In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completi...In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior.展开更多
Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enabl...Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enables testing of small specimens under complex thermomechanical loading conditions. In order to cope with the simulation of well defined biaxial proportional and non-proportional loadings with in-phase and out-of-phase superposition of thermal loads a cruciform biaxial fatigue testing machine has been developed. Special design features of both machines, and the specimens tested, as well as typical test results were discussed.展开更多
文摘In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior.
文摘Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enables testing of small specimens under complex thermomechanical loading conditions. In order to cope with the simulation of well defined biaxial proportional and non-proportional loadings with in-phase and out-of-phase superposition of thermal loads a cruciform biaxial fatigue testing machine has been developed. Special design features of both machines, and the specimens tested, as well as typical test results were discussed.