期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification
1
作者 Ahmed Shawky Shawata Tarek El Nimr +1 位作者 Reda Ahmed Morsy Khaled M. Elshahat 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第7期343-349,共7页
Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent do... Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent dosimeters (TLD) is performed in many radiotherapy departments to verify the dose delivered during treatment. A total of 40 TLD divided into two batches (one of 20 and other of 20 TLD) were used. Different doses of Co6~ beam were delivered to the TLD chips at different depths. Diodes were irradiated at different depths in a (30 x 30 x 30) cm3 water slab phantom with various conditions of Field sizes, monitor units and SSDs. Results: The limitation of the in-vivo dosimetry technique is that dose can only be in system readout difficulty and type of readout (TLD system and diode) as the patient dose is directly measured. Several authors have investigated the measurements was 1.3%, with a standard deviation of 2.6%. Results were normally distributed around a mean as -0.39 and 0.34 respectively. After the evaluation of in vivo dosimetry brain case as an example, the mean doses for both eyes were 1.8%, with a standard deviation of 2.7%. These results are similar to studies conducted with diodes and TLD's. Conclusion: The diode is superior to TLD, since the diode measurements can be obtained on line and allows an immediate check. Other advantages of diodes include high sensitivity, good spatial resolution, and small size, simplicity of used. 展开更多
关键词 In vivo dosimetry uncertainty in experimental measurements calibration TLD dosimetry semi-conductor (di-ode) dosimetry
下载PDF
Analysis of the Intrinsic Uncertainties in the Laser-Driven Iron Hugoniot Experiment Based on the Measurement of Velocities
2
作者 章欢 段晓溪 +6 位作者 张琛 刘浩 张惠鸽 薛全喜 叶青 王哲斌 蒋刚 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第8期91-95,共5页
One of the most challenging tasks in the laser-driven Hugoniot experiment is how to increase the reproducibility and precision of the experimental data to meet the stringent requirement in validating equation of state... One of the most challenging tasks in the laser-driven Hugoniot experiment is how to increase the reproducibility and precision of the experimental data to meet the stringent requirement in validating equation of state models. In such cases, the contribution of intrinsic uncertainty becomes important and cannot be ignored. A detailed analysis of the intrinsic uncertainty of the aluminum-iron impedance-match experiment based on the measurement of velocities is presented. The influence of mirror-reflection approximation on the shocked pressure of Fe and intrinsic uncertainties from the equation of state uncertainty of standard material are quantified, Furthermore, the comparison of intrinsic uncertainties of four different experimental approaches is presented. It is shown that, compared with other approaches including the most widely used approach which relies on the measurements of the shock velocities of AI and Fe, the approach which relies on the measurement of the particle velocity of Al and the shock velocity of Fe has the smallest intrinsic uncertainty, which would promote such work to significantly improve the diagnostics precision in such an approach. 展开更多
关键词 of is Analysis of the Intrinsic Uncertainties in the Laser-Driven Iron Hugoniot Experiment Based on the Measurement of Velocities in Al on
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部