期刊文献+
共找到5,892篇文章
< 1 2 250 >
每页显示 20 50 100
High-order Bragg forward scattering and frequency shift of low-frequency underwater acoustic field by moving rough sea surface
1
作者 莫亚枭 张朝金 +2 位作者 鹿力成 孙启航 马力 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期459-470,共12页
Acoustic scattering modulation caused by an undulating sea surface on the space-time dimension seriously affects underwater detection and target recognition.Herein,underwater acoustic scattering modulation from a movi... Acoustic scattering modulation caused by an undulating sea surface on the space-time dimension seriously affects underwater detection and target recognition.Herein,underwater acoustic scattering modulation from a moving rough sea surface is studied based on integral equation and parabolic equation.And with the principles of grating and constructive interference,the mechanism of this acoustic scattering modulation is explained.The periodicity of the interference of moving rough sea surface will lead to the interference of the scattering field at a series of discrete angles,which will form comb-like and frequency-shift characteristics on the intensity and the frequency spectrum of the acoustic scattering field,respectively,which is a high-order Bragg scattering phenomenon.Unlike the conventional Doppler effect,the frequency shifts of the Bragg scattering phenomenon are multiples of the undulating sea surface frequency and are independent of the incident sound wave frequency.Therefore,even if a low-frequency underwater acoustic field is incident,it will produce obvious frequency shifts.Moreover,under the action of ideal sinusoidal waves,swells,fully grown wind waves,unsteady wind waves,or mixed waves,different moving rough sea surfaces create different acoustic scattering processes and possess different frequency shift characteristics.For the swell wave,which tends to be a single harmonic wave,the moving rough sea surface produces more obvious high-order scattering and frequency shifts.The same phenomena are observed on the sea surface under fully grown wind waves,however,the frequency shift slightly offsets the multiple peak frequencies of the wind wave spectrum.Comparing with the swell and fully-grown wind waves,the acoustic scattering and frequency shift are not obvious for the sea surface under unsteady wind waves. 展开更多
关键词 high-order Bragg scattering frequency shift low-frequency acoustic field moving rough sea surface
下载PDF
Suppression of stimulated Brillouin and Raman scatterings using an alternating frequency laser and transverse magnetic fields
2
作者 程瑞锦 李晓旬 +11 位作者 王清 刘德基 黄卓明 吕帅宇 周远志 张舒童 李雪铭 陈祖杰 王强 刘占军 曹莉华 郑春阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期545-553,共9页
A novel scheme to suppress both stimulated Brillouin scattering(SBS) and stimulated Raman scattering(SRS) by combining an alternating frequency(AF) laser and a transverse magnetic field is proposed. The AF laser allow... A novel scheme to suppress both stimulated Brillouin scattering(SBS) and stimulated Raman scattering(SRS) by combining an alternating frequency(AF) laser and a transverse magnetic field is proposed. The AF laser allows the laser frequency to change discretely and alternately over time. The suppression of SBS is significant as long as the AF difference is greater than the linear growth rate of SBS or the alternating time of the laser frequency is shorter than the linear growth time of SBS. However, the AF laser proves ineffective in suppressing SRS, which usually has a much higher linear growth rate than SBS. To remedy that, a transverse magnetic field is included to suppress the SRS instability. The electrons trapped in the electron plasma waves(EPWs) of SRS can be accelerated by the surfatron mechanism in a transverse magnetic field and eventually detrapped. While continuously extracting energy from EPWs, the EPWs are dissipated and the kinetic inflation of SRS is suppressed. The one-dimensional particle-in-cell simulation results show that both SBS and SRS can be effectively suppressed by combining the AF laser with a transverse magnetic field with tens of Tesla. The total reflectivity can be dramatically reduced by more than one order of magnitude. These results provide a potential reference for controlling SBS and SRS under the related parameters of inertial confinement fusion. 展开更多
关键词 stimulated Brillouin scattering stimulated Raman scattering alternating frequency laser transverse magnetic field
下载PDF
Diagnosing ratio of electron density to collision frequency of plasma surrounding scaled model in a shock tube using low-frequency alternating magnetic field phase shift
3
作者 吴明兴 谢楷 +3 位作者 刘艳 徐晗 张宝 田得阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期519-530,共12页
A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic... A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma. 展开更多
关键词 low-frequency alternating magnetic field phase shift shock-tube plasma diagnosis electron density collision frequency
下载PDF
Phase field model for electric-thermal coupled discharge breakdown of polyimide nanocomposites under high frequency electrical stress
4
作者 韩智云 李庆民 +3 位作者 李俊科 王梦溪 任瀚文 邹亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期114-124,共11页
In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heighte... In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heightened concerns regarding insulation failures. Meanwhile, the underlying mechanism behind discharge breakdown failure and nanofiller enhancement under high-frequency electrical stress remains unclear. An electric-thermal coupled discharge breakdown phase field model was constructed to study the evolution of the breakdown path in polyimide nanocomposite insulation subjected to high-frequency stress. The investigation focused on analyzing the effect of various factors, including frequency, temperature, and nanofiller shape, on the breakdown path of Polyimide(PI) composites. Additionally, it elucidated the enhancement mechanism of nano-modified composite insulation at the mesoscopic scale. The results indicated that with increasing frequency and temperature, the discharge breakdown path demonstrates accelerated development, accompanied by a gradual dominance of Joule heat energy. This enhancement is attributed to the dispersed electric field distribution and the hindering effect of the nanosheets. The research findings offer a theoretical foundation and methodological framework to inform the optimal design and performance management of new insulating materials utilized in high-frequency power equipment. 展开更多
关键词 dielectric discharge breakdown high frequency power electronic transformer polyimide nanocomposites phase field model
下载PDF
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
5
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
下载PDF
Ultrafast dynamics of femtosecond laser-induced high spatial frequency periodic structures on silicon surfaces
6
作者 Ruozhong Han Yuchan Zhang +6 位作者 Qilin Jiang Long Chen Kaiqiang Cao Shian Zhang Donghai Feng Zhenrong Sun Tianqing Jia 《Opto-Electronic Science》 2024年第3期33-46,共14页
Femtosecond laser-induced periodic surface structures(LIPSS)have been extensively studied over the past few decades.In particular,the period and groove width of high-spatial-frequency LIPSS(HSFL)is much smaller than t... Femtosecond laser-induced periodic surface structures(LIPSS)have been extensively studied over the past few decades.In particular,the period and groove width of high-spatial-frequency LIPSS(HSFL)is much smaller than the diffraction limit,making it a useful method for efficient nanomanufacturing.However,compared with the low-spatial-frequency LIPSS(LSFL),the structure size of the HSFL is smaller,and it is more easily submerged.Therefore,the formation mechanism of HSFL is complex and has always been a research hotspot in this field.In this study,regular LSFL with a period of 760 nm was fabricated in advance on a silicon surface with two-beam interference using an 800 nm,50 fs femtosecond laser.The ultrafast dynamics of HSFL formation on the silicon surface of prefabricated LSFL under single femtosecond laser pulse irradiation were observed and analyzed for the first time using collinear pump-probe imaging method.In general,the evolution of the surface structure undergoes five sequential stages:the LSFL begins to split,becomes uniform HSFL,degenerates into an irregular LSFL,undergoes secondary splitting into a weakly uniform HSFL,and evolves into an irregular LSFL or is submerged.The results indicate that the local enhancement of the submerged nanocavity,or the nanoplasma,in the prefabricated LSFL ridge led to the splitting of the LSFL,and the thermodynamic effect drove the homogenization of the splitting LSFL,which evolved into HSFL. 展开更多
关键词 laser-induced periodic surface structures(LIPSS) local field enhancement collinear pump-probe imaging silicon high spatial frequency periodic structures
下载PDF
Measurements of Majorana transition frequency shift in caesium atomic fountain clocks
7
作者 施俊如 王心亮 +6 位作者 杨帆 白杨 管勇 范思晨 刘丹丹 阮军 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期42-49,共8页
The caesium atomic fountain clock is a primary frequency standard.During its operation,a Majorana transition frequency shift will occur once a magnetic field at some special locations along the atomic trajectory is si... The caesium atomic fountain clock is a primary frequency standard.During its operation,a Majorana transition frequency shift will occur once a magnetic field at some special locations along the atomic trajectory is singular.In this study,by developing a physical model,we analyzed the magnetic field requirements for atomic adiabatic transition and calculated the influence of the Majorana atomic transition on the atomic state via a quantum method.Based on the simulation results for the magnetic field in the fountain clock,we applied the Monte Carlo method to simulate the relationship between the Majorana transition frequency shift and the magnetic field at the entrance of the magnetic shielding,as well as the initial atomic population.Measurement of the Majorana transition frequency shift was realized by state-selecting asymmetrically populated atoms.The relationship between the Majorana transition frequency shift and the axial magnetic field at the entrance of the magnetic shielding was obtained.The measured results were essentially consistent with the calculated results.Thus,the magnetic field at the entrance of the magnetic shielding was configured,and the Majorana transition frequency shift of the fountain clock was calculated to be 4.57×10^(-18). 展开更多
关键词 caesium atomic fountain clock Majorana transition frequency shift magnetic field initial atomic population
下载PDF
Laser frequency offset-locking using electromagnetically induced transparency spectroscopy of (85)Rb in magnetic field 被引量:1
8
作者 王汉睦 成红 +3 位作者 张珊珊 辛培培 徐子珊 刘红平 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第9期296-300,共5页
We have experimentally offset-locked the frequencies of two lasers using electromagnetically induced transparency(EIT) spectroscopy of ^(85)Rb vapor with a buffer gas in a magnetic field at room temperature. The m... We have experimentally offset-locked the frequencies of two lasers using electromagnetically induced transparency(EIT) spectroscopy of ^(85)Rb vapor with a buffer gas in a magnetic field at room temperature. The magnetic field is generated by a permanent magnet mounted on a translation stage and its field magnitude can be varied by adjusting the distance between the magnet and Rb cell, which maps the laser locking frequency to the space position of the magnet. This frequency-space mapping technique provides an unambiguous daily laser frequency detuning operation with high accuracy.A repeatability of less than 0.5 MHz is achieved with the locking frequency detuned up to 184 MHz when the magnetic field varies from 0 up to 80 G. 展开更多
关键词 electromagnetically induced transparency offset-lock rubidium atom magnetic field
下载PDF
Frequency-locking and threshold current-lowering effects of a quantum cascade laser and an application in gas detection field
9
作者 陈伟根 万福 +2 位作者 邹经鑫 顾朝亮 周渠 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第2期165-169,共5页
In this paper,the frequency-locking and threshold current-lowering effects of a quantum cascade laser are studied and achieved.Combined with cavity-enhanced absorption spectroscopy,the noninvasive detection of H_2 wit... In this paper,the frequency-locking and threshold current-lowering effects of a quantum cascade laser are studied and achieved.Combined with cavity-enhanced absorption spectroscopy,the noninvasive detection of H_2 with a prepared concentration of 500 ppm in multiple dissolved gases is performed and evaluated.The high frequency selectivity of 0.0051 cm^-1 at an acquisition time of 1 s allows the sensitive detection of the(1-0) S(l) band of H_2 with a high accuracy of(96.53±0.29)%and shows that the detection limit to an absorption line of 4712.9046 cm^-1 is approximately(17.26±0.63) ppm at an atmospheric pressure and a temperature of 20 ℃. 展开更多
关键词 quantum cascade laser frequency locking threshold current lowering cavity-enhanced absorptionspectroscopy
下载PDF
STUDY ON TEMPERATURE FIELD INDUCED IN HIGH FREQUENCY INDUCTION HEATING 被引量:18
10
作者 H. Shen Z.Q. Yao Y.J. Shi J. Hu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2006年第3期190-196,共7页
A mathematical model was established for the temperature field developed during high frequency induction heating (HFIH) by Maxwell's equations. It required solving the coupled equations of the electromagnetic and t... A mathematical model was established for the temperature field developed during high frequency induction heating (HFIH) by Maxwell's equations. It required solving the coupled equations of the electromagnetic and temperature fields. The numerical simudation was performed using FEMLAB. The comparison of the calculations using the proposed model with experimental results showed a very good correlation. The effects of the heating parameters in high frequency induction such as the distance between the plate and the coil, the applied current, the frequency, and the turns of the coil on the temperature profiles developed in the plate were also discussed using the established model. 展开更多
关键词 high frequency induction temperature field numerical simudation
下载PDF
The Dynamic Volt-Ampere Characteristics of a Vacuum Arc at Intermediate-Frequency Under a Transverse Magnetic Field 被引量:6
11
作者 朱立颖 武建文 +1 位作者 刘斌 冯英 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第1期30-36,共7页
In this study, the changes of a vacuum arc's appearance were observed and the volt-ampere characteristics of the vacuum arc at intermediate frequency were analyzed under a transverse magnetic field (TMF). The TMF a... In this study, the changes of a vacuum arc's appearance were observed and the volt-ampere characteristics of the vacuum arc at intermediate frequency were analyzed under a transverse magnetic field (TMF). The TMF and phase shift time were calculated by using the TMF contact model and the large phase shift of the magnetic field at a higher frequency was conductive to the dispersion process of residual plasma. The arc velocity was higher at 800 Hz than at 400 Hz. It can be inferred that TMF will encourage arc movement at 800 Hz. Moreover, the arc movement has an impact on the arc voltage. Because of the increasing length of the arc column with a high arc velocity, the elongated arc causes the arc voltage to increase. Specifically, the volt-ampere characteristics of the vacuum arc are divided into three stages in this paper. The higher the frequency, the greater the initial rate of rise in the arc voltage and the larger the area surrounded by arc volt-ampere characteristics. The correlations between the arc voltage and the amplitude and frequency of the current are also presented. 展开更多
关键词 arc appearance arc volt-ampere characteristic transverse magnetic field(TMF) intermediate frequency vacuum arc phase shift
下载PDF
EFFECT OF LOW-FREQUENCY ELECTROMAGNETIC FIELD ON THE AS-CASTING MICROSTRUCTURES AND MECHANICAL PROPERTIES OF HDC 2024 ALUMINUM ALLOY 被引量:4
12
作者 Q.F. Zhu Z.H. Zhao J.Z. Cui Y.B. Zuo F. Qu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2008年第3期205-210,共6页
The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were pro... The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were produced by the conventional horizontal chill casting process and low frequency electromagnetic horizontal chill casting processre- spectively. The as-cast structures and the mechanical property of the ingots were examined. The results showed that the low frequency electromagnetic field could sub- stantially refine the microstructures and pronouncedly reduce the macrosegregation in the horizontal direct chill casting process. Moreover, the surface quality of the ingot was prominently improved by the low frequency electromagnetic field. The fracture strength and elongation percentage of the ingot was increased with the low frequency electromagnetic field. 展开更多
关键词 Horizontal direct chill casting Low frequency electromagnetic field 2024 aluminum alloy MICROSTRUCTURES MACROSEGREGATION
下载PDF
Experimental Verification and Research for the Distortion in the Integrated Frequency Responses of the High-Pressure Sealed Cabin and Magnetic Field Sensor 被引量:4
13
作者 邓明 魏文博 +3 位作者 金胜 叶高峰 张启升 景建恩 《Journal of China University of Geosciences》 SCIE CSCD 2007年第4期310-319,共10页
Although magnetotelluric sounding method applied to the land is advanced, there are many difficulties when it is applied to marine environment, one of which is how to lay magnetic field sensors down to the seafloor to... Although magnetotelluric sounding method applied to the land is advanced, there are many difficulties when it is applied to marine environment, one of which is how to lay magnetic field sensors down to the seafloor to complete measurements. To protect the magnetic field sensors from intense erosion and high pressure, suitable high-pressure sealed cabins must be designed to load them. For the consideration of magnetic measurement and marine operation, the sealed pressure cabin should be nonmagnetic and transportable. Among all optional materials, LC4 super.hard aluminum alloy has the highest performance of price/quality ratio to make the sealed pressure cabin. However, it does not mean that the high-pressure sealed cabin made using LC4 will be perfect in performance. In fact, because of its weak magnetism, the pressure cabin made using LC4 has distorting effect on frequency responses of the magnetic field sensors sealed in it. This distorting effect does not affect the use of the magnetic field sensor, but if we want to eliminate its effect, we should study it by experimental measurements. In our experiment tests, frequency sweep magnetic field as excitation signal was used, and then responses of the magnetic field sensor before and after being loaded into the high-pressure sealed cabin were measured. Finally, normalized abnormal curves for the frequency responses were obtained, through which we could show how the high-pressure sealed cabin produces effects on the responses of the magnetic field sensor. Experimental results suggest that the response distortion induced by the sealed pressure cabin appears on mid- and high-frequency areas. Using experimental results as standardization data, the frequency responses collected from seafloor magnetotelluric measurements can be corrected to restore real information about the seafloor field source. 展开更多
关键词 marine magnetotellurics magnetic field sensor high-pressure sealed cabin frequency response experimental test
下载PDF
Motion and Splitting of Vacuum Arc Column in Transverse Magnetic Field Contacts at Intermediate—Frequency 被引量:4
14
作者 朱立颖 武建文 蒋原 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第5期454-459,共6页
Arc motion and splitting of vacuum arc at intermediate frequency(400-800 Hz) were investigated under transverse magnetic field(TMF).The experiment was performed on cup-type TMF contacts with contact diameter of 40... Arc motion and splitting of vacuum arc at intermediate frequency(400-800 Hz) were investigated under transverse magnetic field(TMF).The experiment was performed on cup-type TMF contacts with contact diameter of 40 mm and a contact gap of 4 mm in a single-frequency circuit.With high-speed photography we characterized the arc appearance at different arc currents from 3.3 kA-rms to 10 kA-rms at intermediate frequencies.As arc current increases from3.3 kA-rms to 10 kA-rms the arc appearance changes obviously.When current value is 3.3 kArms(current frequency 400-800 Hz),there is almost no splitting arc;when the current exceeds5 kA-rms(current frequency 400-800 Hz),the arc rotates at a speed above 20 m/s,accompanied by an observable splitting arc.The splitting arc could be observed at different frequencies and the arc-voltage had no noises when splitting occurred.The motion direction and the velocity of arc column were studied.Finally,the formation of a split arc was discussed. 展开更多
关键词 arc motion split arc transverse magnetic field(TMF) intermediate frequency vacuum arc vacuum arc arc appearance
下载PDF
SIMULATION OF TEMPERATURE FIELD IN ULTRA-HIGH FREQUENCY INDUCTION HEATING AND VERIFICATION 被引量:2
15
作者 李奇林 徐九华 苏宏华 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2013年第2期155-161,共7页
An experimental and numerical study on the temperature field induced in the ultra-high frequency induction heating is carried out.With an aim of predicting the thermal history of the workpiece,the influence factors of... An experimental and numerical study on the temperature field induced in the ultra-high frequency induction heating is carried out.With an aim of predicting the thermal history of the workpiece,the influence factors of temperature field,such as the induction frequency,the dimension of coil and the gap between coil and workpiece,are investigated considering temperature-dependent material properties by using FLUX 2Dsoftware.The temperature field characteristic in ultra-high induction heating is obtained and discussed.The numerical values are compared with the experimental results.A good agreement between them is observed with 7.9% errors. 展开更多
关键词 ultra-high frequency induction heating temperature field FLUX 2Dsoftware
下载PDF
A combined magnetic field stabilization system for improving the stability of 40Ca^(+) optical clock
16
作者 曾孟彦 马子晓 +6 位作者 胡如明 张宝林 郝艳梅 张华青 黄垚 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期226-231,共6页
Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise supp... Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise suppression system. On the one hand, we have optimized the magnetic shielding performance of the portable optical clock by reducing its apertures and optimizing its geometry;on the other hand, we have introduced an active magnetic field noise suppression system to further suppress the magnetic field noise experienced by the ions. These efforts reduced the ambient magnetic field noise by about 10000 times, significantly reduced the linewidth of the clock transition spectrum, improved the stability of the portable40Ca+optical clock, and created the conditions for using portable optical clocks in non-laboratory magnetic field environments. This active magnetic field suppression scheme has the advantages of simple installation and wide applicability. 展开更多
关键词 40Ca^(+)optical clock magnetic field compensation frequency stability
下载PDF
Effects of Exposure to Extremely Low Frequency Electro-magnetic Fields on Circadian Rhythms and Distribution of Some Leukocyte Differentiation Antigens in Dairy Cows 被引量:1
17
作者 CALOGERO STELLETTA PAOLA DE NARDO +4 位作者 FRANCESCO SANTIN GIUSEPPE BASSO BARBARA MICHIELOTTO GIUSEPPE PICCIONE MASSIMO MORGANTE 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第2期164-170,共7页
Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The stu... Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The study was carded out in 5 cows exposed to 1.98-3.28 μT of ELFEMFs and in 5 control cows exposed to 0.2-0.7 μT of ELFEMFs. Following haematological and immunologic parameters were measured in both groups: WBC, CD45R, CD6, CD4, CD8, CD21, and CD11B leukocyte antigen expression. Results Some of the haematological and immunologic parameters under investigation were similar in both groups. However, CD8 (T lymphocyte surface antigen) was higher in the exposed group (1.35 ±0.120 vs 0.50 ±0.14×10^3/mL). Furthermore, the CD4/CD8 ratio (0.84 ±0.05 and 2.19±0.16 for exposed and not exposed cows respectively) and circadian rhythm were different between the two groups. Conclusion Exposure to ELFEMFs is responsible of the abnormal temporal variations and distribution of some haematological and immunological parameters in dairy cows. 展开更多
关键词 Electro-magnetic fields Low frequency LEUKOCYTE Circadian rhythm Dairy cow
下载PDF
Optimal Microwave Radiation Field Parameters for Mercury Ion Microwave Frequency Standards 被引量:2
18
作者 杨智慧 柳浩 +5 位作者 何跃宏 汪漫 万涌泉 陈义和 佘磊 李交美 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第6期21-24,共4页
We propose a method to determine the optimal power of the microwave resonance transition that simultaneously improves the signal-to-noise ratio and reduces line width based on saturation broadening theory and experime... We propose a method to determine the optimal power of the microwave resonance transition that simultaneously improves the signal-to-noise ratio and reduces line width based on saturation broadening theory and experiment. Saturation broadening spectra of the ground state hyperfine transition of trapped 199Hg+ ions are measured and analyzed. The value of the optimal microwave power is obtained by using the proposed method and is verified. Rabi oscillations decay spectra of trapped 199Hg+ ions are observed and the optimal microwave irradiation time for the maximum transition signal intensity is determined. This work will help to improve the short-term frequency stability of the mercury ion microwave frequency standard. 展开更多
关键词 of on IT Optimal Microwave Radiation field Parameters for Mercury Ion Microwave frequency Standards DBM IS for
下载PDF
Determination of the Base Optimum Thickness of Back Illuminated (n+/p/p+) Bifacial Silicon Solar Cell, by Help of Diffusion Coefficient at Resonance Frequency
19
作者 Mohamed Yaya Teya Ousmane Sow +5 位作者 Khady Loum Ibrahima Diatta Gora Diop Youssou Traore Mamadou Wade Gregoire Sissoko 《Journal of Electromagnetic Analysis and Applications》 CAS 2023年第2期13-24,共12页
The bifacial silicon solar cell subjected to a magnetic field, is illuminated by the back side by a monochromatic light in frequency modulation, with high absorption, At minority carriers diffusion coefficient resonan... The bifacial silicon solar cell subjected to a magnetic field, is illuminated by the back side by a monochromatic light in frequency modulation, with high absorption, At minority carriers diffusion coefficient resonance frequency, a graphical study of the expressions of recombination velocity on the rear side is carried out. The optimum thickness of the base of the bifacial solar cell is deduced for each resonance frequency. 展开更多
关键词 Bifacial Silicon Solar Cell frequency Magnetic field Wavelength-Recombination Velocity Base Thickness
下载PDF
Phase-coherence dynamics of frequency-comb emission via high-order harmonic generation in few-cycle pulse trains
20
作者 梁畅通 张晶晶 李鹏程 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期205-211,共7页
Frequency-comb emission via high-order harmonic generation(HHG)provides an alternative method for the coherent vacuum ultraviolet(VUV)and extreme ultraviolet(XUV)radiation at ultrahigh repetition rates.In particular,t... Frequency-comb emission via high-order harmonic generation(HHG)provides an alternative method for the coherent vacuum ultraviolet(VUV)and extreme ultraviolet(XUV)radiation at ultrahigh repetition rates.In particular,the temporal and spectral features of the HHG were shown to carry profound insight into frequency-comb emission dynamics.Here we present an ab initio investigation of the temporal and spectral coherence of the frequency comb emitted in HHG of He atom driven by few-cycle pulse trains.We find that the emission of frequency combs features a destructive and constructive coherences caused by the phase interference of HHG,leading to suppression and enhancement of frequency-comb emission.The results reveal intriguing and substantially different nonlinear optical response behaviors for frequency-comb emission via HHG.The dynamical origin of frequency-comb emission is clarified by analyzing the phase coherence in HHG processes in detail.Our results provide fresh insight into the experimental realization of selective enhancement of frequency comb in the VUV–XUV regimes. 展开更多
关键词 high-order harmonic generation frequency comb time-dependent Schro¨dinger equation intense laser field systems
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部