Basing on some researchers' experimental results,the droplet impinging wall model was modified,and We Number and K Number were adopted to determine the mode of droplet impinging wall.The simulation results indicat...Basing on some researchers' experimental results,the droplet impinging wall model was modified,and We Number and K Number were adopted to determine the mode of droplet impinging wall.The simulation results indicated that the mode of impinging droplet is sticking on the wall in Muti-spout bed.The droplet impinging wall model modified can describe the droplet impinging wall phenomenon accurately in the multistage spouted fluidized flue gas desulfurization reactor.Basing on the study above,the distributions of temperature and relative humidity in the reactor were attained.In atomization region,the distribution of temperature exhibits "M" shape.The relative humidity exhibits"W"shape.The mass concentration of droplet reduces along axis of the reactor.Due to the multi-spouted configuration,droplet concentration increases obviously in the intersection region between the 1st and 2nd stage reaction region.The evaporating intensity reaches its peak value in the area of 200 mm away from the sprayer,and droplets are completely evaporated at 1500 mm.展开更多
In this study,the evaporation characteristics and drying patterns of various sessile ferrofluid droplets on certain substrate under horizontal magnetic fields of controlled intensities are reported.The effects of drop...In this study,the evaporation characteristics and drying patterns of various sessile ferrofluid droplets on certain substrate under horizontal magnetic fields of controlled intensities are reported.The effects of droplet concentration and magnetic field intensity on the duration of each evaporation stage and drying patterns of droplets have been systematically investigated.It turned out that a plateau appears at the initial stage of evaporation in the absence of magnetic field and it was found that the plateau value is positively correlated with the concentration of ferrofluid droplets.Under the external magnetic field,the evaporation time of droplets decreases,the stage of contact line retreat extends,the stage of late pinning mode shortens,and the deposition area of ferrofluid droplet decreases compared to that of without magnetics field.The deposition area increases gradually and becomes more uniform with the increase of magnetic field.The decrease of friction force which is due to the decrease of the number of nanoparticles at the contact line under external magnetic field is the main reason for the observed phenomena.We found that the coffee ring and the uniform deposition inside the droplet will be destroyed when the magnetic field intensity is higher than a critical value.Our work has a significant reference value for the evaporation of sessile magnetic fluid droplets under the applied magnetic field,especially when the drying pattern needs to be precisely controlled,such as in spray or biomedicine.展开更多
基金Sponsored by the National High Technology Research and Development Program of China(Grant 2007AA05Z3374)the Key Projects in the National Science & Technology Pillar Program during the Eleventh Five-Year Plan Period(Grant No.2006BAA01B04)
文摘Basing on some researchers' experimental results,the droplet impinging wall model was modified,and We Number and K Number were adopted to determine the mode of droplet impinging wall.The simulation results indicated that the mode of impinging droplet is sticking on the wall in Muti-spout bed.The droplet impinging wall model modified can describe the droplet impinging wall phenomenon accurately in the multistage spouted fluidized flue gas desulfurization reactor.Basing on the study above,the distributions of temperature and relative humidity in the reactor were attained.In atomization region,the distribution of temperature exhibits "M" shape.The relative humidity exhibits"W"shape.The mass concentration of droplet reduces along axis of the reactor.Due to the multi-spouted configuration,droplet concentration increases obviously in the intersection region between the 1st and 2nd stage reaction region.The evaporating intensity reaches its peak value in the area of 200 mm away from the sprayer,and droplets are completely evaporated at 1500 mm.
基金The authors gratefully acknowledge the financial support of the National Natural Science Foundation of China(Grants No.52025061 and 51961130386)Royal Society-Newton Advanced Fellowship(Grant No.NAF/R1/191163)This work was also supported by the China Fundamental Research Funds for the Central Universities.
文摘In this study,the evaporation characteristics and drying patterns of various sessile ferrofluid droplets on certain substrate under horizontal magnetic fields of controlled intensities are reported.The effects of droplet concentration and magnetic field intensity on the duration of each evaporation stage and drying patterns of droplets have been systematically investigated.It turned out that a plateau appears at the initial stage of evaporation in the absence of magnetic field and it was found that the plateau value is positively correlated with the concentration of ferrofluid droplets.Under the external magnetic field,the evaporation time of droplets decreases,the stage of contact line retreat extends,the stage of late pinning mode shortens,and the deposition area of ferrofluid droplet decreases compared to that of without magnetics field.The deposition area increases gradually and becomes more uniform with the increase of magnetic field.The decrease of friction force which is due to the decrease of the number of nanoparticles at the contact line under external magnetic field is the main reason for the observed phenomena.We found that the coffee ring and the uniform deposition inside the droplet will be destroyed when the magnetic field intensity is higher than a critical value.Our work has a significant reference value for the evaporation of sessile magnetic fluid droplets under the applied magnetic field,especially when the drying pattern needs to be precisely controlled,such as in spray or biomedicine.