Electrochemical quartz crystal impedance system (EQCIS) which allows in situ dynamic quartz crystal impedance measurement in an electrochemical experiment was developed by combining an HP 4395A Network/Spectrum/Impeda...Electrochemical quartz crystal impedance system (EQCIS) which allows in situ dynamic quartz crystal impedance measurement in an electrochemical experiment was developed by combining an HP 4395A Network/Spectrum/Impedance analyzer with an EG&G M283 potentiostat. Equivalent circuit parameters of crystal resonance change significantly during electrodeposition and dissolution of copper in 0.1 mol/L H2SO4 aqueous solution in a cyclic potential sweep experiment, which is explained with an overall picture of mass loading, solution density and viscosity, etc..展开更多
The electrochemical quartz crystal impedance system (EQCIS) has been used for the study of a partially immersed Au electrode in 0.2 mol/L NaClO4 aqueous solution. The influences of the immersed area and height of the ...The electrochemical quartz crystal impedance system (EQCIS) has been used for the study of a partially immersed Au electrode in 0.2 mol/L NaClO4 aqueous solution. The influences of the immersed area and height of the electrode on the EQCIS responses were evaluated, showing the highest response sensitivity to liquid loading at the center of the piezoelectric quartz crystal electrode. The increase in the immersed height of the Au electrode at oxygen reduction potentials during potential cycling was measured by this technique.展开更多
The campontely structured inductive waveguide elements are analyzed by making use ofthe equivalent source method in this paper The number and cross section of the inductive posts are arbi-trary, and they are of rither...The campontely structured inductive waveguide elements are analyzed by making use ofthe equivalent source method in this paper The number and cross section of the inductive posts are arbi-trary, and they are of rither pure metallic or pure dielectric lype , or composed of both metallic and di-electric ones. A number of inductive waveguide elements are numerically analyzed and a good agree-ment is achieved in comiparison with the measured data or results available in published literalures.展开更多
We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary...We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary electrophoresis(I.D.50μm,O.D. 360μm,electrode length of 4 mm,electrode gap of 1 mm,frequency of 200 kHz),the values of C_w measured in 1 and 20 mmol/L NaCl solutions are 2.8 and 32 fF,which are only 1.1%and 12%of prediction by the equation in references,respectively.The value of R_S is less than the prediction in solutions withκ〈0.02 S/m.The response current of C^4D is due to the change in C_w because the total impedance of a C^4D is composed mainly by the impedance from C_w.展开更多
文摘Electrochemical quartz crystal impedance system (EQCIS) which allows in situ dynamic quartz crystal impedance measurement in an electrochemical experiment was developed by combining an HP 4395A Network/Spectrum/Impedance analyzer with an EG&G M283 potentiostat. Equivalent circuit parameters of crystal resonance change significantly during electrodeposition and dissolution of copper in 0.1 mol/L H2SO4 aqueous solution in a cyclic potential sweep experiment, which is explained with an overall picture of mass loading, solution density and viscosity, etc..
基金This work was supported by the National Natural Science Foundation of China the Science and Technology Foundation of Hunan P
文摘The electrochemical quartz crystal impedance system (EQCIS) has been used for the study of a partially immersed Au electrode in 0.2 mol/L NaClO4 aqueous solution. The influences of the immersed area and height of the electrode on the EQCIS responses were evaluated, showing the highest response sensitivity to liquid loading at the center of the piezoelectric quartz crystal electrode. The increase in the immersed height of the Au electrode at oxygen reduction potentials during potential cycling was measured by this technique.
文摘The campontely structured inductive waveguide elements are analyzed by making use ofthe equivalent source method in this paper The number and cross section of the inductive posts are arbi-trary, and they are of rither pure metallic or pure dielectric lype , or composed of both metallic and di-electric ones. A number of inductive waveguide elements are numerically analyzed and a good agree-ment is achieved in comiparison with the measured data or results available in published literalures.
基金supported by the National Natural Science Foundation of China(nos.20975062 and 21175084)
文摘We report a resonant method to measure the wall capacitance(C_w) and solution resistance(R_S) in a capacitively coupled contactless conductivity detector(C^4D).Under the typical operating conditions in capillary electrophoresis(I.D.50μm,O.D. 360μm,electrode length of 4 mm,electrode gap of 1 mm,frequency of 200 kHz),the values of C_w measured in 1 and 20 mmol/L NaCl solutions are 2.8 and 32 fF,which are only 1.1%and 12%of prediction by the equation in references,respectively.The value of R_S is less than the prediction in solutions withκ〈0.02 S/m.The response current of C^4D is due to the change in C_w because the total impedance of a C^4D is composed mainly by the impedance from C_w.