期刊文献+
共找到66篇文章
< 1 2 4 >
每页显示 20 50 100
Flow injection chemiluminescence determination of meloxicam using potassium permanganate and formaldehyde system 被引量:1
1
作者 贾宝秀 曹明亮 +3 位作者 刘彩红 李玉琴 李珂 齐永秀 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第1期35-40,共6页
A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium pe... A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h. 展开更多
关键词 MELOXICAM flow injection chemiluminescence FORMALDEHYDE Pharmaceutical analysis
下载PDF
Flow injection spectrophotometric determination of vitamin E in pharmaceuticals,milk powder and blood serum using potassium ferricyanide-Fe(Ⅲ) detection system 被引量:3
2
作者 Saima Jadoon Amir Waseem +1 位作者 Mohammad Yaqoob Abdul Nabi 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第6期712-715,共4页
A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide redu... A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide reduces.The in situ reduced ions are then reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to make soluble Prussian blue,which is monitored at absorption wavelength of 735 nm.Linear calibration graph was obtained in the concentration range of 0.1-40μg mL^(-1).The relative standard deviations (n=4) were in the range of 1.1-3.6%,with limits of detection(3 s blank) of 0.04μg mL^(-1).The proposed method allowed 12 injections h^(-1).The method is applied to determine vitamin E in pharmaceuticals,infant milk and blood serum samples using hexane extraction with the recoveries in the range of 93±3 to 97.5±4%.The method is validated using certified reference materials SRM 968c for blood serum samples. 展开更多
关键词 flow injection SPECTROPHOTOMETRY Vitamin E Prussian blue FE(III) FERRICYANIDE Pharmaceuticals Blood serum
下载PDF
Determination of Gossypol in Trace Level by Flow Injection Analysis with Chemiluminescence Detection 被引量:3
3
作者 Bing Chun XUE Er Bao LIU 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第1期57-60,共4页
This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitiz... This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results. 展开更多
关键词 Single-molecule detection CHEMILUMINESCENCE flow injection gossypol.
下载PDF
Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3
4
作者 Li Jun Li Qi Feng Chen +5 位作者 Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong Jian Ling Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页
A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum elec... A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. 展开更多
关键词 flow injection Irreversible biamperometry Chlorogenic acid HONEYSUCKLE
下载PDF
Determination of Ciprofloxacin by Flow Injection Analysis Based on Chemiluminescence System 被引量:1
5
作者 张卓勇 李夏 +3 位作者 王小丽 陈世稆 宋保华 赵慧春 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期285-288,共4页
A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence... A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00 × 10^-8 - 9.00 × 10^-7 mol ·L-1 and the detection limit for CPLX is 4.40 × 10^-9 mol·L^-1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110 ± 4 to 104 ± 4. 展开更多
关键词 CIPROFLOXACIN CHEMILUMINESCENCE TERBIUM flow injection KMNO4 Na2S2O4 rare earths
下载PDF
A Novel Flow Injection Optical Fiber Biosensor for Hypoxanthine Based on Luminol Electrochemiluminescence 被引量:1
6
作者 LI Ying xiu ZHU Lian de ZHU Guo yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第2期240-244,共5页
关键词 ELECTROCHEMILUMINESCENCE flow injection Optical fiber biosensor Sol-gel Ceramic-carbon composite electrode HYPOXANTHINE Fish freshness
下载PDF
Study on Chemiluminescence Reactions of L ucigenin and Reductants by Flow Injection Analysis 被引量:1
7
作者 Zhi Jia ZHU Jiu Ru LU (Experimental Center, Hebei Normal University. Shijiazhuang 050016 Department of Chemistry, Shaanxi Normal University, Xian 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第1期61-64,共4页
The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) ... The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) and Fe(III) through a micro Jones column, are studied in detail. Results show that the reactions can be used directly for the determination of these substances. The mechanism of the reactions is also investigated. 展开更多
关键词 reductant LUCIGENIN CHEMILUMINESCENCE flow injection analysis
下载PDF
On-line Preconcentration and Determination of Trace Metals in Water Samples by Flow Injection Combined with Flame Atomic Absorption Spectrometry via Calix[4]arene Carboxylic Acid Packed Micro-column 被引量:1
8
作者 GUO Da-wang, ZHAO Xiao-wei, JIA Qiong and ZHOU Wei-hong College of Chemistry, Jilin University, Changchun 130012, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第1期26-30,共5页
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determinatio... An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples. 展开更多
关键词 arene carboxylic acid PRECONCENTRATION flow injection Metal ion Flame atomic absorptionspectrometry(FAAS)
下载PDF
Flow Injection Chemiluminescence Analysis of Low Level Concentration of Hydrazine 被引量:1
9
作者 Zheng Hua SONG Lin WANG +1 位作者 Ji Hong Lü Tie Zhu ZHAO 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第9期799-802,共4页
Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal pro... Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal produced by the reaction between luminol and hexacyanoferrate (III) in alkaline medium. The decreased CL intensity was linear with hydrazine concentration in the range of 5.0×10-9 g·mL-1 to 4.0×10-5 g·mL-1, and the limit of detection was 2.0×10-9 g·mL-1 (3σ) with a relative standard deviation of 2.4~4.1% (n=5). 展开更多
关键词 HYDRAZINE flow injection CHEMILUMINESCENCE
下载PDF
Numerical Study on the Effects of Contraction Ratio in a Two-Phase Flow Injection Nozzle 被引量:1
10
作者 Haider Ali Kyung Won Kim +2 位作者 Jae Sik Kim Jong Yun Choi Cheol Woo Park 《Open Journal of Fluid Dynamics》 2016年第1期1-10,共10页
The Euler-Euler numerical method was used to investigate the effects of contraction ratio on twophase flow mixing with mass transfer in the flow injection nozzle. The geometric shape of the nozzle was modified to impr... The Euler-Euler numerical method was used to investigate the effects of contraction ratio on twophase flow mixing with mass transfer in the flow injection nozzle. The geometric shape of the nozzle was modified to improve carbonation efficiency. A gas inlet hole was created to increase the flow mixing of CO2 with water. A nozzle throat was also introduced to increase the gas dissolution by increasing flow rates. Various contraction ratios of nozzle throat, inlet gas and liquid velocities, and gas bubble sizes were employed to determine their effects on gas hold-up, gas concentration, and mass transfer coefficient. Results revealed that the flow injection nozzle with high contraction ratios improved carbonation because of high gas hold-up. Gas concentration was directly related to contraction ratio and gas flow velocities. Carbonation reduced when high liquid velocities and large gas bubbles were employed because of inefficient flow mixing. This study indicated that flow injection nozzle with large contraction ratios were suitable for carbonation because of their ability to increase gas hold-up, gas concentration, and mass transfer coefficient. 展开更多
关键词 flow injection Nozzle Nozzle Throat Contraction Ratio Gas-Liquid flow Mass Transfer
下载PDF
Kinetic-spectrophotometric determination of free cyanide by stopped-flow reversed flow injection analysis
11
《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第3期367-372,共6页
A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The ... A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The flow is stopped when the reagent zone comes in the flow cell, where absorbance-time data are collected at 580nm wavelength. The linear range of the determination is 0.1 -10μg/ml CN-. The sampling rate is 60h-1 and the relative standard deviation is 1.6% (n=16) at 5.0 μg/ml CN-1 level. With satisfactory results, the proposed method was applied to the determination of free cyanide in wastewater without sample pretreatment. 展开更多
关键词 kinetic analysis STOPPED-flow reversed flow injection system free cyanide wastewater.
下载PDF
Study on Quenching Effect of Holmium (Ⅲ) Ion in Chemiluminescence System of Luminol H_2O_2-Cr(Ⅲ) by Flow Injection Technique
12
作者 朱智甲 《Rare Metals》 SCIE EI CAS CSCD 2000年第1期39-41,共3页
A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detecti... A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detection limit is 3×10 -8 mol/L, the linear range is from 1×10 -7 to 1×10 -4 mol/L; the relative standard deviation is less than 3% (for 2×10 -7 mol/L Ho, n=11). The method was applied to determination of Ho(Ⅲ) in pure samples with satisfactory results. 展开更多
关键词 HOLMIUM flow injection Chemiluminescence analysis LUMINOL
下载PDF
O-(β-hydroxyethyl)rutosides determination by micellar flow injection(FI)-spectrofluorimetry
13
作者 Cecilia Mariana Peralta Liliana Patricia Fernndez 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第6期368-373,共6页
A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant ... A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement,increasing considerably the sensitivity of detection.All the variables affecting the fluorescence intensity were studied and optimized.The flow rate was 5 mL/min with detection at 450 nm(after excitation at 346 nm).A linear correlation between drug amount and peak area was established for 0-(β-hydroxyethyl)rulosides in the range of 0.01-200 μg/mL with a detection limit of0.001 μg/mL(s/n = 3).Validation processes were performed by recovering studies with satisfactory results.The new methodology can be employed for the routine analysis of 0-(P-hydroxyethyl)rutosides in bulks as well as in commercial formulations. 展开更多
关键词 O-(β-hydroxyethyl)rutosides Micellar enhancement flow injection SPECTROFLUORIMETRY Pharmaceuticals
下载PDF
Flow Injection Analysis of Histidine with Enhanced Electrogenerated Chemiluminescence of Luminol
14
作者 LianDeZHU YingXiuLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第11期1093-1096,共4页
A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental para... A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation. 展开更多
关键词 Electrogenerated chemiluminescence flow injection analysis LUMINOL histidine.
下载PDF
Studies on Combination of Flow Injection and Microwave Plasma Torch-Atomic Emission Spectrometry
15
作者 YE Dong-mei, ZHAO Jing-hong, ZHANG Han-qi and JIN Qin-han (Department of Chemistry, Jilin University, Changchun, 130023)DONG De-fan (Hebei College of Geology, Shijiazhuang, 050031) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期246-247,共2页
Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma syst... Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP 展开更多
关键词 Microwave plasma torch flow injection Atomic emission spectrometry
下载PDF
Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine
16
作者 SHUAI Qin QIN Yong-chao +2 位作者 JIANG Zu-cheng LI Feng LIAO Zhen-huan (College of Chemistry and Environmental Science, Wuhan University, Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期83-88,共6页
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine... A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk. 展开更多
关键词 high performance liquid chromatography(HPLC) flow injection analysis (FIA) ECDYSTERONE traditional Chinese medicine
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
17
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 flow SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION flow injection ANALYSIS WITH CHEMILUMINESCENT DETECTION GAS
下载PDF
Normal and reverse flow injection-spectrophotometric determination of thiamine hydrochloride in pharmaceutical preparations using diazotized metoclopramide
18
作者 Mouayed Q.Al Abachi Hind Hadi 《Journal of Pharmaceutical Analysis》 CAS 2012年第5期350-355,共6页
Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the r... Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the reaction between THC and diazotized metoclopramide in alkaline medium. Beer's law was obeyed over the range of 10 300 and 2-90 ug/mL, the limits of detection were 2.118 and 0.839 ug/mL and the sampling rates were 80 and 95 injections per hour for normal and reverse flow injection methods respectively. The application of both methods to commercially available pharmaceuticals produced acceptable results. The flow system is suitable for application in quality control processes. 展开更多
关键词 THIAMINE METOCLOPRAMIDE flow injection SPECTROPHOTOMETRY
下载PDF
Determination of ribavirin by flow injection chemiluminescence
19
作者 Juqing Jin Yuhai Tang +2 位作者 Langchong He Hong Yao Yuanyuan Sun 《Journal of Nanjing Medical University》 2006年第5期266-270,共5页
Objective: To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide... Objective: To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide (NaOH) solution with potassium chlorate (KClO3). The different experimental parameters affecting the CL intensity were studied carefully. Results: Under optimum conditions (The concentrations of luminol, KClO3, and NaOH were at 0.1 mmol/L, 0.5μmol/L, and 0.2 mol/L, respectively), the linear range of the working curves was 0.01-7.00μg/ml with a detection limit of 0.004μg/ml. Conclusion: The method is simple, rapid and sensitive, and successfully applied to the determination of ribavirin in pharmaceutical preparations and biological fluids. 展开更多
关键词 flow injection analysis CHEMILUMINESCENCE RIBAVIRIN
下载PDF
Flow Injection Chemiluminescence Determination of 4-methylsalicylic
20
作者 董彦杰 《陇东学院学报》 2012年第5期28-31,共4页
As potassium bichromate can be reduced by 4-methysalicylic acid to chromium(III) which enhance the CL intensity of luminol-H2O2 system,a new chemiluminescence system for the determination of 4-methysalicylic acid has ... As potassium bichromate can be reduced by 4-methysalicylic acid to chromium(III) which enhance the CL intensity of luminol-H2O2 system,a new chemiluminescence system for the determination of 4-methysalicylic acid has been established.The relative CL intensity was correlated with salicylic acid concentration in the range 7.0×10-9~8.0×10-6 mol/L,and the detection limit was 1.0×10-9 mol/L.The relative standard deviation(n=8) for 4.0×10-7 mol/L 4-methysalicylic acid is 2.9%.The method has been applied to the determination of 4-methysalicylic acid in the bactericidal solutions with satisfactory results. 展开更多
关键词 flow injection CHEMILUMINESCENCE LUMINOL Hydrogen peroxide 4-Methysalicylic acid
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部