期刊文献+
共找到104篇文章
< 1 2 6 >
每页显示 20 50 100
A Combined Antenna Array Deployment with High Positioning Accuracy and Low Angular Measurement Error
1
作者 Wangjie Chen Weiqiang Zhu +3 位作者 Zhenhong Fan Li Wu Yi He Yixiao Wang 《Journal of Beijing Institute of Technology》 EI CAS 2024年第2期141-154,共14页
In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de... In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems. 展开更多
关键词 antenna array deployment ambiguity resolution phase consistency angle measurement error positioning error
下载PDF
Online Capacitor Voltage Transformer Measurement Error State Evaluation Method Based on In-Phase Relationship and Abnormal Point Detection
2
作者 Yongqi Liu Wei Shi +2 位作者 Jiusong Hu Yantao Zhao Pang Wang 《Smart Grid and Renewable Energy》 2024年第1期34-48,共15页
The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the... The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%. 展开更多
关键词 Capacitor Voltage Transformer measurement error Online Monitoring Principal Component Analysis Local Outlier Factor
下载PDF
Tightly coupled INS/CNS/spectral redshift integrated navigation system with the aid of redshift error measurement
3
作者 GAO GuangLe GAO SheSheng +2 位作者 HU GaoGe ZHONG YongMin PENG Xu 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第9期2597-2610,共14页
The integration of an inertial navigation system(INS) and a celestial navigation system(CNS) has the superiority of high autonomy. However, its reliability and accuracy are permanently impaired under poor observation ... The integration of an inertial navigation system(INS) and a celestial navigation system(CNS) has the superiority of high autonomy. However, its reliability and accuracy are permanently impaired under poor observation conditions. To address this issue, the present paper proposes a tightly coupled INS/CNS/spectral redshift(SRS) integration framework based on the spectral redshift error measurement. In the proposed method, a spectral redshift error measurement equation is investigated and embedded in the traditional tightly coupled INS/CNS integrated navigation system to achieve better anti-interference under complicated circumstances. Subsequently, the inaccurate redshift estimation from the low signal-to-noise ratio spectrum is considered in the integrated system, and an improved chi-square test-based covariance estimation method is incorporated in the federated Kalman filter, allowing to deal with measurement outliers caused by the inaccurate redshift estimation but not influencing the effect of other correct redshift measurements in suppressing the error of the navigation parameter on the filtering solution. Simulations and comprehensive analyses demonstrate that the proposed tightly coupled INS/CNS/SRS integrated navigation system can effectively handle outliers and outages under hostile observation conditions, resulting in improved performance. 展开更多
关键词 INS/CNS integrated navigation spectral redshift navigation spectral redshift error measurement equation inaccurate spectral redshift FAULT-TOLERANCE
原文传递
Effect of Measurement Error on the Multivariate CUSUM Control Chart for Compositional Data
4
作者 Muhammad Imran Jinsheng Sun +2 位作者 Fatima Sehar Zaidi Zameer Abbas Hafiz Zafar Nazir 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1207-1257,共51页
Control charts(CCs)are one of the main tools in Statistical Process Control that have been widely adopted in manufacturing sectors as an effective strategy for malfunction detection throughout the previous decades.Mea... Control charts(CCs)are one of the main tools in Statistical Process Control that have been widely adopted in manufacturing sectors as an effective strategy for malfunction detection throughout the previous decades.Measurement errors(M.E’s)are involved in the quality characteristic of interest,which can effect the CC’s performance.The authors explored the impact of a linearmodel with additive covariate M.E on the multivariate cumulative sum(CUSUM)CC for a specific kind of data known as compositional data(CoDa).The average run length(ARL)is used to assess the performance of the proposed chart.The results indicate that M.E’s significantly affects themultivariate CUSUM-CoDaCCs.The authors haveused theMarkov chainmethod to study the impact of different involved parameters using six different cases for the variance-covariance matrix(VCM)(i.e.,uncorrelated with equal variances,uncorrelated with unequal variances,positively correlated with equal variances,positively correlated with unequal variances,negatively correlatedwith equal variances and negatively correlated with unequal variances).The authors concluded that the error VCM has a negative impact on the performance of themultivariate CUSUM-CoDa CC,as the ARL increases with an increase in the value of the error VCM.The subgroup size m and powering operator b positively impact the proposed CC,as the ARL decreases with an increase in m or b.The number of variables p also has a negative impact on the performance of the proposed CC,as the values of ARL increase with an increase in p.For the implementation of the proposal,two illustrated examples have been reported formultivariate CUSUM-CoDaCCs inthe presence ofM.E’s.Onedealswith themanufacturingprocessof uncoated aspirin tablets,and the other is based on monitoring the machines involved in the muesli manufacturing process. 展开更多
关键词 MCUSUM chart CODA measurement error manufacturing process PERFORMANCE
下载PDF
Robust ensemble of metamodels based on the hybrid error measure
5
作者 Shuai HUANG Bo WU +3 位作者 Xin ZHANG Aman ELMI Youmin HU Wenwen JIN 《Frontiers of Mechanical Engineering》 SCIE CSCD 2021年第3期623-634,共12页
Metamodels have been widely used as an alternative for expensive physical experiments or complex,time-consuming computational simulations to provide a fast but accurate analysis.However,challenge remains in the prior ... Metamodels have been widely used as an alternative for expensive physical experiments or complex,time-consuming computational simulations to provide a fast but accurate analysis.However,challenge remains in the prior determination of the most suitable metamodel for a particular case because of the lack of information about the actual behavior of a system.In addition,existing studies on metamodels have largely restricted on solving deterministic problems(e.g.,data from finite element models),whereas some real-life engineering problems(e.g.,data from physical experiment)are stochastic problems with noisy data.In this work,a robust ensemble of metamodels(EMs)is proposed by combining three regression stand-alone metamodels in a weighted sum form.The weight factor is adaptively determined according to the hybrid error metric,which combines global and local error measures to improve the accuracy of the EMs.Furthermore,three typical individual metamodels that can filter noise are selected to construct the EMs to extend their application in practical engineering problems.Three well-known benchmark problems with different levels of noise and three engineering problems are used to verify the effectiveness of the proposed EMs.Results show that the proposed EMs have higher accuracy and robustness than the individual metamodels and other typical EMs in major cases. 展开更多
关键词 METAMODEL ensemble of metamodels hybrid error measure stochastic problem
原文传递
Errors and Correction of Precipitation Measurements in China 被引量:10
6
作者 任芝花 黎明琴 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2007年第3期449-458,共10页
In order to discover the range of various errors in Chinese precipitation measurements and seek a correction method, 30 precipitation evaluation stations were set up countrywide before 1993. All the stations are refer... In order to discover the range of various errors in Chinese precipitation measurements and seek a correction method, 30 precipitation evaluation stations were set up countrywide before 1993. All the stations are reference stations in China. To seek a correction method for wind-induced error, a precipitation correction instrument called the "horizontal precipitation gauge" was devised beforehand. Field intercomparison observations regarding 29,000 precipitation events have been conducted using one pit gauge, two elevated operational gauges and one horizontal gauge at the above 30 stations. The range of precipitation measurement errors in China is obtained by analysis of intercomparison measurement results. The distribution of random errors and systematic errors in precipitation measurements are studied in this paper. A correction method, especially for wind-induced errors, is developed. The results prove that a correlation of power function exists between the precipitation amount caught by the horizontal gauge and the absolute difference of observations implemented by the operational gauge and pit gauge. The correlation coefficient is 0.99. For operational observations, precipitation correction can be carried out only by parallel observation with a horizontal precipitation gauge. The precipitation accuracy after correction approaches that of the pit gauge. The correction method developed is simple and feasible. 展开更多
关键词 precipitation evaluation stations intercomparison measurements precipitation measurement errors correction method
下载PDF
Residual lifetime prediction model of nonlinear accelerated degradation data with measurement error 被引量:12
7
作者 Zhongyi Cai Yunxiang Chen +1 位作者 Qiang Zhang Huachun Xiang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2017年第5期1028-1038,共11页
For the product degradation process with random effect (RE), measurement error (ME) and nonlinearity in step-stress accelerated degradation test (SSADT), the nonlinear Wiener based degradation model with RE and ME is ... For the product degradation process with random effect (RE), measurement error (ME) and nonlinearity in step-stress accelerated degradation test (SSADT), the nonlinear Wiener based degradation model with RE and ME is built. An analytical approximation to the probability density function (PDF) of the product's lifetime is derived in a closed form. The process and data of SSADT are analyzed to obtain the relation model of the observed data under each accelerated stress. The likelihood function for the population-based observed data is constructed. The population-based model parameters and its random coefficient prior values are estimated. According to the newly observed data of the target product in SSADT, an analytical approximation to the PDF of its residual lifetime (RL) is derived in accordance with its individual degradation characteristics. The parameter updating method based on Bayesian inference is applied to obtain the posterior value of random coefficient of the RL model. A numerical example by simulation is analyzed to verify the accuracy and advantage of the proposed model. 展开更多
关键词 accelerated degradation test residual lifetime (RL) prediction measurement error random effect NONLINEARITY
下载PDF
WEIGHTED LASSO ESTIMATES FOR SPARSE LOGISTIC REGRESSION:NON-ASYMPTOTIC PROPERTIES WITH MEASUREMENT ERRORS 被引量:2
8
作者 Huamei HUANG Yujing GAO +1 位作者 Huiming ZHANG Bo LI 《Acta Mathematica Scientia》 SCIE CSCD 2021年第1期207-230,共24页
For high-dimensional models with a focus on classification performance,the?1-penalized logistic regression is becoming important and popular.However,the Lasso estimates could be problematic when penalties of different... For high-dimensional models with a focus on classification performance,the?1-penalized logistic regression is becoming important and popular.However,the Lasso estimates could be problematic when penalties of different coefficients are all the same and not related to the data.We propose two types of weighted Lasso estimates,depending upon covariates determined by the Mc Diarmid inequality.Given sample size n and a dimension of covariates p,the finite sample behavior of our proposed method with a diverging number of predictors is illustrated by non-asymptotic oracle inequalities such as the?1-estimation error and the squared prediction error of the unknown parameters.We compare the performance of our method with that of former weighted estimates on simulated data,then apply it to do real data analysis. 展开更多
关键词 logistic regression weighted Lasso oracle inequalities high-dimensional statistics measurement error
下载PDF
Real time remaining useful life prediction based on nonlinear Wiener based degradation processes with measurement errors 被引量:22
9
作者 唐圣金 郭晓松 +3 位作者 于传强 周志杰 周召发 张邦成 《Journal of Central South University》 SCIE EI CAS 2014年第12期4509-4517,共9页
Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degrad... Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degradation process, the measurement error is not considered and forecasting uncertainty is large. Therefore, an approximate analytical RUL distribution in a closed-form of a nonlinear Wiener based degradation process with measurement errors was proposed. The maximum likelihood estimation approach was used to estimate the unknown fixed parameters in the proposed model. When the newly observed data are available, the random parameter is updated by the Bayesian method to make the estimation adapt to the item's individual characteristic and reduce the uncertainty of the estimation. The simulation results show that considering measurement errors in the degradation process can significantly improve the accuracy of real time RUL prediction. 展开更多
关键词 remaining useful life Wiener based degradation process measurement error nonlinear maximum likelihood estimation Bayesian method
下载PDF
High Resolution Clinometers for Measurement of Roll Error Motion of a Precision Linear Slide 被引量:1
10
作者 Yuki Shimizu Satoshi Kataoka Wei Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第5期8-16,共9页
This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linea... This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linear slide, where the roll error motion measurement will be carried out repeatedly to confirm whether the surface form errors of slide guideways in the linear slide are su ciently corrected by hand scraping process. In the proposed method, one of the clinometers is mounted on the slide table, while the other is placed on a vibration isolation table, on which the precision linear slide is mounted, so that influences of external disturbances can be cancelled. An experimental setup is built on a vibration isolation table, and some experiments are carried out to verify the feasibility of the proposed method. 展开更多
关键词 Linear slide Clinometer Rotational error motion measurement
下载PDF
Parameter-independent error correction for potential measurements by reference electrode in lithium-ion batteries 被引量:1
11
作者 Yalun Li Xinlei Gao +4 位作者 Xuning Feng Xuebing Han Jiuyu Du Languang Lu Minggao Ouyang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第4期34-45,共12页
The safety monitoring of lithium-ion batteries(LIBs) is of great significance for realizing all-climate and full-lifespan battery management. In-situ measurement of anode potential with implanted reference electrodes(... The safety monitoring of lithium-ion batteries(LIBs) is of great significance for realizing all-climate and full-lifespan battery management. In-situ measurement of anode potential with implanted reference electrodes(REs) has proven to be effective to monitor and avoid the occurrence of severe side reactions like Li plating to ensure the safe and fast charging. However, the intrinsic measurement errors caused by local blocking effects, which also can be referred to as potential artefacts, are seldom taken into consideration in existing studies, yet they highly dominate the correctness of conclusions inferred from REs. In this study, aiming at exploring the physical origin of the measurement errors and ensure reliable potential monitoring, electrochemical and post-mortem tests are conducted using commercial pouch cells with implanted REs. Corresponding electrochemical model which describes the blocking effects, is established to validate the abnormal absence of lithium plating that predicted by measured anode potentials under various charging rates. Theoretical derivation is further presented to explain the error sources, which can be attributed to increased local liquid potential of the RE position. Most importantly, with the guidance of error analysis, a novel parameter-independent error correction method for RE measurements is proposed for the first time, which is proven to be adequate to estimate the real anode potentials and deduce the critical C-rate of Li plating with extra safety margin. After error correction, the resulting critical C-rates are all within the range of 0.55 ± 0.03 C, which is close to the C-rate of 0.6–0.7 C obtained from experiments. In addition, this error correction method can be performed conveniently with only some simple RE measurements of polarization voltages, totally independent of battery electrochemical and geometric parameters. This study provides highly practical error correction method for RE measurements in real LIBs, substantially facilitating the fast diagnosis and safety evaluation of Li plating during charging of LIBs. 展开更多
关键词 Reference electrode Lithium-ion battery Potential artefacts measurement error correction
下载PDF
Empirical Bayes Test for the Parameter of Rayleigh Distribution with Error of Measurement 被引量:1
12
作者 HUANG JUAN 《Communications in Mathematical Research》 CSCD 2011年第1期17-23,共7页
For the data with error of measurement in historical samples, the empirical Bayes test rule for the parameter of Rayleigh distribution is constructed, and the asymptotically optimal property is obtained. It is shown t... For the data with error of measurement in historical samples, the empirical Bayes test rule for the parameter of Rayleigh distribution is constructed, and the asymptotically optimal property is obtained. It is shown that the convergence rate of the proposed EB test rule can be arbitrarily close to O(n-1/2) under suitable conditions. 展开更多
关键词 error of measurement empirical Bayes asymptotic optimality convergence rate
下载PDF
Positional Error Model of Line Segments with Modeling and Measuring Errors Using Brownian Bridge 被引量:1
13
作者 Xiaohua TONG Lejingyi ZHOU Yanmin JIN 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期1-10,共10页
Spatial linear features are often represented as a series of line segments joined by measured endpoints in surveying and geographic information science.There are not only the measuring errors of the endpoints but also... Spatial linear features are often represented as a series of line segments joined by measured endpoints in surveying and geographic information science.There are not only the measuring errors of the endpoints but also the modeling errors between the line segments and the actual geographical features.This paper presents a Brownian bridge error model for line segments combining both the modeling and measuring errors.First,the Brownian bridge is used to establish the position distribution of the actual geographic feature represented by the line segment.Second,an error propagation model with the constraints of the measuring error distribution of the endpoints is proposed.Third,a comprehensive error band of the line segment is constructed,wherein both the modeling and measuring errors are contained.The proposed error model can be used to evaluate line segments’overall accuracy and trustability influenced by modeling and measuring errors,and provides a comprehensive quality indicator for the geospatial data. 展开更多
关键词 spatial data line segment modeling error measuring error Brownian bridge
下载PDF
THE ASYMPTOTIC DISTRIBUTIONS OF EMPIRICAL LIKELIHOOD RATIO STATISTICS IN THE PRESENCE OF MEASUREMENT ERROR
14
作者 伍长春 张润楚 《Acta Mathematica Scientia》 SCIE CSCD 2007年第2期232-242,共11页
Suppose that several different imperfect instruments and one perfect instrument are independently used to measure some characteristics of a population. Thus, measurements of two or more sets of samples with varying ac... Suppose that several different imperfect instruments and one perfect instrument are independently used to measure some characteristics of a population. Thus, measurements of two or more sets of samples with varying accuracies are obtained. Statistical inference should be based on the pooled samples. In this article, the authors also assumes that all the imperfect instruments are unbiased. They consider the problem of combining this information to make statistical tests for parameters more relevant. They define the empirical likelihood ratio functions and obtain their asymptotic distributions in the presence of measurement error. 展开更多
关键词 Empirical likelihood ratio statistics asymptotic distribution measurement error
下载PDF
Measurement Error of Refractive Index for Spectacle Lens
15
作者 叶佳意 蒋伟忠 唐玲玲 《Journal of Donghua University(English Edition)》 EI CAS 2017年第4期613-616,共4页
As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement er... As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement error,the experimental results are analyzed,which include right angle deviation,contact liquid,curvature,and focusing accuracy. The study results show that focusing accuracy is the most important factor of influence for measurement,consists of contact liquid wettability,sample shape,and effective width of light transmission. In addition,the refractive index measurement is less affected by angle deviation of sample and the refractive index deviation of contact liquid. On the basis of the experimental data analysis,it is possible to relax the deviation of right angle of the sample to 1' or 2'. 展开更多
关键词 spectacles lens refractive index measurement error V prism refractometer
下载PDF
Accuracy estimation of site coordinates derived from GNSS-observations by non-classical error theory of measurements
16
作者 Petro Dvulit Stepan Savchuk Iryna Sosonka 《Geodesy and Geodynamics》 CSCD 2021年第5期347-355,共9页
The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of... The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of a systematic nature, which can significantly affect the reliability of the obtained velocity estimates. This research shows that using non-classical error theory of measurement(NETM)for processing GNSS time series allows detecting the presence of weak, not removed from GNSS processing, sources of systematic errors. Based on the coordinate time series of selected permanent GNSS stations in Europe, we checked the empirical distributions of errors by the NETM on G. Jeffries’ recommendations and on the principles of the theory of hypothesis tests according to Pearson’s criterion. It is established that the obtained coordinates time series of GNSS-stations only partially confirm the hypothesis of their conformity to the normal Gaussian distribution law, and this may be the main reason for their unrepresentative classification. In the future, it is necessary to identify and take into account the causes of residual errors that distort the real distribution of the results of the GNSS time series. 展开更多
关键词 GNSS data Processing GNSS time Series Discontinuities in time series Non-classical error theory of measurements Noise analysis
下载PDF
Nonparametric Regression Estimation with Mixed Measurement Errors
17
作者 Zanhua Yin Fang Liu Yuanfu Xie 《Applied Mathematics》 2016年第17期2269-2284,共17页
We consider the estimation of nonparametric regression models with predictors being measured with a mixture of Berkson and classical errors. In practice, the Berkson error arises when the variable X of interest is uno... We consider the estimation of nonparametric regression models with predictors being measured with a mixture of Berkson and classical errors. In practice, the Berkson error arises when the variable X of interest is unobservable and only a proxy of X can be measured while the inaccuracy related to the observation of the proxy causes an error of classical type. In this paper, we propose two nonparametric estimators of the regression function in the presence of either or both types of errors. We prove the asymptotic normality of our estimators and derive their rates of convergence. The finite-sample properties of the estimators are investigated through simulation studies. 展开更多
关键词 Berkson error Classical error DECONVOLUTION Kernel Method Mixed measurement errors
下载PDF
A Steady-State Errors Correction Method for Eliminating Measurement Errors
18
作者 田新良 杨苹 《Journal of Donghua University(English Edition)》 EI CAS 2013年第4期298-304,共7页
This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In c... This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications. 展开更多
关键词 measurement errors steady-state errors correction (SSEC) active power filters (APF)CLC number:TM77Document code:AArticle ID:1672-5220(2013)04-0298-07
下载PDF
Analysis and counter measure in blood grouping errors of volunteers’donating blood
19
《中国输血杂志》 CAS CSCD 2001年第S1期378-,共1页
关键词 Analysis and counter measure in blood grouping errors of volunteers
下载PDF
Algorithms for automatic measurement of SIS-type hysteretic underdamped Josephson junction’s parameters by current-voltage characteristics
20
作者 Aleksey G.Vostretsov Svetlana G.Filatova 《Journal of Electronic Science and Technology》 EI CSCD 2023年第4期60-74,共15页
Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic nois... Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic noise level of measuring instruments.This leads to the need for multiple measurements with subsequent statistical processing.In this paper,the digital algorithms are proposed for the automatic measurement of the JJ parameters by IVC.These algorithms make it possible to implement multiple measurements and check these JJ parameters in an automatic mode with the required accuracy.The complete sufficient statistics are used to minimize the root-mean-square error of parameter measurement.A sequence of current pulses with slow rising and falling edges is used to drive JJ,and synchronous current and voltage readings at JJ are used to realize measurement algorithms.The algorithm performance is estimated through computer simulations.The significant advantage of the proposed algorithms is the independence from current source noise and intrinsic noise of current and voltage meters,as well as the simple implementation in automatic digital measuring systems.The proposed algorithms can be used to control JJ parameters during mass production of superconducting integrated circuits,which will improve the production efficiency and product quality. 展开更多
关键词 Algorithm design and analysis Critical current Current-voltage characteristics(IVCs) Josephson junction(JJ) measurement errors Parameter estimation
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部