and 25second/frame/64 frames. The 20-segment model of left ventricle was used in automatic quantitation software. Coronary angiography was used as gold standard. CAD was defined as 50% of lumen stenosis on coronary angiography. Rest TI-201/stress tc-99m sestamibi dual-isotope SPECT demonstrated a sensitivity of 94.59% and specificity of 70%, positive predictive value of 79.54% and negative predictive value of 91.3% in detection of coronary artery disease. Sensitivity and specificity for detecting multi-vessel coronary artery disease were 82.75% and 81.57% for the left anterior descending, 77.77% and 91.83% for left circumflex and 94.11% and 82% for right coronary artery. 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT has high sensitivity, specificity, positive predictive value and negative predictive value in detecting chronic coronary artery disease with greater than 50% stenosis assessed by coronary angiography Moreover, this imaging protocol gives high imaging quality, time-saving and convenience.
基金Supported by Zhejiang Province Public Welfare Technology Application Research Project,No.LGF21H180007.
文摘BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-old woman with a 4-wk history of daily fevers was admitted to our hospital.A whole body^(18)-Fluordesoxyglucose(PET-FDG)positron emission tomography/computed tomography(PET/CT)was performed to elucidate the source of the fever.However,whole body^(18)-FDG PET/CT raised the suspicion of a malignant lesion because of peripheral FDG accumulation(SUVmax 3.5 g/mL)higher than that of the normal liver parenchyma(SUVmax 1.6 g/mL)surrounding a hypoactive area,and no other abnormalities were showed.Subsequently,the patient underwent liver mass resection.Histopathology showed a hepatic cavernous hemangioma with fatty infiltration around the lesion.The fever disappeared four days after surgery and the patient did not present any complications during follow-up.CONCLUSION Fatty infiltration in the peripheral parts of hepatic cavernous hemangioma may lead to subacute inflammation which further activate the Kupffer cells.This may cause prolonged fever and peripheral rim FDG accumulation on PET/CT.
基金supported by the Tehran University of Medical Sciences under Grant No.36291PET/CT and Cyclotron Center of Masih Daneshvari Hospital at Shahid Beheshti University of Medical Sciences。
文摘Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.
文摘BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated with infection,based on increased glucose utilization by activated macrophages and granulocytes.Aseptic vascular grafts,like all foreign bodies,can stimulate an inflammatory response,which can present as increased activity on 18F-FDG PET/CT.Consequently,distinguishing aseptic inflammation from graft infection,though important,can be difficult.In the case of endovascular aneurysm repair(EVAR),a minimally invasive procedure involving the transfemoral insertion of an endoprosthetic stent graft,the normal postoperative appearance of these grafts on 18F-FDG PET/CT can vary over time,potentially confounding study interpretation.AIM To investigate the visual,semiquantitative,and temporal characteristics of aseptic vascular grafts in patients status post EVAR.METHODS In this observational retrospective cohort study,patients with history of EVAR who underwent 18F-FDG PET/CT for indications other than infection were identified retrospectively.All patients were asymptomatic for graft infection-no abdominal pain,fever of unknown origin,sepsis,or leukocytosis-at the time of imaging and for≥2 mo after each PET/CT.Imaging studies such as CT for each patient were also reviewed,and any patients with suspected or confirmed vascular graft infection were excluded.One hundred two scans performed on 43 patients(34 males;9 females;age=77±8 years at the time of the final PET/CT)were retrospectively reviewed.All 43 patients had an abdominal aortic(AA)vascular graft,40 patients had a right iliac(RI)limb graft,and 41 patients had a left iliac(LI)limb graft.Twentytwo patients had 1 PET/CT and 21 patients had from 2 to 9 PET/CTs.Grafts were imaged between 2 mo to 168 mo(about 14 years)post placement.Eight grafts were imaged within 6 mo of placement,including three that were imaged within three months of placement.The mean interval between graft placement and PET/CT for all 102 scans was 51±39 mo.PET/CT data was reconstructed with region-of-interest analysis of proximal,mid and distal portions of the grafts and background ascending aorta.Maximum standardized uptake value(SUVmax)was recorded for each region.SUVmax-to-background uptake ratios(URs)were calculated.Visual assessment was performed using a 2-pattern grading scale:Diffuse(homogeneous uptake less than liver uptake)and focal(one or more areas of focal uptake in any part of the graft).Statistical analysis was performed.RESULTS In total,there were 306 AA grafts,285 LI grafts,282 RI grafts,and 306 ascending aorta background SUVmax measurements.For all 102 scans,mean SUVmax values for AA grafts were 2.8-3.0 along proximal,mid,and distal segments.Mean SUVmax values for LI grafts and RI grafts were 2.7-2.8.Mean SUVmax values for background were 2.5±0.5.Mean URs were 1.1-1.2.Visual analysis of the scans reflected results of quantitative analysis.On visual inspection,98%revealed diffuse,homogeneous 18F-FDG uptake less than liver.Graft URs and visual pattern categories were significantly associated for AA graft URs(F-ratio=21.5,P<0.001),LI graft URs(F-ratio=20.4,P<0.001),and RI graft URs(F-ratio=30.4,P<0.001).Thus,visual patterns of 18F-FDG uptake corresponded statistically significantly to semiquantitative URs.The age of grafts showing focal patterns was greater than grafts showing diffuse patterns,87±89 vs 50±37 mo,respectively(P=0.02).URs were significantly associated with graft age for AA grafts(r=0.19,P=0.001).URs were also significantly associated with graft age for LI grafts(r=0.25,P<0.0001),and RI grafts(r=0.31,P<0.001).Quartiles of similar numbers of graft(n=25-27)grouped by graft age indicated that URs were significantly higher for 4th quartile vs 2nd quartile URs(F-ratio=19.5,P<0.001).When evaluating URs,graft SUVmax values within 10%-20%of the ascending aorta SUVmax is evident in aseptic grafts,except for grafts in the oldest quartiles.In this study,grafts in the oldest quartiles(>7 years post EVAR)showed SUVmax up to 30%higher than the ascending aorta SUVmax.CONCLUSION Characteristics of an aseptic vascular stent graft in the aorta and iliac vessels on 18F-FDG PET/CT include graft SUVmax values within 10%-20%of the ascending aorta background SUVmax.The SUVmax of older aseptic grafts can be as much as 30%above background.The visual uptake pattern of diffuse,homogeneous uptake less than liver was seen in 98%of aseptic vascular grafts,making this pattern particularly reassuring for clinicians.
基金This work was supported by grants from the National Key Laboratory of Infectious Disease Prevention and Control Independent Research Open Project(No.2018SKLID307)Science and Technology Fund Project of Guizhou Health and Health Commission(No.gzwjkj2019-1-065)+1 种基金Science and Technology Plan Project of Guiyang(No.[2017]30-30)the Department of Science and Technology of Guizhou Province(No.[2017]5718).
文摘Parkinson disease(PD)is the second-most common neurodegenerative disorder.Its main pathological mechanism is the selective degeneration and deletion of dopaminergic neurons in the dense part of the substantia nigra and the damage of dopaminergic neurons caused by the abnormal deposition of a Lewy body,leading to a decreased dopamine level.Positron emission computed tomography(PET)/single photon emission computed tomography(SPECT)is a molecular imaging technology that can directly or indirectly reflect changes in molecular levels by using a specific tracer.With the research and development on the tracers of related enzymes for labeling dopamine transporter and dopamine receptor and for being involved in dopamine formation,this imaging technology has been applied to all aspects of PD research.It not only contributes to clinical work but also provides an important theoretical basis for exploring the pathological mechanism of PD at a molecular level.Therefore,this review discusses the application value of PET/SPECT in PD in terms of early diagnosis,disease severity evaluation,clinical manifestations,differential diagnosis,and pathological mechanism.
基金Supported by the Science and Technology Research Project of State Administration of Traditional Chinese Medicine(No.00-01LP11)Shenzhen Science and Technology Project(Health and Medicine Class,No.201102015)
文摘Objective:To explore the effectiveness of electro-acupuncture(EA)in the treatment of childhood autism(CA)and evaluate its effectiveness using single photon emission computed tomography(SPECT).Methods:A total of 55 CA patients(4.52±2.73 years)were enrolled in this study.All patients received EA treatments and were examined by SPECT before and after treatments.Results:Following treatment,the intracerebral multiple focal radioactivity distribution defect areas of CA patients were observed to be partially filled.Specifically,significant differences in the ratios of regional cerebral blood flow and global cerebral blood flow before(Fb)and after(Fe)EA treatment in different lesions were observed(in the left prefrontal cortex,t=5.01,P〈0.01;in the right prefrontal cortex,t=2.32,P〈0.05;in the left temporal lobe,t=4.54,P〈0.01;in the right temporal lobe,t=2.90,P〈0.05;in the left Broca’s area,t=5.82,P〈0.01).After EA treatment,the patients exhibited symptomatic relief.Conclusion:EA is useful to treat CA and SPECT can be used to evaluate the effectiveness of this treatment.
文摘Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) can depict many of the lesions depicted with a PET scanner in the lungs, which is used in place of PET-CT for discriminating malignant from benign pulmonary nodules in many studies. However, DHC-SPECT has inevitable false-negative results because the sensitivity for small lesions less than 2.0 cm is limited, and has high false-positive rate for active inflammatory nodules. Furthermore,DHC-SPECT also has a considerably higher cost ($300 in China) than other imaging examination.