期刊文献+
共找到119篇文章
< 1 2 6 >
每页显示 20 50 100
Flash X-ray radiography technique to study the high velocity impact of soft projectile on E-glass/epoxy composite material
1
作者 B.Venkata Ramudu C.Jayarami Reddy V.Madhu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第2期216-226,共11页
In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR ... In the present paper, the high velocity impact of 9 mm soft lead projectile on 10 mm and 30 mm thick Eglass/epoxy composites was studied using a 450 kV Flash X-ray radiography(FXR) system. The basic parameters of FXR imaging, such as effect of ratio of target to film(TF) and source to target(ST) distances and X-ray penetration thickness of the composite material were optimized based on clarity and the actual dimensions of the objects. The optimized parameters were used in the FXR imaging of the ballistic event of 9 mm soft projectile on E-glass/epoxy composite. The real time deformation patterns of both the projectile and composite target during the ballistic impact were captured and studied at different time intervals. The notable failure modes of the 10 mm thick target with time include fibre breakage, bulging on the back side, delamination, recovery of the bulging, reverse bulging and its recovery. However, with increase in thickness of the target to 30 mm the only failure mechanism observed is the breaking of fibres. The ballistic impact event was also numerically simulated using commercially available LS-DYNA software. The numerically simulated deformation patterns of the projectile and target at different time intervals are closely matching with the corresponding radiographic images. 展开更多
关键词 flash x-ray radiography E-Glass/epoxy composite BALLISTIC impact Numerical simulation
下载PDF
Radiography Image Classification Using Deep Convolutional Neural Networks
2
作者 Ahmad Chowdhury Haiyi Zhang 《Journal of Computer and Communications》 2024年第6期199-209,共11页
Research has shown that chest radiography images of patients with different diseases, such as pneumonia, COVID-19, SARS, pneumothorax, etc., all exhibit some form of abnormality. Several deep learning techniques can b... Research has shown that chest radiography images of patients with different diseases, such as pneumonia, COVID-19, SARS, pneumothorax, etc., all exhibit some form of abnormality. Several deep learning techniques can be used to identify each of these anomalies in the chest x-ray images. Convolutional neural networks (CNNs) have shown great success in the fields of image recognition and image classification since there are numerous large-scale annotated image datasets available. The classification of medical images, particularly radiographic images, remains one of the biggest hurdles in medical diagnosis because of the restricted availability of annotated medical images. However, such difficulty can be solved by utilizing several deep learning strategies, including data augmentation and transfer learning. The aim was to build a model that would detect abnormalities in chest x-ray images with the highest probability. To do that, different models were built with different features. While making a CNN model, one of the main tasks is to tune the model by changing the hyperparameters and layers so that the model gives out good training and testing results. In our case, three different models were built, and finally, the last one gave out the best-predicted results. From that last model, we got 98% training accuracy, 84% validation, and 81% testing accuracy. The reason behind the final model giving out the best evaluation scores is that it was a well-fitted model. There was no overfitting or underfitting issues. Our aim with this project was to make a tool using the CNN model in R language, which will help detect abnormalities in radiography images. The tool will be able to detect diseases such as Pneumonia, Covid-19, Effusions, Infiltration, Pneumothorax, and others. Because of its high accuracy, this research chose to use supervised multi-class classification techniques as well as Convolutional Neural Networks (CNNs) to classify different chest x-ray images. CNNs are extremely efficient and successful at reducing the number of parameters while maintaining the quality of the primary model. CNNs are also trained to recognize the edges of various objects in any batch of images. CNNs automatically discover the relevant aspects in labeled data and learn the distinguishing features for each class by themselves. 展开更多
关键词 CNN radiography Image Classification R Keras Chest x-ray Machine Learning
下载PDF
Flash X-ray cinematography analysis of dwell and penetration of smallcaliber projectiles with three types of SiC ceramics 被引量:2
3
作者 Elmar STRASSBURGER Steffen BAUER +1 位作者 Steffen WEBER Heiner GEDON 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2016年第3期277-283,共7页
In order to improve the performance of ceramic composite armor it is essential to know the mechanisms during each phase of the projectile–target interaction and their influence on the penetration resistance.Since the... In order to improve the performance of ceramic composite armor it is essential to know the mechanisms during each phase of the projectile–target interaction and their influence on the penetration resistance.Since the view on the crater zone and the tip of a projectile penetrating a ceramic is rapidly getting obscured by damaged material,a flash X-ray technique has to be applied in order to visualize projectile penetration.For this purpose,usually several flash X-ray tubes are arranged around the target and the radiographs are recorded on film.At EMI a flash X-ray imaging method has been developed,which provides up to eight flash radiographs in one experiment.A multi-anode 450 k V flash X-ray tube is utilized with this method.The radiation transmitted through the target is then detected on a fluorescent screen.The fluorescent screen converts the radiograph into an image in the visible wavelength range,which is photographed by means of a high-speed camera.This technique has been applied to visualize and analyze the penetration of 7.62 mm AP projectiles into three different types of Si C ceramics.Two commercial Si C grades and MICASIC(Metal Infiltrated Carbon derived Si C),a C-Si Si C ceramic developed by DLR,have been studied.The influences,not only of the ceramic but also the backing material,on dwell time and projectile erosion have been studied.Penetration curves have been determined and their relevance to the ballistic resistance is discussed. 展开更多
关键词 BALLISTIC resistance DWELL flash x-ray CINEMATOGRAPHY SiC ceramics
下载PDF
Monte Carlo simulation for bremsstrahlung and photoneutron yields in high-energy x-ray radiography 被引量:1
4
作者 许海波 彭现科 陈朝斌 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第6期213-220,共8页
This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray ... This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems. 展开更多
关键词 x-ray radiography BREMSSTRAHLUNG PHOTONEUTRON energy spectrum angular distribution
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
5
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source radiography
下载PDF
A Simulation Study on the Flash X-Ray Spectra Spatial Distribution
6
作者 徐修峰 李世平 +4 位作者 曹宏睿 肖锐 陈楠 章林文 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1165-1168,共4页
Accurate measurement of flash X-ray energy spectra plays an important role in highenergy flash radiography. In this paper, by virtue of Geant4 toolkit, we simulated the generation and transport of X-ray photons result... Accurate measurement of flash X-ray energy spectra plays an important role in highenergy flash radiography. In this paper, by virtue of Geant4 toolkit, we simulated the generation and transport of X-ray photons resulting from the interaction of a high-energy electron beam with a solid thin target. We obtained the flash X-ray energy spectral distribution in the plane perpendicular to the electron beam incident direction. Our results indicate that the flash X- ray spectrum is almost uniform in the azimuthal direction but is quite different in the radius direction. Specifically, as the radius increases, the incident X-ray dose decreases significantly. Our work paves a theoretical basis for selecting appropriate structures and layout of the spectrometer and facilitates the measurements of flash X-ray energy spectra. 展开更多
关键词 GEANT4 flash x-ray spectra spatial distribution
下载PDF
X-Pinches as Broadband Sources of X-Rays for Radiography
7
作者 Tatiana Shelkovenko Sergey Pikuz David Hammer 《Journal of Biomedical Science and Engineering》 2015年第11期747-755,共9页
Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral ra... Two methods of using the X-pinch as a source of X-ray radiation for radiography of biological objects are presented. X-pinches are found to be a very flexible method for generation of radiation over a wide spectral range and provide a high spatial and temporal resolution. 展开更多
关键词 X-PINCH x-ray HOT SPOT Electron Beam Point-Projection radiography Biological Object
下载PDF
高能闪光照相阵列屏非一致性响应校正技术
8
作者 管永红 唐志鹏 +2 位作者 景越峰 危才华 刘进 《强激光与粒子束》 CAS CSCD 北大核心 2024年第8期76-81,共6页
阵列屏采用大量独立晶柱组合而成限制了可见光在转换屏内的扩散,能够在提高X光转换效率的同时保证照相系统有较高的空间分辨能力,是高能闪光照相系统中的重要器件。阵列屏由于各晶柱之间的转换系数不同而导致接收图像中存在非一致响应现... 阵列屏采用大量独立晶柱组合而成限制了可见光在转换屏内的扩散,能够在提高X光转换效率的同时保证照相系统有较高的空间分辨能力,是高能闪光照相系统中的重要器件。阵列屏由于各晶柱之间的转换系数不同而导致接收图像中存在非一致响应现象,必须将其校正才能对图像进行有效判读。研究了中阵列屏接收图像中非一致响应现象的校正方法,首先使用平板照相获得空场图像,然后对实验图像和空场图像扣除暗电流本底和消除脉冲噪声,最后将实验图像与空场图像进行像素相除运算。针对强振动环境下空场图像与实验图像不匹配问题,提出对空场图像进行位移的方法以实现空场图像与实验图像的重新匹配,采用校正后图像的标准差数据来判断两者的匹配性。实验结果表明位移后的空场图像能够校正强振动环境下阵列屏图像的非一致性响应。 展开更多
关键词 高能闪光照相 阵列屏 图像处理 非一致响应 校正
下载PDF
JMCT3.0蒙特卡罗质子及低能光子/电子输运功能开发及检验
9
作者 谭笑 邓力 +5 位作者 张玲玉 李瑞 付元光 史敦福 刘鹏 杨超 《强激光与粒子束》 CAS CSCD 北大核心 2024年第9期127-133,共7页
高分辨率通用型三维多粒子输运蒙特卡罗软件JMCT能够模拟任意复杂几何系统的中子/光子/电子/质子/分子/光辐射/大气输运问题,支持数十万核的多级并行,已广泛用于辐射屏蔽、反应堆临界安全分析、核探测及核医学等领域。JMCT已升级到3.0版... 高分辨率通用型三维多粒子输运蒙特卡罗软件JMCT能够模拟任意复杂几何系统的中子/光子/电子/质子/分子/光辐射/大气输运问题,支持数十万核的多级并行,已广泛用于辐射屏蔽、反应堆临界安全分析、核探测及核医学等领域。JMCT已升级到3.0版本,相比2.0版本,3.0版本新增了13项功能,改进发展了8种算法,通过对低层JCOGIN框架的优化,计算效率提高30%~600%。新功能主要用于图像诊断、闪光照相、光辐射及大气输运的模拟。JMCT3.0开发了质子、低能光子/电子及分子模拟功能,通过基准检验,验证了算法的正确有效性。 展开更多
关键词 蒙特卡罗 质子 低能光子及电子输运 闪光照相 JMCT
下载PDF
Development of a monochromatic crystal backlight imager for the recent double-cone ignition experiments
10
作者 张成龙 张翌航 +11 位作者 远晓辉 张喆 徐妙华 戴羽 董玉峰 谷昊琛 刘正东 赵旭 李玉同 李英骏 朱健强 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期40-45,共6页
We developed a monochromatic crystal backlight imaging system for the double-cone ignition(DCI) scheme, employing a spherically bent quartz crystal. This system was used to measure the spatial distribution and tempora... We developed a monochromatic crystal backlight imaging system for the double-cone ignition(DCI) scheme, employing a spherically bent quartz crystal. This system was used to measure the spatial distribution and temporal evolution of the head-on colliding plasma from the two compressing cones in the DCI experiments. The influence of laser parameters on the x-ray backlighter intensity and spatial resolution of the imaging system was investigated. The imaging system had a spatial resolution of 10 μm when employing a CCD detector. Experiments demonstrated that the system can obtain time-resolved radiographic images with high quality, enabling the precise measurement of the shape, size, and density distribution of the plasma. 展开更多
关键词 double-cone ignition(DCI) spatial resolution x-ray radiography
下载PDF
Simulation study on characteristics of information extraction in multiple-image radiography
11
作者 Cui Zhang Xiao-Dong Pan +4 位作者 Jing-Jie Ding Hong-Jie Shang Zhang-Gu Chen Yong-Fan Pu Gong-Ping Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第5期87-97,共11页
Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were adde... Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction. 展开更多
关键词 x-ray imaging Phase CONTRAST ROCKING CURVE Multiple-image radiography
下载PDF
Enhanced K-Edge Radiography Using a High-Spatial-Resolution Cadmium Telluride Array Detector
12
作者 Manabu Watanabe Eiichi Sato +5 位作者 Yasuyuki Oda Hodaka Moriyama Osahiko Hagiwara Hiroshi Matsukiyo Toshiyuki Enomoto Shinya Kusachi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期296-307,共12页
To confirm the imaging effect of a dual-energy (DE) cadmium telluride (CdTe) array detector (XCounter, Actaeon) and to perform fundamental studies on DE computed tomography, we performed enhanced K-edge radiography us... To confirm the imaging effect of a dual-energy (DE) cadmium telluride (CdTe) array detector (XCounter, Actaeon) and to perform fundamental studies on DE computed tomography, we performed enhanced K-edge radiography using iodine (I) and gadolinium (Gd) media. DE radiography was performed using an X-ray generator with a 0.1-mm-diam-focus tube and a 0.5-mm-thick beryllium window, a 1.0-mm-thick aluminum filter for absorbing extremely low-energy photons, and the CdTe array detector with pixel dimensions of 0.1 × 0.1 mm2. Each pixel has a charge-sensitive amplifier and a dual-energy counter, and the event pulses from the amplifier are sent to the counter to determine two threshold energies. The tube current was a maximum value of 0.50 mA, and the tube voltages for I- and Gd-K-edge radiograms were 60 and 80 kV, respectively. In the I-K-edge radiography of a dog-heart phantom at an energy range of 33 - 60 keV, the muscle density increased, and fine coronary arteries were visible. Utilizing Gd-K-edge radiography of a rabbit head phantom at an energy range of 50 - 80 keV, the muscle density increased, and fine blood vessels in the nose were observed at high contrasts. Using the DE array detector, we confirmed the image-contrast variations with changes in the threshold energy. 展开更多
关键词 x-ray Photon COUNTING CdTe-Array Detector DUAL-ENERGY Energy-Dispersive radiography I-K-Edge radiography Gd-K-Edge radiography
下载PDF
A Derived Exposure Chart for Computed Radiography in a Negroid Population
13
作者 Thomas Adejoh Odira C. Ewuzie +2 位作者 Joshua K. Ogbonna Stanley O. Nwefuru Nnamdi C. Onuegbu 《Health》 CAS 2016年第10期953-958,共6页
Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiograp... Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations. 展开更多
关键词 Computed radiography EXPOSURE RADIOGRAPHER kVp Tube Current x-ray
下载PDF
Economic Evaluation of Conventional Radiography with Film and Computed Radiography: Applied at BMC
14
作者 Usama Ali Rahoma Pavan Kumar Chundi 《Advances in Computed Tomography》 2012年第3期23-29,共7页
Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances i... Conventional radiography with film (CRF) has been in use for diagnostic purposes for a long time now. It has proved to be a great assert for the radiographers in assessing various abnormalities. With recent advances in technology it is now possible to have digital solutions for radiography problems at a very cost effective, environment friendly and also with better image quality in certain applications when compared to CRF. Rather than using a CRF a computed radiography (CR) uses imaging plates to capture the image. The imaging plate contains photosensitive phosphors which contain the latent image. Later this plate is introduced into a reader which is then converted into a digital image. The major advantage and the cost effective element of this system is the ability to reuse the imaging plates unlike the photographic film where in only a single image can be captured and cannot be reused. The computed radiography drastically reduces the cost by eliminating the use of chemicals like film developers and fixers and also the need for a storage room. It also helps to reduce the costs that are involved in the disposal of wastes due to conventional radiography. This paper investigates whether it is cost effective to use computed radiography over film based system at Al-Batnan Medical Center (BMC), Tobruk, Libya by using Cost Benefit Analysis (CBA). Apart from the initial cost of the CR System, based on the data collected from the center, from the year 2008 to 2012 (until June 2012) a total of 581,566 images were produced with the total cost incurred using film based system being USD 4,652,528. If the same number of images were produced using a CR system the total cost incurred would have been USD 82,600. Taking into consideration the cost of a new CR system to be USD 120,000 the overall cost of producing these images is USD 202,600. It is observed that an amount of USD 4,449,928 could have been saved over the period of 5 years starting from 2008 to 2012 by using the CR system at BMC. Using Cost Benefit Analysis, the average value of the net difference between the costs and benefits for the conventional film based system is ?83.38 where as for the Computed System it is 22.06. Based on the principles of Cost Benefit Analysis it can be concluded that the system with a net positive difference is more cost beneficial than the other. With the help of the above two analysis it can be concluded that the use of computed radiography is definitely more cost effective for use at BMC, when compared to the conventional x-ray radiography. 展开更多
关键词 RADIOGRAPHIC FILM x-ray radiography COMPUTED radiography Cost BENEFIT Analysis
下载PDF
0.45~4MV杆箍缩二极管阳极等离子体研究
15
作者 屈俊夫 冯元伟 +2 位作者 耿力东 马勋 李洪涛 《原子能科学技术》 EI CAS CSCD 北大核心 2023年第3期655-665,共11页
为提升对杆箍缩二极管物理机制的认识,提升模拟算法的准确性,使用相空间文件作为信息传递媒介,将PIC与蒙特卡罗计算方法相结合,实现了杆箍缩二极管从加载电压到剂量计算全过程模拟。本工作给出了PIC模拟计算中的阳极等离子体生成函数,... 为提升对杆箍缩二极管物理机制的认识,提升模拟算法的准确性,使用相空间文件作为信息传递媒介,将PIC与蒙特卡罗计算方法相结合,实现了杆箍缩二极管从加载电压到剂量计算全过程模拟。本工作给出了PIC模拟计算中的阳极等离子体生成函数,使得数值计算模型能在0.45~4 MV的电压范围内,对杆箍缩二极管的电流、剂量进行准确的计算,与实验结果相比,计算结果相对误差控制在20%以内。利用获得验证的PIC模型,以加载电压为1 MV为例,用模拟手段对等离子体生成速率与电子运动状态之间的关系进行了研究,总结了电子箍缩的物理特性。相较于先前模拟工作仅能给出趋势性的预测结果,该模型的准确性与通用性均获得提升,同时等离子体对电子运动状态影响的研究结果为新型强流X射线二极管的研发提供了基础。 展开更多
关键词 杆箍缩二极管 闪光照相 蒙特卡罗模拟 PIC模拟
下载PDF
High-resolution X-ray flash radiography of Ti characteristic lines with multilayer Kirkpatrick–Baez microscope at the Shenguang-ⅡUpdate laser facility 被引量:4
16
作者 Shengzhen Yi Feng Zhang +3 位作者 Qiushi Huang Lai Wei Yuqiu Gu Zhanshan Wang 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2021年第3期61-67,共7页
High-resolution X-ray flash radiography of Ti characteristic lines with a multilayer Kirkpatrick-Baez microscope was developed on the Shenguang-Ⅱ(SG-Ⅱ)Update laser facility.The microscope uses an optimized multilaye... High-resolution X-ray flash radiography of Ti characteristic lines with a multilayer Kirkpatrick-Baez microscope was developed on the Shenguang-Ⅱ(SG-Ⅱ)Update laser facility.The microscope uses an optimized multilayer design of Co/C and W/C stacks to obtain a high reflection efficiency of the Ti characteristic lines while meeting the precise alignment requirement at the Cu Kα line.The alignment method based on dual simulated balls was proposed herein,which simultaneously realizes an accurate indication of the center field of view and the backlighter position.The optical design,multilayer coatings,and alignment method of the microscope and the experimental result of Ti flash radiography of the Au-coned CH shell target on the SG-Ⅱ Update are described. 展开更多
关键词 flash radiography Kirkpatrick-Baez microscope plasma diagnostics x-ray imaging x-ray multilayer
原文传递
基于压缩感知理论的高能闪光照相密度反演方法
17
作者 芦存博 盛云霄 《电子科技》 2023年第1期1-6,14,共7页
高能闪光照相中需要研究少数投影数据条件下的非轴对称客体的的密度反演问题。现有利用压缩感知思想的全变差TV类算法虽然考虑了图像的局部相似性,但没有考虑图像的非局部相似性。针对上述问题,文中提出了一种基于组稀疏正则化的全变分... 高能闪光照相中需要研究少数投影数据条件下的非轴对称客体的的密度反演问题。现有利用压缩感知思想的全变差TV类算法虽然考虑了图像的局部相似性,但没有考虑图像的非局部相似性。针对上述问题,文中提出了一种基于组稀疏正则化的全变分重建技术TV-GSR。该技术将组稀疏模型集成于TV框架之下,同时考虑了客体图像的局部相似性和非局部自相似性,充分利用了图像的先验稀疏信息,并利用客体的上、下、左、右4点对称性来降低图像重建的规模,重构精度有所增加,重建速度也更快。仿真实验表明,文中提出的TV-GSR算法提升了图像在无噪声和有噪声情况下的重建精度,对于高能闪光图像和纹理细节丰富的CT图像都有较好的效果,具有普适性。 展开更多
关键词 闪光照相 密度反演 图像重建 压缩感知 组稀疏正则化 全变差 稀疏信息 相似性
下载PDF
高能闪光X射线二极管设计与模拟 被引量:12
18
作者 梁川 谢敏 +2 位作者 章林文 马成刚 曹科峰 《强激光与粒子束》 EI CAS CSCD 北大核心 2008年第2期331-334,共4页
为了研制出便携式的具有较高性能的高能闪光X射线系统,需要发展新型紧凑型的高能闪光X射线二极管,要求其体积小,能工作在较高电压下。简要介绍了冷阴极X射线二极管的结构和工作原理;阐述了二极管绝缘结构设计原则,设计了一种新型的紧凑... 为了研制出便携式的具有较高性能的高能闪光X射线系统,需要发展新型紧凑型的高能闪光X射线二极管,要求其体积小,能工作在较高电压下。简要介绍了冷阴极X射线二极管的结构和工作原理;阐述了二极管绝缘结构设计原则,设计了一种新型的紧凑型轴向绝缘结构的X射线二极管;在高压端和地电极之间采用绝缘环和金属均压环交替叠加进行轴向绝缘,有利于减小二次电子发射几率,降低绝缘体表面爬电几率,缩短轴向绝缘距离。二极管工作电压为1 MV,轴向绝缘距离约260 mm,结合ANSYS数值模拟软件进行了静电场数值计算。二极管轴向绝缘区最大工作场强为95 kV/cm,各阳极三相点最大场强为26 kV/cm。计算结果表明:二极管的工作场强低于真空闪络场强;所有三相点的工作场强均满足绝缘要求。 展开更多
关键词 闪光照相 闪光X射线二极管 轴向绝缘结构 数值模拟
下载PDF
球形弹丸超高速正撞击薄板破碎状态实验研究 被引量:12
19
作者 迟润强 庞宝君 +3 位作者 何茂坚 管公顺 杨震琦 朱耀 《爆炸与冲击》 EI CAS CSCD 北大核心 2009年第3期231-236,共6页
利用闪光x射线照相系统拍摄了直径6.35mm的铝球以2.23~5.26km/s的速度正撞击薄铝板的过程并对该过程进行了分析,研究了弹丸从塑性变形到完全破碎的发展过程。给出了球形弹丸内部应力波传播的定性描述,提出弹丸形态变化包括3个阶... 利用闪光x射线照相系统拍摄了直径6.35mm的铝球以2.23~5.26km/s的速度正撞击薄铝板的过程并对该过程进行了分析,研究了弹丸从塑性变形到完全破碎的发展过程。给出了球形弹丸内部应力波传播的定性描述,提出弹丸形态变化包括3个阶段。在塑性变形阶段,弹丸变形随撞击速度和板厚的增大而增大;弹丸主体部分发生临界破碎时的撞击速度随薄板厚度增大而减小,当板厚超过一定值时,该速度基本相同,不受板厚影响;在完全破碎阶段,随撞击速度的增加,弹丸主体部分材料的径向速度增大,碎片尺寸减小,数量增多。 展开更多
关键词 爆炸力学 超高速撞击 闪光x射线照相 弹丸 空间碎片
下载PDF
便携式150kV闪光X光源研制及应用 被引量:7
20
作者 梁川 席璐璘 +3 位作者 周林 许泽平 李正宏 章林文 《强激光与粒子束》 EI CAS CSCD 北大核心 2014年第4期220-223,共4页
基于快前沿Mini-Marx发生器拓扑结构和冷阴极反射靶真空X射线二极管一体化设计研发出了紧凑型便携式150 kV闪光X光源系统.介绍了设计的Mini-Marx发生器和闪光X光二极管,给出了相应的实验结果.该闪光X光源系统获得了距光源25 cm处剂量大... 基于快前沿Mini-Marx发生器拓扑结构和冷阴极反射靶真空X射线二极管一体化设计研发出了紧凑型便携式150 kV闪光X光源系统.介绍了设计的Mini-Marx发生器和闪光X光二极管,给出了相应的实验结果.该闪光X光源系统获得了距光源25 cm处剂量大于7.7×10-6 C/kg、1 m处穿透铝大于60mm、焦斑1~3 mm可调的闪光X射线.该闪光X光源和成像单元组成的闪光照相具有系统体积小、运行可靠的特点. 展开更多
关键词 便携式闪光X光源 Mini-Marx发生器 闪光照相 X射线数字化成像
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部