Wave energy resources assessment is a very important process before the exploitation and utilization of the wave energy. At present, the existing wave energy assessment is focused on theoretical wave energy conditions...Wave energy resources assessment is a very important process before the exploitation and utilization of the wave energy. At present, the existing wave energy assessment is focused on theoretical wave energy conditions for interesting areas. While the evaluation for exploitable wave energy conditions is scarcely ever performed. Generally speaking, the wave energy are non-exploitable under a high sea state and a lower sea state which must be ignored when assessing wave energy. Aiming at this situation, a case study of the East China Sea and the South China Sea is performed. First, a division basis between the theoretical wave energy and the exploitable wave energy is studied. Next, based on recent 20 a ERA-Interim wave field data, some indexes including the spatial and temporal distribution of wave power density, a wave energy exploitable ratio, a wave energy level, a wave energy stability, a total wave energy density, the seasonal variation of the total wave energy and a high sea condition frequency are calculated. And then the theoretical wave energy and the exploitable wave energy are compared each other; the distributions of the exploitable wave energy are assessed and a regional division for exploitable wave energy resources is carried out; the influence of the high sea state is evaluated. The results show that considering collapsing force of the high sea state and the utilization efficiency for wave energy, it is determined that the energy by wave with a significant wave height being not less 1 m or not greater than 4 m is the exploitable wave energy. Compared with the theoretical wave energy, the average wave power density, energy level, total wave energy density and total wave energy of the exploitable wave energy decrease obviously and the stability enhances somewhat. Pronounced differences between the theoretical wave energy and the exploitable wave energy are present. In the East China Sea and the South China Sea, the areas of an abundant and stable exploitable wave energy are primarily located in the north-central part of the South China Sea, the Luzon Strait, east of Taiwan, China and north of Ryukyu Islands; annual average exploitable wave power density values in these areas are approximately 10-15 kW/m; the exploitable coefficient of variation (COV) and seasonal variation (SV) values in these areas are less than 1.2 and 1, respectively. Some coastal areas of the Beibu Gulf, the Changjiang Estuary, the Hangzhou Bay and the Zhujiang Estuary are the poor areas of the wave energy. The areas of the high wave energy exploitable ratio is primarily in nearshore waters. The influence of the high sea state for the wave energy in nearshore waters is less than that in offshore waters. In the areas of the abundant wave energy, the influence of the high sea state for the wave energy is prominent and the utilization of wave energy is relatively difficult. The developed evaluation method may give some references for an exploitable wave energy assessment and is valuable for practical applications.展开更多
Residential buildings are one of the major contributors to climate change due to their significant impacts on global energy consumption.Hence,most countries have introduced regulations to minimize energy use in reside...Residential buildings are one of the major contributors to climate change due to their significant impacts on global energy consumption.Hence,most countries have introduced regulations to minimize energy use in residential buildings.To date,the focus of these regulations has mainly been on operational energy while excluding embodied energy.In recent years,extensive studies have highlighted the necessity of minimizing both embodied energy and operational energy by applying the life-cycle energy assessment(LCEA)approach.However,the absence of a standardized framework and calculation methodology for the analysis of embodied energy has reportedly led to variations in the LCEA results.Retrospective research endeavoured to explore the causes of variations,with a limited focus on calculating embodied impacts.Despite the undertaken attempts,there is still a need to investigate the key parameters causing variations in LCEA results by examining methodological approaches of the current studies toward quantifications of embodied and operational energies.This paper aims to address three primary questions:‘what is the current trend of methodological approach for applying LCEA in residential buildings?’;‘what are the key parameters causing variations in LCEA results?’;and‘how can the continued variations in the application of LCEA in residential buildings be overcome?’.To this end,40 LCEA studies representing 157 cases of residential buildings across 16 countries have been critically reviewed.The findings reveal four principal categories of parameters that potentially contribute to the varying results of LCEAs:system boundary definition,calculation methods,geographical context,and interpretation of results.This paper also proposes a conceptual framework to minimize variations in LCEA studies by standardizing the process of conducting LCEAs.展开更多
A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need f...A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need for heating and has fixed internal heat gains as intended for compliance assessment. With the calculator, the effect of any parameter implemented can be immediately seen on delivered and primary energy. Because of simple equations, it is suitable for implementation into CAD (computer aided design) design tools including basic BIM (building information modeling) data. Results showed that the accuracy of the correlation for the cases with practical relevance was not worse than 14% of the energy need of space heating. This applies for passive house insulation level; for less insulated building envelopes, the deviations were smaller. This 14% equals to only 3 kWh/(m2.a), i.e., the percentage difference in the total delivered and primary energy was much lower because of other components in the energy balance. The deviations determined were implemented in the calculator as safety margin. Results prove that simple energy performance assessment based on specific heat loss coefficient is well justified for early stage energy analyses as well as for compliance assessment implemented in Estonian regulation.展开更多
China wind atlas was made by numerical simulation and the wind energy potential in China was calculated. The model system for wind energy resource assessment was set up based on Canadian Wind Energy Simulating Toolkit...China wind atlas was made by numerical simulation and the wind energy potential in China was calculated. The model system for wind energy resource assessment was set up based on Canadian Wind Energy Simulating Toolkit (WEST) and the simulating method was as follows. First, the weather classes were obtained depend on meteorological data of 30 years. Then, driven by the initial meteorological field produced by each weather class, the meso-scale model ran for the distribution of wind energy resources according each weather class condition one by one. Finally, averaging all the modeling output weighted by the occurrence frequency of each weather class, the annual mean distribution of wind energy resources was worked out. Compared the simulated wind energy potential with other results from several activities and studies for wind energy resource assessment, it is found that the simulated wind energy potential in mainland of China is 3 times that from the second and the third investigations for wind energy resources by CMA, and is similar to the wind energy potential obtained by NREL in Solar and Wind Energy Resource Assessment(SWERA) project. The simulated offshore wind energy potential of China seems smaller than the true value. According to the simulated results of CMA and considering lots of limited factors to wind energy development, the final conclusion can be obtained that the wind energy availability in China is 700~1 200 GW, in which 600~1 000 GW is in mainland and 100~200 GW is on offshore, and wind power will become the important part of energy composition in future.展开更多
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
The energy and environmental impacts resulting from the buildings sector are one of the impending problems which address the international action. The main strategies implemented to answer to this problem are the ener...The energy and environmental impacts resulting from the buildings sector are one of the impending problems which address the international action. The main strategies implemented to answer to this problem are the energy efficiency improvement, the CO2 emissions reduction and the renewable energy share increase in the energy mix. The key subject discussed in this paper is the "building energy impact", aimed to leading the building sector towards the energy efficiency improvement. The paper's aim is to show that an energy assessment is not able to give a consistent evaluation of building energy use, and it could be misleading. Therefore, the paper proposes the exergy assessment as complementary evaluation method, in order to achieve a complete description of the concept "building's energy impact on the environment". In the first section, we describe the parameters currently used for the building energy assessment, focusing on the primary energy index and the CO2 emissions index. In the second section, we introduce the exergy as a complementary index. This index is a possible answer to the problems previously identified. Finally, in the third section, we present three test-cases, analyzed through transient simulation software TRNSYS. The purpose of the test-cases analysis is to show the difference between energy and exergy assessment.展开更多
In 2005, an innovative program was formed between the local government and The University of Toledo to help improve environmental and economic conditions in Lucas County, Ohio, USA by providing no cost energy assessme...In 2005, an innovative program was formed between the local government and The University of Toledo to help improve environmental and economic conditions in Lucas County, Ohio, USA by providing no cost energy assessments to various types of organizations. Unlike the Industrial Assessment Centers, which focus on manufacturing and are funded by the Federal Government, this program demonstrates that successful partnerships can be established at the local government level to aid various types of organizations in energy conservation and cost reduction. Since 2005, the program completed ten energy assessments and identified over 143,000 kwh and 103,000 kg of CO2 for reduction. Additionally, over $12,000 has been identified as annual cost savings for Lucas County businesses. The purpose of this paper is to provide a complete overview and framework of this program so that other institutions may learn from it and adopt similar programs at the local level. A focus of this paper is a discussion of a case study that details the process and results of a typical energy assessment conducted through the project and comparison to similar programs in the US.展开更多
With the increasing severity of environmental problems,many countries have set energy transition targets to promote the realization of the Paris Agreement.There has been a global consensus on utilizing solar energy re...With the increasing severity of environmental problems,many countries have set energy transition targets to promote the realization of the Paris Agreement.There has been a global consensus on utilizing solar energy resources as alternatives to conventional sources to support this energy transition.In this regard,analyzing the“location,”“quantity,”and“quality”of global solar energy resources will not only assist an individual country to efficiently utilize these resources but also promote the realization of large-scale intercontinental resource utilization and complementation.This study established the basic database,model methods,and platform tools for global solar energy assessment,Then,a global solar energy resource assessment was conducted,which included the theoretical reserves(TRs),technical installed potential capacity(TPIC),and average development cost(ADC).A comparative analysis of the assessment results for all continents was also performed.After that,based on big data analysis and geographic information system(GIS)calculations,the distribution characteristics of the global solar power TPIC were calculated with the two core indicators,namely the capacity factor and ADC.Furthermore,a data-driven quantitative evaluation of the refined development potential of solar energy resources was performed.Finally,the reasonableness and coincidence analysis of the resource assessment results were verified using data from global and specifically Chinese photovoltaic(PV)bases.展开更多
Wave energy resource is a very important ocean renewable energy. A reliable assessment of wave energy resources must be performed before they can be exploited. Compared with wave model, altimeter can provide more accu...Wave energy resource is a very important ocean renewable energy. A reliable assessment of wave energy resources must be performed before they can be exploited. Compared with wave model, altimeter can provide more accurate in situ observations for ocean wave which can be as a novel method for wave energy assessment.The advantage of altimeter data is to provide accurate significant wave height observations for wave. In order to develop characteristic and advantage of altimeter data and apply altimeter data to wave energy assessment, in this study, we established an assessing method for wave energy in local sea area which is dedicated to altimeter data.This method includes three parts including data selection and processing, establishment of evaluation indexes system and criterion of regional division. Then a case study of Northwest Pacific was performed to discuss specific application for this method. The results show that assessing method in this paper can assess reserves and temporal and spatial distribution effectively and provide scientific references for the siting of wave power plants and the design of wave energy convertors.展开更多
Compressed air energy storage (CAES) systems represent a new technology for storing very large amount of energy. A peculiarity of the systems is that gas must be stored under a high pressure (p - 10-30 MPa). A lin...Compressed air energy storage (CAES) systems represent a new technology for storing very large amount of energy. A peculiarity of the systems is that gas must be stored under a high pressure (p - 10-30 MPa). A lined rock cavern (LRC) in the form of a tunnel or shaft can be used within this pressure range. The rock mass surrounding the opening resists the internal pressure and the lining ensures gas tightness. The present paper investigates the key aspects of technical feasibility of shallow LRC tunnels or shafts under a wide range of geotechnical conditions. Results show that the safety with respect to uplift failure of the rock mass is a necessary but not a sufficient condition for assessing feasibility. The deformation of the rock mass should also be kept sufficiently small to preserve the integrity of the lining and, especially, its tightness. If the rock is not sufficiently stiff, buckling or fatigue failure of the steel lining becomes more decisive when evaluating the feasible operating air pressure. The design of the concrete plug that seals the compressed air stored in the container is another demanding task. Numerical analyses indicate that in most cases, the stability of the rock mass under the plug loading is not a decisive factor for plug design.展开更多
The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severiti...The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severities, requiring only the information about the changes of a few lower natural frequencies. First, a damage quantification method is formulated and iterative approach is adopted for determining the damage extent. Then a damage localization algorithm is proposed, in which a damage indicator is formulated where unity value corresponds to the true damage scenario. Finally, numerical studies and model tests are conducted to demonstrate the effectiveness of the developed algorithm.展开更多
TiO_(2)has demonstrated outstanding performance in electrochemical advanced oxidation processes(EAOPs)due to its structural stability and high oxygen overpotential.However,there is still much room for improving its el...TiO_(2)has demonstrated outstanding performance in electrochemical advanced oxidation processes(EAOPs)due to its structural stability and high oxygen overpotential.However,there is still much room for improving its electrochemical activity.Herein,narrow bandgap manganese oxide(MnO_(x))was composited with TiO_(2)nanotube arrays(TiO_(2)NTAs)that in-situ oxidized on porous Ti sponge,forming the MnO_(x)-TiO_(2)NTAs anode.XANES and XPS analysis further proved that the composition of MnO_(x)is Mn2O3.Electrochemical characterizations revealed that increasing the composited concentration of MnO_(x)can improve the conductivity and reduce oxygen evolution potential so as to improve the electrochemical activity of the composited MnO_(x)-TiO_(2)NTAs anode.Meanwhile,the optimal degradation rate of benzoic acid(BA)was achieved using MnO_(x)-TiO_(2)NTAs with a MnO_(x)concentration of 0.1 mmol L^(-1),and the role of MnO_(x)was proposed based on DFT calculation.Additionally,the required electrical energy(EE/O)to destroy BA was optimized by varying the composited concentration of MnO_(x)and the degradation voltage.These quantitative results are of great significance for the design and application of high-performance materials for EAOPs.展开更多
An increasing number of marine structures have been built for coastal protection and marine development in recent years,and wind,which is crucial to marine structures,should be analyzed.Therefore,typhoon frequency,win...An increasing number of marine structures have been built for coastal protection and marine development in recent years,and wind,which is crucial to marine structures,should be analyzed.Therefore,typhoon frequency,wind climate,wind energy assess-ment,and extreme wind speed in the South China Sea(SCS)are investigated in detail in this study.The data are obtained from the China Meteorological Administration,the European Centre for Medium-range Weather Forecasts,and the National Centers for Envi-ronmental Prediction.The offshore wind energy potential is analyzed at five sites near the coast.The spatial and monthly frequencies of tropical cyclones for different intensity categories are analyzed.The extreme wind speed is fitted by five distribution models,and the generalized extreme value(GEV)distribution is selected as the most suitable function according to the goodness of fit.The spa-tial distributions of extreme wind speeds in the SCS are plotted on the basis of the GEV distribution and ERA5 data sets.The influ-ences of the distribution models and data sets on the calculated results are discussed.Moreover,the monthly extreme wind speed and comparison with the results of previous studies are analyzed.This study provides a reference for the design of wind turbines.展开更多
Simulation is recognized as an effective tool for building energy performance assessment during design or retrofit processes. Nevertheless, simulation models yield deviating outcomes from the actual building performan...Simulation is recognized as an effective tool for building energy performance assessment during design or retrofit processes. Nevertheless, simulation models yield deviating outcomes from the actual building performance and a significant portion of this deviation originates from the dynamic nature of occupant behavior. Literature on occupant behavior indicates that occupant behavior is not integrated into building energy performance assessment procedures with appropriate resolution, instead they are accepted as assumed and fixed data sets that usually represent the presence of occupants. This study attempts to evaluate the effect of diverse patterns of occupant behavior on energy performance simulation for office buildings. Diverse levels of sensitivity of occupant behavior on control-based activities such as using lighting apparatus, adjusting thermostat settings, and presence in space are employed through three diverse occupant behavior patterns. These occupancy patterns are correlated with three identical office spaces simulated within a conceptual office building. EDSL Tas is used to run building energy performance simulations. Effects of occupant behavior patterns on simulation outcomes are compared for five sample winter and summer workdays, with respect to heating and cooling loads. Results present findings on how diversity of occupancy profiles influences the consumption outcomes.展开更多
基金The Dragon III Project of the European Space Agency and Ministry of Science and Technology of China under contract No.10412the Ocean Renewable Energy Special Fund Project of State Oceanic Administration of China under contract No.GHME2011ZC07the National Natural Science Foundation of China(NSFC)under contract No.41176157
文摘Wave energy resources assessment is a very important process before the exploitation and utilization of the wave energy. At present, the existing wave energy assessment is focused on theoretical wave energy conditions for interesting areas. While the evaluation for exploitable wave energy conditions is scarcely ever performed. Generally speaking, the wave energy are non-exploitable under a high sea state and a lower sea state which must be ignored when assessing wave energy. Aiming at this situation, a case study of the East China Sea and the South China Sea is performed. First, a division basis between the theoretical wave energy and the exploitable wave energy is studied. Next, based on recent 20 a ERA-Interim wave field data, some indexes including the spatial and temporal distribution of wave power density, a wave energy exploitable ratio, a wave energy level, a wave energy stability, a total wave energy density, the seasonal variation of the total wave energy and a high sea condition frequency are calculated. And then the theoretical wave energy and the exploitable wave energy are compared each other; the distributions of the exploitable wave energy are assessed and a regional division for exploitable wave energy resources is carried out; the influence of the high sea state is evaluated. The results show that considering collapsing force of the high sea state and the utilization efficiency for wave energy, it is determined that the energy by wave with a significant wave height being not less 1 m or not greater than 4 m is the exploitable wave energy. Compared with the theoretical wave energy, the average wave power density, energy level, total wave energy density and total wave energy of the exploitable wave energy decrease obviously and the stability enhances somewhat. Pronounced differences between the theoretical wave energy and the exploitable wave energy are present. In the East China Sea and the South China Sea, the areas of an abundant and stable exploitable wave energy are primarily located in the north-central part of the South China Sea, the Luzon Strait, east of Taiwan, China and north of Ryukyu Islands; annual average exploitable wave power density values in these areas are approximately 10-15 kW/m; the exploitable coefficient of variation (COV) and seasonal variation (SV) values in these areas are less than 1.2 and 1, respectively. Some coastal areas of the Beibu Gulf, the Changjiang Estuary, the Hangzhou Bay and the Zhujiang Estuary are the poor areas of the wave energy. The areas of the high wave energy exploitable ratio is primarily in nearshore waters. The influence of the high sea state for the wave energy in nearshore waters is less than that in offshore waters. In the areas of the abundant wave energy, the influence of the high sea state for the wave energy is prominent and the utilization of wave energy is relatively difficult. The developed evaluation method may give some references for an exploitable wave energy assessment and is valuable for practical applications.
文摘Residential buildings are one of the major contributors to climate change due to their significant impacts on global energy consumption.Hence,most countries have introduced regulations to minimize energy use in residential buildings.To date,the focus of these regulations has mainly been on operational energy while excluding embodied energy.In recent years,extensive studies have highlighted the necessity of minimizing both embodied energy and operational energy by applying the life-cycle energy assessment(LCEA)approach.However,the absence of a standardized framework and calculation methodology for the analysis of embodied energy has reportedly led to variations in the LCEA results.Retrospective research endeavoured to explore the causes of variations,with a limited focus on calculating embodied impacts.Despite the undertaken attempts,there is still a need to investigate the key parameters causing variations in LCEA results by examining methodological approaches of the current studies toward quantifications of embodied and operational energies.This paper aims to address three primary questions:‘what is the current trend of methodological approach for applying LCEA in residential buildings?’;‘what are the key parameters causing variations in LCEA results?’;and‘how can the continued variations in the application of LCEA in residential buildings be overcome?’.To this end,40 LCEA studies representing 157 cases of residential buildings across 16 countries have been critically reviewed.The findings reveal four principal categories of parameters that potentially contribute to the varying results of LCEAs:system boundary definition,calculation methods,geographical context,and interpretation of results.This paper also proposes a conceptual framework to minimize variations in LCEA studies by standardizing the process of conducting LCEAs.
文摘A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need for heating and has fixed internal heat gains as intended for compliance assessment. With the calculator, the effect of any parameter implemented can be immediately seen on delivered and primary energy. Because of simple equations, it is suitable for implementation into CAD (computer aided design) design tools including basic BIM (building information modeling) data. Results showed that the accuracy of the correlation for the cases with practical relevance was not worse than 14% of the energy need of space heating. This applies for passive house insulation level; for less insulated building envelopes, the deviations were smaller. This 14% equals to only 3 kWh/(m2.a), i.e., the percentage difference in the total delivered and primary energy was much lower because of other components in the energy balance. The deviations determined were implemented in the calculator as safety margin. Results prove that simple energy performance assessment based on specific heat loss coefficient is well justified for early stage energy analyses as well as for compliance assessment implemented in Estonian regulation.
文摘China wind atlas was made by numerical simulation and the wind energy potential in China was calculated. The model system for wind energy resource assessment was set up based on Canadian Wind Energy Simulating Toolkit (WEST) and the simulating method was as follows. First, the weather classes were obtained depend on meteorological data of 30 years. Then, driven by the initial meteorological field produced by each weather class, the meso-scale model ran for the distribution of wind energy resources according each weather class condition one by one. Finally, averaging all the modeling output weighted by the occurrence frequency of each weather class, the annual mean distribution of wind energy resources was worked out. Compared the simulated wind energy potential with other results from several activities and studies for wind energy resource assessment, it is found that the simulated wind energy potential in mainland of China is 3 times that from the second and the third investigations for wind energy resources by CMA, and is similar to the wind energy potential obtained by NREL in Solar and Wind Energy Resource Assessment(SWERA) project. The simulated offshore wind energy potential of China seems smaller than the true value. According to the simulated results of CMA and considering lots of limited factors to wind energy development, the final conclusion can be obtained that the wind energy availability in China is 700~1 200 GW, in which 600~1 000 GW is in mainland and 100~200 GW is on offshore, and wind power will become the important part of energy composition in future.
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
文摘The energy and environmental impacts resulting from the buildings sector are one of the impending problems which address the international action. The main strategies implemented to answer to this problem are the energy efficiency improvement, the CO2 emissions reduction and the renewable energy share increase in the energy mix. The key subject discussed in this paper is the "building energy impact", aimed to leading the building sector towards the energy efficiency improvement. The paper's aim is to show that an energy assessment is not able to give a consistent evaluation of building energy use, and it could be misleading. Therefore, the paper proposes the exergy assessment as complementary evaluation method, in order to achieve a complete description of the concept "building's energy impact on the environment". In the first section, we describe the parameters currently used for the building energy assessment, focusing on the primary energy index and the CO2 emissions index. In the second section, we introduce the exergy as a complementary index. This index is a possible answer to the problems previously identified. Finally, in the third section, we present three test-cases, analyzed through transient simulation software TRNSYS. The purpose of the test-cases analysis is to show the difference between energy and exergy assessment.
文摘In 2005, an innovative program was formed between the local government and The University of Toledo to help improve environmental and economic conditions in Lucas County, Ohio, USA by providing no cost energy assessments to various types of organizations. Unlike the Industrial Assessment Centers, which focus on manufacturing and are funded by the Federal Government, this program demonstrates that successful partnerships can be established at the local government level to aid various types of organizations in energy conservation and cost reduction. Since 2005, the program completed ten energy assessments and identified over 143,000 kwh and 103,000 kg of CO2 for reduction. Additionally, over $12,000 has been identified as annual cost savings for Lucas County businesses. The purpose of this paper is to provide a complete overview and framework of this program so that other institutions may learn from it and adopt similar programs at the local level. A focus of this paper is a discussion of a case study that details the process and results of a typical energy assessment conducted through the project and comparison to similar programs in the US.
基金supported by National Science and Technology Major Project(2018YFB0904000).
文摘With the increasing severity of environmental problems,many countries have set energy transition targets to promote the realization of the Paris Agreement.There has been a global consensus on utilizing solar energy resources as alternatives to conventional sources to support this energy transition.In this regard,analyzing the“location,”“quantity,”and“quality”of global solar energy resources will not only assist an individual country to efficiently utilize these resources but also promote the realization of large-scale intercontinental resource utilization and complementation.This study established the basic database,model methods,and platform tools for global solar energy assessment,Then,a global solar energy resource assessment was conducted,which included the theoretical reserves(TRs),technical installed potential capacity(TPIC),and average development cost(ADC).A comparative analysis of the assessment results for all continents was also performed.After that,based on big data analysis and geographic information system(GIS)calculations,the distribution characteristics of the global solar power TPIC were calculated with the two core indicators,namely the capacity factor and ADC.Furthermore,a data-driven quantitative evaluation of the refined development potential of solar energy resources was performed.Finally,the reasonableness and coincidence analysis of the resource assessment results were verified using data from global and specifically Chinese photovoltaic(PV)bases.
基金The Dragon III Project of ESA-MOST Dragon Cooperation under contract No.10412the Ocean Renewable Energy Special Fund Project of State Oceanic Administration under contract No.GHME2011ZC07the National Natural Science Foundation of China(NSFC)under contract No.41176157
文摘Wave energy resource is a very important ocean renewable energy. A reliable assessment of wave energy resources must be performed before they can be exploited. Compared with wave model, altimeter can provide more accurate in situ observations for ocean wave which can be as a novel method for wave energy assessment.The advantage of altimeter data is to provide accurate significant wave height observations for wave. In order to develop characteristic and advantage of altimeter data and apply altimeter data to wave energy assessment, in this study, we established an assessing method for wave energy in local sea area which is dedicated to altimeter data.This method includes three parts including data selection and processing, establishment of evaluation indexes system and criterion of regional division. Then a case study of Northwest Pacific was performed to discuss specific application for this method. The results show that assessing method in this paper can assess reserves and temporal and spatial distribution effectively and provide scientific references for the siting of wave power plants and the design of wave energy convertors.
文摘Compressed air energy storage (CAES) systems represent a new technology for storing very large amount of energy. A peculiarity of the systems is that gas must be stored under a high pressure (p - 10-30 MPa). A lined rock cavern (LRC) in the form of a tunnel or shaft can be used within this pressure range. The rock mass surrounding the opening resists the internal pressure and the lining ensures gas tightness. The present paper investigates the key aspects of technical feasibility of shallow LRC tunnels or shafts under a wide range of geotechnical conditions. Results show that the safety with respect to uplift failure of the rock mass is a necessary but not a sufficient condition for assessing feasibility. The deformation of the rock mass should also be kept sufficiently small to preserve the integrity of the lining and, especially, its tightness. If the rock is not sufficiently stiff, buckling or fatigue failure of the steel lining becomes more decisive when evaluating the feasible operating air pressure. The design of the concrete plug that seals the compressed air stored in the container is another demanding task. Numerical analyses indicate that in most cases, the stability of the rock mass under the plug loading is not a decisive factor for plug design.
基金supported by the National Natural Science Foundation of China (50909088, 51010009)Science & Technology Development Project of Qingdao (09-1-3-18-jch)Program for New Century Excellent Talents in University (NCET-10-0762)
文摘The present paper develops a new method for damage localization and severity estimation based on the employment of modal strain energy. This method is able to determine the damage locations and estimate their severities, requiring only the information about the changes of a few lower natural frequencies. First, a damage quantification method is formulated and iterative approach is adopted for determining the damage extent. Then a damage localization algorithm is proposed, in which a damage indicator is formulated where unity value corresponds to the true damage scenario. Finally, numerical studies and model tests are conducted to demonstrate the effectiveness of the developed algorithm.
基金the support from the Brook Byers Institute for Sustainable Systems,Hightower ChairGeorgia Research Alliance at the Georgia Institute of Technology。
文摘TiO_(2)has demonstrated outstanding performance in electrochemical advanced oxidation processes(EAOPs)due to its structural stability and high oxygen overpotential.However,there is still much room for improving its electrochemical activity.Herein,narrow bandgap manganese oxide(MnO_(x))was composited with TiO_(2)nanotube arrays(TiO_(2)NTAs)that in-situ oxidized on porous Ti sponge,forming the MnO_(x)-TiO_(2)NTAs anode.XANES and XPS analysis further proved that the composition of MnO_(x)is Mn2O3.Electrochemical characterizations revealed that increasing the composited concentration of MnO_(x)can improve the conductivity and reduce oxygen evolution potential so as to improve the electrochemical activity of the composited MnO_(x)-TiO_(2)NTAs anode.Meanwhile,the optimal degradation rate of benzoic acid(BA)was achieved using MnO_(x)-TiO_(2)NTAs with a MnO_(x)concentration of 0.1 mmol L^(-1),and the role of MnO_(x)was proposed based on DFT calculation.Additionally,the required electrical energy(EE/O)to destroy BA was optimized by varying the composited concentration of MnO_(x)and the degradation voltage.These quantitative results are of great significance for the design and application of high-performance materials for EAOPs.
基金by the NSFC-Shandong Joint Fund(No.U1706226)the Fundamental Research Funds for the Central Universities.
文摘An increasing number of marine structures have been built for coastal protection and marine development in recent years,and wind,which is crucial to marine structures,should be analyzed.Therefore,typhoon frequency,wind climate,wind energy assess-ment,and extreme wind speed in the South China Sea(SCS)are investigated in detail in this study.The data are obtained from the China Meteorological Administration,the European Centre for Medium-range Weather Forecasts,and the National Centers for Envi-ronmental Prediction.The offshore wind energy potential is analyzed at five sites near the coast.The spatial and monthly frequencies of tropical cyclones for different intensity categories are analyzed.The extreme wind speed is fitted by five distribution models,and the generalized extreme value(GEV)distribution is selected as the most suitable function according to the goodness of fit.The spa-tial distributions of extreme wind speeds in the SCS are plotted on the basis of the GEV distribution and ERA5 data sets.The influ-ences of the distribution models and data sets on the calculated results are discussed.Moreover,the monthly extreme wind speed and comparison with the results of previous studies are analyzed.This study provides a reference for the design of wind turbines.
文摘Simulation is recognized as an effective tool for building energy performance assessment during design or retrofit processes. Nevertheless, simulation models yield deviating outcomes from the actual building performance and a significant portion of this deviation originates from the dynamic nature of occupant behavior. Literature on occupant behavior indicates that occupant behavior is not integrated into building energy performance assessment procedures with appropriate resolution, instead they are accepted as assumed and fixed data sets that usually represent the presence of occupants. This study attempts to evaluate the effect of diverse patterns of occupant behavior on energy performance simulation for office buildings. Diverse levels of sensitivity of occupant behavior on control-based activities such as using lighting apparatus, adjusting thermostat settings, and presence in space are employed through three diverse occupant behavior patterns. These occupancy patterns are correlated with three identical office spaces simulated within a conceptual office building. EDSL Tas is used to run building energy performance simulations. Effects of occupant behavior patterns on simulation outcomes are compared for five sample winter and summer workdays, with respect to heating and cooling loads. Results present findings on how diversity of occupancy profiles influences the consumption outcomes.