期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Diagnostics of bronchopulmonary diseases through Mahalanobis distance-based absorption spectral analysis of exhaled air
1
作者 A. A. BULANOVA E. B. BUKREEVA +1 位作者 Yu. V. KISTENEV O. Yu. NIKIFOROV 《Frontiers of Optoelectronics》 CSCD 2015年第2期183-186,共4页
Accurate diagnosis of different bronchopul- monary diseases is important in clinical practice. This study involved 20 healthy volunteers and 77 patients with bronchopulmonary diseases, including chronic obstructive pu... Accurate diagnosis of different bronchopul- monary diseases is important in clinical practice. This study involved 20 healthy volunteers and 77 patients with bronchopulmonary diseases, including chronic obstructive pulmonary disease (COPD), bronchial asthma, pulmonary tuberculosis, and community-acquired pneumonia. The absorption spectrum of exhaled air samples was recorded on an intra-cavity photo-acoustic gas analyzer (ILPA-1, Special Technologies, Ltd., Russia) with photo-acoustic detectors and CO2 laser with a tuning range from 9.2 to 10.8μm. In conclusion, analysis of the Mahalanobis distance-based absorption spectral profiles of breath air from bronchopulmonary patients and healthy volunteers allows the formulation of a preliminary diagnosis. 展开更多
关键词 bronchopulmonary diseases exhaled air Mahalanobis distance laser photo-acoustic spectroscopy C02 laser
原文传递
Multiscattering-enhanced absorbance to enable the sensitive analysis of extremely diluted biological samples: Determination of oxidative potential in exhaled air
2
作者 Sami Goekce Nicolas Concha-Lozano +7 位作者 Jean-Jacques Sauvain Maud Hemmendinger Alejandro Portela Elise Sergent Pascal Andujar Jean-Claude Pairon Pascal Wild Guillaume Suarez 《Medicine in Novel Technology and Devices》 2022年第2期62-66,共5页
Direct determination of the oxidative potential in exhaled air(OPEA)as a biological indicator of the redox balance status in airways requires an extremely sensitive sensing approach to counterbalance the high dilution... Direct determination of the oxidative potential in exhaled air(OPEA)as a biological indicator of the redox balance status in airways requires an extremely sensitive sensing approach to counterbalance the high dilution of the exhaled air matrix.In opposite to standard colorimetric assays based on Beer-Lambert Law,the use of simple multiscattering-enhanced absorbance(MEA)strategy results in an improved photonic sensing system.Based on this strategy and using the ferrous-xylenol orange assay,analytical performances allowing the detection of 3 pmol of H_(2)O_(2) could be obtained.The comparative analysis of photometric configurations–standard vs MEA–highlights the large absorbance gain obtained for tiny H_(2)O_(2) amounts–from 0 to 30 pmol–whereas similar sensing trends are observed at higher concentration range.The automated introduction of exhaled air sample into the reaction compartment via needle-impinger coupled with the MEA-based photonic cell enables ultrasensitive determination of OPEA in short time(<5 min).A pilot study conducted on healthy subjects(n=22)and chronic obstructive pulmonary disease(COPD)patients(n=23)volunteers shows a significant increase of the OPEA for COPD versus controls and strong negative correlation between OPEA and spirometry parameters(Tiffeneau index:FEV1/FVC)for ex-/non-smokers.Application perspectives to assess inflammatory episodes in obstructive lung diseases are thus made possible using this sensing approach. 展开更多
关键词 Absorbance enhancement Photonic device Oxidative potential exhaled air COPD Pilot study
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部