Over the last few years, smart grids have become a topic of intensive research, development and deployment across the world. This is due to the fact that, through the smart grid, stable and reliable power systems can ...Over the last few years, smart grids have become a topic of intensive research, development and deployment across the world. This is due to the fact that, through the smart grid, stable and reliable power systems can be achieved. This paper presents a fuzzy logic control for dual active bridge series resonant converters for DC smart grid application. The DC smart grid consists of wind turbine and photovoltaic generators, controllable and DC loads, and power converters. The proposed control method has been applied to the controllable load's and the grid side's dual active bridge series resonant converters for attaining control of the power system. It has been used for management of controllable load's state of charge, DC feeder's voltage stability during the loads and power variations from wind energy and photovoltaic generation and power flow management between the grid side and the DC smart grid. The effectiveness of the proposed DC smart grid operation has been verified by simulation results obtained by using MATLAB and PLECS cards.展开更多
A homotopy analysis method(HAM)is presented for the primary resonance of multiple degree-of-freedom systems with strong non-linearity excited by harmonic forces.The validity of the HAM is independent of the existenc...A homotopy analysis method(HAM)is presented for the primary resonance of multiple degree-of-freedom systems with strong non-linearity excited by harmonic forces.The validity of the HAM is independent of the existence of small parameters in the considered equation.The HAM provides a simple way to adjust and control the convergence region of the series solution by means of an auxiliary parameter.Two examples are presented to show that the HAM solutions agree well with the results of the modified Linstedt-Poincar'e method and the incremental harmonic balance method.展开更多
Chou and Chen’s report in the 1970s suggested conformational protein adaptation (CPA) might be influenced by low frequency phonons acting as “a possible information system”. This report proposes the universal force...Chou and Chen’s report in the 1970s suggested conformational protein adaptation (CPA) might be influenced by low frequency phonons acting as “a possible information system”. This report proposes the universal force of electromagnetism initiates the phonon system they cited as it per-turbs paramagnetic/diamagnetic dampers within the protein matrix to produce a quantized low frequency phonon signal series. (http://www.phy.ilstu.edu/~ren/phononsims/page3.html) The signal series is iteratively processed by the protein beta sub-unit, the system, to posi-tion the alpha sub-unit, the outcome, a classic non-linear resonance system resulting in con-formational protein adaptation (CPA). CPA “priming” enables a secondary ATP/redox driven power system to complete cell activity. The evolutionary appearance of these two systems reflects their hierarchy: 1) a low energy phonon driven information control circuit governed by principles of physics that, along with proteins, may have preceded planet earth, and 2), an ATP/redox power completion circuit directed by principles of chemistry that evolved in living systems 1 billion or more years after earth formed.展开更多
基于移相控制的双有源桥串联谐振变换器(dual-bridge series resonant converter,DBSRC)在传输功率的快速调控过程中,移相角将发生较大的阶跃变化,导致谐振腔出现大幅度长时间的振荡过程,不仅严重恶化了变换器的动态性能,电路元件也会...基于移相控制的双有源桥串联谐振变换器(dual-bridge series resonant converter,DBSRC)在传输功率的快速调控过程中,移相角将发生较大的阶跃变化,导致谐振腔出现大幅度长时间的振荡过程,不仅严重恶化了变换器的动态性能,电路元件也会面临严重的过电压和过电流风险。该文首先基于基波分析法推导DBSRC暂态过程的通用计算模型,分析暂态过程中的振荡特性,精确估算暂态过程中的谐振电压峰值、谐振电流峰值以及暂态过渡时间,评估暂态过程中的过电压与过电流程度。基于暂态过程计算模型,提出一种振荡的抑制方法,使变换器在一个开关周期后能够到达新的稳定状态,有效地避免了过电压与过电流的风险,并且大幅改善了闭环控制的动态特性。最后,通过仿真与实验结果验证理论分析和所提出的控制方法。展开更多
文摘Over the last few years, smart grids have become a topic of intensive research, development and deployment across the world. This is due to the fact that, through the smart grid, stable and reliable power systems can be achieved. This paper presents a fuzzy logic control for dual active bridge series resonant converters for DC smart grid application. The DC smart grid consists of wind turbine and photovoltaic generators, controllable and DC loads, and power converters. The proposed control method has been applied to the controllable load's and the grid side's dual active bridge series resonant converters for attaining control of the power system. It has been used for management of controllable load's state of charge, DC feeder's voltage stability during the loads and power variations from wind energy and photovoltaic generation and power flow management between the grid side and the DC smart grid. The effectiveness of the proposed DC smart grid operation has been verified by simulation results obtained by using MATLAB and PLECS cards.
基金supported by the Fundamental Research Funds for the Central Universities(No.N090405009)
文摘A homotopy analysis method(HAM)is presented for the primary resonance of multiple degree-of-freedom systems with strong non-linearity excited by harmonic forces.The validity of the HAM is independent of the existence of small parameters in the considered equation.The HAM provides a simple way to adjust and control the convergence region of the series solution by means of an auxiliary parameter.Two examples are presented to show that the HAM solutions agree well with the results of the modified Linstedt-Poincar'e method and the incremental harmonic balance method.
文摘Chou and Chen’s report in the 1970s suggested conformational protein adaptation (CPA) might be influenced by low frequency phonons acting as “a possible information system”. This report proposes the universal force of electromagnetism initiates the phonon system they cited as it per-turbs paramagnetic/diamagnetic dampers within the protein matrix to produce a quantized low frequency phonon signal series. (http://www.phy.ilstu.edu/~ren/phononsims/page3.html) The signal series is iteratively processed by the protein beta sub-unit, the system, to posi-tion the alpha sub-unit, the outcome, a classic non-linear resonance system resulting in con-formational protein adaptation (CPA). CPA “priming” enables a secondary ATP/redox driven power system to complete cell activity. The evolutionary appearance of these two systems reflects their hierarchy: 1) a low energy phonon driven information control circuit governed by principles of physics that, along with proteins, may have preceded planet earth, and 2), an ATP/redox power completion circuit directed by principles of chemistry that evolved in living systems 1 billion or more years after earth formed.
文摘基于移相控制的双有源桥串联谐振变换器(dual-bridge series resonant converter,DBSRC)在传输功率的快速调控过程中,移相角将发生较大的阶跃变化,导致谐振腔出现大幅度长时间的振荡过程,不仅严重恶化了变换器的动态性能,电路元件也会面临严重的过电压和过电流风险。该文首先基于基波分析法推导DBSRC暂态过程的通用计算模型,分析暂态过程中的振荡特性,精确估算暂态过程中的谐振电压峰值、谐振电流峰值以及暂态过渡时间,评估暂态过程中的过电压与过电流程度。基于暂态过程计算模型,提出一种振荡的抑制方法,使变换器在一个开关周期后能够到达新的稳定状态,有效地避免了过电压与过电流的风险,并且大幅改善了闭环控制的动态特性。最后,通过仿真与实验结果验证理论分析和所提出的控制方法。