A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELI...A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).展开更多
Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIE...Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIEA) was successfully developed for neomycin residue analysis. CLIEA demonstrated good cross-reactivity for neomycin, and the IC50 value was 2.4 ng/mL in buffer.展开更多
An electrochemical method for detection of cortisol based on capillary electrophoretic enzyme immunoassay has been developed. A limit of detection of 1.7?0-9 mol/L was obtained.
A Capillary electrophortic enzyme linked immunoassay with electrochemical detection (CE-EIA-ED) has been developed. The method can be used to determine thyroxine with a limit of 3.8×10-9 mol/L.
BACKGROUND Current diagnosis of hepatitis C virus(HCV)infection requires two sequential steps:testing for anti-HCV followed by HCV RNA PCR to confirm viremia.We have developed a highly sensitive and specific HCV-antig...BACKGROUND Current diagnosis of hepatitis C virus(HCV)infection requires two sequential steps:testing for anti-HCV followed by HCV RNA PCR to confirm viremia.We have developed a highly sensitive and specific HCV-antigens enzyme immunoassay(HCV-Ags EIA)for one-step diagnosis of viremic HCV infection.AIM To assess the clinical application of the HCV-Ags EIA in one-step diagnosis of viremic HCV infection in human immunodeficiency virus(HIV)-coinfected individuals.METHODS The study blindly tested HCV-Ags EIA for its performance in one-step diagnosing viremic HCV infection in 147 sera:10 without HCV or HIV infection;54 with viremic HCV monoinfection;38 with viremic HCV/HIV coinfection;and 45 with viremic HCV and non-viremic HIV coinfection.RESULTS Upon decoding,it was 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR test.In five sera with HCV infection,HCV RNA was as low as 50-59 IU/mL,and four out of five tested positive for HCV-Ags EIA.Likewise,it was also 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR in 83 sera with HCV and HIV coinfection,regardless if HIV infection was active or not.CONCLUSION The modified HCV-Ags EIA has a lower detection limit equivalent to serum HCV RNA levels of approximately 100 IU/mL.It is highly sensitive and specific in the setting of HIV coinfection,regardless of HIV infection status and CD4 count.These data support the clinical application of the HCV-Ags EIA in one-step diagnosis of HCV infection in HIV-infected individuals.展开更多
[Objective] The research aimed to establish a rapid detection method for Shigella. [Method] Combining immunomagnetic separation technology with ATP bioluminescence technology, a new kind of fast and accurate ATP biolu...[Objective] The research aimed to establish a rapid detection method for Shigella. [Method] Combining immunomagnetic separation technology with ATP bioluminescence technology, a new kind of fast and accurate ATP bioluminescence magnetic enzyme immunoassay technique for Shigella was established. [Result] Using ATP bioluminescence magnetic enzyme immunoassay technique to detect standard solution for Shigella (ATCC 25931 ), result showed that correlation coefficient between relative light intensity detected by instrument and bacteria concentration detec- ted by culture counting method was 0.981 1. Moreover, relation curve between relative light intensity and Shigella concentration was drawn. [ Conclusion] The method had a high detection speed and accuracy, and could be used for the rapid detection of pathogen in food and environment.展开更多
The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney t...The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood trough concentrations (Co) of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 〈1 month, (281.4± 57.9)ng/mL; 2 - 3 months, (264.5 ± 41.2) ng/mL; 4 - 5 months, (236.4 ± 38.9) ng/mL; 6 - 12 months, (206.5± 32.6)ng/mL; 〉12 months, (185.6± 28.1)ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1%, significantly lower than that of the none-recommended dose group (37.2%) (P〈0.05); the transplantation rejection rate was 4.4%, significantly lower than that of the none- recommended dose group (22.5%) (P〈0.05). Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect.展开更多
A new voltammetric enzyme immunoassay system was investigated based on p-nitrophenyl phosphate (PNPP) as the substrate for alkaline phosphatase (ALP). PNPP is enzymatically hydrolyzed and the product p-nitrophenol (P...A new voltammetric enzyme immunoassay system was investigated based on p-nitrophenyl phosphate (PNPP) as the substrate for alkaline phosphatase (ALP). PNPP is enzymatically hydrolyzed and the product p-nitrophenol (PNP) is detected by differential pulse voltammetry (DPV), which can be oxidized at +1.02 V (vs. Ag/AgCl) on bare glass carbon electrode (GCE). The conditions for enzymatic reaction and electrochemical detection were studied. According to this method, ALP can be detected with a detection limit of 2.8102 mU/L and a linear range of 4.0102 ~ 1.0106 mU/L.展开更多
Tumor marker CA15-3 was determined by using capillary electrophoretic enzyme immunoassay with electrochemical detection (CE-EIA-ED). The method can be used to detect CA15-3 with a limit of 0.024 U/mL.
A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was teste...A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was tested and PR level was calculated by the regression equation. Correlation analysis revealed that there was a linear relationship between different concentrations of the standard PR samples and the corresponding values of luminosity: Y=3748+463.77X, γ=0 9958. The values of the luminosity in 38 cases of tumor tissues were determined with the highest being 267.32 fmol/mg, the lowest 3.69 fmol/mg and the mean 78.53 fmol/mg. The new method of CLEIA was a stable, creditable,specific and sensitive assay for determination of PR.展开更多
Objective.To evaluate the clinical utility of a new non-invasive enzyme immunoassay(EIA)for the diagnosis of Helicobacter pylori(H.pylori)infection.Methods.Stool specimens of63patients were collected and tested by usi...Objective.To evaluate the clinical utility of a new non-invasive enzyme immunoassay(EIA)for the diagnosis of Helicobacter pylori(H.pylori)infection.Methods.Stool specimens of63patients were collected and tested by using a commercial kit for detecting Helicobacter pylori stool antigen(HpSA),of which61patients also underwent 13 C-Urea breath test( 13 C-UBT).The tissue samples of31patients were obtained endoscopically and were examined with histologic technique(Warthin-Starry silver stain).Regarded 13 C-UBT as a golden standard,HpSA test and histologic techniques were evaluated.Using this method,we also investigated the positive rate of H.pylori infection in children in Beijing.Results.The sensitivity and specificity of HpSA test were94.7%and95.1%respectively;the posi-tive and negative predictive values were97.3%and91.7%respectively;and the accuracy was95.1%.The results showed the prevalence of H.pylori infection was26.0%in children(3~18years)of district of Xicheng in Beijing.After treatment ,HpSA seems to disappear rapidly(3~5days)from the feces.Conclusion.The detection of HpSA in stool samples by HpSA test is a rapid noninvasive test for detecting H.pylori infection,and has both high sensitivity and high specificity.It is suitable for screening and diagnosis of H.pylori infection,monitoring the treatment efficacy in routine in all hospitals.展开更多
The activity of the Ab-bound enzyme(HRP)changed after immunochemical reaction,and can be indicated by a sensitive fluorimetric kinetic method.The finding set the stage for developing sensitive homogeneous immunoassay....The activity of the Ab-bound enzyme(HRP)changed after immunochemical reaction,and can be indicated by a sensitive fluorimetric kinetic method.The finding set the stage for developing sensitive homogeneous immunoassay.AFP was measured as an example.展开更多
During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNI...During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNIP-Ab on the membrane increased over 30-fold when compared with the unconjugated Ab.Thus we used this characteristic to develop a novel immunoassay method-polymer enzyme linked immunoassay method: homogeneous antigen-antibody reaction and heterogeneous separation process. When applied for detection of human serum HBsAg, this immunoassay system can detect as little as 1 ng/ml of human serum HBsAg.展开更多
Objective:To evaluate the value of enhanced luminescence enzyme immunoassay in the diagnosis of Neisseria gonorrhea(NG) infection. Methods: Anti-catalase antibody for Neisseria gonorrheae combined with enhanced lumine...Objective:To evaluate the value of enhanced luminescence enzyme immunoassay in the diagnosis of Neisseria gonorrhea(NG) infection. Methods: Anti-catalase antibody for Neisseria gonorrheae combined with enhanced luminescence enzyme immunoassay were used to test for N. gonorrhea. Results: A minimum of 1×10^4/CFU of GC in genital tract secretions or urine could be detected with the technique of luminescence enzyme immunoassay. Conclusion : The enhanced luminescence enzyme immunoassay has the advantage of high sensitivity and specificity for diagnosing NG from genitourinary tract secretion and urine.展开更多
We previously developed radioimmunoassays (RIAs) for digitoxin and digoxin using antisera raised against digitoxin 3’-hemisuccinate-bovine serum albumin and digoxin 3’-hemisuccinate-bovine serum albumin conjugates, ...We previously developed radioimmunoassays (RIAs) for digitoxin and digoxin using antisera raised against digitoxin 3’-hemisuccinate-bovine serum albumin and digoxin 3’-hemisuccinate-bovine serum albumin conjugates, respectively. Very recently, we converted the RIA for digoxin to an enzyme immunoassay (EIA) system. Here, we aimed to convert the RIA for digitoxin to an EIA suitable for measuring serum digitoxin level in patients, using digitoxin 3’-hemisuccinate-β-D-galactosidase as an enzyme-labeled antigen. The developed EIA showed a quantification range of 1 to 70 ng/mL and exhibited high specificity for digitoxin, with low cross-reactivity to digitoxin metabolites. Compared with a commercial anti-digitoxin antiserum clinically used to monitor serum digitoxin level in patients, our antiserum showed much higher specificity for intact digitoxin. Intra- and inter-assay variations were less than 10.0% and 8.5%, respectively. Recovery was within the range of 93.7% - 107.5%. Mean digitoxin concentrations measured in serum samples (n = 26) from digitoxin-treated patients by EIA using our new antiserum and the commercial anti-digitoxin antiserum were 11.0 and 13.8 ng/mL, respectively. The present EIA, which is superior to RIA in terms of convenience and disposal of waste materials, is expected to be practically useful for clinical monitoring of intact digitoxin in serum.展开更多
基金supported by the National Basic Research Program of China (973 Program,no. 2007CB714507)National Nature Science Foundation of China (no. 90813015)
文摘A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).
基金supported by the project for talent training and development of the China National Center for Food Safety Risk Assessment(523 plan)Natural Science Foundation of Guangdong Province(No.2014A030310289 and No.2016A020210055)+1 种基金Natural Science Foundation of SZU(No.201576)National Natural Science Foundation of China(No.21107104)
文摘Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIEA) was successfully developed for neomycin residue analysis. CLIEA demonstrated good cross-reactivity for neomycin, and the IC50 value was 2.4 ng/mL in buffer.
基金This project was supported by the National Natural Science Foundation of Chinathe Natural Science Foundation of Shandong Province and the State Key Laboratory of Electroanalytical Chemistry,Changchun Institute of Applied Chemistry,Chinese Academy of Science.
文摘An electrochemical method for detection of cortisol based on capillary electrophoretic enzyme immunoassay has been developed. A limit of detection of 1.7?0-9 mol/L was obtained.
基金supported by the National Natural Science Foundation of Chinathe Natural Science Foundation of Shandong Provincethe Key State Laboratory of Electroanalytical Chemistry,Changchun Institute of Applied Chemistry,Chinese Academy of Sciences
文摘A Capillary electrophortic enzyme linked immunoassay with electrochemical detection (CE-EIA-ED) has been developed. The method can be used to determine thyroxine with a limit of 3.8×10-9 mol/L.
文摘BACKGROUND Current diagnosis of hepatitis C virus(HCV)infection requires two sequential steps:testing for anti-HCV followed by HCV RNA PCR to confirm viremia.We have developed a highly sensitive and specific HCV-antigens enzyme immunoassay(HCV-Ags EIA)for one-step diagnosis of viremic HCV infection.AIM To assess the clinical application of the HCV-Ags EIA in one-step diagnosis of viremic HCV infection in human immunodeficiency virus(HIV)-coinfected individuals.METHODS The study blindly tested HCV-Ags EIA for its performance in one-step diagnosing viremic HCV infection in 147 sera:10 without HCV or HIV infection;54 with viremic HCV monoinfection;38 with viremic HCV/HIV coinfection;and 45 with viremic HCV and non-viremic HIV coinfection.RESULTS Upon decoding,it was 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR test.In five sera with HCV infection,HCV RNA was as low as 50-59 IU/mL,and four out of five tested positive for HCV-Ags EIA.Likewise,it was also 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR in 83 sera with HCV and HIV coinfection,regardless if HIV infection was active or not.CONCLUSION The modified HCV-Ags EIA has a lower detection limit equivalent to serum HCV RNA levels of approximately 100 IU/mL.It is highly sensitive and specific in the setting of HIV coinfection,regardless of HIV infection status and CD4 count.These data support the clinical application of the HCV-Ags EIA in one-step diagnosis of HCV infection in HIV-infected individuals.
文摘[Objective] The research aimed to establish a rapid detection method for Shigella. [Method] Combining immunomagnetic separation technology with ATP bioluminescence technology, a new kind of fast and accurate ATP bioluminescence magnetic enzyme immunoassay technique for Shigella was established. [Result] Using ATP bioluminescence magnetic enzyme immunoassay technique to detect standard solution for Shigella (ATCC 25931 ), result showed that correlation coefficient between relative light intensity detected by instrument and bacteria concentration detec- ted by culture counting method was 0.981 1. Moreover, relation curve between relative light intensity and Shigella concentration was drawn. [ Conclusion] The method had a high detection speed and accuracy, and could be used for the rapid detection of pathogen in food and environment.
基金supported by the Project 973 Monitoring of the Immune Status and Rejection After Organ Transplantation"(2009CB522400)the National Natural Science Foundation of China(No.30972947)
文摘The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood trough concentrations (Co) of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 〈1 month, (281.4± 57.9)ng/mL; 2 - 3 months, (264.5 ± 41.2) ng/mL; 4 - 5 months, (236.4 ± 38.9) ng/mL; 6 - 12 months, (206.5± 32.6)ng/mL; 〉12 months, (185.6± 28.1)ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1%, significantly lower than that of the none-recommended dose group (37.2%) (P〈0.05); the transplantation rejection rate was 4.4%, significantly lower than that of the none- recommended dose group (22.5%) (P〈0.05). Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect.
基金The work was supported by the National Natural Science Foundation of China(Grant No.20075013)the Natural Science Foundation of Shandong Province(Grant No.Y98B06025).
文摘A new voltammetric enzyme immunoassay system was investigated based on p-nitrophenyl phosphate (PNPP) as the substrate for alkaline phosphatase (ALP). PNPP is enzymatically hydrolyzed and the product p-nitrophenol (PNP) is detected by differential pulse voltammetry (DPV), which can be oxidized at +1.02 V (vs. Ag/AgCl) on bare glass carbon electrode (GCE). The conditions for enzymatic reaction and electrochemical detection were studied. According to this method, ALP can be detected with a detection limit of 2.8102 mU/L and a linear range of 4.0102 ~ 1.0106 mU/L.
文摘Tumor marker CA15-3 was determined by using capillary electrophoretic enzyme immunoassay with electrochemical detection (CE-EIA-ED). The method can be used to detect CA15-3 with a limit of 0.024 U/mL.
文摘A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was tested and PR level was calculated by the regression equation. Correlation analysis revealed that there was a linear relationship between different concentrations of the standard PR samples and the corresponding values of luminosity: Y=3748+463.77X, γ=0 9958. The values of the luminosity in 38 cases of tumor tissues were determined with the highest being 267.32 fmol/mg, the lowest 3.69 fmol/mg and the mean 78.53 fmol/mg. The new method of CLEIA was a stable, creditable,specific and sensitive assay for determination of PR.
文摘Objective.To evaluate the clinical utility of a new non-invasive enzyme immunoassay(EIA)for the diagnosis of Helicobacter pylori(H.pylori)infection.Methods.Stool specimens of63patients were collected and tested by using a commercial kit for detecting Helicobacter pylori stool antigen(HpSA),of which61patients also underwent 13 C-Urea breath test( 13 C-UBT).The tissue samples of31patients were obtained endoscopically and were examined with histologic technique(Warthin-Starry silver stain).Regarded 13 C-UBT as a golden standard,HpSA test and histologic techniques were evaluated.Using this method,we also investigated the positive rate of H.pylori infection in children in Beijing.Results.The sensitivity and specificity of HpSA test were94.7%and95.1%respectively;the posi-tive and negative predictive values were97.3%and91.7%respectively;and the accuracy was95.1%.The results showed the prevalence of H.pylori infection was26.0%in children(3~18years)of district of Xicheng in Beijing.After treatment ,HpSA seems to disappear rapidly(3~5days)from the feces.Conclusion.The detection of HpSA in stool samples by HpSA test is a rapid noninvasive test for detecting H.pylori infection,and has both high sensitivity and high specificity.It is suitable for screening and diagnosis of H.pylori infection,monitoring the treatment efficacy in routine in all hospitals.
文摘The activity of the Ab-bound enzyme(HRP)changed after immunochemical reaction,and can be indicated by a sensitive fluorimetric kinetic method.The finding set the stage for developing sensitive homogeneous immunoassay.AFP was measured as an example.
文摘During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNIP-Ab on the membrane increased over 30-fold when compared with the unconjugated Ab.Thus we used this characteristic to develop a novel immunoassay method-polymer enzyme linked immunoassay method: homogeneous antigen-antibody reaction and heterogeneous separation process. When applied for detection of human serum HBsAg, this immunoassay system can detect as little as 1 ng/ml of human serum HBsAg.
文摘Objective:To evaluate the value of enhanced luminescence enzyme immunoassay in the diagnosis of Neisseria gonorrhea(NG) infection. Methods: Anti-catalase antibody for Neisseria gonorrheae combined with enhanced luminescence enzyme immunoassay were used to test for N. gonorrhea. Results: A minimum of 1×10^4/CFU of GC in genital tract secretions or urine could be detected with the technique of luminescence enzyme immunoassay. Conclusion : The enhanced luminescence enzyme immunoassay has the advantage of high sensitivity and specificity for diagnosing NG from genitourinary tract secretion and urine.
文摘We previously developed radioimmunoassays (RIAs) for digitoxin and digoxin using antisera raised against digitoxin 3’-hemisuccinate-bovine serum albumin and digoxin 3’-hemisuccinate-bovine serum albumin conjugates, respectively. Very recently, we converted the RIA for digoxin to an enzyme immunoassay (EIA) system. Here, we aimed to convert the RIA for digitoxin to an EIA suitable for measuring serum digitoxin level in patients, using digitoxin 3’-hemisuccinate-β-D-galactosidase as an enzyme-labeled antigen. The developed EIA showed a quantification range of 1 to 70 ng/mL and exhibited high specificity for digitoxin, with low cross-reactivity to digitoxin metabolites. Compared with a commercial anti-digitoxin antiserum clinically used to monitor serum digitoxin level in patients, our antiserum showed much higher specificity for intact digitoxin. Intra- and inter-assay variations were less than 10.0% and 8.5%, respectively. Recovery was within the range of 93.7% - 107.5%. Mean digitoxin concentrations measured in serum samples (n = 26) from digitoxin-treated patients by EIA using our new antiserum and the commercial anti-digitoxin antiserum were 11.0 and 13.8 ng/mL, respectively. The present EIA, which is superior to RIA in terms of convenience and disposal of waste materials, is expected to be practically useful for clinical monitoring of intact digitoxin in serum.