期刊文献+
共找到1,925篇文章
< 1 2 97 >
每页显示 20 50 100
Study on Chemiluminescence Reactions of L ucigenin and Reductants by Flow Injection Analysis 被引量:1
1
作者 Zhi Jia ZHU Jiu Ru LU (Experimental Center, Hebei Normal University. Shijiazhuang 050016 Department of Chemistry, Shaanxi Normal University, Xian 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第1期61-64,共4页
The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) ... The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) and Fe(III) through a micro Jones column, are studied in detail. Results show that the reactions can be used directly for the determination of these substances. The mechanism of the reactions is also investigated. 展开更多
关键词 reductant LUCIGENIN CHEMILUMINESCENCE flow injection analysis
下载PDF
AN APPLICATION OF TOPOLOGICAL ANALYSIS TO STUDYING THE THREE-DIMENSIONAL FLOW IN CASCADES;PART I—TOPOLOGICAL RULES FOR SKIN-FRICTION LINES AND SECTION STREAMLINES 被引量:2
2
作者 康顺 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1990年第5期489-495,共7页
Based on the working of Lighthill and Hunt et al., in the present paper the author has established the topological rules adapting to analysing the skin-friction lines and the section streamlines in cascades. These rul... Based on the working of Lighthill and Hunt et al., in the present paper the author has established the topological rules adapting to analysing the skin-friction lines and the section streamlines in cascades. These rules are (1) for a rotor cascade without shroud band, the total number of nodal points equals that the saddle points on the skin-friction line vector fields in eachpitch range; (2) for an annular or straight cascade with no-clearances at blade ends, the total number of saddle points is two more than that of nodal points on the skin-friction line fields in a pitch; (3) the total number of saddles in the secondary flow fields on cross-sections in cascade is one less than that of nodes; (4) in the section streamline vector fields on a meridian surface penetrating a flow passage, and on leading and trailing edge sections, the total number of nodes is equal to that of saddles; (5) on the streamline vector fields of a blade-to-blade surface, the total number of nodes is one less than that of saddles. 展开更多
关键词 node TOPOLOGICAL RULES FOR SKIN-FRICTIon lineS AND SECTIon STREAMlineS AN APPLICATIon of TOPOLOGICAL analysis TO STUDYING THE THREE-DIMENSIonAL flow IN CASCADES PART I
下载PDF
Chemiluminescence Determination of Molybdenum by on-Line Reduction with a Flow Injection System 被引量:4
3
作者 Zhi Jia ZHU (Experimental Center, Hebei Normal University, Shijiazhuang 050016) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第5期427-430,共4页
The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination o... The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples. 展开更多
关键词 chemiluminescence analysis reductant flow-injection MOLYBDENUM LUCIGENIN
下载PDF
Flow-Injection Microcolumn on-Line Preconcentration for theDetermination of Chromium(Ⅵ) 被引量:1
4
作者 Ma Wanhong Cat Ruxiu Lin Zhixin(College of Chemistry, Wuhan University. Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 1998年第4期464-468,共5页
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a... A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5). 展开更多
关键词 anometer-size TiO2 Cr (Ⅵ) determination on-line preconcentration flow-injection spectrophotometric detection
下载PDF
Kinetic-spectrophotometric determination of free cyanide by stopped-flow reversed flow injection analysis
5
《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第3期367-372,共6页
A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The ... A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The flow is stopped when the reagent zone comes in the flow cell, where absorbance-time data are collected at 580nm wavelength. The linear range of the determination is 0.1 -10μg/ml CN-. The sampling rate is 60h-1 and the relative standard deviation is 1.6% (n=16) at 5.0 μg/ml CN-1 level. With satisfactory results, the proposed method was applied to the determination of free cyanide in wastewater without sample pretreatment. 展开更多
关键词 kinetic analysis STOPPED-flow reversed flow injection system free cyanide wastewater.
下载PDF
Flow Injection Analysis of Histidine with Enhanced Electrogenerated Chemiluminescence of Luminol
6
作者 LianDeZHU YingXiuLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第11期1093-1096,共4页
A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental para... A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation. 展开更多
关键词 Electrogenerated chemiluminescence flow injection analysis LUMINOL histidine.
下载PDF
An analysis method of injection and production dynamic transient flow in a gas field storage facility
7
作者 WANG Jieming LI Chun +4 位作者 SUN Junchang TANG Ligen ZHONG Rong LIU Xianshan ZHENG Shaojing 《Petroleum Exploration and Development》 CSCD 2022年第1期179-190,共12页
A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing metho... A dynamic transient flow analysis method considering complex factors such as the cyclic injection and production history in a gas field storage facility was established in view of the limitations of the existing methods for transient flow analysis and the characteristics of the injection-production operation of strongly heterogeneous gas reservoirs, and the corresponding theoretical charts were drawn. In addition, an injection-production dynamic transient flow analysis model named "three points and two stages" suitable for an underground gas storage(UGS) well with alternate working conditions was proposed. The "three points" refer to three time points during cyclic injection and production, namely, the starting point of gas injection for UGS construction, the beginning and ending points of the injection-production analysis stage;and the "two stages" refer to historical flow stage and injection-production analysis stage. The study shows that the dimensionless pseudo-pressure and dimensionless pseudo-pressure integral curves of UGS well flex downward in the early stage of the injection and production process, and the dimensionless pseudo-pressure integral derivative curve is convex during the gas production period and concave during the gas injection period, and the curves under different flow histories have atypical features. The new method present in this paper can analyze transient flow of UGS accurately. The application of this method to typical wells in Hutubi gas storage shows that the new method can fit the pressure history accurately, and obtain reliable parameters and results. 展开更多
关键词 gas field storage facility injection and production performance alternate working conditions transient flow analysis theoretical chart
下载PDF
Flow Injection Analysis of Hydrazine in the Aqueous Streams of Purex Process by Liquid Chromatography System Coupled with UV-Visible Detector
8
作者 P. Velavendan S. Ganesh, N. K. Pandey +2 位作者 N. K. Pandey U. Kamachi Mudali R. Natarajan 《Journal of Analytical Sciences, Methods and Instrumentation》 2012年第3期156-160,共5页
Present study describes the development of a rapid, sensitive and selective flow injection analysis of hydrazine in the aqueous streams of purex process by liquid chromatography system coupled with UV-Visible detector... Present study describes the development of a rapid, sensitive and selective flow injection analysis of hydrazine in the aqueous streams of purex process by liquid chromatography system coupled with UV-Visible detector. The method is based on the formation of yellow coloured azine complex by reaction of hydrazine with para-dimethy laminobenzaldehyde (pDMAB). The formed yellow coloured complex is stable in acidic medium and has a maximum absorption at 460 nm. The presence of uranium in hydrazine solution is not interfering in the analysis. Under optimum condition, the absorption intensity linearly increased with the concentration of hydrazine in the range from 0.05-10 mg?L–1 with a correlation coefficient of R2=0.9999 (n=7). The experimental detection limit is 0.05mgL–1. The sampling frequency is 15 samples h–1 and the relative standard deviation was 2.1% for 0.05 mg?L–1. This method is suitable for automatic and continuous analysis and successfully applied to determine the concentration of hydrazine in the aqueous stream of nuclear fuel reprocessing. 展开更多
关键词 HYDRAZINE Liquid Chromatography PUREX Process flow injection analysis Para-Dimethylaminobenaldehyde UV-VIS DETECTOR
下载PDF
Simultaneous Biparametric Determination of Total Calcium and Potassium in Biological Fluids by Flow Injection Analysis──Use of Powell's Method in the System Optimization
9
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第1期5-15,共11页
SimultaneousBiparametricDeterminationofTotalCalciumandPotassiuminBiologicalFluidsbyFlowInjectionAnalysis──Us... SimultaneousBiparametricDeterminationofTotalCalciumandPotassiuminBiologicalFluidsbyFlowInjectionAnalysis──UseofPowell'sMethod... 展开更多
关键词 flow-injection analysis Two-component determination Potassiumand calcium Blood serum Powell's optimization
下载PDF
Flow Injection Analysis Technique for Online Preconcentration of Lead Ions in Airborne Particulate Matter Using Imprinted Polymer as the Sorbent
10
作者 Muhammad Bachri Amran Novita Ambarsari +3 位作者 Muhammad Ali Zulfikar Asri Indrawati Rusnadi Rusnadi Saipul Hamdi 《Journal of Analysis and Testing》 EI CSCD 2024年第2期180-190,共11页
This work reported a simple and sensitive flow injection analysis(FIA)technique coupled with a Flame Atomic Absorption Spectrophotometer(FAAS)for online preconcentration of lead(Ⅱ)ions in the airborne particulate mat... This work reported a simple and sensitive flow injection analysis(FIA)technique coupled with a Flame Atomic Absorption Spectrophotometer(FAAS)for online preconcentration of lead(Ⅱ)ions in the airborne particulate matter samples(PM_(2.5))using ion-imprinted polymers as adsorbent packed in minicolumn.A bulk polymerization method was chosen to synthesize the polymer based on a ternary complex of lead ions with 4-2-pyridilazo resorcinol and 4-vinyl pyridine with methacrylic acid as a functional monomer.The optimum pH for sorption was 6,and other variables for the FIA system were optimized,including breakthrough volume,eluent concentration,and eluent volume.The optimum conditions were reached with a breakthrough volume of 4.45 mL,calculated as a dynamic retention capacity of 5.20 mg/g of Pb(II)40 mg/L,with a 1.5 mL/min flow rate.The eluent used for the FIA system was 0.5 mL HNO_(3)of 3 mol/L.Linearity,precision,and limits of detection of the FIA system were determined before being applied to preconcentration and analysis of lead ions in PM_(2.5)samples.The precision of the method was determined to be 3.09%by calculating the coefficients of the variant.Linearity of the method in the concentration range of 50-1000μg/L gave a coefficient correlation of 0.9925,showing a good response,and the limit of detection of the system was 5.11μg/L,better than that of the FAAS method.Performances of the FIA system were evaluated and showed good results with an enrichment factor of more than 20 times higher and a concentration efficiency of 11.65 min^(-1)with a consumptive index of 4.5 mL.Preconcentration and analysis of the PM_(2.5)samples in Bandung City showed the concentrations of Pb(II)were 26.67μg/L and 33.3μg/L with the accuracy of the method for each sample of104.75%and 107.86%. 展开更多
关键词 flow injection analysis Lead(II)ions Imprinted polymer Particulate matter
原文传递
Flow-injection Spectrophotometric Determination of Uric Acid in Urine via Prussian Blue Reaction 被引量:1
11
作者 WASEEM Amir YAQOOB Mohammad +2 位作者 NABI Abdul MURTAZA Ghulam HUSSAIN Izhar 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期929-933,共5页
A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ... A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly. 展开更多
关键词 flow injection analysis SPECTROPHOTOMETRY Uric acid Prussian blue URINE
下载PDF
Study on Quenching Effect of Holmium (Ⅲ) Ion in Chemiluminescence System of Luminol H_2O_2-Cr(Ⅲ) by Flow Injection Technique
12
作者 朱智甲 《Rare Metals》 SCIE EI CAS CSCD 2000年第1期39-41,共3页
A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detecti... A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detection limit is 3×10 -8 mol/L, the linear range is from 1×10 -7 to 1×10 -4 mol/L; the relative standard deviation is less than 3% (for 2×10 -7 mol/L Ho, n=11). The method was applied to determination of Ho(Ⅲ) in pure samples with satisfactory results. 展开更多
关键词 HOLMIUM flow injection Chemiluminescence analysis LUMINOL
下载PDF
Flow-injection spectrophotometric determination of vanadium with malachite green oxalate by bromate in acidic and micellar medium
13
作者 Mohsen Keyvanfarda Narges Abedib 《Rare Metals》 SCIE EI CAS CSCD 2011年第3期216-221,共6页
A flow injection method is proposed for determining vanadium(V). The method is based on its catalytic effect on the oxidation of malachite green oxalate by bromate. The reaction was monitored spectrophotometrically ... A flow injection method is proposed for determining vanadium(V). The method is based on its catalytic effect on the oxidation of malachite green oxalate by bromate. The reaction was monitored spectrophotometrically by measuring malachite green oxalate absorbance at λmax = 625 nm. The reagents and manifold variables, which have influences on the sensitivity, were investigated and the optimum conditions were established. The optimized conditions made it possible to determine vanadium in the ranges of 10-140 ng/mL with a detection limit of 5.2 ng/mL and a sample rate of 20 ± 5 samples/h. 展开更多
关键词 VANADIUM flow injection analysis malachite green oxalate SPECTROPHOTOMETRY micellar medium
下载PDF
Determination of Lanthanu m in Lu minol- H_2 O_2- Cr( Ⅲ) Syste m by Flow Injection Chemilu minescence
14
作者 朱智 周清 《Rare Metals》 SCIE EI CAS CSCD 1999年第3期225-228,共4页
A novel method of flow injection chemiluminescence (CL) analysis for the determination of rare earth La(Ⅲ) ion is prensented. It is based on the quenching effect of La(Ⅲ) ion in the CL system of Luminol H 2O 2 ... A novel method of flow injection chemiluminescence (CL) analysis for the determination of rare earth La(Ⅲ) ion is prensented. It is based on the quenching effect of La(Ⅲ) ion in the CL system of Luminol H 2O 2 Cr(Ⅲ). The CL emission intensity is linear with La(Ⅲ) concentration in the range 1×10 -7 ~1×10 -4 mol/L; the detection limit is 4×10 -8 mol/L, the relative standard deviation is less than 3% (for 2×10 -7 mol/L La, n =11). 展开更多
关键词 Rare earth La(Ⅲ) flow injection Chemiluminescence analysis LUMINOL
下载PDF
Flow Injection Determination of Tramadol Based on Its Sensitizing Effect on the Chemiluminescent Reaction of Permanganate-Sulfite 被引量:1
15
作者 Xun Yao Jingkai Zhang Jianguo Li 《American Journal of Analytical Chemistry》 2011年第7期768-775,共8页
In this paper, a novel chemiluminescence (CL) method for the determination of tramadol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite an... In this paper, a novel chemiluminescence (CL) method for the determination of tramadol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite and acidic KMnO4. A mechanism for the CL reaction has been proposed on the basis of fluorescent and CL spectra. Under the optimized conditions, the proposed method allows the measurement of tramadol hydrochloride over the range of 0.04 - 4 ?g/mLwith a correlation coefficient of 0.9995 (n = 8) and a detection limit of 0.01 ?g/mL (3σ), and the relative standard deviation for 2.0 ?g/mL tramadol (n = 11) is 2.1%. The utility of this method was demonstrated by determining tramadol hydrochloride in tablets and injections. 展开更多
关键词 Chemiluminescence TRAMADOL HYDROCHLORIDE KMNO4 Sodium SULFITE flow-injection analysis
下载PDF
Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine
16
作者 SHUAI Qin QIN Yong-chao +2 位作者 JIANG Zu-cheng LI Feng LIAO Zhen-huan (College of Chemistry and Environmental Science, Wuhan University, Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期83-88,共6页
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine... A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk. 展开更多
关键词 high performance liquid chromatography(HPLC) flow injection analysis (FIA) ECDYSTERonE traditional Chinese medicine
下载PDF
Determination of ribavirin by flow injection chemiluminescence
17
作者 Juqing Jin Yuhai Tang +2 位作者 Langchong He Hong Yao Yuanyuan Sun 《Journal of Nanjing Medical University》 2006年第5期266-270,共5页
Objective: To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide... Objective: To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide (NaOH) solution with potassium chlorate (KClO3). The different experimental parameters affecting the CL intensity were studied carefully. Results: Under optimum conditions (The concentrations of luminol, KClO3, and NaOH were at 0.1 mmol/L, 0.5μmol/L, and 0.2 mol/L, respectively), the linear range of the working curves was 0.01-7.00μg/ml with a detection limit of 0.004μg/ml. Conclusion: The method is simple, rapid and sensitive, and successfully applied to the determination of ribavirin in pharmaceutical preparations and biological fluids. 展开更多
关键词 flow injection analysis CHEMILUMINESCENCE RIBAVIRIN
下载PDF
Flow Injection Amperometric Determination of Phenol and Chlorophenols at Single Wall Carbon Nanotube Modified Glassy Carbon Electrode
18
作者 Negussie Negash Hailemichael Alemu Merid Tessema 《American Journal of Analytical Chemistry》 2014年第3期188-198,共11页
Single wall carbon nanotube modified glassy carbon electrode (SWCNT/GCE) was used for flow-injection analysis (FIA) for phenolic compounds (phenol (P), 4-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorphen... Single wall carbon nanotube modified glassy carbon electrode (SWCNT/GCE) was used for flow-injection analysis (FIA) for phenolic compounds (phenol (P), 4-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorphenol (TCP) and pentachlorophenol (PCP)). Experimental variables such as the detection potential, flow rate and pH of the carrier solution, 0.1 M sodium acetate, were optimized. Under these conditions, the designed electrode showed a very good performance for the amperometric measurements, with no need to apply a cleaning or pre-treatment procedure. The operational stability was tested with 20 repetitive injections of each analyte and was found to be good. The analytical performance of the SWCNT/GCE electrode under flow through conditions was tested and was found to be impressive. When it is compared with other enzymatic and non-enzymatic sensors, it shows wider dynamic range for the detection of phenolic compounds with low limits of detection. These results suggest that the method is quite useful for monitoring and analyzing phenols and chlorophenols. 展开更多
关键词 Single WALL Carbon NANOTUBE Modified ELECTRODE PHENOL and CHLOROPHENOLS AMPEROMETRY flow injection analysis
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
19
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 flow SELECTIVE SULFUR DIOXIDE DETERMINATIon BY GAS DIFFUSIon flow injection analysis WITH CHEMILUMINESCENT DETECTIon GAS
下载PDF
Electrogeneration of ferrate (Ⅵ) in low concentration NaOH solution for flow-injection-chemiluminescence detection
20
作者 Hui Jing Zhang Yong Gang Hu +1 位作者 Yong Qian Wang Jie Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第8期951-954,共4页
The possibility of direct analytical applications of ferrate(Ⅵ) solution,which was freshly electrogenerated in low-concentration NaOH electrolyte,was studied by a flow-injection-chemiluminescence(FI-CL) system.It... The possibility of direct analytical applications of ferrate(Ⅵ) solution,which was freshly electrogenerated in low-concentration NaOH electrolyte,was studied by a flow-injection-chemiluminescence(FI-CL) system.It was found that some inorganic ions, organic molecule and biomolecule could enhance the chemiluminescence emission caused by ferrate(Ⅵ)-luminol reaction.V(Ⅴ), Ca(Ⅱ),Mg(Ⅱ),phloroglucinol,and bovine hemoglobin(Hb) chosen as samples were successfully detected by this developed method.The analytical characteristics of the system for the analytes determination including linear ranges,correlation coefficients, limits of detection combined with FI analysis were studied. 展开更多
关键词 CHEMILUMINESCENCE flow-injection analysis Ferrate(Ⅵ)
下载PDF
上一页 1 2 97 下一页 到第
使用帮助 返回顶部