The corrosion behaviors and electrochemical properties of Q235 A steel in the treated water containing corrosive halide anions(F-, Cl-) have been investigated with corrosion tests of static coupon and dynamic coupon t...The corrosion behaviors and electrochemical properties of Q235 A steel in the treated water containing corrosive halide anions(F-, Cl-) have been investigated with corrosion tests of static coupon and dynamic coupon testing, electrochemical measurement of open-circuit potential and linear sweep voltammetry. The results reveal that the existence of F-and Cl-ions in the simulated treated water accelerate the corrosion rate of Q235 A steel. The corrosion rate reaches maximum with F-concentration of 50 mg/L, Cl-concentration of 200 mg/L, respectively. However, Q235 A steel would passivate when an applied potential is added to the system. Meanwhile, the initiating passive potential becomes positive with F-, Cl-concentration increasing. There is a little influence of F-, Cl-concentration on the initiating passivation current density. Therefore, it is necessary to control F-, Cl-concentration in the treated water when it is recycled by the pipelines made of Q235 A steel.展开更多
The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a const...The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a constant interfacial area cell with laminar flow were studied,just to elucidate the extraction mechanism and the mass transfer models.The data were analyzed in terms of pseudo-first-order constants.The effects of stirring speed,specific interfacial area and temperature on the extraction rate in both systems were discussed,suggesting that the extractions were mixed bulk phases-interfacial control process.Supported by the experimental data,the corresponding rate equations for Ce(Ⅳ) extraction system and Ce(Ⅳ)-F^- mixture extraction system were obtained.The experimental results indicated the rate-controlling step.The kinetics model was deduced from the rate-controlling step and consistent with the rate equation.展开更多
The purpose of this research was to fmd out effectiveness of chloride solid membrane electrode of coated wire system compared to solid membrane electrode of composite system, the Nernstian response and character's po...The purpose of this research was to fmd out effectiveness of chloride solid membrane electrode of coated wire system compared to solid membrane electrode of composite system, the Nernstian response and character's potential response (detection limit, selectivity and response time). The chloride ISEs (ion selective electrodes) in this research were the solid membrane chloride ISEs based AgC1. There were two types of chloride ISEs that were developed, namely the chloride ISEs of coated wire and composite systems. Both types of electrodes were characterized. The selectivity was done by comparing Esel of the chloride standard solutions and Esel of the interference ions (Br- and I-). The measurement of chloride ions in water samples was done by using the coated wire chloride ISE, the composite chloride ISE and the Mohr method. We compared the result of the two chloride ISE methods to that of standard method for chloride determination (Mohr) by using F-test and Post Hoc Test LSD (least significant difference) and Duncan. Analysis by using F-test and Post Hoc Test (LSD and Duncan) and characterization results of both the methods showed that coated wire chloride ISE was more effective compared to composite chloride ISE. Nemstian response was 59.83 mV/decade, linier range measurement was 10-1-10-5 M, limit detection was 1.23 × 10-5 M, response time along was 25 s and interfering ion was 10-4 M Br-.展开更多
基金Project(2018YFC1900304)supported by the National Key R&D Program of ChinaProject(2018SK2026)supported by the Key R&D Program of Hunan Province,ChinaProject(2017SK2420)supported by the Science and Technology of Hunan Province,China。
文摘The corrosion behaviors and electrochemical properties of Q235 A steel in the treated water containing corrosive halide anions(F-, Cl-) have been investigated with corrosion tests of static coupon and dynamic coupon testing, electrochemical measurement of open-circuit potential and linear sweep voltammetry. The results reveal that the existence of F-and Cl-ions in the simulated treated water accelerate the corrosion rate of Q235 A steel. The corrosion rate reaches maximum with F-concentration of 50 mg/L, Cl-concentration of 200 mg/L, respectively. However, Q235 A steel would passivate when an applied potential is added to the system. Meanwhile, the initiating passive potential becomes positive with F-, Cl-concentration increasing. There is a little influence of F-, Cl-concentration on the initiating passivation current density. Therefore, it is necessary to control F-, Cl-concentration in the treated water when it is recycled by the pipelines made of Q235 A steel.
基金Project (2012CBA01202) supported by the National Basic Research Program of ChinaProject (51174184) supported by the National Natural Science Foundation of China+2 种基金Project (KGZD-EW-201-1) supported by the Key Research Program of the Chinese Academy of SciencesProject (BK2013030) supported by Science and Technology Plan of Nantong City,ChinaProject (RERU2014016) supported by Open Subject of Changchun Institute of Applied Chemistry,Chinese Academy of Sciences,China
文摘The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a constant interfacial area cell with laminar flow were studied,just to elucidate the extraction mechanism and the mass transfer models.The data were analyzed in terms of pseudo-first-order constants.The effects of stirring speed,specific interfacial area and temperature on the extraction rate in both systems were discussed,suggesting that the extractions were mixed bulk phases-interfacial control process.Supported by the experimental data,the corresponding rate equations for Ce(Ⅳ) extraction system and Ce(Ⅳ)-F^- mixture extraction system were obtained.The experimental results indicated the rate-controlling step.The kinetics model was deduced from the rate-controlling step and consistent with the rate equation.
文摘The purpose of this research was to fmd out effectiveness of chloride solid membrane electrode of coated wire system compared to solid membrane electrode of composite system, the Nernstian response and character's potential response (detection limit, selectivity and response time). The chloride ISEs (ion selective electrodes) in this research were the solid membrane chloride ISEs based AgC1. There were two types of chloride ISEs that were developed, namely the chloride ISEs of coated wire and composite systems. Both types of electrodes were characterized. The selectivity was done by comparing Esel of the chloride standard solutions and Esel of the interference ions (Br- and I-). The measurement of chloride ions in water samples was done by using the coated wire chloride ISE, the composite chloride ISE and the Mohr method. We compared the result of the two chloride ISE methods to that of standard method for chloride determination (Mohr) by using F-test and Post Hoc Test LSD (least significant difference) and Duncan. Analysis by using F-test and Post Hoc Test (LSD and Duncan) and characterization results of both the methods showed that coated wire chloride ISE was more effective compared to composite chloride ISE. Nemstian response was 59.83 mV/decade, linier range measurement was 10-1-10-5 M, limit detection was 1.23 × 10-5 M, response time along was 25 s and interfering ion was 10-4 M Br-.