期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Study of n-γ discrimination in low energy range(above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector 被引量:3
1
作者 陈永浩 陈熙萌 +8 位作者 张小东 雷家荣 安力 邵剑雄 郑普 王新华 朱传新 何铁 阳剑 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期26-30,共5页
A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was... A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee). 展开更多
关键词 n-γ discrimination charge comparison method VME bus BC501A liquid scintillation detector low energy range
原文传递
A novel method to determine the FOCAL energy range
2
作者 张冬青 王向朝 施伟杰 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第10期589-592,共4页
Determination of the energy range is an important precondition of focus calibration using alignment procedure (FOCAL) test. A new method to determine the energy range of FOCAL off-lined is presented in this paper. I... Determination of the energy range is an important precondition of focus calibration using alignment procedure (FOCAL) test. A new method to determine the energy range of FOCAL off-lined is presented in this paper. Independent of the lithographic tool, the method is time-saving and effective. The influences of some process factors, e.g. resist thickness, post exposure bake (PEB) temperature, PEB time and development time, on the energy range of FOCAL are analyzed. 展开更多
关键词 LINE AO A novel method to determine the FOCAL energy range
原文传递
Absorption Range and Energy Shift of Surface Plasmon in Au Monomer and Dimer 被引量:2
3
作者 赵晓坤 姚湲 +4 位作者 郎佩琳 郭红莲 沈希 王岩国 禹日成 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第2期97-101,共5页
The resonance behaviors of local surface plasmon resonance in Au monomer and dimer are characterized sys- temically by electron energy loss spectroscopy in a scanning transmission electron microscope. The measured abs... The resonance behaviors of local surface plasmon resonance in Au monomer and dimer are characterized sys- temically by electron energy loss spectroscopy in a scanning transmission electron microscope. The measured absorption range is about 20nm larger than the physical size of the Au nanoparticles and the resonance peak energy shows a red shift when the electron beam passes off the nanoparticles. The Au dimer displays similar behaviors. Numerical simulation also reproduces those experimental results. 展开更多
关键词 of or on Absorption range and energy Shift of Surface Plasmon in Au Monomer and Dimer EELS in
下载PDF
Development of a fast neutron spectrometer based on a plastic fiber array
4
作者 Fan-Jian Zeng Li-Yang Sun +10 位作者 Kai Zhuang Heng An Yu-Xiong Xue Xiao-Ming Wang Dao-Wu Li Zhi-Ming Zhang Bao-Tong Feng Pei-Lin Wang Jia-Le Cai Xiu-Bo Qin De-Tian Li 《Radiation Detection Technology and Methods》 2017年第2期1-8,共8页
Objective A three-dimensional position-sensitive fast neutron spectrometer is designed to measure fast neutron spectrum over 10 MeV.Methods The detector consists of a 16×16 mutually perpendicular plastic scintill... Objective A three-dimensional position-sensitive fast neutron spectrometer is designed to measure fast neutron spectrum over 10 MeV.Methods The detector consists of a 16×16 mutually perpendicular plastic scintillation fiber array coupled to 2×2 Hamamatsu H8500C position-sensitive photomultiplier tubes by optical fibers.The fiber array is fabricated with 0.5 mm×3 mm fibers and 3-mm square fibers.Results Due to the combined application of different sizes of fibers,the detector can broaden energy dynamic range and meanwhile have good detection efficiency.The method of the combined application of different sizes of plastic fibers in the array may provide a solution to measure wider energy range of solar neutrons.Conclusion In this paper,we used FLUKA to simulate the performance of the detector model and report the results of experimental studies with neutrons from a pulsed D-T neutron. 展开更多
关键词 Fast neutron Different sizes Fiber array energy range
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部