The distribution network exhibits complex structural characteristics,which makes fault localization a challenging task.Especially when a branch of the multi-branch distribution network fails,the traditional multi-bran...The distribution network exhibits complex structural characteristics,which makes fault localization a challenging task.Especially when a branch of the multi-branch distribution network fails,the traditional multi-branch fault location algorithm makes it difficult to meet the demands of high-precision fault localization in the multi-branch distribution network system.In this paper,the multi-branch mainline is decomposed into single branch lines,transforming the complex multi-branch fault location problem into a double-ended fault location problem.Based on the different transmission characteristics of the fault-traveling wave in fault lines and non-fault lines,the endpoint reference time difference matrix S and the fault time difference matrix G were established.The time variation rule of the fault-traveling wave arriving at each endpoint before and after a fault was comprehensively utilized.To realize the fault segment location,the least square method was introduced.It was used to find the first-order fitting relation that satisfies the matching relationship between the corresponding row vector and the first-order function in the two matrices,to realize the fault segment location.Then,the time difference matrix is used to determine the traveling wave velocity,which,combined with the double-ended traveling wave location,enables accurate fault location.展开更多
In this paper,a fault location method for the petal-shaped distribution network(PSDN)with inverter-interfaced distributed generators(IIDGs)is proposed to shorten the time of manual inspection.In order to calculate the...In this paper,a fault location method for the petal-shaped distribution network(PSDN)with inverter-interfaced distributed generators(IIDGs)is proposed to shorten the time of manual inspection.In order to calculate the fault position,the closed-loop structure of the PSDN is skillfully exploited,and the common control strategies of IIDGs are considered.For asymmetrical faults,a fault line identification formula based on the negative-sequence current phase differences is presented,and a fault location formula only utilizing the negative-sequence current amplitudes is derived to calculated the fault position.For symmetrical faults,the positive-sequence current at both ends of lines and the current output from IIDGs are used to identify the fault line,and the positive-sequence current on multiple lines are used to pinpoint the fault position.In this method,corresponding current phasors are separated into amplitudes and phases to satisfy the limitation of communication level.The simulation results show that the error is generally less than 1%,and the accuracy of the proposed method is not affected by the fault type,fault position,fault resistance,load current,and the IIDG penetration.展开更多
The single-line-to-ground faults with line breaks(SLGFs-LBs)occur more and more frequently in distribution networks and can cause major safety accidents.It is difficult to distinguish the single-line-to-ground faults(...The single-line-to-ground faults with line breaks(SLGFs-LBs)occur more and more frequently in distribution networks and can cause major safety accidents.It is difficult to distinguish the single-line-to-ground faults(SLGFs)in resonant grounding systems and ungrounding systems due to the same electrical characteristics on the source side and uncertain operation conditions of distribution networks.This paper proposes a method for distinguishing SLGFs-LBs and SLGFs.First,the source-side and load-side voltage characteristics of SLGFs and SLGFs-LBs are analyzed,and the phase difference between the voltages of the fault phase and non-fault phase on the load side is selected as the identification criterion.Phasor measurement units(PMUs)are selected as measuring devices.Then,the effects of operation conditions and external devices in distribution networks on the proposed method are discussed,and the phase errors caused by them are calculated to correct the identification method.Finally,the field testing and simulation experiments are conducted to verify the effectiveness and robustness of the proposed method.展开更多
Identification of faulty feeders in resonant grounding distribution networks remains a significant challenge dueto the weak fault current and complicated working conditions.In this paper, we present a deep learning-ba...Identification of faulty feeders in resonant grounding distribution networks remains a significant challenge dueto the weak fault current and complicated working conditions.In this paper, we present a deep learning-based multi-labelclassification framework to reliably distinguish the faulty feeder.Three different neural networks (NNs) including the multilayerperceptron, one-dimensional convolutional neural network (1DCNN), and 2D CNN are built. However, the labeled data maybe difficult to obtain in the actual environment. We use thesimplified simulation model based on a full-scale test field (FSTF)to obtain sufficient labeled source data. Being different frommost learning-based methods, assuming that the distribution ofsource domain and target domain is identical, we propose asamples-based transfer learning method to improve the domainadaptation by using samples in the source domain with properweights. The TrAdaBoost algorithm is adopted to update theweights of each sample. The recorded data obtained in the FSTFare utilized to test the domain adaptability. According to ourvalidation and testing, the validation accuracies are high whenthere is sufficient labeled data for training the proposed NNs.The proposed 2D CNN has the best domain adaptability. TheTrAdaBoost algorithm can help the NNs to train an efficientclassifier that has better domain adaptation. It has been thereforeconcluded that the proposed method, especially the 2D CNN, issuitable for actual distribution networks.展开更多
基金This work was funded by the project of State Grid Hunan Electric Power Research Institute(No.SGHNDK00PWJS2210033).
文摘The distribution network exhibits complex structural characteristics,which makes fault localization a challenging task.Especially when a branch of the multi-branch distribution network fails,the traditional multi-branch fault location algorithm makes it difficult to meet the demands of high-precision fault localization in the multi-branch distribution network system.In this paper,the multi-branch mainline is decomposed into single branch lines,transforming the complex multi-branch fault location problem into a double-ended fault location problem.Based on the different transmission characteristics of the fault-traveling wave in fault lines and non-fault lines,the endpoint reference time difference matrix S and the fault time difference matrix G were established.The time variation rule of the fault-traveling wave arriving at each endpoint before and after a fault was comprehensively utilized.To realize the fault segment location,the least square method was introduced.It was used to find the first-order fitting relation that satisfies the matching relationship between the corresponding row vector and the first-order function in the two matrices,to realize the fault segment location.Then,the time difference matrix is used to determine the traveling wave velocity,which,combined with the double-ended traveling wave location,enables accurate fault location.
基金supported by State Grid Science and Technology Project:Research on Key Protection Technologies for New-type Urban Distribution Network with Controllable Sources and Loads(5100-201913019A-0-0-00).
文摘In this paper,a fault location method for the petal-shaped distribution network(PSDN)with inverter-interfaced distributed generators(IIDGs)is proposed to shorten the time of manual inspection.In order to calculate the fault position,the closed-loop structure of the PSDN is skillfully exploited,and the common control strategies of IIDGs are considered.For asymmetrical faults,a fault line identification formula based on the negative-sequence current phase differences is presented,and a fault location formula only utilizing the negative-sequence current amplitudes is derived to calculated the fault position.For symmetrical faults,the positive-sequence current at both ends of lines and the current output from IIDGs are used to identify the fault line,and the positive-sequence current on multiple lines are used to pinpoint the fault position.In this method,corresponding current phasors are separated into amplitudes and phases to satisfy the limitation of communication level.The simulation results show that the error is generally less than 1%,and the accuracy of the proposed method is not affected by the fault type,fault position,fault resistance,load current,and the IIDG penetration.
基金supported in part by National Science Foundation of China(No.51707117)。
文摘The single-line-to-ground faults with line breaks(SLGFs-LBs)occur more and more frequently in distribution networks and can cause major safety accidents.It is difficult to distinguish the single-line-to-ground faults(SLGFs)in resonant grounding systems and ungrounding systems due to the same electrical characteristics on the source side and uncertain operation conditions of distribution networks.This paper proposes a method for distinguishing SLGFs-LBs and SLGFs.First,the source-side and load-side voltage characteristics of SLGFs and SLGFs-LBs are analyzed,and the phase difference between the voltages of the fault phase and non-fault phase on the load side is selected as the identification criterion.Phasor measurement units(PMUs)are selected as measuring devices.Then,the effects of operation conditions and external devices in distribution networks on the proposed method are discussed,and the phase errors caused by them are calculated to correct the identification method.Finally,the field testing and simulation experiments are conducted to verify the effectiveness and robustness of the proposed method.
基金the Key Program of the Chinese Academy of Sciences under Grant QYZDJ-SSW-JSC025in part by the National Natural Science Foundation of China under Grant 51721005,and in part by the Chinese Scholarship Council(CSC).
文摘Identification of faulty feeders in resonant grounding distribution networks remains a significant challenge dueto the weak fault current and complicated working conditions.In this paper, we present a deep learning-based multi-labelclassification framework to reliably distinguish the faulty feeder.Three different neural networks (NNs) including the multilayerperceptron, one-dimensional convolutional neural network (1DCNN), and 2D CNN are built. However, the labeled data maybe difficult to obtain in the actual environment. We use thesimplified simulation model based on a full-scale test field (FSTF)to obtain sufficient labeled source data. Being different frommost learning-based methods, assuming that the distribution ofsource domain and target domain is identical, we propose asamples-based transfer learning method to improve the domainadaptation by using samples in the source domain with properweights. The TrAdaBoost algorithm is adopted to update theweights of each sample. The recorded data obtained in the FSTFare utilized to test the domain adaptability. According to ourvalidation and testing, the validation accuracies are high whenthere is sufficient labeled data for training the proposed NNs.The proposed 2D CNN has the best domain adaptability. TheTrAdaBoost algorithm can help the NNs to train an efficientclassifier that has better domain adaptation. It has been thereforeconcluded that the proposed method, especially the 2D CNN, issuitable for actual distribution networks.