Deep-sea sediment disturbance may occur when collecting polymetallic nodules,resulting in the creation of plumes that could have a negative impact on the ecological environment.This study aims to investigate the poten...Deep-sea sediment disturbance may occur when collecting polymetallic nodules,resulting in the creation of plumes that could have a negative impact on the ecological environment.This study aims to investigate the potential solution of using polyaluminum chloride(PAC)in the water jet.The effects of PAC are examined through a self-designed simulation system for deep-sea polymetallic nodule collection and sediment samples from a potential deep-sea mining area.The experimental results showed that the optimal PAC dose was found to be 0.75 g/L.Compared with the test conditions without the addition of PAC,the presence of PAC leads to a reduction in volume,lower characteristic turbidity,smaller diffusion velocity,and shorter settling time of the plume.This indicates that PAC inhibits the entire development process of the plume.The addition of PAC leads to the flocculation of mm-sized particles,resulting in the formation of cm-sized flocs.The flocculation of particles decreases the rate of erosion on the seabed by around 30%.This reduction in erosion helps to decrease the formation of plumes.Additionally,when the size of suspended particles increases,it reduces the scale at which they diffuse.Furthermore,the settling velocity of flocs(around 10^(-2) m/s)is much higher that of compared to sediment particles(around 10^(-5) m/s),which effectively reduces the amount of time the plume remains in suspension.展开更多
The electrokinetic characteristics and coagulation behaviors of polyaluminum silicate chloride (PASiC) and polyaluminum chloride (PAC) were studied and compared by streaming current (SC) measurement and jar test metho...The electrokinetic characteristics and coagulation behaviors of polyaluminum silicate chloride (PASiC) and polyaluminum chloride (PAC) were studied and compared by streaming current (SC) measurement and jar test method. The experimental results showed that the interaction between polysilicic acid characterized negative charge and hydrolyzed aluminum species result in a decrease of the charge neutralizing ability of PASiC, compared to PAC. The decrease has a close relationship with the basicity ( B ) and Al/Si molar ratio in PASiC. The less the B value and the Al/Si molar ratio, the lower the charge neutralizing ability of PASiC is. In contrast, the preparation technique for PASiC affects the charge-neutralization of PASiC to a smaller extent. In addition, compared with PAC, PASiC may enhance aggregating efficiency and give better coagulating effects.展开更多
Coagulation mechanisms of polyaluminum chloride(PACl) at various dosages were studied using a conventional jar test at different final and initial pH values during treating kaolin suspension. The optimal final pH and ...Coagulation mechanisms of polyaluminum chloride(PACl) at various dosages were studied using a conventional jar test at different final and initial pH values during treating kaolin suspension. The optimal final pH and dosages for PACl were obtained based on residual turbidity and zeta potential of flocs. The coagulation zones at various PACl dosages and solution p H values were developed and compared with those of alum. It is found that the optimal mechanism under acidic condition is charge neutralization, while alkaline condition will facilitate the coagulation of PACl. Both charge neutralization coagulation and sweep coagulation can achieve high coagulation efficiency under the alkaline condition ranging from final p H 7.0 to 10.0. Stabilization, charge neutralization destabilization, restabilization and sweep zones occur successively with increasing PACl dosages with the final p H values fixed at 7.0 and 8.0, but restabilization zone disappears at final p H 10.0. When the final p H is not controlled and consequently decreases with increasing PACl dosage, no typical sweep zone can be observed and the coagulant efficiency decreases at high PACl dosage. It seems that the final pH is more meaningful than the initial p H for coagulation. Charge neutralization coagulation efficiency is dominated by zeta potential of flocs and PACl precipitates. The charge neutralization and sweep coagulation zones of PACl are broader in the ranges of coagulant dosage and p H than those of alum. The results are helpful for us to treat water and wastewater using PACl and to understand the coagulation process of PACl.展开更多
Compared with traditional aluminum salts, polyaluminum chloride (PACI) has better coagulation-flocculation performance in turbidity removal. However, it is still inferior to organic polymers in terms of bridging fun...Compared with traditional aluminum salts, polyaluminum chloride (PACI) has better coagulation-flocculation performance in turbidity removal. However, it is still inferior to organic polymers in terms of bridging function. In order to improve the aggregating property of PACl, different composite PACl flocculants were prepared with various organic polymers. The effect of organic polymer on the distribution or Al(Ⅲ) species in composite flocculants was studied using ^27TAl NMR and Al-ferron complexation methods. The charge neutralization and surface adsorption characteristics of composite flocculants were also investigated. Jar tests were conducted to evaluate the turbidity removal efficacy of organic polymer modified composite flocculants. The study shows that cationic polymer and anionic polymer have significant influences on the coagulation-flocculation behaviors of PACl. Both cationic and anionic polymers can improve the turbidity removal performancc of PACl but the mechanisms arc much different: cationic organic polymer mainly increases the charge neutralization ability, but anionic polymer mainly enhances the bridging function.展开更多
A high flocculation performance composite flocculant was prepared with sodium alginate, polyaluminium ferric chloride and cationic polyacrylamide. And the composite flocculant was used in papermaking wastewater treatm...A high flocculation performance composite flocculant was prepared with sodium alginate, polyaluminium ferric chloride and cationic polyacrylamide. And the composite flocculant was used in papermaking wastewater treatment. Results indicated that it achieve the best flocculation performance when the raw material mass ratio was 2:1:1, the dosage of the composite flocculant was 20 mg/L, and the removal efficiency of COD and turbidity with this composite flocculant reached 89.6% and 99.2%, respectively.展开更多
基金supported by the National Natural Science Foundation of China(Nos.52225107,U2106224,U1906234,51822904,and U1706223)the Fundamental Research Funds for the Central Universities(No.202041004)
文摘Deep-sea sediment disturbance may occur when collecting polymetallic nodules,resulting in the creation of plumes that could have a negative impact on the ecological environment.This study aims to investigate the potential solution of using polyaluminum chloride(PAC)in the water jet.The effects of PAC are examined through a self-designed simulation system for deep-sea polymetallic nodule collection and sediment samples from a potential deep-sea mining area.The experimental results showed that the optimal PAC dose was found to be 0.75 g/L.Compared with the test conditions without the addition of PAC,the presence of PAC leads to a reduction in volume,lower characteristic turbidity,smaller diffusion velocity,and shorter settling time of the plume.This indicates that PAC inhibits the entire development process of the plume.The addition of PAC leads to the flocculation of mm-sized particles,resulting in the formation of cm-sized flocs.The flocculation of particles decreases the rate of erosion on the seabed by around 30%.This reduction in erosion helps to decrease the formation of plumes.Additionally,when the size of suspended particles increases,it reduces the scale at which they diffuse.Furthermore,the settling velocity of flocs(around 10^(-2) m/s)is much higher that of compared to sediment particles(around 10^(-5) m/s),which effectively reduces the amount of time the plume remains in suspension.
文摘The electrokinetic characteristics and coagulation behaviors of polyaluminum silicate chloride (PASiC) and polyaluminum chloride (PAC) were studied and compared by streaming current (SC) measurement and jar test method. The experimental results showed that the interaction between polysilicic acid characterized negative charge and hydrolyzed aluminum species result in a decrease of the charge neutralizing ability of PASiC, compared to PAC. The decrease has a close relationship with the basicity ( B ) and Al/Si molar ratio in PASiC. The less the B value and the Al/Si molar ratio, the lower the charge neutralizing ability of PASiC is. In contrast, the preparation technique for PASiC affects the charge-neutralization of PASiC to a smaller extent. In addition, compared with PAC, PASiC may enhance aggregating efficiency and give better coagulating effects.
基金Supported by the Special Funds of Technological Development for Scientific Research Institutes from the Ministry of Science and Technology of China(2010EG111022,2011EG111307,2012EG111122)the Program for Overseas Talents(OTP-2013-015)the Program for Innovative Research Team(IG201204N)from Beijing Academy of Science and Technology
文摘Coagulation mechanisms of polyaluminum chloride(PACl) at various dosages were studied using a conventional jar test at different final and initial pH values during treating kaolin suspension. The optimal final pH and dosages for PACl were obtained based on residual turbidity and zeta potential of flocs. The coagulation zones at various PACl dosages and solution p H values were developed and compared with those of alum. It is found that the optimal mechanism under acidic condition is charge neutralization, while alkaline condition will facilitate the coagulation of PACl. Both charge neutralization coagulation and sweep coagulation can achieve high coagulation efficiency under the alkaline condition ranging from final p H 7.0 to 10.0. Stabilization, charge neutralization destabilization, restabilization and sweep zones occur successively with increasing PACl dosages with the final p H values fixed at 7.0 and 8.0, but restabilization zone disappears at final p H 10.0. When the final p H is not controlled and consequently decreases with increasing PACl dosage, no typical sweep zone can be observed and the coagulant efficiency decreases at high PACl dosage. It seems that the final pH is more meaningful than the initial p H for coagulation. Charge neutralization coagulation efficiency is dominated by zeta potential of flocs and PACl precipitates. The charge neutralization and sweep coagulation zones of PACl are broader in the ranges of coagulant dosage and p H than those of alum. The results are helpful for us to treat water and wastewater using PACl and to understand the coagulation process of PACl.
文摘Compared with traditional aluminum salts, polyaluminum chloride (PACI) has better coagulation-flocculation performance in turbidity removal. However, it is still inferior to organic polymers in terms of bridging function. In order to improve the aggregating property of PACl, different composite PACl flocculants were prepared with various organic polymers. The effect of organic polymer on the distribution or Al(Ⅲ) species in composite flocculants was studied using ^27TAl NMR and Al-ferron complexation methods. The charge neutralization and surface adsorption characteristics of composite flocculants were also investigated. Jar tests were conducted to evaluate the turbidity removal efficacy of organic polymer modified composite flocculants. The study shows that cationic polymer and anionic polymer have significant influences on the coagulation-flocculation behaviors of PACl. Both cationic and anionic polymers can improve the turbidity removal performancc of PACl but the mechanisms arc much different: cationic organic polymer mainly increases the charge neutralization ability, but anionic polymer mainly enhances the bridging function.
文摘A high flocculation performance composite flocculant was prepared with sodium alginate, polyaluminium ferric chloride and cationic polyacrylamide. And the composite flocculant was used in papermaking wastewater treatment. Results indicated that it achieve the best flocculation performance when the raw material mass ratio was 2:1:1, the dosage of the composite flocculant was 20 mg/L, and the removal efficiency of COD and turbidity with this composite flocculant reached 89.6% and 99.2%, respectively.