Objective To investigate the flow distribution in plate fin heat exchangers and optimize the design of header configuration for plate fin heat exchangers. Methods A mathematical model of header was proposed. The e...Objective To investigate the flow distribution in plate fin heat exchangers and optimize the design of header configuration for plate fin heat exchangers. Methods A mathematical model of header was proposed. The effects of the header configuration on the flow distribution in plate fin heat exchangers were investigated by CFD. The second header configuration with a two stage distributing structure was brought forward to improve the performance of flow distribution. Results It is found that the flow maldistribution is very serious in the direction of header length for the conventional header used in industry. The numerical predictions indicate that the improved header configurations can effectively improve the performance of flow distribution in plate fin heat exchangers. Conclusion The numerical simulation confirms that CFD should be a suitable tool for predicting the flow distribution. The method has a wide variety of applications in the design of plate fin heat exchangers.展开更多
In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between t...In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between the round inner tube and the elliptic outer tube,and it simultaneously exchanges heat with the cooling water in the inner tube,the spray water,and the cooling air flowing past the outer tube.Using field measurement for the traditional round finned tube evaporative condenser in the Futong Metro Station of Line 14 in Beijing,China,the theoretical heat transfer performance of the annular elliptic finned tube evaporative condenser was analyzed and simulated.Compared with a round finned tube heat exchanger,the heat exchange capacity of the annular elliptic finned tube increased by 2.34%to 9.28%;the total heat transfer coefficient increased by 47.42%,and the power consumption of the fan in the air-conditioning system with an annular elliptic finned tube heat exchanger decreased by 11.18%to 14.65%.Therefore,the energy-saving performance and the heat transfer performance of the new annular elliptic finned tube heat exchanger were enhanced compared to the round finned tube heat exchanger.展开更多
文摘Objective To investigate the flow distribution in plate fin heat exchangers and optimize the design of header configuration for plate fin heat exchangers. Methods A mathematical model of header was proposed. The effects of the header configuration on the flow distribution in plate fin heat exchangers were investigated by CFD. The second header configuration with a two stage distributing structure was brought forward to improve the performance of flow distribution. Results It is found that the flow maldistribution is very serious in the direction of header length for the conventional header used in industry. The numerical predictions indicate that the improved header configurations can effectively improve the performance of flow distribution in plate fin heat exchangers. Conclusion The numerical simulation confirms that CFD should be a suitable tool for predicting the flow distribution. The method has a wide variety of applications in the design of plate fin heat exchangers.
基金The work was supported by the Natural Science Foundation of Shaanxi Province(No.2018JM5084)“the 13th Five-Year”National Science and Technology Major Project of China(No.2017YFC0702202)+1 种基金the Shaanxi Key Science and Technology Innovative Tea m Project(No.2016KCT-22)the Fundamental Research Funds for the Central Universities(CHD300102289203).
文摘In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between the round inner tube and the elliptic outer tube,and it simultaneously exchanges heat with the cooling water in the inner tube,the spray water,and the cooling air flowing past the outer tube.Using field measurement for the traditional round finned tube evaporative condenser in the Futong Metro Station of Line 14 in Beijing,China,the theoretical heat transfer performance of the annular elliptic finned tube evaporative condenser was analyzed and simulated.Compared with a round finned tube heat exchanger,the heat exchange capacity of the annular elliptic finned tube increased by 2.34%to 9.28%;the total heat transfer coefficient increased by 47.42%,and the power consumption of the fan in the air-conditioning system with an annular elliptic finned tube heat exchanger decreased by 11.18%to 14.65%.Therefore,the energy-saving performance and the heat transfer performance of the new annular elliptic finned tube heat exchanger were enhanced compared to the round finned tube heat exchanger.