Dopamine transporter (DAT) mediates the regulation of dopaminergic function. Two agents of TRODAT-1 and FP-CIT were observed in evaluating DAT change of Parkinson's disease (PD). The relationship between them was ...Dopamine transporter (DAT) mediates the regulation of dopaminergic function. Two agents of TRODAT-1 and FP-CIT were observed in evaluating DAT change of Parkinson's disease (PD). The relationship between them was also evaluated. The results suggested that 99mTc-TRODAT-1 SPECT and 131I-FP-CIT SPECT may serve as sensitive and objective in vivo markers to reflect the severity of PD. The 99mTc-TRODAT-1 image is more accurate and clearer compared with 131I-FP-CIT.展开更多
The ligand of N-(3-fluoropropyl)-2β-carbomethoxy-3β-(4’-iodophenyl) nortropane (FP-β-CIT) and mesylate precursor were synthesized by hydrolysis of cocaine, followed by dehydration, esterification, Grignard reactio...The ligand of N-(3-fluoropropyl)-2β-carbomethoxy-3β-(4’-iodophenyl) nortropane (FP-β-CIT) and mesylate precursor were synthesized by hydrolysis of cocaine, followed by dehydration, esterification, Grignard reaction, N-demethylation, iodination, N-alkylation with 3-bromopropanol and methylsulfonylation. Finally, 18F-FP-β-CIT was prepared by nucleophilic fluorination of the mesylate with K18F/K2.2.2 (Kryptofix). The labeling yield of 18F-FP-β-CIT is 25%~30%. The total radiochemical yield of this compound, calculated from the end of bombardment (EOB) with decay correction, is 10%~12% with a synthesis time of 100~110.min. The radiochemical purity of 18F-FP-β-CIT is greater than 90%, and this compound in aqueous solution is also stable for more than 4 hours at room temperature. It is stable enough for clinical study.展开更多
The paper is to study pharmacologic characteristics of 18F-FP-β-CIT (18F-N-(3-fluoropropyl)-2β-carbomethoxy-3β- (4-iodophenyl)nortropane) as an imaging agent for dopamine transporter. The radiochemical purity of 18...The paper is to study pharmacologic characteristics of 18F-FP-β-CIT (18F-N-(3-fluoropropyl)-2β-carbomethoxy-3β- (4-iodophenyl)nortropane) as an imaging agent for dopamine transporter. The radiochemical purity of 18F-FP-β-CIT in aqueous solution was over 95% after standing at room temperature for 4h. Biodistribution displayed rapid uptake in rat brain (1.375 %ID/organ at 5min and 0.100 %ID/organ at 180 min) and the striatal uptake was 1.444, 0.731, 0.397, 0.230 and 0.146 %ID/g at 5, 30, 60, 120 and 180 min, respectively. The values of striatum/cerebellum, striatum /frontal cortex and striatum / hippocampus in rat's brain at 30 min were 3.38, 2.17 and 2.40 respectively. The uptake in striatum can be blocked by β-CFT, suggesting that 18F-FP-β-CIT binds to DAT peculiarly. The compound was rapidly cleared from monkey's blood. The striatal uptake was bilaterally decreased in the left-sided lesioned PD rats, compared with normal control. Brain PET imaging studies in normal monkey showed that 18F-FP-β-CIT was concentrated in striatum. The test of undue toxicity showed that the dose received by mice was 1250 times as by human, which indicates that 18F-FP-β-CIT is very safe. So 18F-FP-β-CIT is a promising PET imaging agent for DAT with safety and validity.展开更多
To the best of our knowledge no multicenter studies have been published using standardized semi-quantitative evaluation of [123I]FP-CIT scan (DAT-SPECT). The aims of this study were: 1) to cross-compare semi-quantitat...To the best of our knowledge no multicenter studies have been published using standardized semi-quantitative evaluation of [123I]FP-CIT scan (DAT-SPECT). The aims of this study were: 1) to cross-compare semi-quantitative software-assisted evaluations of DAT-SPECTs performed in three centers with different equipments;2) to assess the accuracy of semi-quantitative evaluations of DAT-SPECT and 3) to identify the threshold with the best accuracy, sensitivity and specificity in a patient population with suspected parkinsonian syndrome. Materials and Methods: Two hundred twenty patients (mean age at the time of SPECT acquisition, 67.4 ± 9.5 yy) acquired in three centers (Ospedale San Luigi Gonzaga;Ospedale San Giovanni Battista Molinette;Ospedale Mauriziano Umberto I) were included. All of them underwent DAT-SPECT from January 2006 to July 2010. All exams were analyzed with the freely available software BASGAN and semi-quantitative data were used to predict disease. In particular, analyses were based on the values from the most deteriorated putamen and caudate, normalized for age and corrected for equipment. ROC analysis was performed and area under the curve (AUC) was estimated. Results: Analysis showed high AUCs (0.898, 0.864, 0.900 and 0.891 for each center and for the multicenter setting, respectively) confirming the very good accuracies reached. The best cut-off were 0.72 and 0.82 for putamen and caudate respectively. These thresholds allowed sensitivities and specificities in each center and in the multicenter setting of 76% and 96%, 91% and 82%, 93% and 90%, 86% and 89% respectively. No significant differences were observed between sensibility and specificity in each center. Conclusion: A unique threshold useful for all centers with high and similar sensitivities and specificities is possible after correction for age and equipments. The high accuracy reached in this multicenter trial by the semi-quantitative analysis seems similar to accuracies from qualitative analysis in other multicenter studies.展开更多
基金National "Tenth Five" Scientific Technique Research Plan Project (2001BA702B02)
文摘Dopamine transporter (DAT) mediates the regulation of dopaminergic function. Two agents of TRODAT-1 and FP-CIT were observed in evaluating DAT change of Parkinson's disease (PD). The relationship between them was also evaluated. The results suggested that 99mTc-TRODAT-1 SPECT and 131I-FP-CIT SPECT may serve as sensitive and objective in vivo markers to reflect the severity of PD. The 99mTc-TRODAT-1 image is more accurate and clearer compared with 131I-FP-CIT.
基金the National Natural Science Foundation (39770230) Natural Science Foundation ofJiangsu Province (BK99163) and Department of
文摘The ligand of N-(3-fluoropropyl)-2β-carbomethoxy-3β-(4’-iodophenyl) nortropane (FP-β-CIT) and mesylate precursor were synthesized by hydrolysis of cocaine, followed by dehydration, esterification, Grignard reaction, N-demethylation, iodination, N-alkylation with 3-bromopropanol and methylsulfonylation. Finally, 18F-FP-β-CIT was prepared by nucleophilic fluorination of the mesylate with K18F/K2.2.2 (Kryptofix). The labeling yield of 18F-FP-β-CIT is 25%~30%. The total radiochemical yield of this compound, calculated from the end of bombardment (EOB) with decay correction, is 10%~12% with a synthesis time of 100~110.min. The radiochemical purity of 18F-FP-β-CIT is greater than 90%, and this compound in aqueous solution is also stable for more than 4 hours at room temperature. It is stable enough for clinical study.
基金the National Natural Science Foundation of China (30570518)Science Foundation of Health Department of Jiangsu Province (H200401)
文摘The paper is to study pharmacologic characteristics of 18F-FP-β-CIT (18F-N-(3-fluoropropyl)-2β-carbomethoxy-3β- (4-iodophenyl)nortropane) as an imaging agent for dopamine transporter. The radiochemical purity of 18F-FP-β-CIT in aqueous solution was over 95% after standing at room temperature for 4h. Biodistribution displayed rapid uptake in rat brain (1.375 %ID/organ at 5min and 0.100 %ID/organ at 180 min) and the striatal uptake was 1.444, 0.731, 0.397, 0.230 and 0.146 %ID/g at 5, 30, 60, 120 and 180 min, respectively. The values of striatum/cerebellum, striatum /frontal cortex and striatum / hippocampus in rat's brain at 30 min were 3.38, 2.17 and 2.40 respectively. The uptake in striatum can be blocked by β-CFT, suggesting that 18F-FP-β-CIT binds to DAT peculiarly. The compound was rapidly cleared from monkey's blood. The striatal uptake was bilaterally decreased in the left-sided lesioned PD rats, compared with normal control. Brain PET imaging studies in normal monkey showed that 18F-FP-β-CIT was concentrated in striatum. The test of undue toxicity showed that the dose received by mice was 1250 times as by human, which indicates that 18F-FP-β-CIT is very safe. So 18F-FP-β-CIT is a promising PET imaging agent for DAT with safety and validity.
文摘To the best of our knowledge no multicenter studies have been published using standardized semi-quantitative evaluation of [123I]FP-CIT scan (DAT-SPECT). The aims of this study were: 1) to cross-compare semi-quantitative software-assisted evaluations of DAT-SPECTs performed in three centers with different equipments;2) to assess the accuracy of semi-quantitative evaluations of DAT-SPECT and 3) to identify the threshold with the best accuracy, sensitivity and specificity in a patient population with suspected parkinsonian syndrome. Materials and Methods: Two hundred twenty patients (mean age at the time of SPECT acquisition, 67.4 ± 9.5 yy) acquired in three centers (Ospedale San Luigi Gonzaga;Ospedale San Giovanni Battista Molinette;Ospedale Mauriziano Umberto I) were included. All of them underwent DAT-SPECT from January 2006 to July 2010. All exams were analyzed with the freely available software BASGAN and semi-quantitative data were used to predict disease. In particular, analyses were based on the values from the most deteriorated putamen and caudate, normalized for age and corrected for equipment. ROC analysis was performed and area under the curve (AUC) was estimated. Results: Analysis showed high AUCs (0.898, 0.864, 0.900 and 0.891 for each center and for the multicenter setting, respectively) confirming the very good accuracies reached. The best cut-off were 0.72 and 0.82 for putamen and caudate respectively. These thresholds allowed sensitivities and specificities in each center and in the multicenter setting of 76% and 96%, 91% and 82%, 93% and 90%, 86% and 89% respectively. No significant differences were observed between sensibility and specificity in each center. Conclusion: A unique threshold useful for all centers with high and similar sensitivities and specificities is possible after correction for age and equipments. The high accuracy reached in this multicenter trial by the semi-quantitative analysis seems similar to accuracies from qualitative analysis in other multicenter studies.