The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat tr...The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat transfer characteristics,which restricts the promotion and application of the technology.To this end,the water-cooling plate of a heat dissipation system was taken as the research object,and its flow and heat transfer characteristics were numerical simulated and experimental studied.Through comparative analysis,the rationality of the numerical simulation method was verified.Based on this,three improved schemes of water-cooling plate structure were proposed and numerical simulation was carried out,and the optimal model was verified by experiments.The results of the study show that compared with the original water-cooling plate,the optimized water-cooling plate has increased internal flow velocity and distributes uniformly,increased heat transfer amount by 4.2%,and the average temperature of the calculation plate decreased by 5.3%.展开更多
Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorat...Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device.展开更多
文摘The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat transfer characteristics,which restricts the promotion and application of the technology.To this end,the water-cooling plate of a heat dissipation system was taken as the research object,and its flow and heat transfer characteristics were numerical simulated and experimental studied.Through comparative analysis,the rationality of the numerical simulation method was verified.Based on this,three improved schemes of water-cooling plate structure were proposed and numerical simulation was carried out,and the optimal model was verified by experiments.The results of the study show that compared with the original water-cooling plate,the optimized water-cooling plate has increased internal flow velocity and distributes uniformly,increased heat transfer amount by 4.2%,and the average temperature of the calculation plate decreased by 5.3%.
基金supported by the National Basic Research Program of China (973 Program)(Grant No.2009CB219804)the National Scientific and Technical Supporting Program of China(Grant No.2011BAA04B02)
文摘Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device.