In order to investigate whether an air–water plasma jet is beneficial to improve the efficiency of inactivation, a series of experiments were done using a ring-needle plasma jet. The water content in the working gas...In order to investigate whether an air–water plasma jet is beneficial to improve the efficiency of inactivation, a series of experiments were done using a ring-needle plasma jet. The water content in the working gas(air) was accurately measured based on the Karl Fischer method. The effects of water on the production of OH(A;Σ;–X;Π;) and O(3p;P–3s;S) were also studied by optical emission spectroscopy. The results show that the water content is in the range of 2.53–9.58 mg l;, depending on the gas/water mixture ratio. The production of OH(A;Σ;–X;Π;) rises with the increase of water content, whereas the O(3p;P–3s;S) shows a declining tendency with higher water content. The sterilization experiments indicate that this air–water plasma jet inactivates the P. digitatum spores very effectively and its efficiency rises with the increase of the water content. It is possible that OH(A;Σ;–X;Π;) is a more effective species in inactivation than O(3p;P–3s;S) and the water content benefit the spore germination inhibition through rising the OH(A;Σ;–X;Π;) production. The maximum of the inactivation efficacy is up to 93% when the applied voltage is -6.75 kV and the water content is 9.58 mg l;.展开更多
特征提取和健康状态的辨识是复杂系统健康状态评估中的关键问题。提出一种新的健康状态评估方法,该方法分为3个步骤:首先,采用经验模态分解(empirical model decomposition,EMD)和奇异值分解(singular value decomposition,SVD)来提取...特征提取和健康状态的辨识是复杂系统健康状态评估中的关键问题。提出一种新的健康状态评估方法,该方法分为3个步骤:首先,采用经验模态分解(empirical model decomposition,EMD)和奇异值分解(singular value decomposition,SVD)来提取振动信号的特征变量。然后,运用马田系统(Mahalanobis-Taguchi system,MTS)构造马氏空间,并对其进行优化,从而降低特征变量的维度。最后,提出了一种健康度(health index,HI)的概念,并且用来对复杂系统健康问题进行评估。该方法成功地应用在轴承的健康状态评估中。展开更多
基金supported by National Natural Science Foundation of China (NSFC) under Grants No. 51407020National Key Technology Research and Development Program of the Ministry of Science and Technology of China under Grants No. 2014BAC13B05Visiting Scholarship of State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University) No. 2007DA10512716404
文摘In order to investigate whether an air–water plasma jet is beneficial to improve the efficiency of inactivation, a series of experiments were done using a ring-needle plasma jet. The water content in the working gas(air) was accurately measured based on the Karl Fischer method. The effects of water on the production of OH(A;Σ;–X;Π;) and O(3p;P–3s;S) were also studied by optical emission spectroscopy. The results show that the water content is in the range of 2.53–9.58 mg l;, depending on the gas/water mixture ratio. The production of OH(A;Σ;–X;Π;) rises with the increase of water content, whereas the O(3p;P–3s;S) shows a declining tendency with higher water content. The sterilization experiments indicate that this air–water plasma jet inactivates the P. digitatum spores very effectively and its efficiency rises with the increase of the water content. It is possible that OH(A;Σ;–X;Π;) is a more effective species in inactivation than O(3p;P–3s;S) and the water content benefit the spore germination inhibition through rising the OH(A;Σ;–X;Π;) production. The maximum of the inactivation efficacy is up to 93% when the applied voltage is -6.75 kV and the water content is 9.58 mg l;.
文摘特征提取和健康状态的辨识是复杂系统健康状态评估中的关键问题。提出一种新的健康状态评估方法,该方法分为3个步骤:首先,采用经验模态分解(empirical model decomposition,EMD)和奇异值分解(singular value decomposition,SVD)来提取振动信号的特征变量。然后,运用马田系统(Mahalanobis-Taguchi system,MTS)构造马氏空间,并对其进行优化,从而降低特征变量的维度。最后,提出了一种健康度(health index,HI)的概念,并且用来对复杂系统健康问题进行评估。该方法成功地应用在轴承的健康状态评估中。
文摘将经过多级破碎分选所得的废线路板粉末过60目筛,以2 mol/L HCl溶液、超纯水洗涤,并用丙酮脱水。将预处理后的滤渣、滤纸填入萃取池,或者用新滤纸包裹后置于索氏提取管内,添加5μL内标物,分别用加速溶剂萃取法(ASE)或索氏提取(SE)法进行萃取,依次采用多层硅胶柱和活性炭柱对萃取提取物进行净化、洗脱,得到二噁英测试样品。用同位素稀释-高分辨气相色谱-质谱联用仪分析样品中二噁英的含量。考察两种提取方法及不同氯代数对15种^(13)C-2,3,7,8-PCDD/Fs回收率的影响,比较两种方法的准确度和精密度。结果表明,ASE和SE对15种^(13)C-2,3,7,8-PCDD/Fs的回收率分别为54.3%~113.0%和28.3%~77.7%,实测废线路板中二噁英毒性当量(Toxic equivalent quangtity,TEQ)分别为0.075 ng TEQ/kg和0.266 ng TEQ/kg。在方法精密度允许范围内,ASE相对具有简单快速、溶剂用量少和准确的优势。