A new multi-channel far infrared (FIR) laser interferometer was built up and ap- plied to HL-2A. The unique feature of real-time heterodyne interferometer is the combination of high power radiation source (300 mW)...A new multi-channel far infrared (FIR) laser interferometer was built up and ap- plied to HL-2A. The unique feature of real-time heterodyne interferometer is the combination of high power radiation source (300 mW), lower noise room temperature detector (noise tempera- ture below 6000 K) with good spatial resolution of 7 cm. Various parameters are optimized for maximum laser output power. Zero crossings of the signals are counted with field programmable gate array (FPGA) digital circuitry yielding the resolution of 1/1000 fringe. The newly measured results including density fluctuation are also presented.展开更多
Structure, improvements and experiment results of a vertical three-channel far- in- frared (FIR) hydrogen cyanide (HCN) laser interferometer, operated routinely in EAST to measure the electron density profile, are...Structure, improvements and experiment results of a vertical three-channel far- in- frared (FIR) hydrogen cyanide (HCN) laser interferometer, operated routinely in EAST to measure the electron density profile, are presented. Moreover, a five-channel deuterium cyanide (DCN) laser interferometer was developed successfully. Some key issues confronted in development, including the economization of working gas and the solution to atmospheric absorption, are resolved and described in detail.展开更多
基金National Natural Science Foundation of China (Nos.10575030,10675043)the JSPS-CAS Core University Program in the field of Plasma and Nuclear Fusion
文摘A new multi-channel far infrared (FIR) laser interferometer was built up and ap- plied to HL-2A. The unique feature of real-time heterodyne interferometer is the combination of high power radiation source (300 mW), lower noise room temperature detector (noise tempera- ture below 6000 K) with good spatial resolution of 7 cm. Various parameters are optimized for maximum laser output power. Zero crossings of the signals are counted with field programmable gate array (FPGA) digital circuitry yielding the resolution of 1/1000 fringe. The newly measured results including density fluctuation are also presented.
文摘Structure, improvements and experiment results of a vertical three-channel far- in- frared (FIR) hydrogen cyanide (HCN) laser interferometer, operated routinely in EAST to measure the electron density profile, are presented. Moreover, a five-channel deuterium cyanide (DCN) laser interferometer was developed successfully. Some key issues confronted in development, including the economization of working gas and the solution to atmospheric absorption, are resolved and described in detail.