期刊文献+
共找到194篇文章
< 1 2 10 >
每页显示 20 50 100
Changes in ocular surface status and dry eye symptoms following femtosecond laser-assisted cataract surgery 被引量:4
1
作者 Rui-Hong Ju Yun Chen +4 位作者 Hai-Song Chen Wei-Jian Zhou Wei Yang Zhen-De Lin Zhe-Ming Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第7期1122-1126,共5页
AIM: To observe the changes in ocular surface and the dry eye symptoms following femtosecond laser-assisted cataract surgery(FLACS). METHODS: Patients with no eye signs or symptoms in Guangzhou Aier Eye Hospital betwe... AIM: To observe the changes in ocular surface and the dry eye symptoms following femtosecond laser-assisted cataract surgery(FLACS). METHODS: Patients with no eye signs or symptoms in Guangzhou Aier Eye Hospital between October 2017 and September 2018, who underwent FLACS and intraocular lens(IOL) implantation for age-related cataract were enrolled. Tear film stability assessed with OCULUS Keratograph 5 M, Schirmer’s I test(SIT), and corneal fluorescein staining(CFS) were evaluated before and after surgery at 1 d, 1 wk, 1, and 3 mo in order. Ocular Surface Disease Index scores(OSDI) and Subjective Symptom Questionnaires(SSQs) were recorded at the same time point.RESULTS: Thirty-eight eyes of 38 patients were enrolled. The noninvasive tear film break-up time(first break-up time and average break-up time) decreased in a peak at the 1 wk visit, and then increased to basic levels at 1 mo. The tear meniscus height(TMH) increased transiently at 1 d, and declined in the following 3 mo visits. The SIT had a transient increase at 1 d(P=0.357) and a decrease at 1 wk and 1 mo(both P<0.05) but returned to the preoperative levels at 3 mo after surgery(P=0.062). CFS scores were significantly improved compared with those before surgery, and had a statistical difference(P<0.05). OSDI scores and SSQs after surgery were obviously higher, and had a statistical difference(P<0.001) but didn’t return to the basic level by 3 mo. CONCLUSION: Dry eye signs and symptoms can occur immediately following FLACS and have a peak severity on day 7 postoperatively. Most signs of dry eye can return to preoperative basic levels within 3 mo postoperatively. However, all cases can not recover from CFS and dry eye symptoms at 3 mo postoperatively. 展开更多
关键词 OCULAR surface dry eye TEAR film femtosecond laser-assisted CATARACT surgery
下载PDF
The Characteristics of the Surface Topography of Excimer Laser Processed Al_2O_3 Ceramic
2
作者 刘莹 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2004年第B10期11-14,共4页
Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statisti... Surface of Al 2O 3 ceramic was processed by an excimer laser and the characteristics of topography were examined based on the application of the microelectromechanical system(MEMS). It is indicated that the statistic parameters of surface topography processed by the excimer laser have an obvious regularity. The arithmetic-mean value R a and the root-mean square value R q change with the changing of processing parameters in the same step and trend, and there is a quantitative relation between them.A simplified model is proposed for the excimer laser processing surface profile, whose results of the analysis and calculation agree basically with the experimental data. Furthermore,the surfaces processed by excimer laser are greatly flat. Skewness root-mean-square value Z· q changed little with the change of the technological parameters. The above characteristics depend on the processing principle of excimer laser, quite different from the cutting processing. 展开更多
关键词 excimer laser processing surface topography characteristics of topography parameters
下载PDF
Surface Modification of Ceramic Materials Using Excimer Laser
3
作者 Yingna WU, Zhongchao FENG and Jing LIANG (Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110015, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第4期401-404,共4页
Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples ex... Changes of surface morphology following XeCI excimer laser irradiation were investigated for three engineering ceramic materials (Al2O3, Al2O3-SiC nanocomposite and Si3N4). Al2O3 and AI2O3-SiC nanocomposite samples exhibit a smooth rapid melt layer on the surface, and the formation of the metastabfe γ-Al2Oa was observed. A silicon-rich layer on the surface was formed after laser irradiation of Si3N4. The toughness K1c of the materials was measured by the indentation fracture method. After laser irradiation, the toughness of Al2O3, Al2O3-SiC nanocomposite and Si3N4 was improved to various degrees: Al2O3-SiC nanocomposite, 60% (max.); AI203, 40% (max.); Si3N4, 12% (max.). 展开更多
关键词 surface Modification of Ceramic Materials Using excimer laser SIC
下载PDF
Ceramics Surface Modification by Excimer Laser Metal Coating
4
作者 Weidou ZHU and Haicheng GU(Dept. of Materials Science and Engineering, Xi’an Jiaotong University, Xi’an, 710049, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1994年第6期463-465,共3页
Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy densi... Thin metallic layers (~ 2 μm) of Ni were deposited on polycrystalline Al2O3. ZrO2 and (Ce-TZP)+Al2O3 ceramic substrates. and further irradiated with pulsed excimer (Xeno chloride) laser pulses. The laser energy density was varied from 0.21 to 0.81 J / cm2 to optimize bending strength. For ZrO2 ceramic, it was found that the strength increases from 530 to 753 MPa at 0.51 J / cm2 irradiation. For Al2O3 and (Ce-TZP)+ Al2O3 the fracture strength also increases in varying degree. The causes of strength increment were discussed. 展开更多
关键词 Ceramics surface Modification by excimer laser Metal Coating RES
下载PDF
激光类手术矫正老视的新进展
5
作者 刘晓鹏 雷玉琳 《国际眼科杂志》 CAS 2024年第11期1753-1758,共6页
随着全球老龄化的加剧,老视逐渐成为一个全球性的问题,老视矫正手术在近些年不断涌现。激光技术的应用为屈光手术带来了极大的便利,同样其在老视的矫正中也发挥着越来越重要的作用,准分子激光和飞秒激光技术的出现,打开了老视手术治疗... 随着全球老龄化的加剧,老视逐渐成为一个全球性的问题,老视矫正手术在近些年不断涌现。激光技术的应用为屈光手术带来了极大的便利,同样其在老视的矫正中也发挥着越来越重要的作用,准分子激光和飞秒激光技术的出现,打开了老视手术治疗的新世界,为老视手术矫正带来了新的希望。文章主要就准分子激光和飞秒激光技术在老视手术中的应用以及新进展展开叙述。 展开更多
关键词 老视 角膜手术 激光 准分子 飞秒 进展
下载PDF
准分子激光角膜屈光手术前病人抑郁、焦虑影响因素分析
6
作者 姜华敏 杨彦平 《循证护理》 2024年第11期2064-2069,共6页
目的:探讨准分子激光角膜屈光手术前病人抑郁、焦虑影响因素及分析干预对策。方法:采用便利抽样法,选取2020年1月—12月在本院行准分子激光角膜屈光手术的110例(220眼)近视病人作为研究对象。通过问卷调查的方式,收集研究对象基本资料... 目的:探讨准分子激光角膜屈光手术前病人抑郁、焦虑影响因素及分析干预对策。方法:采用便利抽样法,选取2020年1月—12月在本院行准分子激光角膜屈光手术的110例(220眼)近视病人作为研究对象。通过问卷调查的方式,收集研究对象基本资料及抑郁、焦虑现状,并采用单因素和多元线性回归分析影响准分子激光角膜屈光手术前病人抑郁、焦虑情绪的相关因素。结果:110例病人的术前抑郁情绪均分(44.73±8.56)分,术前焦虑情绪均分(40.91±6.72)分;其中19例(17.27%)病人存在明显抑郁情绪,10例(9.06%)病人存在明显焦虑情绪,抑郁、焦虑发生率为26.36%(29例)。多元线性回归方程分析结果显示,性别、近视程度、术前视觉质量、眼表疾病指数(OSDI)是影响准分子激光角膜屈光手术前病人抑郁情绪的独立危险因素(P<0.05);性别、术前视觉质量、OSDI、相关知识掌握程度、知识获取渠道是影响准分子激光角膜屈光手术前病人焦虑情绪的独立危险因素(P<0.05)。结论:本研究中准分子激光角膜屈光手术前病人存在抑郁、焦虑倾向。建议临床工作中应加强与病人的沟通交流与术前评估,根据病人的实际情况,结合相关危险因素,给予针对性护理干预措施,从而改善病人的抑郁、焦虑情绪。 展开更多
关键词 准分子激光角膜屈光手术 抑郁 焦虑 影响因素 护理
下载PDF
Study on the Corneal Higher-Order Aberrations and Correlation in Patients with Different Degrees of Myopia Suitable for Wavefront-Guided FS-LASIK 被引量:1
7
作者 Chengzhe Wu Xun Cui +4 位作者 Zhengri Li Hong Cui Lixia Sun Haiyan Jin Yingjun Li 《Journal of Biosciences and Medicines》 2020年第1期13-22,共10页
Background: Individualized corneal refractive surgery requires an understanding of the basis of higher-order aberrations before surgery. To investigate the characteristics and distribution of anterior surface wavefron... Background: Individualized corneal refractive surgery requires an understanding of the basis of higher-order aberrations before surgery. To investigate the characteristics and distribution of anterior surface wavefront aberrations in patients suitable for corneal refractive surgery. Methods: A total of 121 myopic patients (121 eyes, 18 - 45 years old) who underwent corneal refractive surgery were recruited from January to May 2016 at Affiliated Hospital, Yanbian University. Patients were randomly selected by the Pentacam anterior segment analysis system with a spherical equivalent (SE) of -0.25 to -10.00 D. The corneal anterior aberrations (total higher-order aberration;spherical aberration;Coma;Trefoil) and Q and K values were detected, and a correlation analysis of the relevant parameters was carried out. Results: The root-mean-square (RMS) of the third to sixth order aberrations of the corneal anterior wavefront aberrations at a 6 mm analysis diameter showed a decreasing trend in patients suitable for the corneal refractive surgery, and the RMS of the third order aberrations accounted for 62.92% of the total HOAs. The coma ratio (coma/total cornea higher-order aberrations) was increased with the increasing diopters, while the spherical aberration ratio (spherical aberration/total cornea higher-order aberrations) was not changed. In addition, the spherical aberration was 0.203 ± 0.082 μm (range: 0.061 to 0.503 μm), and the Q30 was -0.19 ± 0.03 (range: -0.58 to 0.31). There were significant differences in the coma aberrations of preoperative corneal anterior surface (3, 1) between the low, middle and high myopia groups (P = 0.013). The spherical equivalent was positively correlated with the corneal coma of the anterior corneal surfaces (R =?-0.241, P = 0.009), and the Q value was positively correlated with the total higher-order aberrations (R = 0.326, P Conclusions: Individual wavefront aberrations on the anterior surfaces of the cornea are comparatively different, and the Zernike coefficients are related to the degree of myopia. Spherical aberrations are the most overriding aberrations of the cornea. 展开更多
关键词 corneal Refractive surgery ANTERIOR corneal surface Higher-Order ABERRATION Spherical ABERRATION
下载PDF
Periodic surface structures fabricated by one excimer laser pulse through a silica phase mask grating
8
作者 Luo, GP Wu, HM +5 位作者 Wang, M Zhu, SN Lu, YQ Liu, ZG Wei, Y Ming, NB 《Chinese Science Bulletin》 SCIE EI CAS 1997年第21期1787-1792,共6页
RECENTLY, excimer laser devices, which have higher-energy density output in pulsed ultravio-let (UV) light (193 or 248 nm), have been employed to generate some thin film struc-tures. The principle of this technique, w... RECENTLY, excimer laser devices, which have higher-energy density output in pulsed ultravio-let (UV) light (193 or 248 nm), have been employed to generate some thin film struc-tures. The principle of this technique, which is also called pulsed laser deposition (PLD)technique, is that the exposed material could be ablated out of the sample by the focusing laserbeam, and redeposit on a substrate to form thin-film structures under certain conditions. Onthe other hand, researchers have obtained high-quality Bragg gratings in photosensitive 展开更多
关键词 excimer laser pulse phase MASK GRATING PERIODIC surface structures.
原文传递
A recognition survey of granular corneal dystrophy type 2 genetic detection in China
9
作者 Xin-Rui Wang Bi-Ting Zhou +8 位作者 Qing-Mei Zheng Ya-Duan Wang Qiu-Kai Huang Xuan Song He Wang Nan-Wen Zhang Yi-Hua Zhu Xiao-Le Chen Ju-Hua Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第12期1976-1982,共7页
AIM:To evaluate the feasibility of promoting genetic detection for granular corneal dystrophy type 2(GCD2)by a questionnaire conducted among citizens in five cities in China.METHODS:The data were collected by question... AIM:To evaluate the feasibility of promoting genetic detection for granular corneal dystrophy type 2(GCD2)by a questionnaire conducted among citizens in five cities in China.METHODS:The data were collected by questionnaire,and analyzed by Chi-square test and one-tailed t test in IBM SPSS statistics.RESULTS:Based on the survey data on the awareness of GCD2 genetic detection in this study and the positive predictive analysis report of the citizens in five cities in China,the vast majority(84.2%)of respondents had never heard of it and did not know that GCD2 patients have been prohibited from performing excimer surgery that can deteriorate GCD2 patients’condition even leading to blindness.Though 3.4%of patients understood GCD2 very much,they have no idea that GCD2 could not be 100%accuracy diagnosed by the conventional inspection methods.CONCLUSION:It is feasible and necessary to use GCD2 genetic detection as an excimer preoperative examination project.In order to promote the development of detection project,a few improvements should be carried out in terms of the promoting efforts,costs,and research progress. 展开更多
关键词 granular corneal dystrophy type 2 corneal opacity excimer laser surgery
下载PDF
波前像差引导FS-LASIK矫正中高度近视患者术后1年眼前节变化 被引量:1
10
作者 程蕾 朱冉 宋超 《眼科新进展》 CAS 北大核心 2023年第2期142-146,共5页
目的探讨波前像差引导FS-LASIK矫正中高度近视患者术后1年对眼前节结构的影响。方法收集2020年7月至2021年3月在徐州市第一人民医院就诊符合手术适应证且接受波前像差引导FS-LASIK患者共40例78眼的临床资料,分为中度近视组和高度近视组... 目的探讨波前像差引导FS-LASIK矫正中高度近视患者术后1年对眼前节结构的影响。方法收集2020年7月至2021年3月在徐州市第一人民医院就诊符合手术适应证且接受波前像差引导FS-LASIK患者共40例78眼的临床资料,分为中度近视组和高度近视组;分别于术前、术后1个月、术后1年行Pentacam AXL眼前节分析仪测量眼前节,包括角膜后表面Q值,全角膜像差,后表面高阶像差、球差、彗差,角膜后表面曲率、顶点高度及最薄点高度,前房深度(ACD)、前房容积(ACV)和前房角(ACA),并对比分析。结果中度近视组患眼角膜后表面曲率和角膜后表面Q值术前与术后1个月、术后1年相比差异均有统计学意义(均为P<0.05),高度近视组患眼角膜后表面最薄点高度和角膜后表面Q值术前与术后1年相比差异均有统计学意义(均为P<0.05)。中度近视组患眼角膜后表面垂直彗差术前与术后1个月、术后1年相比差异均有统计学意义(均为P<0.05),高度近视组患眼全角膜像差、角膜后表面球差和垂直彗差术前与术后1个月、术后1年相比差异均有统计学意义(均为P<0.05)。中度近视组及高度近视组患眼ACD、ACV术前与术后1个月、术后1年相比差异均有统计学意义(均为P<0.05),ACA术前术后相比差异均无统计学意义(均为P>0.05)。术后1年和术前球差变化值与术前等效球镜度(SE)相关性分析发现,高度近视组患眼球差变化值与术前SE呈中度相关(r=-0.349,P=0.025),而中度近视组患眼球差变化值与术前SE无明显相关性(r=-0.052,P=0.758)。结论波前像差引导FS-LASIK虽然对患者高阶像差有一定改善,但对角膜后表面和前房结构仍然有一定影响,主要集中在中央区,对周边影响相对较小,术后1年眼前节结构相对稳定。 展开更多
关键词 波前像差引导FS-LASIK 角膜后表面高度 角膜后表面Q值 高阶像差 前房深度 前房容积 前房角
下载PDF
增生性糖尿病视网膜病变微创玻璃体手术中角膜保护剂与平衡盐溶液对眼表保护效果对比 被引量:2
11
作者 肖雪冰 肖雪剑 +1 位作者 林婷婷 陈岩岩 《中外医疗》 2023年第1期44-48,共5页
目的研究增生性糖尿病视网膜病变(proliferative diabetic retinopathy,PDR)微创玻璃体手术中角膜保护剂与平衡盐溶液对眼表的保护效果。方法方便选择2020年1月—2021年11月于大庆油田总医院接受微创玻璃体手术治疗的92例PDR患者作为观... 目的研究增生性糖尿病视网膜病变(proliferative diabetic retinopathy,PDR)微创玻璃体手术中角膜保护剂与平衡盐溶液对眼表的保护效果。方法方便选择2020年1月—2021年11月于大庆油田总医院接受微创玻璃体手术治疗的92例PDR患者作为观察对象,采用随机数表法将其分为2组,各46例。对照组微创玻璃体术中滴加平衡盐溶液,研究组术中滴加角膜保护剂。对比两组术前和术后7 d泪膜功能、眼部不适症状及术毕角膜上皮水肿分级。结果与术前相比,术后7 d两组泪膜破裂时间、泪液浸湿长度均更短,术后7 d两组角膜荧光素钠染色评分均更高,差异有统计学意义(P<0.05);术后7 d研究组泪膜破裂时间(5.62±1.60)s、泪液浸湿长度(11.25±2.19)mm/5 min均长于对照组(4.83±1.52)s、(9.87±1.2)mm/5 min,角膜荧光素钠染色评分(5.38±1.06)分低于对照组(6.16±1.23)分,差异有统计学意义(t=2.428、3.436、3.258,P<0.05);与术前相比,术后7 d两组患者OSDI评分均更高,差异有统计学意义(P<0.05);但术后7 d研究组OSDI评分(51.61±7.23)分低于对照组(54.89±7.56)分,差异有统计学意义(t=2.127,P<0.05);研究组患者术毕角膜上皮水肿分级优于对照组,差异有统计学意义(P<0.05)。结论相比于平衡盐溶液,PDR微创玻璃体手术中应用角膜保护剂能有效保护眼表,促进术后眼表组织及泪膜功能恢复,减轻眼部不适症状。 展开更多
关键词 增生性糖尿病视网膜病变 微创玻璃体手术 角膜保护剂 平衡盐溶液 眼表
下载PDF
SMILE及FS-LASIK术对中低度近视的ISV及角膜光密度值的影响 被引量:1
12
作者 张婉君 朱凤 +2 位作者 廖超 冯琴 关虹 《临床眼科杂志》 2023年第2期136-139,共4页
目的探讨全飞秒激光小切口角膜基质透镜取出术(SMILE)和半飞秒激光辅助制瓣-准分子激光原位角膜磨镶(FS-LASIK)术对中低度近视患者的的角膜表面变异指数(ISV)及角膜光密度值的影响。方法回顾性病例对照研究。选取合肥普瑞眼科医院2021年... 目的探讨全飞秒激光小切口角膜基质透镜取出术(SMILE)和半飞秒激光辅助制瓣-准分子激光原位角膜磨镶(FS-LASIK)术对中低度近视患者的的角膜表面变异指数(ISV)及角膜光密度值的影响。方法回顾性病例对照研究。选取合肥普瑞眼科医院2021年6月至2022年6月间收治的中低度近视患者作为研究对象,按照手术方式将其分为SMILE组和FS-LASIK组,每组各40例。分别于术前、术后1周及术后1个月,分析比较两组患者的裸眼视力、最佳矫正视力、ISV和整体角膜光密度值。结果术前,两组患者的裸眼视力、最佳矫正视力、ISV和整体角膜光密度值相比无显著差异(P>0.05)。术后1个月,两组患者的裸眼视力均高于同组其他时段(P<0.05),且FS-LASIK组高于SMILE组(P>0.05);两组患者的最佳矫正视力均优于同组其他时段(P<0.05),但组间比较无显著差异(P>0.05)。术后1个月,两组患者的ISV均高于同组其他时段(P<0.05),且FS-LASIK组高于SMILE组(P<0.05);两组患者的整体角膜光密度均低于同组其他时段(P<0.05),但组间无显著差异(P>0.05)。结论SMILE和FS-LASIK术式对于中低度近视的患者均有着良好的疗效,且两种术式对患者角膜光密度的影响较为一致,但SMILE较FS-LASIK对患者ISV影响更小。 展开更多
关键词 近视 全飞秒激光小切口角膜基质透镜取出术 矫正手术 角膜表面规则指数 角膜光密度
下载PDF
飞秒激光与常规刀片准分子激光术后角膜后表面高度早期变化的对照研究 被引量:17
13
作者 薛超 王雁 +6 位作者 左彤 耿维莉 金颖 张琳 李晶 谢丽丽 李智敏 《中华实验眼科杂志》 CAS CSCD 北大核心 2014年第3期235-240,共6页
背景 飞秒激光准分子激光角膜原位磨镶术(FS-LASIK)已广泛用于屈光不正的矫治,具有良好的安全性和可预测性,但缺乏术后角膜后表面高度动态变化的研究.了解FS-LASIK术后角膜后表面高度的动态变化对于预防医源性角膜膨隆具有重要意义. ... 背景 飞秒激光准分子激光角膜原位磨镶术(FS-LASIK)已广泛用于屈光不正的矫治,具有良好的安全性和可预测性,但缺乏术后角膜后表面高度动态变化的研究.了解FS-LASIK术后角膜后表面高度的动态变化对于预防医源性角膜膨隆具有重要意义. 目的 分析FS-LASIK术后早期角膜后表面高度的变化情况,并与前弹力层下准分子激光角膜磨镶术(SBK)、上皮刀辅助的准分子激光上皮瓣下角膜磨镶术(Epi-LASIK)术后情况进行比较.方法 采用前瞻性非随机对照研究设计.纳入2010年6-9月在天津市眼科医院行准分子激光角膜屈光手术的近视及近视散光患者72例144眼,分为FS-LASIK组23例46眼,SBK组28例56眼,Epi-LASIK组21例42眼.分别于术前及术后1d(Epi-LASIK组术后3d)、1周、1个月用Visante OMNI测量术眼角膜后表面水平子午线和垂直子午线上角膜顶点及距离角膜顶点1、2、3 mm共13个点的角膜后表面高度,采用重复测量的方差分析进行统计学分析. 结果 在FS-LASIK组,术前、术后1d、1周、1个月术眼角膜顶点方位角膜后表面高度分别为(2.03±0.78)、(2.26±0.96)、(2.16±0.85)和(2.06±0.89)μm;在距角膜顶点1 mm、2 mm区域,术眼的术后变化趋势与角膜顶点区域的变化相同;在距角膜顶点3 mm区域,上述4个时间点术眼的角膜后表面高度分别为(-4.64±1.68)、(-5.39±1.85)、(-4.73±1.71)和(-4.71±1.52) μm.在SBK组,术前及术后1d、1周、1个月角膜顶点区域角膜后表面高度分别为(1.44±0.63)、(1.74±0.75)、(1.66±0.69)和(1.53±0.71) μm;在距角膜顶点1 mm、2 mm区域,术眼术后角膜后表面高度变化趋势与角膜顶点区域一致;在距角膜顶点3 mm区域,上述4个时间点角膜后表面高度分别为(-5.09±1.76)、(-5.48±1.68)、(-5.27±1.81)和(-5.19±1.77)μm,术后发生了轻微后移.在Epi-LASIK组,术前,术后3d、1周、1个月在角膜顶点区角膜后表面高度分别为(2.47±0.73)、(1.55±1.43)、(1.55±1.37)和(2.37±1.06) μm,术后发生轻微后移;而在距角膜顶点1 mm、2 mm区域则与角膜顶点术后变化趋势不同,术后3d角膜后表面高度分别由术前的(1.55±0.51)μm、(-1.87±0.91)μm变为(1.92±0.91) μm、(0.24±1.35) μm,角膜发生轻微前移.在距角膜顶点3 mm区域,角膜后表面高度变化趋势与角膜顶点区相同.FS-LASIK组和SBK组术眼术后角膜后表面高度的变化较小,Epi-LASIK术后1d、1周时较术前变化较大.术后1d时,FS-LASIK相对于SBK变化较大.不同的手术方式及不同时间点角膜后表面高度的差异均无统计学意义(P>0.05).结论 FS-LASIK术后早期中央区和旁中央区的角膜后表面高度发生了微小的变化,但随时间的变化逐渐恢复至术前水平,与SBK、Epi-LASIK相比无明显差异. 展开更多
关键词 准分子激光屈光性角膜手术 角膜 后表面 近视
下载PDF
不同程度近视和散光患者行飞秒激光小切口角膜基质透镜取出术的早期临床疗效评估 被引量:28
14
作者 赵伟 王雁 +4 位作者 李华 窦瑞 张佳媚 李浏洋 危平辉 《中华实验眼科杂志》 CAS CSCD 北大核心 2017年第4期349-354,共6页
背景飞秒激光小切口角膜基质透镜取出术(SMILE)已广泛用于屈光不正的矫正,但是关于SMILE对不同程度屈光不正,尤其对不同程度近视及散光矫正后的早期临床效果评估研究较少。目的探讨和比较SMILE矫正低、中、高度近视的安全性、有效... 背景飞秒激光小切口角膜基质透镜取出术(SMILE)已广泛用于屈光不正的矫正,但是关于SMILE对不同程度屈光不正,尤其对不同程度近视及散光矫正后的早期临床效果评估研究较少。目的探讨和比较SMILE矫正低、中、高度近视的安全性、有效性、可预测性、早期稳定性及术眼角膜恢复特点。方法采用系列病例观察研究方法。纳入2012年5—12月在天津市眼科医院拟行SMILE手术的近视患者108例195眼。根据临床近视分类标准将患眼分为低度近视组(≤-3.00D)、中度近视组(〉-3.00~-6.00D)和高度近视组(〉-6.00D),其中低度近视组39例57眼,中度近视组38例76眼,高度近视组31例62眼,所有术眼均接受SMILE手术,分别于术前及术后1d、1周、1个月、3个月行裸眼视力(UCVA)(LogMAR)、最佳矫正视力(BCVA)(LogMAR)、屈光度、眼压、眼前节和角膜地形图检查,比较各组间术眼的有效性指数、安全性指数、等效球镜度(SE)、可预测性和稳定性。结果术后3个月时,低、中、高度近视组术眼UCVA(LogMAR)〈0.1者分别占100%、97.1%和92.8%;所有术眼术后BCVA均达到术前BCVA;低、中、高度近视组术眼残余SE分别为(-0.07±0.16)、(-0.05±0.20)和(-0.08±0.27)D;低、中、高度近视组术眼的残余SE在±0.5D间者分别占100%、98.7%和93.6%,所有术跟残余SE均在±1.0D内。低、中、高度近视组术眼实际矫正sE均随着术前预计矫正sE的增加而增加(r=0.942、0.959、0.957,均P〈0.001)。结论SMILE矫正低、中及高度近视均有较好的安全性、有效性、可预测性和早期稳定性。低度近视眼术后1周以内角膜创伤恢复时间较中度、高度近视眼略慢;少数高度近视眼在SMILE术后3个月表现出轻度屈光度回退,而中度近视眼SMILE矫正的安全性更好。 展开更多
关键词 近视/手术 角膜激光手术/方法 准分子激光/治疗用途 视力 安全性 可预测性 稳定性 飞秒激光小切口角膜基质透镜取出术
下载PDF
激光表面改性的发展趋势 被引量:28
15
作者 张光钧 李军 李文戈 《金属热处理》 EI CAS CSCD 北大核心 2006年第11期1-7,共7页
从激光表面改性的技术特点及先进制造业的发展需求出发,论述了激光表面改性在纳米表面工程、绿色再制造、复合表面工程、智能制造及柔性加工等领域的发展趋势。
关键词 激光表面改性 纳米表面工程 再制造 复合处理 智能制造 柔性制造 准分子激光
下载PDF
近视眼飞秒激光小切口基质透镜取出术后角膜光学质量的客观评估 被引量:17
16
作者 徐路路 王雁 +4 位作者 吴雅楠 吴文静 李晓晶 窦瑞 张佳媚 《中华实验眼科杂志》 CAS CSCD 北大核心 2017年第2期139-145,共7页
背景目前评价飞秒激光小切口基质透镜取出术(SMILE)术后角膜光学质量的方法多基于单一的散射、衍射或像差因素,因此不能对角膜光学质量进行全面和客观评价,而调制传递函数(MTF)及斯特列尔比(SR)综合了上述多因素评价方法,是评... 背景目前评价飞秒激光小切口基质透镜取出术(SMILE)术后角膜光学质量的方法多基于单一的散射、衍射或像差因素,因此不能对角膜光学质量进行全面和客观评价,而调制传递函数(MTF)及斯特列尔比(SR)综合了上述多因素评价方法,是评估术后角膜光学质量方法学的研究方向。 目的利用角膜MTF及SR客观分析SMILE术后术眼在明视和暗视环境下(分别为3 mm和6 mm瞳孔直径)角膜光学质量的变化。 方法采用系列病例观察研究方法和术眼手术前后自身对照研究设计,纳入2013年12月至2014年3月在天津市眼科医院接受SMILE的患者32例63眼,分别于术前、术后1周、1个月及3个月记录裸眼视力(UCVA)、最佳矫正视力(BCVA)和有效性指数(术后UCVA/术前BCVA);分别于上述时间点对术眼行电脑验光和综合验光仪验光,记录手术前后术眼屈光度变化;采用Sirius眼前节分析系统测定3 mm和6 mm瞳孔直径下不同空间频率(10、20、30、40、50和60 c/d)角膜前表面MTF和SR值,并测定术眼手术前后角膜前表面总高阶像差均方根值(RMS),以评估术眼SMILE手术前后角膜光学质量变化。 结果术后1周、1个月、3个月UCVA(LogMAR)≥0.8者分别为59、62和63眼,分别占93.65%、98.41%和100%,术眼上述时间点有效性指数分别为1.104±0.128、1.126±0.145和1.158±0.208。术眼术后3个月等效球镜度和柱镜度均在正常范围。术眼术后各时间点3 mm瞳孔直径垂直及水平子午线各空间频率下MTF值较术前均明显增加,6 mm瞳孔直径下垂直子午线10、20、30和40 c/d空间频率MTF值较术前明显增加,差异均有统计学意义(均P〈0.05),而手术前后不同时间点6 mm瞳孔直径下水平子午线各空间频率MTF值总体比较差异均无统计学意义(均P〉0.05)。术眼术后各时间点3 mm及6 mm瞳孔直径下的SR与术前相比呈上升趋势,差异均有统计学意义(均P〈0.05);且各时间点3 mm瞳孔直径下SR均大于相应的6 mm瞳孔直径下SR值,差异均有统计学意义(均P〈0.05)。术眼手术前后不同时间点3 mm及6 mm瞳孔直径下角膜前表面RMS总体比较差异均无统计学意义(3 mm瞳孔直径:F=1.348,P=0.184;6 mm瞳孔直径:F=1.990,P=0.137)。 结论SMILE手术可有效改善近视及近视散光患者术后角膜光学成像质量,术眼术后明视环境下较暗视环境下角膜光学质量改善更为明显。 展开更多
关键词 角膜光学质量 激光角膜手术 准分子激光/治疗用途 近视 调制传递函数 斯特尔比率 飞秒激光小切口基质透镜取出术
下载PDF
中西医结合治疗肝肾阴虚型干眼症的疗效观察 被引量:17
17
作者 王学珍 贺义恒 +2 位作者 余晓锐 郑玉祥 刘蓉 《国际眼科杂志》 CAS 2012年第9期1669-1672,共4页
目的:通过对肝肾阴虚型干眼症患者采用"复明片"加减联合睑板腺疏通法临床治疗的疗效观察,说明中西医结合治疗肝肾阴虚型干眼症可以收到良好的效果。方法:对符合干眼症诊断标准的400例患者的性别、年龄、症状、临床表现进行详... 目的:通过对肝肾阴虚型干眼症患者采用"复明片"加减联合睑板腺疏通法临床治疗的疗效观察,说明中西医结合治疗肝肾阴虚型干眼症可以收到良好的效果。方法:对符合干眼症诊断标准的400例患者的性别、年龄、症状、临床表现进行详细记录并进行严格的中医辨证分型,并对辩证为"肝肾阴虚"型的干眼症患者90例随机分三组治疗:A组30例给予"复明片"加减联合睑板腺疏通法加人工泪液治疗;B组30例给予睑板腺疏通法加人工泪液治疗;C组30例给人工泪液治疗。三组患者的自觉症状、泪液分泌试验(SchirmerⅠtest,SⅠt)、泪膜破裂时间(tear break-up time,BUT)、角膜荧光素染色(fluorescein staining,FL)和角膜地形图的角膜表面规则指数(surface regularity index,SRI)和角膜表面不规则指数(surface asymmetry index,SAI)结果作为观察指标,对观察数据进行统计分析,每组治疗前后行配对资料的秩和检验;对三组的疗效行多个样本间两两比较的秩和检验。结果:A组观察指标改善情况及疗效明显优于B,C两组;B组的又优于C组;三组的有效率分别是90.0%,73.3%和53.3%;结论:对肝肾阴虚型干眼症,采用"复明片"加减联合睑板腺管疏通术和人工泪液的治疗方法可以取得良好的治疗效果。睑板腺功能障碍(MGD)直接相关或合并MGD是干眼症的病因之一;同时角膜地形图可以协助诊断和评价干眼症的严重程度和治疗效果。 展开更多
关键词 干眼症 肝肾阴虚证 复明片 睑板腺管疏通术 角膜表面规则指数 角膜表面不规则指数
下载PDF
氯替泼诺混悬滴眼液对准分子激光角膜屈光术后眼压的影响 被引量:6
18
作者 张庆生 王欣 +3 位作者 王忠海 张绍忠 王林 许文鑫 《中华实验眼科杂志》 CAS CSCD 北大核心 2013年第6期551-554,共4页
背景采用准分子激光角膜屈光手术矫正屈光不正可减少患者对框架眼镜的依赖,其术后抗炎药物使用过程中不良反应的防治一直是临床关注的问题。氯替泼诺混悬滴眼液是糖皮质激素类抗炎药,已广泛用于准分子激光角膜屈光术后,以缓解和减轻... 背景采用准分子激光角膜屈光手术矫正屈光不正可减少患者对框架眼镜的依赖,其术后抗炎药物使用过程中不良反应的防治一直是临床关注的问题。氯替泼诺混悬滴眼液是糖皮质激素类抗炎药,已广泛用于准分子激光角膜屈光术后,以缓解和减轻术眼术后的炎症反应,但其长期应用后对眼压影响的报道较少。目的探讨准分子激光角膜屈光手术后使用质量分数0.5%氯替泼诺混悬滴眼液对眼压的影响。方法采用回顾性病例分析研究设计,收集2011年1月至2012年1月在唐山市眼科医院行准分子激光角膜屈光手术并有完整随访资料的近视患者1552例1552眼,其中行准分子激光角膜原位磨镶术(LASIK)者321眼,行准分子激光前弹力层下角膜原位磨镶术(SBK)者608眼,行飞秒激光制瓣准分子激光角膜原位磨镶术(FS—LASIK)者623眼。所有患者术后均应用0.5%氯替泼诺混悬滴眼液点眼,每日4次,每周递减1次,共1个月。术前及术后1、2、3、4周分别用非接触眼压计测量眼压,并根据眼压升高的幅度分为〈5mmHg(1mmHg=0.133kPa)、5~15mmHg和〉15mmHg三种糖皮质激素反应。术后发现眼压升高及眼压恢复正常1个月时采用海德堡视网膜断层扫描仪进行视盘参数的检测和观察,并进行比较。结果纳入的1552眼中,术后1个月内眼压升高者47眼,其中行LASIK者用药后眼压升高者占3.12%(10/321),行SBK者占3.29%(20/608),行FS—LAStK者占2.73%(17/623),三者间比较差异无统计学意义(x2=1.95,P〉0.05)。停用0.5%氯替泼诺混悬滴眼液或加用降眼压药物治疗后,术眼眼压降至正常水平,仅1眼出现轻度反弹,视力无下降。术后眼压升高与眼压恢复后1个月时,受检眼的盘沿面积分别为(1.65±0.44)mm2和(1.66±0.44)mm2,盘沿容积分别为(0.40±0.09)mm2和(0.39±0.08)mm2,平均神经纤维层厚度分别为(0.28±0.08)mm和(0.29±0.07)mm,差异均无统计学意义(t=0.34、0.81、0.48,P〉0.05)。结论准分子激光角膜屈光手术后使用0.5%氯替泼诺混悬滴眼液进行抗炎治疗导致的眼压升高为可逆性,用药期间应定期监测眼压变化。 展开更多
关键词 氯替泼诺混悬滴眼液 准分子激光角膜屈光手术 准分子激光角膜原位磨镶术 准分子激 光前弹力层下角膜原位磨镶术 飞秒激光制瓣准分子激光角膜原位磨镶术 眼压
下载PDF
TransPRK与Epi-LASIK矫治薄角膜近视眼的临床疗效比较 被引量:11
19
作者 侯杰 雷玉琳 郑秀云 《中华实验眼科杂志》 CAS CSCD 北大核心 2015年第6期531-536,共6页
背景单一步骤的经角膜上皮的准分子激光屈光性角膜切削术(TransPRK)是一种新型的表层切削术,术后角膜上皮愈合快,术眼刺激性小,但关于TransPRK术后临床效果的动态性观察、角膜生物力学性能以及角膜后表面形态等的变化研究鲜见报道... 背景单一步骤的经角膜上皮的准分子激光屈光性角膜切削术(TransPRK)是一种新型的表层切削术,术后角膜上皮愈合快,术眼刺激性小,但关于TransPRK术后临床效果的动态性观察、角膜生物力学性能以及角膜后表面形态等的变化研究鲜见报道。目的评价TransPRK矫治薄角膜近视眼的手术效果及安全性,并与机械法准分子激光角膜上皮瓣下磨镶术(Epi-LASIK)进行比较。方法采用前瞻性非随机对照研究设计,收集2013年6-12月在济南市明水眼科医院拟行表层准分子激光手术的近视及近视散光患者93例93眼,均纳入右眼进行分析。术眼术前角膜厚度为460~500μm,其中TransPRK组46眼,Epi-LASIK组47眼,分别于术前及术后1周、1个月、3个月和6个月记录并比较2个组术眼的裸眼视力(UCVA)、屈光度、角膜上皮下雾状混浊(haze)程度、角膜生物力学参数、角膜后表面高度及Q值、角膜像差。结果TransPRK组术后不同时间点视力和屈光度变化的眼数分布与Epi-LASIK组的差异均无统计学意义(均P〉0.05)。术后6个月,TransPRK组UCVA≥1.0者占93.9%,屈光度在±1.00D以内者占90.9%,具有良好的安全性和稳定性。术后1个月haze最明显,TransPRK组有15眼出现haze,占32.6%,Epi-LASIK组有8眼出现haze,占17.4%,均在0.5级以下。TransPRK组haze的发生率略高于Epi-LASIK组,2个组间差异无统计学意义(X^2=2.841,P=0.092)。2个组间角膜滞后量(CH)值和角膜阻力因子(CRF)值的总体差异均无统计学意义(CH:F分组=0.000,P=0.999;CRF:F分组=0.110,P=0.741),但2个组术眼术后CH值和CRF值均明显下降,不同时间点的总体比较差异均有统计学意义(CH:F时间=103.658,P=0.000;CRF:F时间=132.008,P=0.000),其中术后不同时间点CH值和CRF值均较术前明显降低,差异均有统计学意义(均P〈0.01),而术后各时间点间的相互比较差异均无统计学意义(均P〉0.05)。2个组间术后各时间点角膜后表面高度较术前均轻微后移,与术前值比较差异有统计学意义(F时间=12.868,P=0.001),但组间比较差异无统计学意义(F分组=1.923,P=0.169)。2个组手术前后不同时间点术眼角膜后表面Q值总体比较差异均无统计学意义(F分组=0.191,P=0.663;F时间=1.783,P=0.185)。2个组术眼术后各时间点角膜高阶像差均方根(RMS)值与球差值均较术前明显增加,差异均有统计学意义(均P〈0.01),但组间总体比较差异均无统计学意义(角膜RMS:F分组=0.299,P=0.586;角膜球差:F分组=1.290,P=0.259)。结论TransPRK矫正薄角膜的近视眼术后视力和屈光稳定性较好,与Epi—LASIK比较无明显差异;术后早期角膜生物力学性能降低,但随着术后时间的延长逐步恢复;术后角膜后表面高度有轻微后移的现象,但并未影响后表面整体的非球面形态。 展开更多
关键词 近视/手术疗法 准分子激光/治疗用途 屈光性角膜切削术 角膜生物力学 角膜地形图 术后并发症 前瞻性研究
下载PDF
准分子激光直接清洗硅片上油脂的实验研究 被引量:8
20
作者 谭东晖 陆冬生 +2 位作者 宋文栋 范永昌 安承武 《激光技术》 CAS CSCD 1995年第5期319-320,共2页
本文报道了采用输出激光波长为308nm,脉冲宽度为28ns的准分子激光直接清洗硅片上油脂的实验研究,通过改变光束大小或调节激光输出能量来改变基片表面上的激光能量密度,研究激光能量密度对激光清洗效果的影响。从实验中得到... 本文报道了采用输出激光波长为308nm,脉冲宽度为28ns的准分子激光直接清洗硅片上油脂的实验研究,通过改变光束大小或调节激光输出能量来改变基片表面上的激光能量密度,研究激光能量密度对激光清洗效果的影响。从实验中得到硅片的激光清洗阈值为0.2J/cm ̄2,损伤阈值为1.2J/cm ̄2。 展开更多
关键词 准分子激光 表面清洗 油脂 硅片
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部