An exoskeleton force feedback dataglove is developed, which uses the pneumatic artificial muscles as actuators. On the basis of the simplified hand model, the motion equation is deduced according to the theory of Dena...An exoskeleton force feedback dataglove is developed, which uses the pneumatic artificial muscles as actuators. On the basis of the simplified hand model, the motion equation is deduced according to the theory of Denavit-Hartenberg. The model of the equivalent contact forces exerted by the object on the finger is proposed. By the principle of virtual work, the static equilibrium of finger is established. The force Jacobian matrix of finger is calculated, and then the joint torques of the finger when grasping objects are obtained. The theory and structure of the force feedback datagolve are introduced. Based on the theory of motion stabilization of four-bar linkage, the flexion angles of joints are measured. The torques on finger joints caused by the output forces of pneumatic artificial muscles are calculated. The output forces of pneumatic artificial muscle, whose values are controlled by its inner pressure, can be calculated by the joint torques of the finger when grasping objects. The arms of force, driving torques and the needed output forces of pneumatic muscle are calculated for each joint of the index finger. The criterion of output force of pneumatic muscle is given.展开更多
When a feedback system has components described by non-rational transfer functions, a standard practice in designing such a system is to replace the non-rational functions with rational approximants and then carry out...When a feedback system has components described by non-rational transfer functions, a standard practice in designing such a system is to replace the non-rational functions with rational approximants and then carry out the design with the approximants by means of a method that copes with rational systems. In order to ensure that the design carried out with the approximants still provides satisfactory results for the original system, a criterion of approximation should be explicitly taken into account in the design formulation. This paper derives such a criterion for multi-input multi-output(MIMO) feedback systems whose design objective is to ensure that the absolute values of every error and every controller output components always stay within prescribed bounds whenever the inputs satisfy certain bounding conditions. The obtained criterion generalizes a known result which was derived for single-input single-output(SISO) systems; furthermore, for a given rational approximant matrix, it is expressed as a set of inequalities that can be solved in practice. Finally, a controller for a binary distillation column is designed by using the criterion in conjunction with the method of inequalities. The numerical results clearly demonstrate that the usefulness of the criterion in obtaining a design solution for the original system.展开更多
基金This project is supported by National Natural Science Foundation of China(No.50375034).
文摘An exoskeleton force feedback dataglove is developed, which uses the pneumatic artificial muscles as actuators. On the basis of the simplified hand model, the motion equation is deduced according to the theory of Denavit-Hartenberg. The model of the equivalent contact forces exerted by the object on the finger is proposed. By the principle of virtual work, the static equilibrium of finger is established. The force Jacobian matrix of finger is calculated, and then the joint torques of the finger when grasping objects are obtained. The theory and structure of the force feedback datagolve are introduced. Based on the theory of motion stabilization of four-bar linkage, the flexion angles of joints are measured. The torques on finger joints caused by the output forces of pneumatic artificial muscles are calculated. The output forces of pneumatic artificial muscle, whose values are controlled by its inner pressure, can be calculated by the joint torques of the finger when grasping objects. The arms of force, driving torques and the needed output forces of pneumatic muscle are calculated for each joint of the index finger. The criterion of output force of pneumatic muscle is given.
基金financial support from the honour program of the Department of Electrical Engineering,Faculty of Engineering,Chulalongkorn University
文摘When a feedback system has components described by non-rational transfer functions, a standard practice in designing such a system is to replace the non-rational functions with rational approximants and then carry out the design with the approximants by means of a method that copes with rational systems. In order to ensure that the design carried out with the approximants still provides satisfactory results for the original system, a criterion of approximation should be explicitly taken into account in the design formulation. This paper derives such a criterion for multi-input multi-output(MIMO) feedback systems whose design objective is to ensure that the absolute values of every error and every controller output components always stay within prescribed bounds whenever the inputs satisfy certain bounding conditions. The obtained criterion generalizes a known result which was derived for single-input single-output(SISO) systems; furthermore, for a given rational approximant matrix, it is expressed as a set of inequalities that can be solved in practice. Finally, a controller for a binary distillation column is designed by using the criterion in conjunction with the method of inequalities. The numerical results clearly demonstrate that the usefulness of the criterion in obtaining a design solution for the original system.