Improvement of energy resolution of x-ray transition-edge sensor using K-means algorithm and Wiener filter
1
作者 马卿效 张文 +8 位作者 李佩展 王争 冯志发 杨心开 钟家强 缪巍 任远 李婧 史生才 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期695-699,共5页
We develop an x-ray Ti/Au transition-edge sensor(TES)with an Au absorber deposited on the center of TES and improved its energy resolution using the K-means clustering algorithm in combination with Wiener filter.We fi... We develop an x-ray Ti/Au transition-edge sensor(TES)with an Au absorber deposited on the center of TES and improved its energy resolution using the K-means clustering algorithm in combination with Wiener filter.We firstly extract the main parameters of each recorded pulse trace,which are adopted to classify these traces into several clusters in the K-means clustering algorithm.Then real traces are selected for energy resolution analysis.Following the baseline correction,the Wiener filter is used to improve the signal-to-noise ratio.Although the silicon underneath the TES has not been etched to reduce the thermal conductance,the energy resolution of the developed x-ray TES is improved from 94 eV to 44 eV at 5.9 keV. 展开更多
关键词 transition-edge sensors energy resolution K-means clustering Wiener filter
下载PDF
Characterizations of the electrothermal parameters of a transition edge sensor microcalorimeter and its energy resolution
2
作者 Yue Zhao Hubing Wang +1 位作者 Bo Gao Zhen Wang 《Superconductivity》 2023年第3期1-7,共7页
We developed a transition‐edge sensor microcalorimeter(μ‐calorimeter)using Mo/Au/Au thin films.We report the detector fabrication,the measurements of the electrothermal parameters and the noise characterizations of... We developed a transition‐edge sensor microcalorimeter(μ‐calorimeter)using Mo/Au/Au thin films.We report the detector fabrication,the measurements of the electrothermal parameters and the noise characterizations of the transition‐edge sensor μ‐calorimeters.We estimated the energy resolution of theμ‐calorimeter using the measured noise spectrum and the calculated power‐to‐current responsivity.Using a ^(55)Fe radioactive X‐ray source,we characterized the detector responses to incident photons at various working points.The best instrumental energy resolution achieved was 4.13 eV@5.9 keV,which agrees qualitatively with the resolution of 4.01 eV estimated from the noise spectrum. 展开更多
关键词 Transition edge sensor MICROCALORIMETER energy resolution X‐ray
原文传递
Measurement of the high energyγ-rays from heavy ion reactions usingČerenkov detector
3
作者 Da-Wei Si Yan Zhou +7 位作者 Sheng Xiao Zhi Qin Dong Guo Yu-Hao Qin Yi-Jie Wang Bo-Yuan Zhang Bai-Ting Tian Zhi-Gang Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期123-130,共8页
The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe for short-range correlation in atomic nuclei. The energy of the γ-rays can be measured by collectin... The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe for short-range correlation in atomic nuclei. The energy of the γ-rays can be measured by collecting the Čerenkov light in the medium induced by the fast electrons generated in the Compton scattering or electromagnetic shower of the incident γray. Two types of detectors based on pure water and lead glass as sensitive materials were designed for this purpose. The γresponse and optical photon propagation in the detectors were simulated based on electromagnetic and optical processes in Geant4. The inherent energy resolutions of 0.022(4) + 0.51(2)∕E^(1/2)_(γ) for water and 0.0026(3) + 0.446(3)∕E^(1/2)_(γ) for lead glass were obtained. The geometry sizes of the lead glass and water were optimized to 30 cm × 30 cm × 30 cm and 60 cm × 60 cm ×120 cm, respectively, to detect high-energy γ-rays at 160 MeV. The Hough transform method was applied to reconstruct the direction of the incident γ-rays, providing the ability to experimentally distinguish the high-energy γ-rays produced in the reactions on the target from random background cosmic-ray muons. 展开更多
关键词 Bremsstrahlungγ-rays Čerenkov GEANT4 energy resolution Direction reconstruction Hough transform
下载PDF
Investigation of the energy resolution with a RETGEM detector
4
作者 刘达 鲁辰桂 +13 位作者 段利敏 杨贺润 鲁彦霞 胡荣江 李祖玉 张金霞 胡正国 孙友梅 徐志国 马朋 耿朋 唐述文 王文昕 周建荣 《Chinese Physics C》 SCIE CAS CSCD 2010年第4期479-481,共3页
A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with di... A novel Micro-pattern gaseous detector (MPGD), thick GEM with electrodes made of a resistive material (RETGEM) is presented. In this paper we mainly investigate the energy resolution of a RETGEM in Ar+CO2 with different gas mixtures. The results indicate that an energy resolution 30% in single and double mode can be obtained. The existence of an optimum energy resolution is discussed. 展开更多
关键词 RETCEM detector energy resolution Ar+CO2 single mode double mode
原文传递
Improving the energy resolution of the reactor antineutrino energy reconstruction with positron direction
5
作者 Lianghong Wei Liang Zhan +1 位作者 Jun Cao Wei Wang 《Radiation Detection Technology and Methods》 CSCD 2020年第3期356-361,共6页
Purpose Improving the energy resolution of the reactor antineutrino energy reconstruction.Methods Simulate the energy resolution of a liquid scintillator detector and reconstruct the antineutrino energy with the posit... Purpose Improving the energy resolution of the reactor antineutrino energy reconstruction.Methods Simulate the energy resolution of a liquid scintillator detector and reconstruct the antineutrino energy with the positron scattering angle,a simple positron direction reconstruction method is implemented in a toy liquid scintillator detector like the Taishan Antineutrino Observatory(TAO)with 4500 photoelectron yield per MeV.Results A 4%to 26%improvement of energy resolution can be achieved for 5 MeV reactor antineutrinos at TAO.Conclusion The emission direction of the produced positron in IBD reaction can be used to estimate the kinetic energy of neutron and thus the reconstructed antineutrino energy resolution can be improved. 展开更多
关键词 energy resolution Neutron recoiling Positron direction reconstruction CERENKOV
原文传递
Development of a Gamma Spectroscopy Detector Based on SiPMs and 1" Ce:GAGG Scintillator
6
作者 Qiang Wang Zetao Zhang +6 位作者 Yuchong Ding Xuanhou Hu Xiong Xiao Biao Wang Jingjing Qu Qianyin Wan Yang Xu 《Journal of Applied Mathematics and Physics》 2023年第7期2156-2164,共9页
In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy ... In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy spectrum detectors based on gadolinium gallium aluminum garnet (Ce:GAGG) scintillation crystals are minor. In this work, a 1-inch Ce:GAGG and Silicon Photomultipliers (SiPMs) are employed to construct a detector, and the coupled medium was silicone oil. An optimal SiPMs quantity scheme for the energy resolution was determined by varying the number of SiPMs coupled to Ce:GAGG and studying the effect of the different number of SiPMs on the energy resolution of the detector. Energy-resolution contrast experiments between Ce:GAGG and NaI(Tl) were performed using this scheme. The experimental results demonstrate that increasing the number of SiPMs enhances the energy resolution of the detector significantly. Notably, the energy resolution of the Ce:GAGG detector is comparable to that of the NaI(Tl) detector. Additionally, both detectors exhibit an energy linearity exceeding 99.9%. . 展开更多
关键词 Ce:GAGG Gamma Spectroscopy DETECTOR SiPMs energy resolution
下载PDF
Application of pole-zero cancellation circuit in nuclear signal filtering and shaping algorithm 被引量:8
7
作者 Huai-Ping Wang Jian-Bin Zhou +5 位作者 Xiao-Ping Ouyang Xian-Guo Tuo Xu Hong Yi Liu Jie Yu You-Xian Jin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期85-94,共10页
In radiation measurement and digital nuclear spectrum systems,traditional nuclear signal processing circuits in nuclear electronics have been gradually replaced by digital algorithm modules with the application of hig... In radiation measurement and digital nuclear spectrum systems,traditional nuclear signal processing circuits in nuclear electronics have been gradually replaced by digital algorithm modules with the application of highperformance programmable hardware logic devices(such as FPGA or DSP).Referring to the digital realization method of inverse RC integral circuit systems,the function of the pole-zero cancellation(PZC)circuit was analyzed,a new modified cascade equivalent model of PZC was established,and the time-domain digital PZC(DPZC)recursive algorithm was derived in detail in this study.Two parameters kIand k_(D)are included in the new algorithm,where kIshould match the exponential decay time constant of the input signal to realize the pole-zero compensation,while the decay time constant of the output signal can be changed with the adjustable parameter k_(D)(which is larger than the decay time constant of the input signal).Based on the new DPZC algorithm module,two trapezoidal(triangular)shaping filters were designed and implemented.The amplitude–frequency characteristics of the output signal of the proposed trapezoidal shaping algorithm and the convolution trapezoidal shaping algorithm were compared,with fixed peaking time.The results show that the trapezoidal shaping algorithm based on DPZC can better suppress high-frequency noise.Finally,based on the Na I(Tl)scintillator(u75 mm×75 mm)detector and^(137)Cs source,the effect of the k_(D)value on the energy resolution of the DPZC trapezoidal(triangular)shaping algorithm was studied.The experimental results show that,with an increase in k_(D),the energy resolution of the system improved and reached the maximum when k_(D)was greater than 10,and the optimal energy resolution of the system was 7.72%. 展开更多
关键词 Pole-zero cancellation C–R inverse system Trapezoidal/triangular shaping Amplitude–frequency characteristics energy resolution
下载PDF
Performance of digital data acquisition system in gamma-ray spectroscopy 被引量:2
8
作者 Di-Wen Luo Hong-Yi Wu +9 位作者 Zhi-Huan Li Chuan Xu Hui Hua Xiang-Qing Li Xiang Wang Shuang-Quan Zhang Zhi-Qiang Chen Chen-Guang Wu Yu Jin Jie Lin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期12-22,共11页
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr... A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion. 展开更多
关键词 Digital data acquisition system Gamma spectroscopy energy resolution
下载PDF
Response functions of a 4π summing gamma detector in β-Oslo method 被引量:1
9
作者 Guo-Chun Yang Lei-Ming Hua +5 位作者 Fei Lu Jun Su Zhi-Hong Li Shi-Lun Jin Yang-Ping Shen Bing Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第6期9-17,共9页
The response functions of a 4π summing BGO detector were established using extensive experimental measurements and GEANT4 simulation. The partial and total efficiencies for all components of the γ-ray interaction wi... The response functions of a 4π summing BGO detector were established using extensive experimental measurements and GEANT4 simulation. The partial and total efficiencies for all components of the γ-ray interaction with the BGO detector were also measured. These response functions and efficiencies will be used in the β-Oslo method experiments to study the neutron capture cross sections of radioactive heavy ions. The application of the response functions of the BGO detector under simulated continuum γ-rays and source measurement γ-rays proves that the method and response functions are reliable. 展开更多
关键词 4πSumming BGO detector γ-Ray spectrum energy resolutions GEANT4 simulation
下载PDF
Characteristics of Nb/Al superconducting tunnel junctions fabricated using ozone gas 被引量:2
10
作者 Masahiro Ukibe Go Fujii Masataka Ohkubo 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第9期182-186,共5页
To improve the energy resolution(?E) of Nb/Al superconducting tunnel junctions(STJs), an ozone(O3) oxidation process has been developed to fabricate a thin defect-free tunnel barrier that simultaneously shows h... To improve the energy resolution(?E) of Nb/Al superconducting tunnel junctions(STJs), an ozone(O3) oxidation process has been developed to fabricate a thin defect-free tunnel barrier that simultaneously shows high critical current JC〉 1000 A/cm^2 and high normalized dynamic resistance RDA 〉 100 MΩ·μm^2, where A is the size of the STJ. The 50-μm^2 STJs produced by O3 exposure of 0.26 Pa·min with an indirect spray of O3 gas, which is a much lower level of exposure than the O2 exposure used in a conventional O2 oxidation process, exhibit a maximum JC= 800 A/cm^2 and a high RDA = 372 MΩ ·μm^2. The 100-pixel array of the 100-μm^2STJs produced using the same O3 oxidation conditions exhibits a constant leak current I leak= 14.9 ± 3.2 n A at a bias point around △ /e(where e is half the energy gap of an STJ),and a high fabrication yield of 87%. Although the I leak values are slightly larger than those of STJs produced using the conventional O2 oxidation process, the STJ produced using O3 oxidation shows a ?E = 10 eV for the C-Kα line, which is the best value of our Nb/Al STJ x-ray detectors. 展开更多
关键词 Nb/Al superconducting tunnel junctions high critical current density high energy resolution ozone
下载PDF
Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages
11
作者 Mebougna L. Drabo Stephen U. Egarievwe +4 位作者 Utpal N. Roy Benicia A. Harrison Carmella A. Goree Emmanuel K. Savage Ralph B. James 《Materials Sciences and Applications》 2020年第8期553-559,共7页
Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such... Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of <sup>241</sup>Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time. 展开更多
关键词 CdZnTeSe energy resolution energy-Peak Stability Gamma-Ray Spectroscopy Nuclear Detectors
下载PDF
Development of robust perovskite single crystal radiation detectors with high spectral resolution through synergetic trap deactivation and self-healing
12
作者 Lixiang Wang Yilong Song +8 位作者 Liqi Li Liting Tao Minxing Yan Weihui Bi Xueying Yang Yuan Sun Qingfeng Dong Deren Yang Yanjun Fang 《InfoMat》 SCIE CSCD 2023年第9期26-37,共12页
Organic-inorganic halide perovskite single crystals(SCs)are promising materials for detecting ionizing radiation owing to their outstanding photoelectric conversion capability and inexpensive solution processability.H... Organic-inorganic halide perovskite single crystals(SCs)are promising materials for detecting ionizing radiation owing to their outstanding photoelectric conversion capability and inexpensive solution processability.However,the accuracy and stability of the detectors have been limited due to the charge traps and defects in SCs,especially when operated under high-precision photon-counting mode for energy spectrum acquisition.Here,we proposed a trap freezing deactivation route,which obviously suppressed dark current and noise by up to 97%and 92%,respectively.Furthermore,the bulk ion migration effect was essential for the ability to instantly self-heal defects induced by radiation damage at temperatures down to30C.Consequently,the detector exhibits a record high energy resolution of 7.5%at 59.5 keV for 241Amγ-ray source,which is the best solution-processed semiconductor radiation detectors at the same energy range.In addition,the detector maintains over 90%of its initial performance after 9 months of storage when tested in the air.Our results will represent a revision of the paradigm that high-spectral-resolution and robust radiation detectors can only be realized with high temperature grown inorganic semiconductor single crystals. 展开更多
关键词 energy resolution perovskite single crystal photon counting radiation detector SELF-HEALING stability
原文传递
Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol
13
作者 Ezekiel O. Agbalagba Mebougna L. Drabo +5 位作者 Stephen U. Egarievwe Utpal N. Roy Amir H. Davis Mordecai B. Israel Parion L. Alexander Ralph B. James 《Materials Sciences and Applications》 2021年第8期363-373,共11页
Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of gr... Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10<sup>10</sup> Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of <sup>241</sup>Am. 展开更多
关键词 CdZnTeSe Chemical Etching energy resolution Gamma-Ray Spectroscopy Infrared Imaging Nuclear Detectors
下载PDF
Result of proton beam energy calibration of GECAM satellite charged particle detector
14
作者 Chaoyue Zhang Xiaohua Liang +22 位作者 Yanbing Xu Wenxi Peng Jianjian He Dongya Guo Ke Gong Yaqing Liu Zhenghua An Dali Zhang Sheng Yang Xiaojing Liu Xiangyang Wen Rui Qiao Jinzhou Wang Min Gao Shaolin Xiong Fan Zhang Xinqiao Li Xingzhu Cui Chaoyang Li Jilong Tang Xiaohua Wang Dengkui Wang Zhipeng Wei 《Radiation Detection Technology and Methods》 CSCD 2022年第1期26-34,共9页
Purpose A charged particle detector(CPD)is one of two main detectors on the GECAM satellite.It was designed to detect charged particles.Electrons and protons are space’s mainly charged particles.So,a research on the ... Purpose A charged particle detector(CPD)is one of two main detectors on the GECAM satellite.It was designed to detect charged particles.Electrons and protons are space’s mainly charged particles.So,a research on the proton detection ability of a CPD and deriving the energy response to charged particles of the CPD in the two designed operating modes is important.Method The proton calibration tests of the CPD under diferent working modes were carried out at the Heavy Ion Research Facility in Lanzhou.Result and conclusion Through testing and analysis,it was concluded that when CPD works in semi-component mode,it can detect the maximum energy,and when working in full-component mode,it can provide better energy resolution. 展开更多
关键词 GECAM Charged particle detector energy resolution E-C relation
原文传递
Property measurement of the CsI(Tl) crystal prepared at IMP 被引量:3
15
作者 陈若富 徐瑚珊 +14 位作者 樊瑞睿 詹文龙 肖国青 李松林 王建松 黄天衡 郑川 余玉洪 王猛 胡正国 叶飞 王玥 贾飞 岳珂 欧阳珍 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第2期135-138,共4页
Large-sized CsI(Tl) single crystals, -φ 0100 mm×350 mm, have been grown successfully, and this CsI(Tl) coupled with PD has been successfully utilized at RIBLL (the Radioactive Ion Beam Line in Lanzhou) to ... Large-sized CsI(Tl) single crystals, -φ 0100 mm×350 mm, have been grown successfully, and this CsI(Tl) coupled with PD has been successfully utilized at RIBLL (the Radioactive Ion Beam Line in Lanzhou) to measure the energy of heavy ions as a stopping detector. The performances of CsI(Tl) detector coupled with PD and APD have been tested and compared, including the temperature dependence of scintillating light yield. 展开更多
关键词 CsI(Tl) light yield energy resolution temperature dependence
原文传递
Micromegas prototypes with thermo-bond film separators 被引量:2
16
作者 管亮 唐浩辉 +3 位作者 郭军军 汪晓莲 许咨宗 赵天池 《Chinese Physics C》 SCIE CAS CSCD 2011年第2期163-168,共6页
In this paper we report the results of Micromegas prototypes constructed by attaching micromesh to an anode using thermo-bond films. The excellent metal attaching ability and good dielectical property of this kind of ... In this paper we report the results of Micromegas prototypes constructed by attaching micromesh to an anode using thermo-bond films. The excellent metal attaching ability and good dielectical property of this kind of film make it a promising material to be used as avalanche gap spacers. Several prototypes are successfully made. The electron transmission properties are first studied and then the gas gain is measured in argon-isobutane mixtures. The maximum gain of more than 104 is easily obtained. The energy resolutions for 55Fe 5.9 keV K~ ray can be better than 20% over one magnitude in gain for different operational gas mixtures and the best energy resolution of 13.7% (FWHM) can be achieved with the gas mixture of 94% argon concentration. The preliminary test results of the prototypes with sensitive area of 45 mm×45 mm without internal support show good uniformity across the sensitive area. 展开更多
关键词 MICROMEGAS thermo-bond film SEPARATOR electron transmission gain and energy resolution
原文传递
Experimental studies of THGEM in different Ar/CO_2 mixtures 被引量:2
17
作者 何占营 周健荣 +12 位作者 孙志嘉 杨桂安 许虹 王艳凤 刘倩 刘宏邦 陈石 谢一冈 郑阳恒 王晓冬 张小东 胡碧涛 陈元柏 《Chinese Physics C》 SCIE CAS CSCD 2014年第5期58-61,共4页
In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, w... In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, which is very suitable for application in neutron detection. In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is achieved from 720 V to 770 V, with a plateau slope of 2.4%/100 V, and an excellent energy resolution of about 22% is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source. 展开更多
关键词 THGEM counting rate plateau gas gain energy resolution
原文传递
A new gaseous detector—micro mesh gaseous structure 被引量:1
18
作者 唐浩辉 郭军军 +1 位作者 汪晓莲 许咨宗 《Chinese Physics C》 SCIE CAS CSCD 2009年第9期777-780,共4页
The structure and working principle of Micromegas (MICRO Mesh Gaseous Structure) is discussed. Some radiation sources of α and X rays are used to test this detector. The optimized electric-field intensity of the co... The structure and working principle of Micromegas (MICRO Mesh Gaseous Structure) is discussed. Some radiation sources of α and X rays are used to test this detector. The optimized electric-field intensity of the conversion gap is obtained. The transmission of electrons and the uniformity of the amplification gap are also presented. The energy resolution of the 5.9 keV peak is better than 27%. 展开更多
关键词 MICROMEGAS STRUCTURE electric field energy resolution UNIFORMITY
原文传递
A large-area GEM detector using a novel self-stretching technique 被引量:1
19
作者 尤文豪 周意 +5 位作者 李澄 陈宏芳 邵明 孙勇杰 唐泽波 刘建北 《Chinese Physics C》 SCIE CAS CSCD 2015年第4期51-54,共4页
A Gas Electron Multiplier (GEM) detector with an effective area of 300 mm×300 mm has been constructed using a novel self-stretching technique, which allows a highly flexible and efficient GEM detector assembly ... A Gas Electron Multiplier (GEM) detector with an effective area of 300 mm×300 mm has been constructed using a novel self-stretching technique, which allows a highly flexible and efficient GEM detector assembly free of glue or spacers. This makes the re-opening and repair of the GEM detectors possible and significantly reduces the scrap rate in the mass production of large-area GEM detectors. With the technique, the assembly time can be limited to a few hours, a factor of ten improvement compared to that using gluing techniques. The details of design and assembly procedure of the 300 mm×300 mm GEM detector are described in this paper. This detector was tested with 8 keV X-rays for the effective gain, energy resolution and performance uniformity. The results show that the typical energy resolution is 20% at an effective gain of about 10-4, with fairly good uniformity. 展开更多
关键词 GEM self-stretching effective gas gain energy resolution UNIFORMITY
原文传递
Experimental study of a THGEM detector with mini-rims 被引量:1
20
作者 章爱武 俞伯祥 +15 位作者 谢宇广 刘宏邦 安正华 王志刚 蔡啸 孙希磊 石峰 方建 薛镇 吕绮雯 孙丽君 葛永帅 刘颖彪 胡涛 周莉 吕军光 《Chinese Physics C》 SCIE CAS CSCD 2012年第2期142-145,共4页
The gas gain and energy resolution of single and double THGEM detectors (5 cm×5 cm effective area) with mini-rims (rim less than 10 um) were studied. The maximum gain was found to reach 5×103 and 2 ×... The gas gain and energy resolution of single and double THGEM detectors (5 cm×5 cm effective area) with mini-rims (rim less than 10 um) were studied. The maximum gain was found to reach 5×103 and 2 × 105 for single and double THGEMs respectively, while the energy resolution for 5.9 keV X-rays varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses. Different combinations were also investigated of noble gases (argon, neon) mixed with a quantity of other gases (isobutane, methane) at atmospheric pressure. 展开更多
关键词 THGEM gas gain energy resolution mini-rim
原文传递