期刊文献+
共找到398篇文章
< 1 2 20 >
每页显示 20 50 100
Fetal Thigh Circumference versus Fetal Abdominal Subcutaneous Tissue Thickness in Prediction of Fetal Weight in Term Pregnant Women
1
作者 Mohamed El-Mandooh Aya Hassan Sarah Safwat 《Open Journal of Obstetrics and Gynecology》 2023年第9期1580-1594,共15页
Background: Fetal weight estimation by ultrasound is an important factor in obstetrics;it is directly related to the gestational age which helps to plan the mode of delivery and labor management. Objective: to compare... Background: Fetal weight estimation by ultrasound is an important factor in obstetrics;it is directly related to the gestational age which helps to plan the mode of delivery and labor management. Objective: to compare between fetal thigh circumference (TC) and abdominal subcutaneous tissue thickness (SCT) in estimating birthweight in term pregnant women. Patients and Methods: This prospective cohort study was conducted at outpatient clinic or emergency room, Obstetrics and Gynecology Department, Faculty of Medicine, Ain Shams University Maternity Hospitals from March 2022 until May 2023. During this study, 100 term pregnant females with gestational age 37 - 40 weeks attended El Demerdash Maternity Hospital and scheduled for delivery either at outpatient clinic or emergency room were enrolled, after consenting each of them. Basic fetal biometry was performed by an expert and professional medical personnel to ensure the accuracy of examination results. Fetal abdominal subcutaneous thickness and fetal thigh circumference were measured for assessment of gestational age and correlated with actual fetal body weight. In the current study, three formulas;Hadlock, Vintzileos’ and SCT formula were correlated with actual fetal body weight after birth. Results: The present study revealed that TC formula is closer to the actual birth weight, followed by Hadlock formula, while the SCT formula is the furthest from it. Conclusion: To increase the accuracy of birth estimations, regular ultrasound examinations should include fetal thigh circumference measurement. 展开更多
关键词 fetal Thigh Circumference fetal Abdominal Subcutaneous Thickness fetal weight Term Pregnancy
下载PDF
Assessment of Used Formulae for Sonographic Estimation of Fetal Weight in Sudanese Population 被引量:1
2
作者 Caroline Edward Ayad Ahmed Abdelrahim Mohammed Ibrahim +3 位作者 Mohamed Elfadil Mohamed Garelnabi Bushra Hussein Ahmed Elsafi Ahmed Abdalla Mohammed Ahmed Elshiekh Saleem 《Open Journal of Radiology》 2016年第2期113-120,共8页
The objective of this study is to assess commonly used formulae (Sheppard, Campbell, Hadlock I, II, III, and IV) for estimation of fetal weight in Sudanese population. A descriptive cross-sectional study was conducted... The objective of this study is to assess commonly used formulae (Sheppard, Campbell, Hadlock I, II, III, and IV) for estimation of fetal weight in Sudanese population. A descriptive cross-sectional study was conducted at Saudi Hospital-Khartoum-Sudan;from December 2015 to April 2016. The study included 225 singleton pregnancies. The fetal biometry—Biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), femur length (FL) and actual birth weights (ABW) were taken. Statistical analysis showed significant results at p ≤ 0.005. Results showed that the significant highest positive correlation between the ABW and the EFW/Kg was seen in the Hadlock I, III and IV equations having an equal values (0.951) followed by Hadlock II (0.946), Sheppard (0.872) and lastly Campbell (-0.925) with significant high degree of negative correlation. The new established equation EFW<sub>FLHCAC</sub> is the best formula identified in our study to predict Sudanese babies weight ranged between 1.86 Kg to 3.987 Kg. 展开更多
关键词 ULTRASONOGRAPHY fetal weight Gestational Age
下载PDF
Ultrasound estimation of fetal weight in twins by artificial neural network 被引量:2
3
作者 Hanieh Mohammadi Meshkat Nemati +3 位作者 Zohreh Allahmoradi Hoda Forghani Raissi Somayeh Saraf Esmaili Ali Sheikhani 《Journal of Biomedical Science and Engineering》 2011年第1期46-50,共5页
This study was undertaken to determine the accuracy of using Ultrasound (US) estimation of twin fetuses by use of Artificial Neural Network. At First, as the training group, we performed US examinations on 186 healthy... This study was undertaken to determine the accuracy of using Ultrasound (US) estimation of twin fetuses by use of Artificial Neural Network. At First, as the training group, we performed US examinations on 186 healthy singleton fetuses within 3 days of delivery. Three input variables were used to construct the ANN model: abdominal circumference (AC), ab-dominal diameter (AD), biparietal diameter (BPD). Then, a total of 121 twin fetuses were assessed sub-sequently as the validation group. In validation group, the mean absolute error and the mean absolute per-cent error between estimated fetal weight and actual fetal weight was 261.77 g and 7.81%, respectively. Results show that, twin estimation of birth weight by ultrasound correlates fairly well with the actual weights of twin fetuses. 展开更多
关键词 ULTRASOUND fetal weight ESTIMATION TWIN Artificial Neural Network
下载PDF
Factors Influencing the Accuracy of Sonographyestimated Fetal Weight:A Retrospective Cohort Study in the Chinese Population
4
作者 Fang-Can Sun Hai-Hong Wang +6 位作者 Jing-Jing Zhang Xin-Xian Gu Ting Hu Ming-Yue Wang Yin-Di Zhu You-Guo Cheni Bing Han 《Reproductive and Developmental Medicine》 CAS CSCD 2023年第4期203-209,共7页
Objective:To evaluate the accuracy of sonography-estimated fetal weight(EFW)and to determine the potential factors influencing EFW accuracy in the Chinese population.Methods:Eleven widely used formulae were chosen to ... Objective:To evaluate the accuracy of sonography-estimated fetal weight(EFW)and to determine the potential factors influencing EFW accuracy in the Chinese population.Methods:Eleven widely used formulae were chosen to evaluate the accuracy of EFW in 7016 cases in a retrospective cohort study.Nine potential factors(prenatal body mass index[BMI],gestational age[GA],birth weight[BW],fetal sex,fetal presentation,amniotic fluid volume[AFV],seniority of sonographers,the time interval between ultrasonic measurement and delivery,and diabetes mellitus)were analyzed by binary logistic regression to determine whether they influenced sonography-EFW.Results:All 11 models had high correlation coefficients between EFW and BW(r=0.819–0.843).Model 3 was the most accurate formula for the Chinese population.Compared to fetuses with EFW of 2500–3999g,the accuracy of EFW decreased by 69.10%(P<0.001)for fetuses less than 2500g,and decreased by 54.10%(P<0.001)for fetuses larger than 4000g.The accuracy of EFW in female fetuses decreased by 12.70%compared with male fetuses(P=0.021).Compared to the EFW calculated 1-3 days before delivery,the accuracy of the EFW performed 4–7 days before delivery showed a significant decrease(P=0.014).The accuracy of EFW was influenced by the individual measurement accuracy of the sonographers.Maternal BMI,DM,GA,fetal presentation,and AFV did not influence the accuracy of EFW after adjustment.Conclusion:Model 3 was the most accurate model for the Chinese population.The BW,fetal sex,time interval,and technique of the sonographers had different influences on the accuracy of EFW. 展开更多
关键词 ACCURACY Estimated fetal weight ULTRASONOGRAPHY fetal sex Birth weight
原文传递
Predicting fetal weight by three-dimensional limb volume ultrasound (AVol/TVol) and abdominal circumference 被引量:2
5
作者 Li Kang Qing-Qing Wu +2 位作者 Li-Juan Sun Feng-Yun Gao Jing-Jing Wang 《Chinese Medical Journal》 SCIE CAS CSCD 2021年第9期1070-1078,共9页
Background:Fetal weight is an important parameter to ensure maternal and child safety.The purpose of this study was to use three-dimensional(3D)limb volume ultrasound combined with fetal abdominal circumference(AC)mea... Background:Fetal weight is an important parameter to ensure maternal and child safety.The purpose of this study was to use three-dimensional(3D)limb volume ultrasound combined with fetal abdominal circumference(AC)measurement to establish a model to predict fetal weight and evaluate its efficiency.Methods:A total of 211 participants with single pregnancy(28-42 weeks)were selected between September 2017 and December 2018 in the Beijing Obstetrics and Gynecology Hospital of Capital Medical University.The upper arm(AVol)/thigh volume(TVol)of fetuses was measured by the 3D limb volume technique.Fetal AC was measured by two-dimensional ultrasound.Nine cases were excluded due to incomplete information or the interval between examination and delivery>7 days.The enrolled 202 participants were divided into a model group(134 cases,70%)and a verification group(68 cases,30%)by mechanical sampling method.The linear relationship between limb volume and fetal weight was evaluated using Pearson Chi-squared test.The prediction model formula was established by multivariate regression with data from the model group.Accuracy of the model formula was evaluated with verification group data and compared with traditional formulas(Hadlock,Lee2009,and INTERGROWTH-21st)by paired t-test and residual analysis.Receiver operating characteristic curves were generated to predict macrosomia.Results:AC,AVol,and TVol were linearly related to fetal weight.Pearson correlation coefficient was 0.866,0.862,and 0.910,respectively.The prediction model based on AVol/TVol and AC was established as follows:Y=-481.965+12.194TVol+15.358AVol+67.998AC,R2adj=0.868.The scatter plot showed that when birth weight fluctuated by 5%(i.e.,95%to 105%),the difference between the predicted fetal weight by the model and the actual weight was small.A paired t-test showed that there was no significant difference between the predicted fetal weight and the actual birth weight(t=-1.015,P=0.314).Moreover,the residual analysis showed that the model formula’s prediction efficiency was better than the traditional formulas with a mean residual of 35,360.170.The combined model of AVol/TVol and AC was superior to the Lee2009 and INTERGROWTH-21st formulas in the diagnosis of macrosomia.Its predictive sensitivity and specificity were 87.5%and 91.7%,respectively.Conclusion:Fetal weight prediction model established by semi-automatic 3D limb volume combined with AC is of high accuracy,sensitivity,and specificity.The prediction model formula shows higher predictive efficiency,especially for the diagnosis of macrosomia. 展开更多
关键词 fetal weight prediction Limb volume Three-dimensional ultrasound
原文传递
New Sudanese Reference Chart of Fetal Bi-ometry and Weight Using Ultrasonography
6
作者 Caroline Edward Ayad Ahmed Abdelrahim Mohammed Ibrahim +3 位作者 Mohammed Elfadil Mohammed GarElnabi Bushra Hussein Ahmed Elsafi Ahmed Abdalla Mohammed Ahmed Elshiekh Saleem 《Open Journal of Radiology》 2016年第2期131-139,共9页
Background: Many centers in Sudan use the reference data for fetal biometry. The recently published population-based reference either overestimated or underestimated the weight of the fetuses. Objective: To establish ... Background: Many centers in Sudan use the reference data for fetal biometry. The recently published population-based reference either overestimated or underestimated the weight of the fetuses. Objective: To establish a national reference for fetal biometry, and weight by gestational age for singleton fetuses in Sudan. Methods: Data were collected on all singleton live births documented in the data collection sheet done at Saudi Hospital from 2015 to 2016 (n = 225). Gestational age estimation was based on the last menstrual period and fetal ultrasound thereafter. Fetal biometry and weight and other 6 fetal weight formulae were assessed. Reference data for fetal growth by gestational age were created. Results: New charts and reference equations are reported in Sudanese population for fetal biparietal diameter, head circumference, abdominal circumference and femur length and fetal weight. Conclusion: We advocate that these reference charts and equations for fetal biometry and weight might be valuable in the clinical use for appropriate ethnic Sudanese. 展开更多
关键词 fetal Biometry fetal weight Gestational Age ULTRASONOGRAPHY
下载PDF
Outcomes of Fetal Macrosomia and Associated Factors: A Case-Control Facility Based Study
7
作者 Anne Esther Njom Nlend Josepha Gwodog Arsene Brunelle Sandie 《Open Journal of Pediatrics》 CAS 2023年第2期196-206,共11页
Objective: To identify risk factors of perinatal complications among macrosomic babies in a third level health care facility. Method: We conducted a case-control institutional based study. Cases (macrosomic babies and... Objective: To identify risk factors of perinatal complications among macrosomic babies in a third level health care facility. Method: We conducted a case-control institutional based study. Cases (macrosomic babies and mothers with perinatal complications) and controls (pairs free of perinatal complication) of singleton live births were extracted from the maternity registry from January 2017 to December 2019. Matching was done for sex and gestational age after exclusion of genetic cause of macrosomia. The main primary outcome was the risk factors for complications. Logistic regression was used to estimate the odds ratio and the magnitude of association between the primary endpoint and the different covariates of the study. Results: Out of 362 couples included, we had 186 cases and 176 controls. The main perinatal complications were the delivery by caesarean section (26.5%) and lesions of the genital canal, 20.2%. There were no maternal deaths. Among newborns, metabolic complications (19.6%) were a leading cause of harmful outcomes before respiratory complications (12.4%), dystocic presentations (6.3%) or traumatic injuries (1.7%). The neonatal case fatality rate was 2.8%. Maternal age ≥30 years (p = 0.024);non-screening for gestational diabetes (p = 0.027);history of caesarean section (p = 0.041);weight gain ≥16 kg (p 0.001);maternal HIV (p = 0.047);birth weight ≥4500 g (p = 0.015) and birth height ≥52.7 ± 1.7 cm (p = 0.026) were risk factors for perinatal adverse outcomes. Conclusion: The delivery of a macrosomic baby remains problematic in this setting, and emphasizes the need to improve routine screening of gestational diabetes within a quality of prenatal follow-up through a multidisciplinary perinatal team involving obstetricians, endocrinologists and neonatal pediatricians. 展开更多
关键词 fetal Macrosomia Gestational Diabetes Maternal Obesity Birth weight fetal Growth
下载PDF
胎儿体质量估计对初产妇巨大儿分娩方式及围产结局的临床观察
8
作者 陈磊 杨明芳 《北京医学》 CAS 2024年第3期222-225,共4页
目的观察胎儿体质量估计对初产妇巨大儿的分娩方式和围产结局的影响。方法选取2022年1月至2023年12月北京市海淀区妇幼保健院分娩的足月单胎初产妇206例,根据估计体质量分为甲组(估计胎儿体质量<4000 g,118例)和乙组(估计胎儿体质量... 目的观察胎儿体质量估计对初产妇巨大儿的分娩方式和围产结局的影响。方法选取2022年1月至2023年12月北京市海淀区妇幼保健院分娩的足月单胎初产妇206例,根据估计体质量分为甲组(估计胎儿体质量<4000 g,118例)和乙组(估计胎儿体质量≥4000 g,88例)。比较两组产妇及新生儿的分娩方式和分娩结局等。结果206例初产妇年龄21~39岁,平均(30.6±3.4)岁。与乙组相比,甲组阴道分娩比例较高(61.9%比40.9%)、剖宫产比例较低(32.2%比56.8%),两组分娩方式的差异有统计学意义(P<0.05)。甲组试产率明显高于乙组(90.7%比59.1%),差异有统计学意义(P<0.05)。甲组产后出血量(容积法)和校正产后出血量均高于乙组[350(300,500)ml比300(300,380)ml,440(230,720)ml比360(160,560)ml],差异有统计学意义(P<0.05)。两组胎儿窘迫、肩难产、新生儿窒息比例的差异无统计学意义(P>0.05)。结论低估胎儿体质量可增加初产妇巨大儿试产率及阴道分娩率,也增加了产后出血量,但并未增加胎儿窘迫、肩难产、新生儿窒息等分娩并发症。建议胎儿估计体质量<4500 g且有阴道分娩意愿的产妇,应该在充分告知的情况下,增加试产机会。 展开更多
关键词 巨大儿 胎儿体质量估计 阴道分娩 剖宫产 母婴结局 围产期
下载PDF
产时Ⅱ度及以上会阴裂伤风险预测模型的构建和验证
9
作者 胡寅初 杨明晖 +2 位作者 李燕 付立 陆虹 《护理学杂志》 CSCD 北大核心 2024年第6期32-36,62,共6页
目的 构建产时Ⅱ度及以上会阴裂伤风险预测随机森林算法模型,并初步评价模型的预测性能。方法 采用方便抽样法,选取经阴道分娩的1 366例产妇为研究对象,将其按照7∶3的比例随机分为训练集和验证集。采用LASSO回归分析筛选产时Ⅱ度及以... 目的 构建产时Ⅱ度及以上会阴裂伤风险预测随机森林算法模型,并初步评价模型的预测性能。方法 采用方便抽样法,选取经阴道分娩的1 366例产妇为研究对象,将其按照7∶3的比例随机分为训练集和验证集。采用LASSO回归分析筛选产时Ⅱ度及以上会阴裂伤的风险因素,采用随机森林算法构建预测模型,计算ROC曲线下面积、预测准确率、灵敏度和特异度等评价模型的性能。结果 共计8个预测因子被纳入随机森林模型中,分别为孕前BMI、孕期体质量增加、初产妇、剖宫产史、硬膜外麻醉、催产、引产和胎儿估计体质量,其中胎儿估计体质量对产时Ⅱ度及以上会阴裂伤的影响最大,其次是初产妇和催产。随机森林模型在验证集中的ROC曲线下面积为0.698(95%CI:0.645~0.751),预测准确率为80.0%(95%CI:75.8%~83.8%),灵敏度和特异度分别为50.5%和89.1%。结论 基于随机森林算法构建的产时Ⅱ度及以上会阴裂伤风险预测模型具有一定的预测价值,但预测性能仍有待提高。 展开更多
关键词 阴道分娩 会阴裂伤 初产妇 剖宫产史 催产 胎儿估计体质量 预测模型 随机森林算法
下载PDF
基于超声血流参数评估晚发型胎儿宫内生长受限的研究
10
作者 甘国财 赵永峰 +3 位作者 巨芙蓉 马淑梅 才让卓玛 杜会英 《检验医学与临床》 CAS 2024年第11期1505-1509,共5页
目的分析超声血流参数对晚发型胎儿宫内生长受限(FGR)的预测价值。方法选取2020年6月至2022年6月青海大学附属医院收治的82例晚发型FGR孕产妇作为研究对象。根据新生儿妊娠结局分为结局良好组(51例)与结局不良组(31例)。另选取同期在青... 目的分析超声血流参数对晚发型胎儿宫内生长受限(FGR)的预测价值。方法选取2020年6月至2022年6月青海大学附属医院收治的82例晚发型FGR孕产妇作为研究对象。根据新生儿妊娠结局分为结局良好组(51例)与结局不良组(31例)。另选取同期在青海大学附属医院产检且胎儿生长正常的32例孕产妇作为对照组。比较3组基线资料及分娩前最后1次超声的大脑中动脉搏动指数(MCA-PI)、脐动脉搏动指数(UA-PI)、脑-胎盘血流比(CPR)、心血管整体评分(CVPS)、Hadlock胎儿体质量估测(EFW),绘制受试者工作特征(ROC)曲线评估上述超声血流参数对晚发型FGR孕产妇不良妊娠结局的预测价值。结果结局不良组新生儿出生体质量均低于结局良好组及对照组,且结局良好组低于对照组,差异均有统计学意义(P<0.05)。结局不良组分娩孕周短于对照组和结局良好组,差异均有统计学意义(P<0.05)。结局不良组MCA-PI、CPR、CVPS、EFW均低于结局良好组及对照组,且结局良好组低于对照组,差异均有统计学意义(P<0.05)。结局不良组UA-PI高于结局良好组及对照组,且结局良好组高于对照组,差异均有统计学意义(P<0.05)。ROC曲线分析结果显示,MCA-PI、UA-PI、CPR、CVPS、EFW单独预测晚发型FGR孕产妇不良妊娠结局的曲线下面积分别为0.667、0.792、0.762、0.820、0.917。结论超声血流参数MCA-PI、UA-PI、CPR、CVPS、EFW均对晚发型FGR孕产妇不良妊娠结局有一定预测价值,其中CVPS及EFW预测价值较高,可为临床治疗及判断分娩时机提供重要依据。 展开更多
关键词 胎儿宫内生长受限 晚发型 妊娠结局 超声 血流参数 心血管整体评分 胎儿体质量估测
下载PDF
早产儿桡动脉有创血压与无创血压测量结果比较
11
作者 李容丹 谢巧庆 +2 位作者 司徒妙琼 黄科志 李智英 《护理研究》 北大核心 2024年第2期339-343,共5页
目的:探讨早产儿桡动脉有创动脉血压(IBP)和无创血压(NIBP)测量结果的一致性和差异性。方法:采用回顾性研究方法,选取2020年12月—2021年12月中山大学附属第一医院新生儿科行IBP测量的93例危重早产儿为研究对象,记录患儿的IBP和NIBP收... 目的:探讨早产儿桡动脉有创动脉血压(IBP)和无创血压(NIBP)测量结果的一致性和差异性。方法:采用回顾性研究方法,选取2020年12月—2021年12月中山大学附属第一医院新生儿科行IBP测量的93例危重早产儿为研究对象,记录患儿的IBP和NIBP收缩压、舒张压和平均动脉压,分析IBP和NIBP相关性、一致性,并根据体重和胎龄进行亚组分析。结果:收集93例患儿的IBP和NIBP共1771对,排除无效血压,最终纳入IBP和NIBP为1455对。Pearson相关性分析结果显示,IBP收缩压和NIBP收缩压(r=0.754,P<0.001)、IBP舒张压和NIBP舒张压(r=0.747,P<0.001)、IBP平均动脉压和NIBP平均动脉压(r=0.791,P<0.001)均呈正相关。IBP收缩压和NIBP收缩压差值为(7.20±5.59)mmHg,95%一致性界限为-3.75~18.16 mmHg;IBP舒张压和NIBP舒张压差值为(0.09±4.34)mmHg,95%一致性界限为-8.41~8.60 mmHg;IBP平均动脉压和NIBP平均动脉压差值为(1.03±4.27)mmHg,95%一致性界限为-7.34~9.39 mmHg。体重>2.0 kg的患儿IBP收缩压和NIBP收缩压偏倚均值、IBP舒张压和NIBP舒张压偏倚均值、IBP平均动脉压和NIBP平均动脉压偏倚均值均小于体重≤1.0 kg的患儿和体重>1.0~2.0 kg的患儿。胎龄>32~<37周的患儿IBP收缩压和NIBP收缩压偏倚均值、IBP舒张压和NIBP舒张压偏倚均值、IBP平均动脉压和NIBP平均动脉压偏倚均值小于胎龄≤28周的患儿和胎龄>28~32周的患儿。结论:早产儿桡动脉IBP和NIBP呈正相关,且IBP和NIBP间具有良好的一致性。NIBP可用于血流动力学稳定的早产儿,血流动力学不稳定且需要使用血管活性药物的婴儿建议进行IBP测量。 展开更多
关键词 早产儿 有创动脉血压 无创血压 相关性 一致性 体重 胎龄 护理
下载PDF
分娩前超声检查对不同营养状况孕妇胎儿体质量估计效果
12
作者 张蔼 王田华 +3 位作者 于学娟 王玉婷 姜洁璇 范冬梅 《青岛大学学报(医学版)》 CAS 2024年第1期81-84,共4页
目的比较超声Hadlock法与临床公式法(袁东法)评估胎儿体质量的符合率。方法回顾分析2020年1—4月在青岛市妇女儿童医院产科住院分娩的1715例孕妇的临床资料,按孕前体质量指数(BMI)分为体质量过低(<18.5 kg/m 2)组177例、体质量正常(1... 目的比较超声Hadlock法与临床公式法(袁东法)评估胎儿体质量的符合率。方法回顾分析2020年1—4月在青岛市妇女儿童医院产科住院分娩的1715例孕妇的临床资料,按孕前体质量指数(BMI)分为体质量过低(<18.5 kg/m 2)组177例、体质量正常(18.5~23.9 kg/m 2)组1118例、体质量超标(24.0~27.9 kg/m 2)组317例、肥胖(≥28.0 kg/m 2)组103例。分别应用超声Hadlock法与袁东法估测胎儿体质量,比较两种方法计算的估计胎儿体质量与实际出生体质量的差异。结果4组超声Hadlock法评估胎儿体质量的准确率均明显高于袁东法(χ2=25.212~435.840,P<0.01);Hadlock法评估胎儿体质量的准确率4组差异无统计学意义(χ2=1.392,P>0.05),袁东法评估胎儿体质量的准确率随BMI升高而降低,差异有统计学意义(χ2=59.34,P<0.01)。结论Hadlock法评估胎儿体质量的准确率明显高于袁东法,且不受孕妇孕前BMI影响。 展开更多
关键词 孕妇 人体质量指数 超声检查 产前 估测 胎儿体重
下载PDF
正常孕妇妊娠期增重和糖脂代谢与巨大儿发生风险的关系
13
作者 高婧 秦飞 +2 位作者 陈超 熊姚西 程蔚蔚 《国际妇产科学杂志》 CAS 2024年第2期176-180,共5页
目的:分析妊娠期体质量和糖脂水平在分娩巨大儿的无妊娠合并症/并发症、非肥胖、非高龄的正常孕妇中的变化特点,探讨其对巨大儿发生风险的影响。方法:选取2020年9—12月在上海交通大学医学院附属国际和平妇幼保健院定期产检的正常孕妇,... 目的:分析妊娠期体质量和糖脂水平在分娩巨大儿的无妊娠合并症/并发症、非肥胖、非高龄的正常孕妇中的变化特点,探讨其对巨大儿发生风险的影响。方法:选取2020年9—12月在上海交通大学医学院附属国际和平妇幼保健院定期产检的正常孕妇,根据是否分娩巨大儿分为巨大儿组(104例)和对照组(258例),比较2组基本情况和妊娠期糖脂水平,并采用Logistic回归分析正常孕妇分娩巨大儿的影响因素。结果:相较于正常对照组,巨大儿组妊娠期空腹血糖、妊娠早晚期三酰甘油(triglyceride,TG)水平更高,妊娠早晚期高密度脂蛋白(high density lipoprotein,HDL)水平更低,且巨大儿组妊娠期TG变化差值更大、HDL变化差值更小(均P<0.05)。与妊娠期增重适宜的正常孕妇相比,增重过多的正常孕妇分娩巨大儿的风险升高142%(OR=2.42,95%CI:1.34~4.39),增重不足的正常孕妇分娩巨大儿的风险降低73%(OR=0.27,95%CI:0.10~0.77);妊娠晚期HDL每升高1 mmol/L,分娩巨大儿风险下降79%(OR=0.21,95%CI:0.08~0.57)。结论:正常孕妇群体仍需严格控制妊娠期体质量以降低巨大儿的发生风险,并且仍需关注血脂代谢,其中妊娠晚期HDL的水平及变化情况或可辅助筛查隐匿性巨大儿。 展开更多
关键词 巨大胎儿 妊娠 血糖 脂类 孕期体重增长
下载PDF
超声预测胎儿体质量方法比较及孕期增重对其准确性的影响研究
14
作者 谢朝玲 秦川 刘颂平 《实用妇产科杂志》 CAS CSCD 北大核心 2024年第3期208-212,共5页
目的:比较分析11种超声参数预测胎儿体质量公式的准确性,探讨孕期体质量增加(GWG)对超声估测胎儿体质量准确性的影响。方法:收集2020年8月至2020年12月于复旦大学附属金山医院分娩的502例单胎,足月分娩产妇孕期增重、分娩前7天内胎儿超... 目的:比较分析11种超声参数预测胎儿体质量公式的准确性,探讨孕期体质量增加(GWG)对超声估测胎儿体质量准确性的影响。方法:收集2020年8月至2020年12月于复旦大学附属金山医院分娩的502例单胎,足月分娩产妇孕期增重、分娩前7天内胎儿超声测量指标及新生儿出生体质量,计算并分析多种超声预测公式的准确性。根据孕期体质量增长标准,即单胎妊娠孕前体质量指数(BMI)<18.5 kg/m^(2)者孕期合理增重为12.5~18.0 kg,BMI 18.5~24.9 kg/m^(2)者增重11.5~16.0 kg,BMI 25.0~29.9 kg/m^(2)者增重7.0~11.5 kg,BMI≥30.0 kg/m^(2)者增重5.0~9.0 kg,将病例分为GWG过少组(125例)、正常组(202例)和过多组(175例),分析不同GWG对于超声预测胎儿体质量准确性的影响。结果:11种超声参数预测胎儿体质量公式中,HadlockⅢ公式预测胎儿体质量的绝对误差为186.64±149.28 g,相对误差为(5.52±4.18)%,在11种预测公式中误差最小,差异有统计学意义(P<0.05),绝对误差和相对误差符合率分别为72.31%、86.25%,均为最高,差异有统计学意义(P<0.05)。GWG过少组、正常组和过多组利用HadlockⅢ公式预测胎儿体质量时,绝对误差分别为190.23±136.69 g、148.12±99.39 g、228.54±189.57 g,相对误差分别为(5.95±4.25)%、(4.40±2.78)%、(6.49±5.09)%,差异均具有统计学意义(P<0.05)。结论:HadlockⅢ公式预测胎儿体质量的准确性优于其他公式,但其准确性可受GWG的影响,临床中预测胎儿体质量时需多方面综合考量。 展开更多
关键词 超声预测 胎儿体质量 体质量增长 准确性
下载PDF
超声多参数Z-评分联合模型评估胎儿生长受限的价值研究
15
作者 王超 王启荣 +3 位作者 安立强 贾建军 杨艳艳 王璇 《华北理工大学学报(医学版)》 2024年第1期11-16,共6页
目的探讨超声多参数Z-评分联合预测模型评估胎儿生长受限(FGR)的价值。方法回顾性分析2017年1月~2020年12月我院收治的88例单胎、孕22~29周且婴儿出生后确诊为FGR的孕妇临床资料,并以同期年龄、产次、妊娠期合并症等一般资料基本匹配的... 目的探讨超声多参数Z-评分联合预测模型评估胎儿生长受限(FGR)的价值。方法回顾性分析2017年1月~2020年12月我院收治的88例单胎、孕22~29周且婴儿出生后确诊为FGR的孕妇临床资料,并以同期年龄、产次、妊娠期合并症等一般资料基本匹配的108例非FGR孕妇资料作为对照。采用Logistic回归方程建立胎儿体质量测定(EFW)、脐动脉(UA)、大脑中动脉(MCA)、脑-胎盘比(CPR)、腹围(AC)和头-腹围比值(HC/AC)等参数的单参数模型和多参数联合模型,并绘制受试者工作特征曲线(ROC),通过与Hadlock-EFW百分位数(Hadlock-EFWc)比较,以评估不同模型预测FGR的价值。结果FGR组EFW、EFWc及CPR、AC、HC/AC的Z-评分均明显低于非FGR组,UA-PI、MCA-PI的Z-评分高于非FGR组(P<0.001)。联合模型预测FGR的灵敏度为82.95%、特异度为70.37%、约登指数为0.533、ROC曲线下面积(AUC)为0.897,95%CI为(0.795,0.956),其预测效能优于Hadlock-EFWc及各超声单参数(P<0.05)。结论超声多参数Z-评分联合模型预测FGR相较Hadlock-EFWc和超声单参数更为准确且诊断价值更高。 展开更多
关键词 超声参数 胎儿生长受限 Z-评分 胎儿体重测定
下载PDF
超声评估妊娠期糖尿病产妇胎儿体重的应用价值
16
作者 张云鹤 马蕊 李威 《四川解剖学杂志》 2024年第1期22-24,共3页
目的:探讨超声评估妊娠期糖尿病(GDM)产妇胎儿体重中的应用价值.方法:选取2022年1月至2022年12月本院收治的108例GDM产妇作为研究对象,设为观察组,选取同期108例健康孕妇作为对照组.对两组产妇均给予超声检查,对比两组胎儿的生长情况,... 目的:探讨超声评估妊娠期糖尿病(GDM)产妇胎儿体重中的应用价值.方法:选取2022年1月至2022年12月本院收治的108例GDM产妇作为研究对象,设为观察组,选取同期108例健康孕妇作为对照组.对两组产妇均给予超声检查,对比两组胎儿的生长情况,胎儿发育情况,新生儿中巨大儿出生率.结果:观察组胎儿肝脏长度和头围大于对照组,脐动脉搏动指数、阻力指数均高于对照组,新生儿中巨大儿出生率高于对照组,差异均有统计学意义(P<0.05).结论:对GDM产妇产前实施超声检查,可明显判断胎儿生长发育情况,以便临床采取相应的预防和治疗措施. 展开更多
关键词 超声 妊娠期糖尿病 胎儿体重 临床价值 产妇
下载PDF
Effect of Antenatal Depression on Fetal Growth Outcomes at the Jos University Teaching Hospital Jos, Plateau State, Nigeria
17
作者 Bwatyum Annah Gyang Umar Musa +2 位作者 Agbir Terkura Michael Gyang Mark Davou Obindo James Taiwo 《Open Journal of Psychiatry》 2022年第4期336-344,共9页
Background: Depression is the most prevalent psychiatric disorder in pregnancy and it is associated with psychosocial and obstetric factors. Studies have shown that pregnancy does not prevent women from becoming depre... Background: Depression is the most prevalent psychiatric disorder in pregnancy and it is associated with psychosocial and obstetric factors. Studies have shown that pregnancy does not prevent women from becoming depressed;rather, it may be a time when depression occurs for the first time in some women. Antenatal depression has been identified as a risk factor for post natal depression, adverse obstetric outcomes, poorer neonatal outcomes and higher growth retardation in infants. Purpose: This study aimed to determine the fetal growth outcomes among depressed pregnant women in their third trimester attending antenatal clinic at the Jos University Teaching Hospital (JUTH), Jos, Plateau State, Nigeria. Method: A prospective cohort study design was used to assess 514 women who consented to the study (256 cases and 258 controls). A socio-demographic questionnaire was given to the women to fill out the study entry. Edinburgh Post Natal Depression Scale (EPDS) was used to screen for depression and MINI neuropsychiatric interviews were used to diagnose depression in those women found to be at risk of depression using the EPDS. Ultrasonography was used to determine the fetal weight in the third trimester of pregnancy. The birth weight of the babies born to the women was obtained from the birth register in the labor ward and the fetal growth rate was calculated from the estimated fetal weight on ultrasound scan in late pregnancy and the birth weight of babies. Result: The mean fetal weight in the third trimester for non-depressed women was slightly higher than in depressed women though the difference was not statistically significant (P = 0.431). The difference in the mean calculated fetal growth rate for fetuses of non-depressed women in the third trimester was statistically significantly higher than in depressed women (p = 0.000). Depressed women also had babies with lower birth weight than non-depressed women and the difference was statistically significant (p = 0.00). 展开更多
关键词 DEPRESSION Antenatal Depression fetal weight fetal Growth Rate Birth weight
下载PDF
低分子肝素治疗胎儿生长受限的效果
18
作者 黄宁梓 黄修治 《中外医药研究》 2024年第5期24-26,共3页
目的:分析低分子肝素治疗胎儿生长受限的效果。方法:选取2021年4月—2022年4月惠州市中心人民医院及惠州市第一人民医院收治的胎儿生长受限孕妇70例为研究对象。依据随机数字表法分为对照组和观察组,各35例。对照组行传统治疗,观察组在... 目的:分析低分子肝素治疗胎儿生长受限的效果。方法:选取2021年4月—2022年4月惠州市中心人民医院及惠州市第一人民医院收治的胎儿生长受限孕妇70例为研究对象。依据随机数字表法分为对照组和观察组,各35例。对照组行传统治疗,观察组在对照组基础上应用低分子肝素治疗。比较两组胎儿生长发育指标、孕妇宫高、凝血功能、胎盘血流动力学指标、妊娠不良结局及不良反应发生情况。结果:治疗2周后,两组胎儿腹围、头围、股骨长及孕妇宫高增大,观察组大于对照组,差异有统计学意义(P<0.05)。治疗2周后,两组孕妇活化部分凝血活酶时间(APTT)、凝血酶原时间(PT)水平升高,D-二聚体(D-D)及纤维蛋白原(FIB)水平降低,观察组APTT、PT水平高于对照组,D-D、Fib水平低于对照组,差异有统计学意义(P<0.05)。治疗2周后,两组胎儿脐动脉搏动指数、阻力指数、收缩末期最大血流速度/舒张末期最大血流速度水平降低,观察组低于对照组,差异有统计学意义(P<0.05)。观察组孕妇妊娠不良结局、不良反应发生率低于对照组,差异有统计学意义(P<0.05)。结论:低分子肝素治疗胎儿生长受限效果较好,可改善胎儿生长发育指标及血流动力学指标,降低妊娠不良结局发生率,改善母体凝血功能。 展开更多
关键词 低分子肝素 胎儿生长受限 凝血功能
下载PDF
阿司匹林联合低分子肝素钙对生长受限胎儿的应用效果及对孕妇分娩结局的影响
19
作者 石方方 潘蕾蕾 《中华养生保健》 2024年第10期43-46,共4页
目的分析阿司匹林联合低分子肝素钙治疗胎儿生长受限的效果及对脐动脉血流参数及分娩结局的影响,以改善胎儿宫内受限情况和母婴分娩结局。方法选择2020年5月—2021年5月重庆市酉阳县人民医院收治的70例发生胎儿生长受限的孕妇患者作为... 目的分析阿司匹林联合低分子肝素钙治疗胎儿生长受限的效果及对脐动脉血流参数及分娩结局的影响,以改善胎儿宫内受限情况和母婴分娩结局。方法选择2020年5月—2021年5月重庆市酉阳县人民医院收治的70例发生胎儿生长受限的孕妇患者作为研究对象,采用单双号法将所有患者分为研究组和对照组,每组35例,研究组治疗药物为阿司匹林联合低分子肝素钙,对照组治疗药物为低分子肝素钙,比较治疗前、后两组胎儿脐动脉血流参数水平,包含脐血流搏动指数(PI)、脐动脉血流阻力指数(RI)、收缩末期峰值/舒张末期峰值(S/D)、头围、股骨长、体质量、双顶径等发育指标水平、治疗总有效率及母婴不良分娩结局发生率。结果治疗后,研究组胎儿脐动脉血流参数水平均显著低于对照组,研究组胎儿头围、腹围、股骨长、股骨长等发育指标水平显著高于对照组,研究组治疗总有效率显著高于对照组,研究组母婴不良分娩结局发生率显著低于对照组,差异有统计学意义(P<0.05)。结论胎儿生长受限应用阿司匹林联合低分子肝素钙治疗可取得良好的治疗效果,不仅能有效改善胎儿脐动脉血流参数和促进胎儿良好生长发育,还能降低母婴不良分娩结局发生率,从而改善母婴预后,值得临床应用。 展开更多
关键词 阿司匹林 低分子肝素钙 胎儿生长受限 脐动脉血流参数 分娩结局
下载PDF
Prenatal Exposure to Polycyclic Aromatic Hydrocarbons and Birth Weight in China 被引量:2
20
作者 Qiong Chen Tongzhang Zheng +13 位作者 Bryan A. Bassig Yibin Cheng Brian Leaderer Shaobin Lin Theodore Holford Jie Qiu Yawei Zhang Kunchong Shi Yong Zhu Jianjun Niu Yonghong Li Huan Guo Xiaobin Hu Yinlong Jin 《Open Journal of Air Pollution》 2014年第4期100-110,共11页
Adverse birth outcomes are a leading cause of mortality in children in China, but the environmental influences of these conditions remain largely unexplained in this population. We aimed to evaluate the levels of poly... Adverse birth outcomes are a leading cause of mortality in children in China, but the environmental influences of these conditions remain largely unexplained in this population. We aimed to evaluate the levels of polycyclic aromatic hydrocarbons (PAHs) in Chinese pregnant women and their newborns, and to examine the association between levels of PAHs and infant birth weight. We conducted a cross-sectional study including 81 pairs of mothers and newborns from four hospitals in four different cities in China. High Performance Liquid Chromatography was used to measure the concentration of nine PAHs in maternal and cord blood and multiple linear regression analyses were used to evaluate the associations of these PAHs with infant birth weight. Anthracene (ANT) had the highest average concentration and detection rate (geometric mean = 69.54 ng/g and 76.5%, respectively) in maternal serum samples, while fluoranthene (FLT) had the highest concentration and detection rate (geometric mean = 68.4 ng/g and 50.6%, respectively) in the cord blood. Most of the measured PAHs in maternal serum and three PAHs in cord blood were inversely but non-significantly associated with birth weight. The strongest associations were observed for higher concentrations of benzo (a) pyrene (BaP) in maternal serum (230.7 g decrease for levels > median vs. < LOD;p = 0.151) and for ANT in cord blood (153.1 g decrease for levels < median vs. < LOD;p = 0.208). Ant and FLT were the predominant PAHs in the maternal and cord blood serum. Serum concentrations of several measured PAHs were associated with a decreased birth weight, although not significantly, suggesting that further studies with larger sample sizes are needed to validate our findings. 展开更多
关键词 MATERNAL Exposure POLYCYCLIC Aromatic Hydrocarbon BIRTH weight fetal Development MATERNAL Serum
下载PDF
上一页 1 2 20 下一页 到第
使用帮助 返回顶部