The present paper concerns the fracture characteristics and ductility of cracked concrete beam externally bonded with carbon fiber-reinforced polymer (CFRP) sheet as well as the integration behaviors between CFRP/conc...The present paper concerns the fracture characteristics and ductility of cracked concrete beam externally bonded with carbon fiber-reinforced polymer (CFRP) sheet as well as the integration behaviors between CFRP/concrete interfacial debonding and concrete cracking.Three-point bending tests were carried out on the CFRP-strengthened cracked concrete beams with varying specimen depth and initial crack length.A straingauge method was developed to monitor the crack initiation and propagation in concrete,and the CFRP/concrete interfacial bonding behaviors,respectively.Clip gauges were used to measure crack mouth opening displacement (CMOD) and the deflection at midspan.Experimental results revealed that CFRP-strengthened specimen shows a higher load capacity under the same deformation level and a better inelastic deformation capacity compared with the unstrengthened one.For there are two manifest peak values in the obtained load versus displacement curve,the ductility of CFRP-strengthened concrete beams were investigated using index expressed as area ratio on the load versus displacement curve.The calculated results indicated that the contribution from CFRP sheet to the ductility improvement of specimen is notable when the deflection at midspan exceeded 10.5 times the first-crack deflection.展开更多
Peeling-off phenomena in FRP strengthened concrete beams are investigated in this paper. Based on the beam theory and the fracture mechanics, a new theoretical model is proposed to analyze the peeling-off behavior nea...Peeling-off phenomena in FRP strengthened concrete beams are investigated in this paper. Based on the beam theory and the fracture mechanics, a new theoretical model is proposed to analyze the peeling-off behavior near FRP-concrete interfaces, which is governed by residual thermal stresses. Numerical examples are presented to provide a clear insight into the failure mechanism. Some suggestions are provided for the optimal design of FRP strengthened structures.展开更多
Fiber reinforced polymer (FRP) composites are increasingly being used for the re-pair and strengthening of deteriorated concrete structural components through adhesive bonding of prefabricated strips/plates and the ...Fiber reinforced polymer (FRP) composites are increasingly being used for the re-pair and strengthening of deteriorated concrete structural components through adhesive bonding of prefabricated strips/plates and the wet lay-up of fabric. Interfacial bond failure modes have attracted the attention of researchers because of the importance. The objective of the present study is to analyse the interface failure mechanism of reinforced concrete continuous beam strength-ened by FRP. An analytical solution has been firstly presented to predict the entire debonding process of the model. The realistic bi-linear bond-slip interfacial law was adopted to study this problem. The crack propagation process of the loaded model was divided into four stages (elastic,elastic-softening,elastic-softening-debonded and softening-debonded stage). Among them,elastic-softening-debonded stage has four sub-stages. The equations are solved by adding suitable stress and displacement boundary conditions. Finally,critical value of bond length is determined to make the failure mechanism in the paper effective by solving the simultaneously linear algebraic equations. The interaction between the upper and lower FRP plates can be neglected if axial stiffness ratio of the concrete-to-plate prism is large enough.展开更多
Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case ...Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.展开更多
基金The National Natural Science Foundation of China(No.52171270,51879168,51679150)the Joint Fund for Water Science Research of the Yellow River(No.U2243223)。
基金Sponsored by the National Natural Science Foundation of China (Grant No. 50578025)the National Key Project of Science and Technology (Grant No. 2006BAJ03A03-09)
文摘The present paper concerns the fracture characteristics and ductility of cracked concrete beam externally bonded with carbon fiber-reinforced polymer (CFRP) sheet as well as the integration behaviors between CFRP/concrete interfacial debonding and concrete cracking.Three-point bending tests were carried out on the CFRP-strengthened cracked concrete beams with varying specimen depth and initial crack length.A straingauge method was developed to monitor the crack initiation and propagation in concrete,and the CFRP/concrete interfacial bonding behaviors,respectively.Clip gauges were used to measure crack mouth opening displacement (CMOD) and the deflection at midspan.Experimental results revealed that CFRP-strengthened specimen shows a higher load capacity under the same deformation level and a better inelastic deformation capacity compared with the unstrengthened one.For there are two manifest peak values in the obtained load versus displacement curve,the ductility of CFRP-strengthened concrete beams were investigated using index expressed as area ratio on the load versus displacement curve.The calculated results indicated that the contribution from CFRP sheet to the ductility improvement of specimen is notable when the deflection at midspan exceeded 10.5 times the first-crack deflection.
基金supported by the National Basic Research Program of China(No.2007CB714102)the National Natural Science Foundation of China(No.50979048)
文摘Peeling-off phenomena in FRP strengthened concrete beams are investigated in this paper. Based on the beam theory and the fracture mechanics, a new theoretical model is proposed to analyze the peeling-off behavior near FRP-concrete interfaces, which is governed by residual thermal stresses. Numerical examples are presented to provide a clear insight into the failure mechanism. Some suggestions are provided for the optimal design of FRP strengthened structures.
基金supported by the Scheme of Science and Technology of Guangdong Province (2005B32801002), China
文摘Fiber reinforced polymer (FRP) composites are increasingly being used for the re-pair and strengthening of deteriorated concrete structural components through adhesive bonding of prefabricated strips/plates and the wet lay-up of fabric. Interfacial bond failure modes have attracted the attention of researchers because of the importance. The objective of the present study is to analyse the interface failure mechanism of reinforced concrete continuous beam strength-ened by FRP. An analytical solution has been firstly presented to predict the entire debonding process of the model. The realistic bi-linear bond-slip interfacial law was adopted to study this problem. The crack propagation process of the loaded model was divided into four stages (elastic,elastic-softening,elastic-softening-debonded and softening-debonded stage). Among them,elastic-softening-debonded stage has four sub-stages. The equations are solved by adding suitable stress and displacement boundary conditions. Finally,critical value of bond length is determined to make the failure mechanism in the paper effective by solving the simultaneously linear algebraic equations. The interaction between the upper and lower FRP plates can be neglected if axial stiffness ratio of the concrete-to-plate prism is large enough.
文摘Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.