期刊文献+
共找到23,450篇文章
< 1 2 250 >
每页显示 20 50 100
Effect of a cervical collar on optic nerve sheath diameter in trauma patients
1
作者 Mümin Murat Yazici Ozcan Yavasi 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第2期126-130,共5页
BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference ... BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference in optic nerve sheath diameter(ONSD)between patients with and without a cervical collar using computed tomography(CT).METHODS:This was a single-center,retrospective study examining trauma patients who presented to the emergency department between January 1,2021,and December 31,2021.The ONSD on brain CT of the trauma patients was measured and analyzed to determine whether there was a difference between the ONSD with and without the cervical collar.RESULTS:The study population consisted of 169 patients.On CT imaging of patients with(n=66)and without(n=103)cervical collars,the mean ONSD in the axial plane were 5.43±0.50 mm and 5.04±0.46 mm respectively for the right eye and 5.50±0.52 mm and 5.11±0.46 mm respectively for the left eye.The results revealed an association between the presence of a cervical collar and the mean ONSD,which was statistically significant(P<0.001)for both the right and left eyes.CONCLUSION:A cervical collar may be associated with increased ONSD.The effect of this increase in the ONSD on clinical outcomes needs to be investigated,and the actual need for cervical collar in the emergency department should be evaluated on a case-by-case basis. 展开更多
关键词 Optic nerve sheath diameter Computed tomography TRAUMA Emergency medicine
下载PDF
Added value of ratio of cross diameters of the appendix in ultrasound diagnosis of acute appendicitis
2
作者 Feng-Wa Gu Si-Ze Wu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期21-28,共8页
BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate wheth... BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate whether combining the ratio of the cross diameters(RATIO)of the appendix with MOD of the appendix can enhance the diagnostic performance of acute appendicitis.METHODS A retrospective study was conducted,and medical records of 233 patients with acute appendicitis and 112 patients with a normal appendix were reviewed.The MOD and RATIO of the appendix were calculated and tested for their diagnostic performance of acute appendicitis,both individually and in combination.RESULTS The RATIO for a normal appendix was 1.32±0.16,while for acute appendicitis it was 1.09±0.07.The cut-off value for RATIO was determined to be≤1.18.The area under the receiver operating characteristic curve(AUC)for diagnosing acute appendicitis using RATIO≤1.18 and MOD>6 mm was 0.870 and 0.652,respectively.There was a significant difference in AUC between RATIO≤1.18 and MOD>6 mm(P<0.0001).When comparing the combination of RATIO≤1.18 and MOD>6 mm with MOD>6 mm alone,the combination showed increased specificity,positive predictive value(PPV),and AUC.However,the sensitivity and negative predictive value decreased.CONCLUSION Combining RATIO of the appendix≤1.18 and MOD>6 mm can significantly improve the specificity,PPV,and AUC in the US diagnosis of acute appendicitis. 展开更多
关键词 Acute appendicitis diameter RATIO Diagnosis ULTRASOUND
下载PDF
Simulation of Haloxylon Ammodendron Stand Basic Diameter Structure Based on Fuzzy Distribution Function
3
作者 Shaohua Wang Chuanqiang Liu Ting Yang 《Agricultural Sciences》 2024年第1期132-145,共14页
Based on the investigation data of 12 Haloxylon ammodendron plots in the south edge of Gurbantunggut Desert, Fuzzy distribution was introduced into the study of Haloxylon ammodendron base diameter structure fitting ac... Based on the investigation data of 12 Haloxylon ammodendron plots in the south edge of Gurbantunggut Desert, Fuzzy distribution was introduced into the study of Haloxylon ammodendron base diameter structure fitting according to the consistency between the characteristics of Fuzzy distribution function and the distribution series of cumulative percentage of stand base diameter, and the fitting precision and effect of Fuzzy distribution function were discussed. The root mean square error RMSE and determination coefficient R<sup>2</sup> values showed that Fuzzy-Γ<sub>1</sub>, Fuzzy-Γ<sub>2</sub>, Fuzzy-Γ<sub>3</sub>, Fuzzy-Γ<sub>4</sub> had good fitting performance, among which Fuzzy-Γ<sub>1</sub> had relatively high fitting precision, and its parameters were closely related to stand age and density, Fuzzy-Γ<sub>2</sub> distribution function was the second, and Fuzzy-Γ<sub>4</sub> distribution function had the worst fitting effect. By introducing a parameter c from the similarity of four distribution function formulas, a generalized Fuzzy distribution function Fuzzy-Γ<sub>5</sub> is obtained. This function shows the highest fitting accuracy. Most of the values of parameter c are near 1 or 2, which shows that the diameter distribution is mainly approximate to Fuzzy-Γ<sub>1</sub> and Fuzzy-Γ<sub>2</sub>. 展开更多
关键词 Fuzzy Distribution Function Haloxylon Ammodendron Base diameter Distribution Stand Factor
下载PDF
Increased retinal venule diameter as a prognostic indicator for recurrent cerebrovascular events:a prospective observational study
4
作者 Ying Zhao Dawei Dong +5 位作者 Ding Yan Bing Yang Weirong Gui Man Ke Anding Xu Zefeng Tan 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第5期1156-1160,共5页
Microvasculature of the retina is considered an alternative marker of cerebral vascular risk in healthy populations.However,the ability of retinal vasculature changes,specifically focusing on retinal vessel diameter,t... Microvasculature of the retina is considered an alternative marker of cerebral vascular risk in healthy populations.However,the ability of retinal vasculature changes,specifically focusing on retinal vessel diameter,to predict the recurrence of cerebrovascular events in patients with ischemic stroke has not been determined comprehensively.While previous studies have shown a link between retinal vessel diameter and recurrent cerebrovascular events,they have not incorporated this information into a predictive model.Therefore,this study aimed to investigate the relationship between retinal vessel diameter and subsequent cerebrovascular events in patients with acute ischemic stroke.Additionally,we sought to establish a predictive model by combining retinal veessel diameter with traditional risk factors.We performed a prospective observational study of 141 patients with acute ischemic stroke who were admitted to the First Affiliated Hospital of Jinan University.All of these patients underwent digital retinal imaging within 72 hours of admission and were followed up for 3 years.We found that,after adjusting for related risk factors,patients with acute ischemic stroke with mean arteriolar diameter within 0.5-1.0 disc diameters of the disc margin(MAD_(0.5-1.0DD))of≥74.14μm and mean venular diameter within 0.5-1.0 disc diameters of the disc margin(MVD_(0.5-1.0DD))of≥83.91μm tended to experience recurrent cerebrovascular events.We established three multivariate Cox proportional hazard regression models:model 1 included traditional risk factors,model 2 added MAD_(0.5-1.0DD)to model 1,and model 3 added MVD0.5-1.0DD to model 1.Model 3 had the greatest potential to predict subsequent cerebrovascular events,followed by model 2,and finally model 1.These findings indicate that combining retinal venular or arteriolar diameter with traditional risk factors could improve the prediction of recurrent cerebrovascular events in patients with acute ischemic stroke,and that retinal imaging could be a useful and non-invasive method for identifying high-risk patients who require closer monitoring and more aggressive management. 展开更多
关键词 acute ischemic stroke arteriolar cerebrovascular events diameter digital retinal imaging MICROVASCULATURE prediction RECURRENT RETINA venular
下载PDF
One-year results for myopia control of orthokeratology with different back optic zone diameters: a randomized trial using a novel multispectral-based topographer
5
作者 Wen-Ting Tang Xiang-Ning Luo +4 位作者 Wen-Jing Zhao Jia Liao Xin-Yue Xu Hui-Dan Zhang Li Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期324-330,共7页
AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in ... AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR. 展开更多
关键词 relative peripheral refraction ORTHOKERATOLOGY MYOPIA back optic zone diameter axial length multispectral refractive topography
下载PDF
Study of the Characteristics of Large-Diameter Iron Bars Obtained by Rolling at the ODHAV Foundry in the Republic of Guinea
6
作者 Alpha Issa Diallo Jean Ahmadou Kourouma +3 位作者 Adama Moussa Sakho Younoussa Moussa Baldé Mamadou Madaniou Sow Alexandre Lucien Richard 《Journal of Materials Science and Chemical Engineering》 2024年第6期43-54,共12页
This work consists of evaluating the quality of the mechanical parameters of large-diameter steels, i.e. 20, 25, 28 and 32, through a process of recycling scrap metal that fills garages, rubbish dumps, gutters and oth... This work consists of evaluating the quality of the mechanical parameters of large-diameter steels, i.e. 20, 25, 28 and 32, through a process of recycling scrap metal that fills garages, rubbish dumps, gutters and other abandoned sites, as well as imported concrete reinforcing steel sold in the Republic of Guinea. To carry out this important work, a number of mechanical tensile and bending tests and a microscopic analysis combining two devices, an electron microscope and a photographic camera, were carried out. The samples were taken from sampling areas in the major communes of Conakry, namely: Casse Sonfonia, Matoto and Kagbélen. The tensile strength values of the large dimensions 20, 25, 28 and 32 are given in the tables. 展开更多
关键词 Recycled Scrap Large diameter ROLLING Tensile Testing BENDING
下载PDF
Sub-stand diameter distribution types vary along an old-growth Douglas-fir chronosequence into the horizontal diversification development stage 被引量:1
7
作者 JeriLynn E.Peck Eric K.Zenner 《Journal of Forestry Research》 SCIE CAS CSCD 2023年第2期415-424,共10页
Managing mature Douglas-fir[Pseudotsuga menziesii(Mirb.)Franco]stands to emulate the structural complexity of natural old-growth forest requires identifying structural targets at the sub-stand level at which neighborh... Managing mature Douglas-fir[Pseudotsuga menziesii(Mirb.)Franco]stands to emulate the structural complexity of natural old-growth forest requires identifying structural targets at the sub-stand level at which neighborhood dynamics and patchy disturbance shape structure.We therefore sought to describe the archetypal shapes of predominant sub-stand diameter distribution types(DDTs)observed in natural tree neighborhoods in stands comprising a chronosequence(ca.120-450+yrs)encompassing mature,vertical diversification,and horizontal diversification development stages.The ten 1.0 ha stands are located in the southcentral Oregon Cascades,USA.Building on the known spatial position of each tree,natural tree neighborhoods were identified using the floating neighborhood approach based on spatial tessellation connecting neighboring trees at the first-(mean 61 m2)through fifth-(mean 2058 m2)order scales.Cluster analysis was then used to objectively identify the most predominant DDTs among the relative tree size distributions observed in the trans-scale neighborhoods within each stand.Repeated measures regression was used to classify each DDT to one of six observed archetypal shapes:negative exponential,unimodal,rotated sigmoid,bimodal,concave,or multi-modal.Only three of the 81 observed DDTs deviated by<10%from the stand average,while every stand had at least one DDT that deviated by>50%(maximum 83%).Within each stand,five to ten predominant DDTs were observed,which deviated from the stand average by 30-48%and were characterized by two to five different archetypal shapes.Consequently,in some stands the majority of tree neighborhoods were best characterized by a different shape from that assigned at the stand level.Deviation from the stand average increased from the youngest stand in the mature development stage through the middle stands in the vertical diversification stage to the oldest stands in the horizontal diversification stage.The complexity of DDT shapes tended to increase along the chronosequence(from negative exponential and uniform toward concave and multi-modal),with shape richness highest mid-sequence and evenness peaking in the oldest stands.The high diversity of sub-stand structural complexity reduces the utility of standlevel diameter distributions as old-growth restoration targets.However,the presence in early-sequence stands of sub-stand diameter distributions common to later-sequence stands may facilitate active management at the neighborhood level to promote future old-growth condition.Restoration of substand diameter structures would likely require combining spatial perspectives,such as by augmenting tree-level croptree management with diameter distribution targets for the resulting tree neighborhoods. 展开更多
关键词 diameter distribution type Floating neighborhood Restoration silviculture Small-scale Structural complexity
下载PDF
Alternative expressions for stand diameter in complex forests 被引量:1
8
作者 Mark J.Ducey John A.Kershaw Jr. 《Forest Ecosystems》 SCIE CSCD 2023年第3期328-336,共9页
Quadratic mean diameter is the most frequently reported descriptor of the diameter distribution of forests.As such,it is often used as an indicator of forest stand structure,developmental stage,and ecological and econ... Quadratic mean diameter is the most frequently reported descriptor of the diameter distribution of forests.As such,it is often used as an indicator of forest stand structure,developmental stage,and ecological and economic potential.However,quadratic mean diameter can be heavily influenced by the presence or absence of large numbers of small stems in lower canopy strata,and it is also sensitive to left-truncation of the diameter distribution,making its interpretation across inventories with different protocols challenging.Here,we examine three alternative expressions of stand diameter:the arithmetic and quadratic mean diameter of the thickest 100 trees per hectare,and the basal area-weighted mean diameter.Using data from the United States Forest Inventory and Analysis program for New York and New England,these alternative expressions showed closer correlation with multiple stand structural variables than did quadratic mean diameter,including merchantable cubic and board foot volume per hectare,aboveground live tree carbon per hectare,and total number of live and dead standing trees greater than 40 cm diameter at breast height per hectare(previously proposed as an index of old-growth structure).Arithmetic and quadratic mean diameter of the thickest 100 trees per hectare showed nearly identical performance,and the strongest correlations across the board.We develop closed-form expressions for these variables when the diameter distribution is a Weibull,and illustrate their behavior relative to quadratic mean diameter for that situation.While the reasons for prevalence of quadratic mean diameter as an indicator remain valid,we suggest that these alternative measures should be more widely reported and analyzed to give a more informative depiction of stand structure and development in complex forests. 展开更多
关键词 Forest structure diameter at breast height Weibull distribution
下载PDF
Measuring tree stem diameters and straightness with depth-image computer vision
9
作者 Hoang Tran Keith Woeste +2 位作者 Bowen Li Akshat Verma Guofan Shao 《Journal of Forestry Research》 SCIE CAS CSCD 2023年第5期1395-1405,共11页
Current techniques of forest inventory rely on manual measurements and are slow and labor intensive.Recent developments in computer vision and depth sensing can produce accurate measurement data at significantly reduc... Current techniques of forest inventory rely on manual measurements and are slow and labor intensive.Recent developments in computer vision and depth sensing can produce accurate measurement data at significantly reduced time and labor costs.We developed the ForSense system to measure the diameters of trees at various points along the stem as well as stem straightness.Time use,mean absolute error(MAE),and root mean squared error(RMSE)metrics were used to compare the system against manual methods,and to compare the system against itself(reproducibility).Depth-derived diameter measurements of the stems at the heights of 0.3,1.4,and 2.7 m achieved RMSE of 1.7,1.5,and 2.7 cm,respectively.The ForSense system produced straightness measurement data that was highly correlated with straightness ratings by trained foresters.The ForSense system was also consistent,achieving sub-centimeter diameter difference with subsequent measures and less than 4%difference in straightness value between runs.This method of forest inventory,which is based on depth-image computer vision,is time efficient compared to manual methods and less computationally and technologically intensive compared to Structure-from-Motion(SFM)photogrammetry and ground-based LiDAR or terrestrial laser scanning(TLS). 展开更多
关键词 Forest inventory Depth sensing Computer vision Tree diameter Stem straightness Trunk volume
下载PDF
Accuracy of Trans-Cerebellar Diameter and Placental Thickness in Third Trimesteric Pregnant Women for Calculation of Gestational Age: A Cross Sectional Study
10
作者 Alaa Sayed Hassanin Hassan Tawfik Khairy +1 位作者 Aya Tullah Abd Elfatah Elshaer Sarah Safwat 《Open Journal of Obstetrics and Gynecology》 CAS 2023年第2期303-314,共12页
Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnanc... Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnancy. Objective: The aim of the study was to assess whether the trans-cerebellar diameter, placental thickness or combining both of them is more accurate for assessment of gestational age in the 3<sup>rd</sup> trimester of pregnancy. Patients and Methods: This is a cross sectional study conducted at outpatient Clinic and Obstetric ward, Ain Shams University Maternity Hospital, over a period of six months from March 2019 to September 2019. One hundred pregnant women were recruited according to inclusion criteria either from outpatient clinic or were admitted in obstetric ward Ain Shams Maternity Hospital to find out the most accurate fetal biometric measurement in the third trimester either trans-cerebellar diameter placental thickness or both compared to reliable LMP (last menstrual period) dates confirmed by crown rump length (CRL) in the first trimester. Results: Trans-cerebellar diameter mean ± SD was 46.0 ± 3.5 with range 38.2 - 51.7. The mean of placental thickness was 39.6 ± 7.1 with range 22.8 - 54.3. Placental thickness had highest determination (0.813) for last menstrual period followed by trans-cerebellar diameter (0.802). Combining trans-cerebellar diameter and placental thickness increased determination (0.902) for last menstrual period. Conclusion: Combined use of trans-cerebellar diameter and placental thickness in the third trimester of pregnancy is a reliable indicator for gestational age in women whose last menstrual period is unreliable or unknown, but placental thickness had higher accuracy than trans-cerebellar diameter. 展开更多
关键词 Accuracy of Trans-Cerebellar diameter Placental Thickness Third Tri-mesteric Pregnant Women Gestational Age
下载PDF
Diameter distributions in Pinus sylvestris L.stands:evaluating modelling approaches including a machine learning technique
11
作者 Şükrü Teoman Güner Maria J.Diamantopoulou Ramazan Özçelik 《Journal of Forestry Research》 SCIE CAS CSCD 2023年第6期1829-1842,共14页
The diameter distribution of trees in a stand provides the basis for determining the stand’s ecological and economic value,its structure and stability and appropriate management practices.Scots pine(Pinus sylvestris ... The diameter distribution of trees in a stand provides the basis for determining the stand’s ecological and economic value,its structure and stability and appropriate management practices.Scots pine(Pinus sylvestris L.)is one of the most common and important conifers in Turkey,so a well-planned management schedule is critical.Diameter distribution models to accurately describe the stand structure help improve management strategies,but developing reliable models requires a deep understanding of the growth,output and constraints of the forests.The most important information derived by diameter distribution models is primary data on horizontal stand structure for each diameter class of trees:basal area and volume per unit area.These predictions are required to estimate the range of products and predicted volume and yield from a forest stand.Here,to construct an accurate,reliable diameter distribution model for natural Scots pine stands in the Türkmen Mountain region,we used Johnson’s SBdistribution to represent the empirical diameter distributions of the stands using ground-based measurements from 55 sample plots that included1219 trees in natural distribution zones of the forests.As an alternative,nonparametric approach,which does not require any predefined function,an artificial intelligence model was constructed based on support vector machine methodology.An error index was calculated to evaluate the results.Overall,both Johnson’s SB probability density function with a three-parameter recovery approach and the support vector regression methodology provided reliable estimates of the diameter distribution of these stands. 展开更多
关键词 diameter distribution Johnson’s S_(B) Support vector regression Scots pine Türkmen mountains
下载PDF
Bedside ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure in nontraumatic neurocritically ill patients
12
作者 Madhura Bhide Omender Singh +1 位作者 Deven Juneja Amit Goel 《World Journal of Critical Care Medicine》 2023年第1期10-17,共8页
BACKGROUND Delay in treatment of raised intracranial pressure(ICP)leads to poor clinical outcomes.Optic nerve sheath diameter(ONSD)by ultrasonography(US-ONSD)has shown good accuracy in traumatic brain injury and neuro... BACKGROUND Delay in treatment of raised intracranial pressure(ICP)leads to poor clinical outcomes.Optic nerve sheath diameter(ONSD)by ultrasonography(US-ONSD)has shown good accuracy in traumatic brain injury and neurosurgical patients to diagnose raised ICP.However,there is a dearth of data in neuro-medical intensive care unit(ICU)where the spectrum of disease is different.AIM To validate the diagnostic accuracy of ONSD in non-traumatic neuro-critically ill patients.METHODS We prospectively enrolled 114 patients who had clinically suspected raised ICP due to non-traumatic causes admitted in neuro-medical ICU.US-ONSD was performed according to ALARA principles.A cut-off more than 5.7 mm was taken as significantly raised.Raised ONSD was corelated with raised ICP on radiological imaging.Clinical history,general and systemic examination findings,SOFA and APACHE 2 score and patient outcomes were recorded.RESULTS There was significant association between raised ONSD and raised ICP on imaging(P<0.001).The sensitivity,specificity,positive and negative predictive value at this cut-off was 77.55%,89.06%,84.44% and 83.82% respectively.The positive and negative likelihood ratio was 7.09 and 0.25.The area under the receiver operating characteristic curves was 0.844.Using Youden’s index the best cut off value for ONSD was 5.75 mm.Raised ONSD was associated with lower age(P=0.007),poorer Glasgow Coma Scale(P=0.009)and greater need for surgical intervention(P=0.006)whereas no statistically significant association was found between raised ONSD and SOFA score,APACHE II score or ICU mortality.Our limitations were that it was a single centre study and we did not perform serial measurements or ONSD pre-and post-treatment or procedures for raised ICP.CONCLUSION ONSD can be used as a screening a test to detect raised ICP in a medical ICU and as a trigger to initiate further management of raised ICP.ONSD can be beneficial in ruling out a diagnosis in a low-prevalence population and rule in a diagnosis in a high-prevalence population. 展开更多
关键词 Intracranial pressure Intensive care unit Neuro-critical care Optic nerve sheath diameter ULTRASONOGRAPHY
下载PDF
大直径盾构隧道成型质量巡检方法研究 被引量:1
13
作者 赵先琼 邓凯 +2 位作者 张亚洲 马英博 夏毅敏 《工程科学学报》 EI CSCD 北大核心 2024年第2期365-375,共11页
针对因工业应用成本限制,中、小盾构隧道成型质量无损检测技术迁移至大直径盾构隧道时精度、速度折损严重的问题,以巡检车为载体,集成二维激光扫描仪、编码器和计算机等设备,研制了大盾构隧道成型质量巡检车,并提出一种基于数字图像的... 针对因工业应用成本限制,中、小盾构隧道成型质量无损检测技术迁移至大直径盾构隧道时精度、速度折损严重的问题,以巡检车为载体,集成二维激光扫描仪、编码器和计算机等设备,研制了大盾构隧道成型质量巡检车,并提出一种基于数字图像的盾构质量非对称巡检方法.分析大直径盾构的施工环境,滤除地面、车体点云,并采用邻域向量法提取中轴线,建立隧道中心坐标系.偏心布置巡检路线,按照点云密度将采样点云分为稠密侧和稀疏侧点云,通过不同方法实现对管片接缝特征的拾取:将稠密侧点云绕中轴线展开为二维灰度图像,并通过缩放、归一化、梯度阈值分割等方法实现接缝图像分割;基于直线方程对接缝进行分类,结合管片结构、布置点位,推导出稀疏侧接缝与稠密侧接缝的线性分布公式,间接拾取稀疏侧接缝.根据接缝特征点计算两侧管片边缘点云簇,计算管片错台量;剔除接缝点云簇,使用最小二乘法拟合隧道点云,计算隧道椭圆度.最后在某大直径盾构隧道进行巡检试验,试验结果表明:成型质量巡检车在十四米盾构隧道中巡检速度为3 km·h-1,与传统方法的错台量检测偏差小于2 mm,椭圆度检测偏差小于0.1%,可以满足大直径盾构隧道成型质量巡检的高速度、高精度、低成本需求. 展开更多
关键词 大直径盾构隧道 激光扫描 阈值分割 错台检测 变形检测
下载PDF
3D MERGE与3D SPACE STIR序列在腰椎间盘突出症检查中的应用比较 被引量:1
14
作者 李兰 殷小丹 +2 位作者 李旭雪 吴海燕 张滔 《中国医学物理学杂志》 CSCD 2024年第1期27-31,共5页
目的:对比三维多回波恢复梯度回波(3D MERGE)、三维可变反转角快速自旋回波(3D SPACE STIR)序列在腰椎间盘突出症(LDH)检查中的应用效果。方法:选择2020年1月~2022年11月收治的135例LDH患者,回顾性分析患者临床和磁共振成像(MRI)资料,... 目的:对比三维多回波恢复梯度回波(3D MERGE)、三维可变反转角快速自旋回波(3D SPACE STIR)序列在腰椎间盘突出症(LDH)检查中的应用效果。方法:选择2020年1月~2022年11月收治的135例LDH患者,回顾性分析患者临床和磁共振成像(MRI)资料,所有患者均接受常规MRI扫描及3D MERGE、3D SPACE STIR序列扫描,对比3D MERGE、3D SPACE STIR序列测量神经根直径的一致性,评价两种序列的图像质量参数[信噪比(SNR)、对比噪声比(CNR)]、图像清晰度评分。结果:3D MERGE和3D SPACE STIR序列测量的L3~S1神经根直径比较差异无统计学意义(P>0.05),且两组序列测量的L3、L4、L5和S1直径均显示出较高相关性(r=0.957,0.986,0.975,0.972,P<0.05);3D MERGE序列的SNR及CNR均高于3D SPACE STIR序列,神经根显示分级、图像清晰度评分优于3D SPACE STIR序列,差异有统计学意义(P<0.05)。结论:3D MERGE、3D SPACE STIR序列在LDH神经根直径测量中具有极高一致性,3D MERGE序列较3D SPACE STIR序列能够更清晰显示神经跟的解剖形态,图像质量更好。 展开更多
关键词 腰椎间盘突出症 3D MERGE 3D SPACE STIR 神经根直径 图像质量
下载PDF
气体流量和喷嘴直径对鼓泡塔内气泡大小和形状分布的影响
15
作者 闫红杰 张河杨 +2 位作者 刘柳 Thomas ZIEGENHEIN 周萍 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2024年第5期1710-1720,共11页
通过高速摄影结合图像处理算法,研究气体流量和喷嘴直径对气泡尺寸和纵横比分布的影响。结果表明,在所有喷嘴直径下,气泡当量直径的概率密度呈现双峰分布,其中第一个峰值接近直径为1.5~2 mm的小气泡区域,另一个峰值位于较大的气泡区域... 通过高速摄影结合图像处理算法,研究气体流量和喷嘴直径对气泡尺寸和纵横比分布的影响。结果表明,在所有喷嘴直径下,气泡当量直径的概率密度呈现双峰分布,其中第一个峰值接近直径为1.5~2 mm的小气泡区域,另一个峰值位于较大的气泡区域。将气体流量从0.1 L/min增加到0.2 L/min会导致大气泡的概率密度更高,表明气泡聚并现象普遍存在。当气体流量增加至1.2L/min时,峰值对应的气泡直径变小,并且气泡破裂占主导地位。对于直径为1~2 mm的气泡,形状受气体流量的影响较小,而3~9 mm的气泡在所有气体流量下气泡纵横比概率密度分布的峰值均位于纵横比E=0.5处。Iguchi和Chihara提出的模型能更好地预测气泡脱离直径随气体流量的增大的变化。 展开更多
关键词 气泡尺寸分布 气泡直径 气泡纵横比 气体流量 喷嘴直径 鼓泡塔
下载PDF
大直径盾构隧道纵向刚度增强措施研究 被引量:1
16
作者 叶飞 李思翰 +2 位作者 刘畅 温小宝 韩兴博 《地下空间与工程学报》 CSCD 北大核心 2024年第3期959-968,共10页
为研究不同环缝接头结构对盾构隧道纵向刚度的增强效果,采用等效连续化模型计算得到断面直径对隧道纵向拉压、纵向抗剪和纵向抗弯刚度的影响规律,将隧道纵向刚度增强措施与管片环缝接头结构相联系,采用数值模拟深入探究了9种环缝接头结... 为研究不同环缝接头结构对盾构隧道纵向刚度的增强效果,采用等效连续化模型计算得到断面直径对隧道纵向拉压、纵向抗剪和纵向抗弯刚度的影响规律,将隧道纵向刚度增强措施与管片环缝接头结构相联系,采用数值模拟深入探究了9种环缝接头结构的力学性能,对比得到增强隧道纵向刚度效果最优的环缝接头结构。结果表明:直径对纵向拉压和纵向抗弯刚度影响较小,对纵向抗剪刚度影响较大;环缝接头刚度增强措施能够显著减小管片位移,提高隧道纵向刚度,提升效果为:斜螺栓>弯螺栓,定位榫>剪力销>凹凸榫;螺栓型式和纵向刚度增强措施均对螺栓最大剪切应力有较大影响,竖向荷载下受螺栓型式影响较大,水平向荷载下受管片环缝接头刚度增强措施影响较大;结合经济性和有效性,当接头螺栓为弯螺栓时,设置定位榫是一种相对较优的选择。 展开更多
关键词 大直径盾构 纵向刚度 管片环缝接头 刚度增强措施
下载PDF
不同冲击气压下煤样动态剪切强度的长径比效应 被引量:1
17
作者 王磊 陈礼鹏 +2 位作者 袁秋鹏 焦振华 刘怀谦 《岩土工程学报》 EI CAS CSCD 北大核心 2024年第1期131-139,共9页
采用Φ50mm分离式霍普金森压杆(SHPB)试验系统,开展了不同冲击气压下直径75mm,长径比分别为0.20,0.27,0.33,0.40和0.47的5组煤样的动态剪切试验,划分了煤动态剪应力时程曲线的阶段,探讨了冲击气压对煤样动态剪切强度的影响,分析了煤样... 采用Φ50mm分离式霍普金森压杆(SHPB)试验系统,开展了不同冲击气压下直径75mm,长径比分别为0.20,0.27,0.33,0.40和0.47的5组煤样的动态剪切试验,划分了煤动态剪应力时程曲线的阶段,探讨了冲击气压对煤样动态剪切强度的影响,分析了煤样动态剪切强度和加载率的长径比效应,并建立了长径比效应理论模型。研究结果表明:①煤样动态剪应力时程曲线可分为应力初始上升、应力线性增长、应力缓慢上升和应力下降4个阶段;②煤样动态剪切强度与冲击气压呈正线性相关,但不同长径比下增加幅度存在差异,具体表现为:相同冲击气压增量下,煤样长径比越小,动态剪切强度的增加幅度越大;③煤样动态剪切强度和加载率均与长径比有关,在0.25,0.35 MPa较低冲击气压与0.45,0.55 MPa较高冲击气压下分别呈现出正、负长径比效应,并通过方差分析确定了长径比对其影响最小的冲击气压为0.376MPa;④建立了不同冲击气压下煤样动态剪切强度长径比效应理论模型,通过加载率效应推导出加载率长径比效应理论模型,并验证了模型的合理性和准确性。 展开更多
关键词 长径比效应 动态剪切强度 加载率 敏感性
下载PDF
月季新品种蜜月的保鲜技术研究
18
作者 许凤 赵阿香 +4 位作者 华月勇 杨秀梅 王丽花 蒋亚莲 张艺萍 《江西农业学报》 CAS 2024年第5期43-49,共7页
蜜月为云南省农业科学院花卉研究所经过多年选育出的具有自主知识产权的新优品种,花红色,高心卷瓣杯状型,抗病性强,年产量20枝/株。为了能够较好地推广该品种,选用了市售的可利鲜、花之寿及自制的保鲜剂进行保鲜试验,测定了保鲜液中的... 蜜月为云南省农业科学院花卉研究所经过多年选育出的具有自主知识产权的新优品种,花红色,高心卷瓣杯状型,抗病性强,年产量20枝/株。为了能够较好地推广该品种,选用了市售的可利鲜、花之寿及自制的保鲜剂进行保鲜试验,测定了保鲜液中的细菌含量、开花指数、花朵直径、鲜重变化率、水分平衡值、干物质含量、切花花瓣pH值、保鲜液pH值、可溶性蛋白、超氧化物歧化酶等指标。切花月季蜜月在花之寿、可利鲜保鲜液中的观赏效果较好,花朵正常开放、不萎蔫,而在清水对照和自制保鲜剂中的观赏效果一般;在清水对照和花之寿保鲜液中第5天达到最大开花指数,而可利鲜保鲜液中第6天达到最大开花指数,且开放度维持较好。对照和自制保鲜液细菌含量随着试验天数的延长而增加,抑菌效果相对其他两组保鲜液差异显著;可利鲜的抑菌效果最好,保鲜液中未检出细菌。由此可知,可利鲜仍是较好的保鲜剂,后期将对自制的保鲜剂进行改良,为后期品种推广提供保鲜技术的支撑。 展开更多
关键词 月季 蜜月 保鲜技术 开花指数 花朵直径
下载PDF
广西沃柑果实横径生长动态及模型构建
19
作者 黄其椿 汪妮娜 +13 位作者 黄燕晓 张海平 黄爱星 谭颂玥 韦正林 梁增 韦琮 韦炳安 陈亮 罗增桂 胡承孝 陈东奎 覃泽林 曾志康 《果树学报》 CAS CSCD 北大核心 2024年第4期764-776,共13页
【目的】研究广西沃柑果实横径的生长动态并构建数学模型,为提升其品质和产量提供科学依据。【方法】以沃柑为材料,于稳果后,连续两年每月1日、15日通过“定园、定点、定果、定期”的方法测量并记录广西桂南、桂中、桂北15个果园的沃柑... 【目的】研究广西沃柑果实横径的生长动态并构建数学模型,为提升其品质和产量提供科学依据。【方法】以沃柑为材料,于稳果后,连续两年每月1日、15日通过“定园、定点、定果、定期”的方法测量并记录广西桂南、桂中、桂北15个果园的沃柑横径数据,直至采收期,研究沃柑横径的变化动态,考察年终横径与各生长节点,月度横径增加值与主要气象信息的相关性并建立数学模型。【结果】各个果园最终的横径差别较大,达到极显著差异水平,多个果园的横径有待提升;对比气象数据,选定2021—2022年度的沃柑横径数据为正常年份数据,翌年1月15日果实横径平均值为69.85 mm,最高的果园达75.33 mm,最小的61.55 mm;以80、75、70、65、60、55 mm为等级,构建桂南、桂北和桂中沃柑果实横径生长动态对照表、横径月度增加值对照表;分别建立年终沃柑横径数值与各生长节点,横径月度增加值与主要月度气象信息的数学模型,年终横径与7月15日呈显著正相关,与8月15日以后呈极显著正相关,至11月1日达到极显著的0.934 0;月度增加值与降雨、温度相关系数分别为显著的0.791 8和极显著的0.879 1。【结论】广西沃柑提质增产仍存在较大空间,可结合当期横径生长对照表、定期差值对照表,科学合理安排水肥药的灌溉来进一步加速果实膨大,从而提升效益。 展开更多
关键词 柑橘 广西沃柑 果实横径 生长动态 数学模型
下载PDF
大直径钢筒圆度异常区快速检测方法
20
作者 吕伟荣 吴佳强 +4 位作者 姚帅 戚菁菁 卢倍嵘 丁时宝 甘德家 《测绘通报》 CSCD 北大核心 2024年第7期100-104,128,共6页
大直径钢筒在制作、运输、安装及运行时均可能因某些原因导致其出现一个或多个圆度异常区,以至于不满足设备验收和运行的相关要求。目前,针对大直径钢筒圆度异常的检测方法均较为复杂,并不适合快速检出。为此,本文基于三坐标测量原理,... 大直径钢筒在制作、运输、安装及运行时均可能因某些原因导致其出现一个或多个圆度异常区,以至于不满足设备验收和运行的相关要求。目前,针对大直径钢筒圆度异常的检测方法均较为复杂,并不适合快速检出。为此,本文基于三坐标测量原理,结合高精度全站仪的非接触自动测量模式,并采用Matlab编制了自动搜索程序,提出了大直径钢筒圆度异常区的快速检测方法。通过AutoCAD算例模拟和现场实测,结果表明,该检测方法不仅速度快,且可通过增加测点密度实现大幅提高检出精度,为后续修复和改进工作提供准确数据。 展开更多
关键词 大直径 钢筒 圆度 三坐标测量 非接触
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部