期刊文献+
共找到2,787篇文章
< 1 2 140 >
每页显示 20 50 100
Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion 被引量:2
1
作者 Kiyoshi Oka Takeshi Seki +3 位作者 Tomohiro Akatsu Takao Wakabayashi Kazuo Inui Junji Yoshino 《World Journal of Gastroenterology》 SCIE CAS 2014年第14期4050-4058,共9页
AIM:To verify the performance of a lesion size measurement system through a clinical study.METHODS:Our proposed system,which consists of a conventional endoscope,an optical device,an optical probe,and a personal compu... AIM:To verify the performance of a lesion size measurement system through a clinical study.METHODS:Our proposed system,which consists of a conventional endoscope,an optical device,an optical probe,and a personal computer,generates a grid scale to measure the lesion size from an endoscopic image.The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance.The shape of the grid scale was corrected to match the distortion of the endoscopic image.The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope.The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image.(1)A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope;and(2)The sizes of three colon polyps were measured using our system during endoscopy.These sizes were immediately measured by scale after their removal.RESULTS:There was no error atα=0°.In addition,the values of eM(mean±SD)were 0.24±0.11 mm(α=10°),0.90±0.58 mm(α=20°)and 2.31±1.41mm(α=30°).According to these results,our system has been confirmed to measure accurately when the tilt angle is less than 20°.The measurement error was approximately 1 mm in the clinical study.Therefore,it was concluded that our proposed measurement system was also effective in clinical examinations.CONCLUSION:By combining simple optical equipment with a conventional endoscope,a quick and accurate system for measuring lesion size was established. 展开更多
关键词 LESION size NON-CONTACT measurement ENDOSCOPE Grid
下载PDF
Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases:A systematic review and meta-analysis 被引量:2
2
作者 Eyad Gadour Abeer Awad +3 位作者 Zeinab Hassan Khalid Jebril Shrwani Bogdan Miutescu Hussein Hassan Okasha 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期742-758,共17页
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor... BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases. 展开更多
关键词 Focal liver lesion Liver abscess drainage Fine needle aspiration Gastric varices endoscopic ultrasound
下载PDF
Endoscopic submucosal dissection vs transanal endoscopic surgery for rectal tumors: A systematic review and meta-analysis
3
作者 Long-Wu Huang Ying Zhong 《World Journal of Clinical Cases》 SCIE 2024年第1期95-106,共12页
BACKGROUND Endoscopic submucosal dissection(ESD)and transanal endoscopic submucosal dissection(TES)are widely employed surgical techniques.However,the comparative efficacy and safety of both remain inconclusive.AIM To... BACKGROUND Endoscopic submucosal dissection(ESD)and transanal endoscopic submucosal dissection(TES)are widely employed surgical techniques.However,the comparative efficacy and safety of both remain inconclusive.AIM To comprehensively analyze and discern differences in surgical outcomes between ESD and TES.METHODS We conducted a systematic search of the electronic databases PubMed,Embase,Cochrane Central Register of Controlled Trials,Scopus,and CINAHL from inception till August 2023.We analyzed outcomes including recurrence rate,en bloc resection,R0 resection rate,perforation rate,procedure length,and hospital stay length applying a random-effects inverse-variance model.We assessed publication bias by conducting an Egger’s regression test and sensitivity analyses.RESULTS We pooled data from 11 studies involving 1013 participants.We found similar recurrence rates,with a pooled odds ratio of 0.545(95%CI:0.176-1.687).En bloc resection,R0 resection,and perforation rate values were also similar for both ESD and TES.The pooled analysis for procedure length indicated a mean difference of-4.19 min(95%CI:-22.73 to 14.35),and the hospital stay was on average shorter for ESDs by about 0.789 days(95%CI:-1.671 to 0.093).CONCLUSION Both ESD and TES displayed similar efficacy and safety profiles across multiple outcomes.Our findings show that individualized patient and surgeon preferences,alongside specific clinical contexts,can be considered when selecting between these two techniques. 展开更多
关键词 endoscopic submucosal dissection Transanal endoscopic submucosal dissection META-ANALYSIS Surgical outcomes Rectal tumours
下载PDF
Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages:A systematic review focusing on issues and rescue management 被引量:1
4
作者 Elia Armellini Flavio Metelli +4 位作者 Andrea Anderloni Anna Cominardi Giovanni Aragona Michele Marini FabioPace 《World Journal of Gastroenterology》 SCIE CAS 2023年第21期3341-3361,共21页
BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffus... BACKGROUND The introduction of lumen-apposing metal stents(LAMS)for endoscopic ultrasound(EUS)-guided drainages has marked a turning point in the field of interventional ultrasound and it is gathering worldwide diffusion in different clinical settings.Nevertheless,the procedure may conceal unexpected pitfalls.LAMS misdeployment is the most frequent cause of technical failure and it can be considered a procedure-related adverse event when it hampers the conclusion of the planned procedure or results in significant clinical consequences.Stent misdeployment can be managed successfully by endoscopic rescue maneuvers to allow the completion of the procedure.To date,no standardized indication is available to guide an appropriate rescue strategy depending on the type of procedure or of misdeployment.AIM To evaluate the incidence of LAMS misdeployment during EUS-guided choledochoduodenostomy(EUS-CDS),gallbladder drainage(EUS-GBD)and pancreatic fluid collections drainage(EUS-PFC)and to describe the endoscopic rescue strategies adopted under the circumstance.METHODS We conducted a systematic review of the literature on PubMed by searching for studies published up to October 2022.The search was carried out using the exploded medical subject heading terms“lumen apposing metal stent”,“LAMS”,“endoscopic ultrasound”and“choledochoduodenostomy”or“gallbladder”or“pancreatic fluid collections”.We included in the review on-label EUS-guided procedures namely EUS-CDS,EUS-GBD and EUS-PFC.Only those publications reporting EUS-guided LAMS positioning were considered.The studies reporting a technical success rate of 100%and other procedure-related adverse events were considered to calculate the overall rate of LAMS misdeployment,while studies not reporting the causes of technical failure were excluded.Case reports were considered only for the extraction of data regarding the issues of misdeployment and rescue techniques.The following data were collected from each study:Author,year of publication,study design,study population,clinical indication,technical success,reported number of misdeployment,stent type and size,flange misdeployed and type of rescue strategy.RESULTS The overall technical success rate of EUS-CDS,EUS-GBD and EUS-PFC was 93.7%,96.1%,and 98.1%respectively.Significant rates of LAMS misdeployment have been reported for EUS-CDS,EUS-GBD and EUS-PFC drainage,respectively 5.8%,3.4%,and 2.0%.Endoscopic rescue treatment was feasible in 86.8%,80%,and 96.8%of cases.Non endoscopic rescue strategies were required only in 10.3%,16%and 3.2%for EUS-CDS,EUS-GBD,and EUS-PFC.The endoscopic rescue techniques described were over-the-wire deployment of a new stent through the created fistula tract in 44.1%,8%and 64.5%and stent-in-stent in 23.5%,60%,and 12.9%,respectively for EUSCDS,EUS-GBD,and EUS-PFC.Further therapeutic option were endoscopic rendezvous in 11.8%of EUS-CDS and repeated procedure of EUS-guided drainage in 16.1%of EUS-PFC.CONCLUSION LAMS misdeployment is a relatively common adverse event in EUS-guided drainages.There is no consensus on the best rescue approach in these cases and the choice is often made by the endoscopist relying upon the clinical scenario,anatomical characteristics,and local expertise.In this review,we investigated the misdeployment of LAMS for each of the on-label indications focusing on the rescue therapies used,with the aim of providing useful data for endoscopists and to improve patient outcomes. 展开更多
关键词 Lams misdeployment endoscopic ultrasound-guided drainage Lams maldeployment Biliary drainage Gallbladder drainage Pancreatic fluid collections Lumen-apposing metal stents
下载PDF
Prediction,prevention and management of gastroesophageal reflux after per-oral endoscopic myotomy:An update 被引量:3
5
作者 Zaheer Nabi Pradev Inavolu Nageshwar Reddy Duvvuru 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1096-1107,共12页
Achalasia cardia,the most prevalent primary esophageal motility disorder,is predominantly characterized by symptoms of dysphagia and regurgitation.The principal therapeutic approaches for achalasia encompass pneumatic... Achalasia cardia,the most prevalent primary esophageal motility disorder,is predominantly characterized by symptoms of dysphagia and regurgitation.The principal therapeutic approaches for achalasia encompass pneumatic dilatation(PD),Heller's myotomy,and the more recent per-oral endoscopic myotomy(POEM).POEM has been substantiated as a safe and efficacious modality for the management of achalasia.Although POEM demonstrates superior efficacy compared to PD and an efficacy parallel to Heller's myotomy,the incidence of gastroesophageal reflux disease(GERD)following POEM is notably higher than with the aforementioned techniques.While symptomatic reflux post-POEM is relatively infrequent,the significant occurrence of erosive esophagitis and heightened esophageal acid exposure necessitates vigilant monitoring to preclude long-term GERD-related complications.Contemporary advancements in the field have enhanced our comprehension of the risk factors,diagnostic methodologies,preventative strategies,and therapeutic management of GERD subsequent to POEM.This review focuses on the limitations inherent in the 24-h pH study for evaluating post-POEM reflux,potential modifications in the POEM technique to mitigate GERD risk,and the strategies for managing reflux following POEM. 展开更多
关键词 Achalasia cardia Per-oral endoscopic myotomy Gastroesophageal reflux ESOPHAGITIS Gastroesophageal reflux disease
下载PDF
Evaluation of the efficacy and safety of endoscopic band ligation in the treatment of bleeding from mild to moderate gastric varices type 1 被引量:2
6
作者 Yue Deng Ya Jiang +4 位作者 Tong Jiang Ling Chen Hai-Jun Mou Bi-Guang Tuo Guo-Qing Shi 《World Journal of Gastroenterology》 SCIE CAS 2024年第5期440-449,共10页
BACKGROUND According to practice guidelines,endoscopic band ligation(EBL)and endoscopic tissue adhesive injection(TAI)are recommended for treating bleeding from esophagogastric varices.However,EBL and TAI are known to... BACKGROUND According to practice guidelines,endoscopic band ligation(EBL)and endoscopic tissue adhesive injection(TAI)are recommended for treating bleeding from esophagogastric varices.However,EBL and TAI are known to cause serious complications,such as hemorrhage from dislodged ligature rings caused by EBL and hemorrhage from operation-related ulcers resulting from TAI.However,the optimal therapy for mild to moderate type 1 gastric variceal hemorrhage(GOV1)has not been determined.Therefore,the aim of this study was to discover an individualized treatment for mild to moderate GOV1.AIM To compare the efficacy,safety and costs of EBL and TAI for the treatment of mild and moderate GOV1.METHODS A clinical analysis of the data retrieved from patients with mild or moderate GOV1 gastric varices who were treated under endoscopy was also conducted.Patients were allocated to an EBL group or an endoscopic TAI group.The differences in the incidence of varicose relief,operative time,operation success rate,mortality rate within 6 wk,rebleeding rate,6-wk operation-related ulcer healing rate,complication rate and average operation cost were compared between the two groups of patients.RESULTS The total effective rate of the two treatments was similar,but the efficacy of EBL(66.7%)was markedly better than that of TAI(39.2%)(P<0.05).The operation success rate in both groups was 100%,and the 6-wk mortality rate in both groups was 0%.The average operative time(26 min)in the EBL group was significantly shorter than that in the TAI group(46 min)(P<0.01).The rate of delayed postoperative rebleeding in the EBL group was significantly lower than that in the TAI group(11.8%vs 45.1%)(P<0.01).At 6 wk after the operation,the healing rate of operation-related ulcers in the EBL group was 80.4%,which was significantly greater than that in the TAI group(35.3%)(P<0.01).The incidence of postoperative complications in the two groups was similar.The average cost and other related economic factors were greater for the EBL than for the TAI(P<0.01).CONCLUSION For mild to moderate GOV1,patients with EBL had a greater one-time varix eradication rate,a greater 6-wk operation-related ulcer healing rate,a lower delayed rebleeding rate and a lower cost than patients with TAI. 展开更多
关键词 Gastric varices Type 1 gastric variceal hemorrhage endoscopic band ligation Tissue adhesive injection
下载PDF
Endoscopic features and treatments of gastric cystica profunda 被引量:1
7
作者 Zi-Han Geng Yan Zhu +5 位作者 Pei-Yao Fu Yi-Fan Qu Wei-Feng Chen Xia Yang Ping-Hong Zhou Quan-Lin Li 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期673-684,共12页
BACKGROUND Gastric cystica profunda(GCP)represents a rare condition characterized by cystic dilation of gastric glands within the mucosal and/or submucosal layers.GCP is often linked to,or may progress into,early gast... BACKGROUND Gastric cystica profunda(GCP)represents a rare condition characterized by cystic dilation of gastric glands within the mucosal and/or submucosal layers.GCP is often linked to,or may progress into,early gastric cancer(EGC).AIM To provide a comprehensive evaluation of the endoscopic features of GCP while assessing the efficacy of endoscopic treatment,thereby offering guidance for diagnosis and treatment.METHODS This retrospective study involved 104 patients with GCP who underwent endoscopic resection.Alongside demographic and clinical data,regular patient followups were conducted to assess local recurrence.RESULTS Among the 104 patients diagnosed with GCP who underwent endoscopic resection,12.5%had a history of previous gastric procedures.The primary site predominantly affected was the cardia(38.5%,n=40).GCP commonly exhibited intraluminal growth(99%),regular presentation(74.0%),and ulcerative mucosa(61.5%).The leading endoscopic feature was the mucosal lesion type(59.6%,n=62).The average maximum diameter was 20.9±15.3 mm,with mucosal involvement in 60.6%(n=63).Procedures lasted 73.9±57.5 min,achieving complete resection in 91.3%(n=95).Recurrence(4.8%)was managed via either surgical intervention(n=1)or through endoscopic resection(n=4).Final pathology confirmed that 59.6%of GCP cases were associated with EGC.Univariate analysis indicated that elderly males were more susceptible to GCP associated with EGC.Conversely,multivariate analysis identified lesion morphology and endoscopic features as significant risk factors.Survival analysis demonstrated no statistically significant difference in recurrence between GCP with and without EGC(P=0.72).CONCLUSION The findings suggested that endoscopic resection might serve as an effective and minimally invasive treatment for GCP with or without EGC. 展开更多
关键词 Gastric cystica profunda Early gastric cancer endoscopic features endoscopic resection ENDOSCOPY
下载PDF
Endoscopic intramural cystogastrostomy for treatment of peripancreatic fluid collection: A viewpoint from a surgeon 被引量:1
8
作者 Chen-Guo Ker 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期610-613,共4页
Percutaneous or endoscopic drainage is the initial choice for the treatment of peripancreatic fluid collection in symptomatic patients.Endoscopic transgastric fenestration(ETGF)was first reported for the management of... Percutaneous or endoscopic drainage is the initial choice for the treatment of peripancreatic fluid collection in symptomatic patients.Endoscopic transgastric fenestration(ETGF)was first reported for the management of pancreatic pseu-docysts of 20 patients in 2008.From a surgeon’s viewpoint,ETGF is a similar procedure to cystogastrostomy in that they both produce a wide outlet orifice for the drainage of fluid and necrotic debris.ETGF can be performed at least 4 wk after the initial onset of acute pancreatitis and it has a high priority over the surgical approach.However,the surgical approach usually has a better success rate because surgical cystogastrostomy has a wider outlet(>6 cm vs 2 cm)than ETGF.However,percutaneous or endoscopic drainage,ETGF,and surgical approach offer various treatment options for peripancreatic fluid collection patients based on their conditions. 展开更多
关键词 Pancreatitis Pancreatic pseudocyst endoscopic cystogastrostomy Surgical cystogastrostomy Peripancreatic fluid collection Fenestration for pancreatic cyst
下载PDF
Endoscopic ultrasonography-related diagnostic accuracy and clinical significance on small rectal neuroendocrine neoplasms 被引量:1
9
作者 Jun Weng Yu-Fan Chen +5 位作者 Shu-Han Li Yan-Hua Lv Ruo-Bing Chen Guo-Liang Xu Shi-Yong Lin Kun-Hao Bai 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期774-778,共5页
This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal sube... This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal subepithelial lesions(SELs)with a diameter of<20 mm were included in the analysis.The diagnosis and depth assessment of EUS was compared to the histology findings.The prevalence of NENs in rectal SELs was 78.7%(85/108).The sensitivity of EUS in detecting rectal NENs was 98.9%(84/85),while the specificity was 52.2%(12/23).Overall,the diagnostic accuracy of EUS in identifying rectal NENs was 88.9%(96/108).The overall accuracy rate for EUS in assessing the depth of invasion in rectal NENs was 92.9%(78/84).Therefore,EUS demonstrates reasonable diagnostic accuracy in detecting small rectal NENs,with good sensitivity but inferior specificity.EUS may also assist physicians in assessing the depth of invasion in small rectal NENs before endoscopic excision. 展开更多
关键词 Rectal neuroendocrine neoplasms endoscopic ultrasonography DIAGNOSIS Depth of invasion
下载PDF
Endoscopic biliary treatment of unresectable cholangiocarcinoma: A meta-analysis of survival outcomes and systematic review
10
作者 Jeffrey Rebhun Claire M Shin +1 位作者 Uzma D Siddiqui Edward Villa 《World Journal of Gastrointestinal Endoscopy》 2023年第3期177-190,共14页
BACKGROUND Endoscopic radiofrequency ablation(ERFA),percutaneous radiofrequency ablation(PRFA),and photodynamic therapy(PDT),when used in conjunction with conventional biliary stenting,have demonstrated a survival ben... BACKGROUND Endoscopic radiofrequency ablation(ERFA),percutaneous radiofrequency ablation(PRFA),and photodynamic therapy(PDT),when used in conjunction with conventional biliary stenting,have demonstrated a survival benefit in patients with unresectable cholangiocarcinoma.AIM To compare pooled survival outcomes,adverse event rates,and mean stent patency for those undergoing these procedures.METHODS A comprehensive literature review of published studies and abstracts from January 2011 to December 2020 was performed comparing survival outcomes in patients undergoing ERFA with stenting,biliary stenting alone,PRFA with stenting,and PDT with stenting for unresectable cholangiocarcinoma(CCA).RESULTS Data from four studies demonstrated a pooled mean survival favoring ERFA as compared to biliary stenting alone(12.0±0.9 mo vs 6.8±0.3 mo,P<0.001)as well as statistically improved median survival time(13 mo vs 8 mo,P<0.001).Both ERFA with stenting and PRFA with stenting groups demonstrated statistical superiority to biliary stenting alone(P<0.001 and P=0.004,respectively).However,when comparing ERFA to PRFA,pooled data demonstrated overall higher mean survival in the ERFA with stenting cohort as compared to PRFA with stent cohort(12.0+0.9 mo vs 8.1+2.1 mo,P<0.0001).Data from two studies demonstrated a pooled median survival favoring ERFA with stenting as compared to PDT with stenting(11.3 mo vs 8.5 mo,P=0.02).CONCLUSION While further prospective,randomized studies are needed to assess efficacy of ERFA,our metaanalysis demonstrated that this technique offers endoscopists a reasonable palliative method by which to treat patients with unresectable CCA that results in longer survival as compared to biliary stenting alone,percutaneous radiofrequency ablation with biliary stenting,and PDT with biliary stenting as well as an acceptable adverse event profile based on available published data. 展开更多
关键词 endoscopic radiofrequency ablation Percutaneous radiofrequency ablation Photodynamic therapy CHOLANGIOCARCINOMA META-ANALYSIS systematic review
下载PDF
Endoscopic vs radiologic gastrostomy for enteral feeding:A systematic review and meta-analysis
11
作者 Evellin Souza Valentim dos Santos Guilherme Henrique Peixoto de Oliveira +4 位作者 Diogo Turiani Hourneaux de Moura Bruno Salomão Hirsch Roberto Paolo Trasolini Wanderley Marques Bernardo Eduardo GuimarãesHourneaux de Moura 《World Journal of Meta-Analysis》 2023年第6期277-289,共13页
BACKGROUND Percutaneous endoscopic gastrostomy(PEG)and percutaneous radiological gastrostomy(PRG)are minimally invasive techniques commonly used for prolonged enteral nutrition.Despite safe,both techniques may lead to... BACKGROUND Percutaneous endoscopic gastrostomy(PEG)and percutaneous radiological gastrostomy(PRG)are minimally invasive techniques commonly used for prolonged enteral nutrition.Despite safe,both techniques may lead to complications,such as bleeding,infection,pain,peritonitis,and tube-related complications.The literature is unclear on which technique is the safest.AIM To establish which approach has the lowest complication rate.METHODS A database search was performed from inception through November 2022,and comparative studies of PEG and PRG were selected following the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines.All included studies compared the two techniques directly and provided absolute values of the number of complications.Studies with pediatric populations were excluded.The primary outcome of this study was infection and bleeding.Pneumonia,peritonitis,pain,and mechanical complications were secondary outcomes.The risk of bias was assessed using the Cochrane risk-of-bias tool for randomized trials(RoB2)and we used The Risk of Bias in Nonrandomized Studies(ROBINS-I)to analyze the retrospective studies.We also performed GRADE analysis to assess the quality of evidence.Data on risk differences and 95%confidence intervals were obtained using the Mantel-Haenszel test.RESULTS Seventeen studies were included,including two randomized controlled trials and fifteen retrospective cohort studies.The total population was 465218 individuals,with 273493 having undergone PEG and 191725 PRG.The only outcome that showed a significant difference was tube related complications in retrospective studies favoring PEG(95%CI:0.03 to 0.08;P<0.00001),although this outcome did not show significant difference in randomized studies(95%CI:-0.07 to 0.04;P=0.13).There was no difference in the analyses of the following outcomes:infection in retrospective(95%CI:-0.01 to 0.00;P<0.00001)or randomized(95%CI:-0.06 to 0.04;P=0.44)studies;bleeding in retrospective(95%CI:-0.00 to 0.00;P<0.00001)or randomized(95%CI:-0.06 to 0.02;P=0.43)studies;pneumonia in retrospective(95%CI:-0.04 to 0.00;P=0.28)or randomized(95%CI:-0.09 to 0.11;P=0.39)studies;pain in retrospective(95%CI:-0.05 to 0.02;P<0.00001)studies;peritonitis in retrospective(95%CI:-0.02 to 0.01;P<0.0001)studies.CONCLUSION PEG has lower levels of tube-related complications(such as dislocation,leak,obstruction,or breakdown)when compared to PRG. 展开更多
关键词 GASTROSTOMY Adverse events META-ANALYSIS Percutaneous endoscopic Radiological gastrostomy
下载PDF
Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy
12
作者 Mitsuki Tomita Takeshi Ogura +5 位作者 Akitoshi Hakoda Saori Ueno Atsushi Okuda Nobu Nishioka Yoshitaro Yamamoto Hiroki Nishikawa 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第2期181-185,共5页
Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal... Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands. 展开更多
关键词 endoscopic ultrasound-guided hepaticogastrostomy endoscopic ultrasound-guided biliary drainage endoscopic retrograde CHOLANGIOPANCREATOGRAPHY
下载PDF
Endoscopic band ligation or endoscopic tissue adhesive injection in the treatment of gastric varices:Which is better?
13
作者 Li-Zhi Yi Sheng-Bing Zhao 《World Journal of Gastroenterology》 SCIE CAS 2024年第21期2827-2828,共2页
The combination of endoscopic ultrasound with endoscopic treatment of type 1 gastric variceal hemorrhage may improve the robustness and generalizability of the findings in future studies.Moreover,the esophageal varice... The combination of endoscopic ultrasound with endoscopic treatment of type 1 gastric variceal hemorrhage may improve the robustness and generalizability of the findings in future studies.Moreover,the esophageal varices should also be included in the evaluation of treatment efficacy in subsequent studies to reach a more convincing conclusion. 展开更多
关键词 Gastric varices Esophageal varices endoscopic band ligation endoscopic tissue adhesive injection endoscopic ultrasound
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage
14
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Gastroesophageal reflux after per-oral endoscopic myotomy:Management literature
15
作者 Ahmed Tawheed Ibrahim Halil Bahcecioglu +1 位作者 Mehmet Yalniz Mohamed El-Kassas 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期2947-2953,共7页
In this editorial,we respond to a review article by Nabi et al,in which the authors discussed gastroesophageal reflux(GER)following peroral endoscopic myotomy(POEM).POEM is presently the primary therapeutic option for... In this editorial,we respond to a review article by Nabi et al,in which the authors discussed gastroesophageal reflux(GER)following peroral endoscopic myotomy(POEM).POEM is presently the primary therapeutic option for achalasia,which is both safe and effective.A few adverse effects were documented after POEM,including GER.The diagnostic criteria were not clear enough because approximately 60%of patients have a long acid exposure time,while only 10%experience reflux symptoms.Multiple predictors of high disease incidence have been identified,including old age,female sex,obesity,and a baseline lower esophageal sphincter pressure of less than 45 mmHg.Some technical steps during the procedure,such as a lengthy or full-thickness myotomy,may further enhance the risk.Proton pump inhibitors are currently the first line of treatment.Emerging voices are increasingly advocating for the routine combining of POEM with an endoscopic fundoplication method,such as peroral endoscopic fundoplication or transoral incisionless fundoplication.However,more research is necessary to determine the safety and effectiveness of these procedures in the long term for patients who have undergone them. 展开更多
关键词 Achalasia Per-oral endoscopic myotomy Gastroesophageal reflux disease Transoral incisionless fundoplication Peroral endoscopic fundoplication
下载PDF
Endoscopic treatment of biliopancreatic pathology in patients with Whipple's pancreaticoduodenectomy surgical variants: Lessons learned from single-balloon enteroscopy-assisted ERCP
16
作者 Rodrigo Garcés-Durán Laurent Monino +2 位作者 Pierre H Deprez Hubert Piessevaux Tom G Moreels 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第5期509-514,共6页
Background: Endoscopic treatment of biliopancreatic pathology is challenging due to surgically altered anatomy after Whipple's pancreaticoduodenectomy. This study aimed to evaluate the feasibility and safety of si... Background: Endoscopic treatment of biliopancreatic pathology is challenging due to surgically altered anatomy after Whipple's pancreaticoduodenectomy. This study aimed to evaluate the feasibility and safety of single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography(SBE-ERCP) to treat biliopancreatic pathology in patients with Whipple's pancreaticoduodenectomy surgical variants. Methods: We retrospectively analyzed 106 SBE-ERCP procedures in 46 patients with Whipple's variants. Technical and clinical success rates and adverse events were evaluated. Results: Biliary SBE-ERCP was performed in 34 patients and pancreatic SBE-ERCP in 17, including 5 with both indications. From a total of 106 SBE-ERCP procedures, 76 were biliary indication with technical success rate of 68/76(90%) procedures and clinical success rate of 30/34(88%) patients. Mild adverse event rate was 8/76(11%), without serious adverse events. From a total of 106 SBE-ERCP procedures, 30 were pancreatic indication with technical success rate of 24/30(80%) procedures( P = 0.194 vs. biliary SBEERCP) and clinical success rate of 11/17(65%) patients( P = 0.016 vs. biliary SBE-ERCP). Mild adverse event rate was 6/30(20%)( P = 0.194 vs. biliary SBE-ERCP), without serious adverse events. After SBE-ERCP failure, endoscopic ultrasound-guided drainage, percutaneous drainage and redo surgery were alternative therapeutic options. Conclusions: Biliopancreatic pathology after Whipple's pancreaticoduodenectomy variants can be treated using SBE-ERCP without serious adverse events. Technical and clinical success rates are high for biliary indications, whereas clinical success rate of pancreatic indications is significantly lower. SBE-ERCP can be considered as first-line treatment option in this patient group with surgically altered anatomy. 展开更多
关键词 ENTEROSCOPY endoscopic retrograde CHOLANGIOPANCREATOGRAPHY PANCREATICODUODENECTOMY Surgically altered anatomy Whipple’s procedure
下载PDF
Exploring non-curative endoscopic submucosal dissection:Current treatment optimization and future indication expansion
17
作者 Yi-Nong Zhu Xiang-Lei Yuan +4 位作者 Wei Liu Yu-Hang Zhang Yi Mou Bing Hu Lian-Song Ye 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1257-1260,共4页
The increasing popularity of endoscopic submucosal dissection(ESD)as a treatment for early gastric cancer has highlighted the importance of quality assessment in achieving curative resections.This article emphasizes t... The increasing popularity of endoscopic submucosal dissection(ESD)as a treatment for early gastric cancer has highlighted the importance of quality assessment in achieving curative resections.This article emphasizes the significance of evaluating ESD quality,not only for curative cases but also for non-curative ones.Postoperative assessment relies on the endoscopic curability(eCura)classification,but management strategies for eCuraC-1 tumour with a positive horizontal margin are unclear.Current research primarily focuses on comparing additional surgical procedures in high-risk patients,while studies specifically targeting eCuraC-1 patients are limited.Exploring management strategies and follow-up outcomes for such cases could provide valuable insights.Furthermore,the application of molecular imaging using near-infrared fluorescent tracers holds promise for precise tumour diagnosis and navigation,potentially impacting the management of early-stage gastric cancer patients.Advancing research in these areas is essential for improving the overall efficacy of endoscopic techniques and refining treatment indications. 展开更多
关键词 Early gastric cancer endoscopic submucosal dissection Quality control Noncurative endoscopic submucosal dissection Near-infrared fluorescent tracer
下载PDF
The outcomes and safety of patients undergoing endoscopic retrograde cholangiopancreatography combining a single-use cholangioscope and a single-use duodenoscope:A multicenter retrospective international study
18
作者 Alessandro Fugazza Matteo Colombo +20 位作者 Michel Kahaleh V.Raman Muthusamy Bick Benjamin Wim Laleman Carmelo Barbera Carlo Fabbri Jose Nieto Abed Al-Lehibi Mohan Ramchandani Amy Tyberg Haroon Shahid Avik Sarkar Dean Ehrlich Stuart Shermand Cecilia Binda Marco Spadaccini Andrea Iannone Kareem Khalaf Nageshwar Reddy Andrea Anderloni Alessandro Repici 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第1期71-76,共6页
Background: Duodenoscope-related multidrug-resistant organism(MDRO) infections raise concerns. Disposable duodenoscopes have been recently introduced in the market and approved by regulatory agencies with the aim to r... Background: Duodenoscope-related multidrug-resistant organism(MDRO) infections raise concerns. Disposable duodenoscopes have been recently introduced in the market and approved by regulatory agencies with the aim to reduce the risk of endoscopic retrograde cholangiopancreatography(ERCP) associated infections. The aim of this study was to evaluate the outcome of procedures performed with single-use duodenoscopes in patients with clinical indications to single-operator cholangiopancreatoscopy. Methods: This is a multicenter international, retrospective study combining all patients who underwent complex biliopancreatic interventions using the combination of a single-use duodenoscope and a single-use cholangioscope. The primary outcome was technical success defined as ERCP completion for the intended clinical indication. Secondary outcomes were procedural duration, rate of cross-over to reusable duodenoscope, operator-reported satisfaction score(1 to 10) on performance rating of the single-use duodenoscope, and adverse event(AE) rate. Results: A total of 66 patients(26, 39.4% female) were included in the study. ERCP was categorized according to ASGE ERCP grading system as 47(71.2%) grade 3 and 19(28.8%) grade 4. The technical success rate was 98.5%(65/66). Procedural duration was 64(interquartile range 15-189) min, cross-over rate to reusable duodenoscope was 1/66(1.5%). The satisfaction score of the single-use duodenoscope classified by the operators was 8.6 ± 1.3 points. Four patients(6.1%) experienced AEs not directly related to the single-use duodenoscope, namely 2 post-ERCP pancreatitis(PEP), 1 cholangitis and 1 bleeding.Conclusions: Single-use duodenoscope is effective, reliable and safe even in technically challenging procedures with a non-inferiority to reusable duodenoscope, making these devices a viable alternative to standard reusable equipment. 展开更多
关键词 Single-operator cholangioscopy Single-use duodenoscope endoscopic retrograde CHOLANGIOPANCREATOGRAPHY Indeterminate biliary stricture Difficult biliary stones
下载PDF
Efficacy of adjuvant mitomycin-C and triamcinoloneimpregnated nasal packing for endoscopic dacryocystorhinostomy
19
作者 Sang Yoon Kim Christopher B Chambers Jung Hyo Ahn 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期480-484,共5页
●AIM:To compare the success rate and complications of adjuvant use of mitomycin C and triamcinoloneimpregnated biodegradable nasal packing(TABP)in endoscopic dacryocystorhinostomy(DCR).And to evaluate the efficacy of... ●AIM:To compare the success rate and complications of adjuvant use of mitomycin C and triamcinoloneimpregnated biodegradable nasal packing(TABP)in endoscopic dacryocystorhinostomy(DCR).And to evaluate the efficacy of combining intraoperative mitomycin C and TABP for endoscopic DCR.●METHODS:A total of 198 eyes of 148 patients who underwent endoscopic DCR for acquired nasolacrimal duct obstruction were retrospectively analysed.The patients were randomly divided into three groups:Group A included patients treated without intraoperative mitomycin C but with TABP,Group B included patients treated without triamcinolone but with intraoperative mitomycin C and normal saline-impregnated nasal packing,and Group C included patients treated with intraoperative mitomycin C and TABP.●RESULTS:The results revealed no significant difference in the overall success rates between Groups A(86.8%)and B(89.2%;P=0.377).However,Group C(97.5%)showed a significantly higher overall success rate than Groups A and B.The incidence of granulomas was significantly lower in group C(5%)than in Groups A(20.8%)and B(15.2%;P=0.009).Other complications,such as crust,synechiae,and revision surgery,did not differ significantly among the three groups.●CONCLUSION:The combination of intraoperative mitomycin C and TABP effectively prevents granulomas and enhances surgical success rate.Additionally,there is no statistically significant difference observed between the use of mitomycin C or TABP alone. 展开更多
关键词 DACRYOCYSTORHINOSTOMY endoscopic mitomycin C TRIAMCINOLONE biodegradable
下载PDF
CMMCAN:Lightweight Feature Extraction and Matching Network for Endoscopic Images Based on Adaptive Attention
20
作者 Nannan Chong Fan Yang 《Computers, Materials & Continua》 SCIE EI 2024年第8期2761-2783,共23页
In minimally invasive surgery,endoscopes or laparoscopes equipped with miniature cameras and tools are used to enter the human body for therapeutic purposes through small incisions or natural cavities.However,in clini... In minimally invasive surgery,endoscopes or laparoscopes equipped with miniature cameras and tools are used to enter the human body for therapeutic purposes through small incisions or natural cavities.However,in clinical operating environments,endoscopic images often suffer from challenges such as low texture,uneven illumination,and non-rigid structures,which affect feature observation and extraction.This can severely impact surgical navigation or clinical diagnosis due to missing feature points in endoscopic images,leading to treatment and postoperative recovery issues for patients.To address these challenges,this paper introduces,for the first time,a Cross-Channel Multi-Modal Adaptive Spatial Feature Fusion(ASFF)module based on the lightweight architecture of EfficientViT.Additionally,a novel lightweight feature extraction and matching network based on attention mechanism is proposed.This network dynamically adjusts attention weights for cross-modal information from grayscale images and optical flow images through a dual-branch Siamese network.It extracts static and dynamic information features ranging from low-level to high-level,and from local to global,ensuring robust feature extraction across different widths,noise levels,and blur scenarios.Global and local matching are performed through a multi-level cascaded attention mechanism,with cross-channel attention introduced to simultaneously extract low-level and high-level features.Extensive ablation experiments and comparative studies are conducted on the HyperKvasir,EAD,M2caiSeg,CVC-ClinicDB,and UCL synthetic datasets.Experimental results demonstrate that the proposed network improves upon the baseline EfficientViT-B3 model by 75.4%in accuracy(Acc),while also enhancing runtime performance and storage efficiency.When compared with the complex DenseDescriptor feature extraction network,the difference in Acc is less than 7.22%,and IoU calculation results on specific datasets outperform complex dense models.Furthermore,this method increases the F1 score by 33.2%and accelerates runtime by 70.2%.It is noteworthy that the speed of CMMCAN surpasses that of comparative lightweight models,with feature extraction and matching performance comparable to existing complex models but with faster speed and higher cost-effectiveness. 展开更多
关键词 Feature extraction and matching lightweighted network medical images endoscopic ATTENTION
下载PDF
上一页 1 2 140 下一页 到第
使用帮助 返回顶部