期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Evaluation of Entrance Skin Dose from Paediatric Diagnostic X-Ray Examination
1
作者 Moromoke Oluwayemisi Adelayi Oladele Samuel Ajayi 《Open Journal of Radiology》 2023年第1期26-33,共8页
As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while consideri... As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while considering a number of other fickles. The ESD received by 50 paediatrics (aged 1-13 years) undergoing 8 types of X-ray examinations were measured at Federal Teaching Hospital, Ido-Ekiti, Ekiti, Nigeria, within a period of February 2019 to March 2020 using thermoluminescent dosimeters. The mean ± SD of ESDs were 0.85 ± 0.32, 2.04 ± 0.75, 0.60 ± 0.07, 0.62 ± 0.22, 0.57 ± 0.24, 1.75 ± 0.76, 0.93 ± 0.31 and 0.63 ± 0.06 mGy for Chest, Skull, Hand, Forearm, Knee, Abdomen, Leg and Feet, respectively. The mean ESDs were found to be within the recommended reference dose in all examinations, except for the Chest examination which was higher. The data obtained in this study will serve as existing data in Nigeria for future research works, as it would assist in optimizing dose to patients, especially the paediatrics. 展开更多
关键词 entrance Skin dose PAEDIATRICS X-Rays
下载PDF
Radiation Doses in Diagnostic Radiology and Method for Dose Reduction
2
作者 Taha M. Taha Hoda A. Ahmed Fathy A. Shaheen 《Open Journal of Radiology》 2023年第1期34-41,共8页
Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions a... Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions and generate a method for chest dose reduction to decrease radiation risk. Materials and Methods: The indirect dose measurement was used in the current research. The X-ray tube output was measured using RAD-CHECK Plus ionization chamber and the indirect entrance surface air kerma was calculated via applying physical acquisition parameters such as a focus on skin distance, tube current times exposure time (mAs), and applied tube voltage (kV), and applying a mathematical model. Results: The main findings were obtained from comparing the radiation doses with the reference levels of International organizations such as the American College of Radiology and the International Atomic Energy Authority. The mean entrance skin dose for the skull (AP), skull (PA), skull (LAT), cervical spine (PA), cervical spine (LAT), lumbar spine (AP), lumbar spine (LAT), pelvis (AP), and pelvis (LAT) of adult X-ray examinations was within the diagnostic reference dose level values obtained by ACR (2018) except for the ESD for chest (AP) which was 0.88 mGy. Conclusions: The results of the study concluded that by adjusting the applied tube voltage, kV, and tube current product time, mAs decreased the radiation dose to the chest X-ray by 58%. 展开更多
关键词 RADIOLOGY entrance Skin dose Chest X-Ray dose Minimization
下载PDF
Establishment of Local Diagnostic Reference Levels in Conventional Radiography: A Pilot Study in Dakar, Senegal
3
作者 Adji Yaram Diop Magatte Diagne +1 位作者 Ndeye Arame Boye Faye Mamadou Moustapha Dieng 《World Journal of Nuclear Science and Technology》 2022年第1期28-42,共15页
Diagnostic Reference Levels (DRLs) are indicators that allow assessing the quality of equipment and procedures from the point of view of the doses delivered to patients and subsequently initiate corrective actions if ... Diagnostic Reference Levels (DRLs) are indicators that allow assessing the quality of equipment and procedures from the point of view of the doses delivered to patients and subsequently initiate corrective actions if necessary. The purpose of this study is to encourage health professionals to investigate patient radiation doses and to determine whether those doses comply with the principles of radiation protection in medical fields so as to improve practices by reducing patient exposure without reducing clinical effectiveness. To perform this work, we have investigated patient doses for different radiological examinations from six (6) medical centers in Dakar, including the following nine routine types: chest (PA), abdomen (AP), pelvis (AP), cervical spine (AP), lumbar spine (AP, Lat), hip (AP), thoracic spine (AP, Lat). Three types of data were collected, <em>i.e.</em>, X-ray tube machine data, patient data and output measurements. The data were analyzed statistically and the median, minimum, maximum, and third quartile values were calculated and displayed throughout boxplots graphs for all exams and medical centers. The two sigma range (95% confidence interval) was also checked. Comparison of third quartiles of Entrance Surface Dose (ESD) and Dose Area Product (DAP) by type of examination with recommended international DRLs was performed. The third quartile of ESD for pelvis (AP) and thoracic spine (AP) was up to 16% and 38% higher, respectively than their corresponding DRLs in the European Commission Report RP 180 Part 2. For all exams, except thoracic spine (lat), the third quartiles of the dose area product were higher than the corresponding DRLs in the above report. The source of dose variability between medical centers was related to many parameters such as poor radiographic techniques, lack of modern X-ray machines and adequately documented radiation protection practices. The results show the need to develop protocols for dose measurement as well as to carry out quality assurance programs and dose optimization in Senegal. 展开更多
关键词 entrance Surface dose Diagnostic Radiology dose Area Product Optimization X-Rays
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部