期刊文献+
共找到41篇文章
< 1 2 3 >
每页显示 20 50 100
Comparative study of functional optical zone:small incision lenticule extraction versus femtosecond laser assisted excimer laser keratomileusis 被引量:2
1
作者 Yao-Wen Song Meng-Fan Cui +3 位作者 Yi Feng Min Qu Yan Gao Rui He 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期238-244,共7页
AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential as... AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group. 展开更多
关键词 functional optical zone small incision lenticule extraction femtosecondlaser assisted excimer laser keratomileusis spherical equivalent spherical aberration
下载PDF
Smaller Ge Quantum Dots Obtained by ArF Excimer Laser Annealing
2
作者 曾玉刚 韩根全 余金中 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第4期641-644,共4页
Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bul... Ge self-assembled quantum dots (SAQDs) are grown with a self-assembled UHV/CVD epitaxy system. Then, the as-grown Ge quantum dots are annealed by ArF excimer laser. In the ultra-shot laser pulse duration, -20ns, bulk diffusion is forbidden,and only surface diffusion occurs, resulting in a laser induced quantum dot (LIQD). The diameter of the LIQD is 20-25nm which is much smaller than the as-grown dot and the LIQD has a higher density of about 6 ×10^10cm^-2. The surface morphology evolution is investigated by AFM. 展开更多
关键词 Ge quantum dot ArF excimer laser annealing LIQD AFM
下载PDF
Excimer laser coronary atherectomy for a severe calcified coronary ostium lesion:A case report 被引量:2
3
作者 Fang-Jie Hou Xiao-Teng Ma +1 位作者 Yu-Jie Zhou Jun Guan 《World Journal of Clinical Cases》 SCIE 2021年第34期10666-10670,共5页
BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment fo... BACKGROUND Percutaneous coronary intervention can be challenging for ostial coronary artery lesions due to calcium burden and elastic fiber content.Excimer laser coronary atherectomy(ELCA)is a less common treatment for severe calcified coronary ostium lesions.CASE SUMMARY An 81-year-old male presented to the Cardiology Department of Qingdao Municipal Hospital with a 1-year history of chest pain.Coronary angiography showed severe calcific stenosis(approximately 90%)in the right coronary artery ostium.The right coronary artery ostium was unable to be advanced using a 2.5 mm×12.0 mm balloon(NC Sprinter,Medtronic,United States)or dilated using a 2.0 mm×12.0 mm balloon(Sprinter,Medtronic,United States).The patient underwent successful ELCA and balloon dilation of the calcified coronary ostium lesion.CONCLUSION ELCA appears to be a safe and effective treatment for the management of severe calcified coronary ostium lesions. 展开更多
关键词 excimer laser coronary atherectomy Coronary ostium lesion Coronary calcified lesion Intravascular ultrasound Case report
下载PDF
Nickel-disilicide-assisted excimer laser crystallization of amorphous silicon 被引量:1
4
作者 廖燕平 邵喜斌 +5 位作者 郜峰利 骆文生 吴渊 付国柱 荆海 马凯 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第6期1310-1314,共5页
Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step cons... Polycrystalline silicon (poly-Si) thin film has been prepared by means of nickel-disilicide (NiSi2) assisted excimer laser crystallization (ELC). The process to prepare a sample includes two steps. One step consists of the formation of NiSi2 precipitates by heat-treating the dehydrogenated amorphous silicon (a-Si) coated with a thin layer of Ni. And the other step consists of the formation of poly-Si grains by means of ELC. According to the test results of scanning electron microscopy (SEM), another grain growth model named two-interface grain growth has been proposed to contrast with the conventional Ni-metal-induced lateral crystallization (Ni-MILC) model and the ELC model. That is, an additional grain growth interface other than that in conventional ELC is formed, which consists of NiSi2 precipitates and a-Si. The processes for grain growth according to various excimer laser energy densities delivered to the a-Si film have been discussed. It is discovered that grains with needle shape and most of a uniform orientation are formed which grow up with NiSi2 precipitates as seeds. The reason for the formation of such grains which are different from that of Ni-MILC without migration of Ni atoms is not clear. Our model and analysis point out a method to prepare grains with needle shape and mostly of a uniform orientation. If such grains are utilized to make thin-film transistor, its characteristics may be improved. 展开更多
关键词 polycrystalline silicon excimer laser crystallization Ni-disilicide Ni-metal-induced lateral crystallization two-interface grain growth
下载PDF
Understanding the effects of excimer laser treatment on corrosion behavior of biodegradable Mg-1Ca alloy in simulated body fluid 被引量:1
5
作者 Yuxiang Liu Michele Curioni +1 位作者 Shiyun Dong Zhu Liu 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第4期1004-1023,共20页
In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SB... In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SBF)solution using immersion tests and electrochemical impedance spectroscopy(EIS).A 5μm melted layer with a homogeneous microstructure and an MgO film on the surface were achieved by laser radiation.Corrosion observations(hydrogen evolution,morphology and corrosion products)and EIS results revealed an improvement of corrosion resistance after laser treatment for 48 h.It was found a two-layer structure developed after 2 h immersion on both the untreated and laser-treated alloys,but the sequence of forming the two layers was opposite and greatly influenced by the laser-treated layer.The time-evolution corrosion processes on the untreated and laser-treated alloys were discussed,providing a better understanding of corrosion behavior of biodegradable Mg alloys modified by excimer laser. 展开更多
关键词 MAGNESIUM Biodegradable implant excimer laser Simulated body fluid Corrosion EIS
下载PDF
Phosphorus diffusion and activation in fluorine co-implanted germanium after excimer laser annealing
6
作者 Chen Wang Wei-Hang Fan +4 位作者 Yi-Hong Xu Yu-Chao Zhang Hui-Chen Fan Cheng Li Song-Yan Cheng 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期619-623,共5页
The diffusion and the activation of phosphorus in phosphorus and fluorine co-implanted Ge after being annealed by excimer laser are investigated.The results prove that the fluorine element plays an important role in s... The diffusion and the activation of phosphorus in phosphorus and fluorine co-implanted Ge after being annealed by excimer laser are investigated.The results prove that the fluorine element plays an important role in suppressing phosphorus diffusion and enhancing phosphorus activation.Moreover,the rapid thermal annealing process is utilized to evaluate and verify the role of fluorine element.During the initial annealing of co-implanted Ge,it is easier to form high bonding energy FnVm clusters which can stabilize the excess vacancies,resulting in the reduced vacancy-assisted diffusion of phosphorus.The maximum activation concentration of about 4.4 ×10^(20) cm^(-3) with a reduced diffusion length and dopant loss is achieved in co-implanted Ge that is annealed at a tailored laser fluence of 175 mJ/cm^(2).The combination of excimer laser annealing and co-implantation technique provides a reference and guideline for high level n-type doping in Ge and is beneficial to its applications in the scaled Ge MOSFET technology and other devices. 展开更多
关键词 phosphorus diffusion activation concentration co-implanted fluorine GERMANIUM excimer laser annealing
下载PDF
Effect of open ultraviolet germicidal irradiation lamps on functionality of excimer lasers used in cornea surgery
7
作者 Jaroslavas Belovickis Aliaksei Kurylenka Vadim Murashko 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1474-1476,共3页
We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate o... We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate observations of obtained anomalies in post-operative results that are attributed to degradation of reflective optics upon ultraviolet radiation.The presence of direct UVGI coupled with humidity in the operating environment caused merging anomalies and unwanted post-operative correction values.Ultraviolet-A radiation caused a similar effect on the reflective cover of the mirrors. 展开更多
关键词 ultraviolet radiation excimer lasers post-operative anomalies laser-assisted in situ keratomileusis mirror degradation
下载PDF
The Characteristics of the Surface Topography of Excimer Laser Processed Al_2O_3 Ceramic
8
作者 刘莹 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2004年第B10期11-14,共4页
Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statisti... Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statistic parameters of surface topography processed by the excimer laser have an obvious regularity. The arithmetic-mean value R a and the root-mean square value R q change with the changing of processing parameters in the same step and trend, and there is a quantitative relation between them.A simplified model is proposed for the excimer laser processing surface profile, whose results of the analysis and calculation agree basically with the experimental data. Furthermore,the surfaces processed by excimer laser are greatly flat. Skewness root-mean-square value Z· q changed little with the change of the technological parameters. The above characteristics depend on the processing principle of excimer laser, quite different from the cutting processing. 展开更多
关键词 excimer laser processing surface topography characteristics of topography parameters
下载PDF
Surface Modification of Ceramic Materials Using Excimer Laser
9
作者 Yingna WU, Zhongchao FENG and Jing LIANG (Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110015, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第4期401-404,共4页
Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples ex... Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples exhibit a smooth rapid melt layer on the surface, and the formation of the metastabfe γ-Al2Oa was observed. A silicon-rich layer on the surface was formed after laser irradiation of Si3N4. The toughness K1c of the materials was measured by the indentation fracture method. After laser irradiation, the toughness of Al2O3, Al2O3-SiC nanocomposite and Si3N4 was improved to various degrees: Al2O3-SiC nanocomposite, 60% (max.); AI203, 40% (max.); Si3N4, 12% (max.). 展开更多
关键词 Surface Modification of Ceramic Materials Using excimer laser SIC
下载PDF
Ceramics Surface Modification by Excimer Laser Metal Coating
10
作者 Weidou ZHU and Haicheng GU(Dept. of Materials Science and Engineering, Xi’an Jiaotong University, Xi’an, 710049, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1994年第6期463-465,共3页
Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy densi... Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy density was varied from 0.21 to 0.81 J / cm2 to optimize bending strength. For ZrO2 ceramic, it was found that the strength increases from 530 to 753 MPa at 0.51 J / cm2 irradiation. For Al2O3 and (Ce-TZP)+ Al2O3 the fracture strength also increases in varying degree. The causes of strength increment were discussed. 展开更多
关键词 Ceramics Surface Modification by excimer laser Metal Coating RES
下载PDF
A HISTOPATHOLOGIC IMMUNOHISTOCHEMICAL AND ULTRASTRUCTURAL STUDY OF RABBIT CORNEA AFTER EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY
11
作者 张华 胡海涛 +5 位作者 任惠民 刘勇 郭绒霞 孙乃学 王峰 孙健 《Academic Journal of Xi'an Jiaotong University》 2001年第1期-,共5页
Objective To evaluate the corneal healing of non-epuality diopter response histopathologically, immunohistochemically and ultrastructurally after excimer laser photorefractive keratectomy(PRK) with SVS APEX PLUS(Summi... Objective To evaluate the corneal healing of non-epuality diopter response histopathologically, immunohistochemically and ultrastructurally after excimer laser photorefractive keratectomy(PRK) with SVS APEX PLUS(Summit Technology Inc. USA) excimer laser, and the effects of corticosteroid on the healing. Methods PRK on 6 white rabbits(12 eyes) was performed on right eye or the rabbit for an attampted correction or -4.00 diopter and on left eye for an attempted correction of -8.00 diopter. The rabbits were divided into 2 groups randomly and each group included 6 eyes: Group FLM (3 rabbits, 6 eyes) and group CM (3 rabbits, 6 eyes). Fluoromethalone was given to group FLM,and chloromycetin to group CM. On 10d, 30d and 100d,the eyes of one rabbit in each group were enucleated randomly. Half of each cornea was prepared for electron microscope observation (SEM and TEM) and the rest embedded in OCT compound for immunohistochemical study to examine Ⅲ-C and FN. Results All eyes were reepithelialized within 3d after PRK. Subepithelial corneal haze was observed on 15d,which was dominant on 30 or 60d. On 100d postoperatively,corneal hazes of 11 eyes were grades 0 or 0.5,only 1 eye(the left eye or group CM) was denser haze (grade 1). On 3d postoperatively, one or two layers of corneal epithelial cell covered the ablation zone. On 30d after PRK,the epithelial cells showed hyperplastic changes. The cells were larger and increased from normal 5 or 6 layers to 7 or 8 layers of cells on l00d after PRK,epithelium was clear with more bright epithelium. Mi- croplicae and microvilli were less than before. The expression of Ⅲ-C and FN in group CM was significantly more evi- dent than that in group FLM. Conclusion The study show that despite recovery of a continuous and smooth epithelial layer and nearly normal corneal tissues on 100d after PRK,abnormalities of both epithelium and superficial stroma can be detected in the area of ablation. The ablation depth of stroma can influence the appearance of corneal haze af- ter PRK. The microplicae and microvilli of rabbit cornea epithelium become less after PRK,which can be one of cause leading to ocular dry sensation in some patients. 展开更多
关键词 excimer laser photorefractive keratectomy(PRK) CORNEA RABBIT wound healing type collagen (Ⅲ-C) fibronection (FN)
下载PDF
EXCIMER LASER ABLATING OF LIQUID CRYSTAL POLYMER
12
作者 梅胜敏 左敦稳 余大民 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1998年第2期72-77,共6页
Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 24... Ablation experiments of A950 Liquid Crystal Polymer (LCP), as a kind of typical matrix of fibre reinforced polymer composites, are carried out in this paper. Data on the ablation of A950 LCP by excimer laser at 248 nm are presented. The experimental results show that the ablation depth is a linear function of the number of pulse at constant laser fluence, The ablation rate varies with the logorithm of the fluence in a linear manner at different fluences. A satisfactory linear relationship is found between ablation energy and incident fluence. Perhaps due to the plume absorption and thermal effect, the ablation rate varies complicatedly with pulse repetition frequency. 展开更多
关键词 laser processing ablation POLYMER excimer laser
下载PDF
Long-term efficacy of excimer laser in situ keratomileusis in the management of children with high anisometropic amblyopia 被引量:9
13
作者 LIN Xiao-ming YAN Xiao-he WANG Zheng YANG Bin CHEN Qi-wen SU Jin-ai YE Xue-lian 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第7期813-817,共5页
Background Children with anisometropic amblyopia are often noncompliant with traditional treatment including spectacules and contact lenses. This study was to evaluate the long-term efficacy of excimer laser in situ k... Background Children with anisometropic amblyopia are often noncompliant with traditional treatment including spectacules and contact lenses. This study was to evaluate the long-term efficacy of excimer laser in situ keratomileusis (LASIK) for children with high anisometropic amblyopia. Methods A retrospective analysis of 24 children with high unilateral anisometropic amblyopia, who underwent LASIK during the period between August 2000 and September 2005 in our hospital, was conducted. The mean age of these children was (7.4±1.9) years (range 5-14 years) and the mean follow-up period was (33.3±14.2) months (range 18.5-74.2 months). After LASIK, visual acuity, refraction and far or near stereoacuity were analyzed. Near stereoacuity was measured by the random-dot butterfly stereogram and the pre-school random-dot stereogram, while far stereoacuity was measured by the synoptophore with Yan's random-dot stereogram. Results Mean preoperative uncorrected visual acuity was 0.06±0.05, while mean postoperative uncorrected visual acuity was elevated to 0.43±0.33. Mean preoperative best-corrected visual acuity was 0.26±0.22, while mean postoperative best-corrected visual acuity was elevated to 0.67±0.40. For patients with myopic anisometropia, preoperative mean spherical equivalent refraction was (-8.01±2.70) D while postoperative value significantly reduced to (-1.32±2.47) D. For patients with hyperopic anisometropia, preoperative mean spherical equivalent refraction was ( 7.35±1.55) D while postoperative value significantly reduced to (3.30±0.86) D. These results demonstrated that there was statistical difference in these parameters between preoperative and postoperative tests. At the last follow-up, 20 patients had near stereoacuity, and the mean near stereoacuities measured by the random-dot butterfly stereogram and the preschool random-dot stereogram were (149.00±152.93)" and (201.05±235.94)", respectively. In contrast, 11 patients had far stereoacuity, and the mean far stereoacuity measured by the synoptophore was (210.91±217.51). Three cases of patients developed mild corneal complications. Conclusion LASIK for the correction of high anisometropia in children with monocular amblyopia may be safe and effective, and this can help effectively conduct postoperative amblyopia training and improve the cure rate. 展开更多
关键词 excimer laser in situ keratomileusis AMBLYOPIA CHILDREN ANISOMETROPIA
原文传递
KrF excimer laser-fabricated Bragg grating in optical microfiber made from pre-etched conventional photosensitive fiber 被引量:2
14
作者 卫正统 姜暖 +2 位作者 宋章启 张学亮 孟洲 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第4期12-15,共4页
A method to fabricate fiber Bragg grating (FBG) in an optical microfiber (OM) from a conventional photosensitive fiber is proposed in this letter. The cladding of a conventional photosensitive fiber is etched to 1... A method to fabricate fiber Bragg grating (FBG) in an optical microfiber (OM) from a conventional photosensitive fiber is proposed in this letter. The cladding of a conventional photosensitive fiber is etched to 17 pro. The etched fiber is drawn to an OM 6μm in diameter. The photosensitivity of the fabricated OM is effectively reserved. A FBG in the OM (MFBG) is successfully fabricated using a KrF excimer laser at a fluence of 400 mJ/cm2 through a phase mask with a pitch of 1 089.3 nm. The reflectivity of the FBG is approximately 10%, and the 3-dB spectrum bandwidth is 0.13 nm. The concentration of brine is measured by immersing the MFBG in the liquid, and the minimum detectable refractive index variation can reach 7.2×10^-5 at a refractive index value of 1.33. 展开更多
关键词 excimer lasers Fabrication Fiber Bragg gratings Light sensitive materials PHOTOSENSITIVITY Refractive index
原文传递
Corrosion behaviors of the copper alloy electrodes in Ar F excimer laser operation process 被引量:1
15
作者 Xin Guo Jinbin Ding +1 位作者 Yi Zhou Yu Wang 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2018年第1期51-57,共7页
The corrosion behaviors of the Ar F excimer laser copper alloy electrodes were studied. The morphology, composition and impurities were characterized by optical microscope, scanning electron microscopy, electron micro... The corrosion behaviors of the Ar F excimer laser copper alloy electrodes were studied. The morphology, composition and impurities were characterized by optical microscope, scanning electron microscopy, electron microprobe and glow discharge mass spectrometer methods. The anode produces the reef, the corrosion pits, the hole layer and the 1–10 μm level flake impurity. The cathode produces the particles, the sputtering pits, the element reduce layer and the 1 μm level particle impurity. Besides the Cu element, other elements in the alloy participate in the corrosion: Al element in the reef is over 1.5 times of the anode, Zn element in the particles is 1.3 times of the cathode, many trace elements congregate on the copper surface several and even hundreds of times. These elements are responsible to a great degree for the impurities and the rapid energy decline of the long-time idled laser. 展开更多
关键词 Ar F excimer laser corrosion behavior electrode IMPURITY trace element
原文传递
Excimer laser 6^(th)generation:state of the art and refractive surgical outcomes 被引量:1
16
作者 Mohamed El Bahrawy Jorge L Alió 《Eye and Vision》 SCIE 2015年第1期44-52,共9页
After nearly three decades of innovation in excimer laser,today we are presented with a state of the art generation targeting minimally invasive refractive surgery with high speed laser,faster trackers,pupil monitorin... After nearly three decades of innovation in excimer laser,today we are presented with a state of the art generation targeting minimally invasive refractive surgery with high speed laser,faster trackers,pupil monitoring systems and better customization profiles.These systems are capable of delivering better treatments with less induced postoperative high order aberrations.The results reported by many authors had confirmed the superiority in efficiency and safety profiles of this generation compared to previous generations.Still,current technology is facing major challenges in the correction of high hyperopic errors and in presbyopic treatments,with upgrades in ablation centration and thermal control needed,which will ensure better biomechanical results,as a step closer to perfection in refractive surgery. 展开更多
关键词 Refractive surgery excimer laser 6^(th)Generation
原文传递
CLINICAL ANALYSIS OF EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY FOR TREATMENT OF MYOPIA AND MYOPIC ASTIGMATISM 被引量:1
17
作者 张华 郭绒霞 +5 位作者 孙乃学 王峰 张道过 王彤 孙健 杨振国 《Journal of Pharmaceutical Analysis》 CAS 1999年第1期54-61,共8页
To evaluate the efficacy and accuracy of photorefractive keratectomy (PRK) for myopia and myopic astigmatism .SVS APEX excimer laser with a wave length of 193 nm(Sumit Technology Inc. Waltham, Mass, USA) was applied. ... To evaluate the efficacy and accuracy of photorefractive keratectomy (PRK) for myopia and myopic astigmatism .SVS APEX excimer laser with a wave length of 193 nm(Sumit Technology Inc. Waltham, Mass, USA) was applied. 316 myopic eyes of 168 patients were treated with PRK between September, 1996 and October, 1997, and 260 eyes (84%) of 150 patients were followed for more than three months, including male 68(116 eyes, 401%) and female 82(144 eyes, 599%). The preoperative spherical equivalent refractive errors ranged from -125D to -1000 (mean -467163D), and astigmatism ranged from 0 to -200D (means -033045D). We divided the patients into two groups according to the referaction: group A (from -125D to -590D) and group B(from -600 to -1000D). The number of eyes in the two groups were 220 and 40 respectively. In group A, on the 10th day, 689% has the uncorrected visual acuity (UCVA) equal to or one line better or lower than the preoperative best corrected visual acuity (BCVA). In 1,3,6 and 12 months, 90 %, 96%, 95% and 94% had the UCVA equal to or one line better or lower than the preoperative BCVA respectively. In group B, on the 10 th day, in 1,3,6 and 12 months, UCVA equal to or one line better or lower than the preoperative BCVA occurred in 359%, 83%, 87%, 86%, and 84% of the cases respectively. Most of the haze showed 051 grades except 3 eyes with the haze of 2 grade in 3 or 6 months and it changed to 1 and 05 grade respectively within one year. In 10 days and 1,3,6,12 months postoperatively, the corneal haze was noted in 329%, 848%, 628%,90% and 28% of the treated eyes respectively. We found that 193 nm excimer laser PRK was a predictable, safe, stable, and effective refractive surgery for correcting myopia up to -1000D in Chinese patients, and the effect was better in myopia lower than -600D. 展开更多
关键词 excimer laser photorefractive keratectomy MYOPIA myopic astigmatism
下载PDF
The Computer Analysis of the Excimer Laser Beam Intensity Uniformization by Rotational Lens Array
18
作者 Xu Huabin Chen Lin Chen Baoxue The Physics Department of Shanghai Second Polytechnic University, China,E-mail:hbhbxu@sina.com College of Optic and Electron Information Engineering, University of Shanghai for Science and Technology 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期869-870,共2页
The excimer laser has important applications in many fields. Because of its non-uniform intensity distribution there are some limits in applications. This paper introduces rotational lens array to improve intensity di... The excimer laser has important applications in many fields. Because of its non-uniform intensity distribution there are some limits in applications. This paper introduces rotational lens array to improve intensity distributions. The intensity variation is reduced to 1 percent by computer simulation. 展开更多
关键词 of on by The Computer Analysis of the excimer laser Beam Intensity Uniformization by Rotational Lens Array HAVE for
原文传递
Current review of Excimer laser Trabeculostomy
19
作者 Georges M.Durr Marc Töteberg-Harms +3 位作者 Richard Lewis Antonio Fea Paola Marolo Iqbal Ike K.Ahmed 《Eye and Vision》 SCIE CSCD 2020年第1期232-240,共9页
Background:Excimer laser trabeculostomy(ELT)is a microinvasive glaucoma surgery(MIGS)that creates multiple laser channels through the trabecular meshwork using a cold laser system,which minimizes tissue fibrosis and a... Background:Excimer laser trabeculostomy(ELT)is a microinvasive glaucoma surgery(MIGS)that creates multiple laser channels through the trabecular meshwork using a cold laser system,which minimizes tissue fibrosis and aids in bypassing the main area of resistance to aqueous outflow.The purpose of this review is to evaluate the current body of evidence surrounding ELT in terms of efficacy and review the safety profile of the procedure.Main text:Studies screened had to show clear inclusion and exclusion criteria as well as well-defined outcome measures.PubMed,MEDLINE,EMBASE and the Cochrane Controlled Trial Database were searched.Preferred Reporting Items of Systematic Reviews(PRISMA)guidelines were used to assess for study quality and for any bias.Sixty-four articles were initially identified with 18 meeting preliminary screening criteria.Ultimately,8 studies met inclusion criteria and 2 additional non-referenced publications were also included:1 randomized control trial,4 prospective case series and 5 retrospective studies.Overall studies showed moderate intraocular pressure(IOP)lowering of between 20%and 40%from baseline without medication washout and mostly a decrease in glaucoma medications with few complications.Conclusion:Current literature shows a significant IOP-lowering effect of ELT with a favorable safety-profile in standalone cases or combined with cataract surgery.Limitations to these studies are the lack of controls and washout IOP.Overall,ELT is an attractive MIGS option that does not require any residual device remaining in the angle. 展开更多
关键词 excimer laser trabeculostomy TRABECULOTOMY ELT Intraocular pressure GLAUCOMA MIGS CATARACT
原文传递
Effects of prism beam expander and slits on excimer laser linewidth narrowing module
20
作者 张海波 袁志军 +2 位作者 周军 魏运荣 楼祺洪 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第4期37-40,共4页
Theoretical simulation and experiments based on a prism beam expander and an echelle grating are con- ducted to study the dependence of linewidth and pulse energy on incidence angle and slit width. With a larger prism... Theoretical simulation and experiments based on a prism beam expander and an echelle grating are con- ducted to study the dependence of linewidth and pulse energy on incidence angle and slit width. With a larger prism incident angle or narrower slit width, the linewidth becomes narrower while the laser pulse energy becomes lower. However, the pulse energy can be improved by optimally designing the prism beam expander. In addition, a subpicometer linewidth ArF laser is obtained with a double-prism beam expander and an echelle grating. 展开更多
关键词 Diffraction gratings excimer lasers LINEWIDTH
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部