Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels wi...Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels with a width of 1.3 mm and a height of 1.1 mm.The evaporator and condenser sections were 25 and 50 mm long,respectively,and the adiabatic section in between was 75mmlong.Using a plastic 3D printer and semi-transparent filament made from acrylonitrile butadiene styrene,the serpentine channel was printed directly onto a thin polycarbonate sheet to form the PHP.The PHP was charged with hydrofluoroether-7100.In the experiments,the evaporator section was heated,and the condenser section was cooled using high-temperature and low-temperature thermostatic baths,respectively.Flow patterns of the working fluid were obtained with temperature distributions of the PHP.A mathematical model was developed to analyze the flow patterns.Themerged liquid slugs were observed in every two channels,and their oscillation characteristics were found to be approximately the same in time and space.It was also found that the oscillations of the merged liquid slugs became slower,but the heat transfer rate of the PHP increased with a decrease in the filling ratio of the working fluid.This is because vapor condensation was enhanced in vapor plugs as the filling ratio decreased.However,the filling ratio had a lower limit,and the heat transfer rate was maximum when the filling ratio was 40.6%in the present experimental range.展开更多
Understanding of the dynamic particulate flow structures within a dense gas-fly ash pneumatic conveyor must be improved in order to better aid its design guidance.The complex pulsatile movement of the gas-fly ash mixt...Understanding of the dynamic particulate flow structures within a dense gas-fly ash pneumatic conveyor must be improved in order to better aid its design guidance.The complex pulsatile movement of the gas-fly ash mixture dominates the flow performance within the pipeline,and historically,non-invasive measurement devices such as the electrical capacitance tomography(ECT) were often used to sufficiently capture the flow dynamics.However,inadequate studies have been conducted on the pulsatile flow phenomenon,which directly relate to the gas-fly ash two-phase flow performance.This paper aims to investigate the pulsatile flows using an ECT device.Initially,pulsatile flow patterns under various experimental conditions were obtained through ECT.Pulses within a flow were then characterised into pulse growth and decay segments,which represent the superficial fluidisation and deaeration processes during conveying.Subsequently,structural and statistical analyses were performed on the pulse growth and decay segments.Results suggested that the increasing air mass flow rate led to the decrease of the superficial fluidisation/deaeration magnitude,however,the increase of the superficial fluidisation/deaeration durations.Also,the air mass flow rate was indicated as the dominant factor in determining the pulsing statistical parameters.This research provides fundamental insights for further modelling the dense fly ash pneumatic flows.展开更多
基金supported by JSPS KAKENHI Grant Number 22K03947.
文摘Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels with a width of 1.3 mm and a height of 1.1 mm.The evaporator and condenser sections were 25 and 50 mm long,respectively,and the adiabatic section in between was 75mmlong.Using a plastic 3D printer and semi-transparent filament made from acrylonitrile butadiene styrene,the serpentine channel was printed directly onto a thin polycarbonate sheet to form the PHP.The PHP was charged with hydrofluoroether-7100.In the experiments,the evaporator section was heated,and the condenser section was cooled using high-temperature and low-temperature thermostatic baths,respectively.Flow patterns of the working fluid were obtained with temperature distributions of the PHP.A mathematical model was developed to analyze the flow patterns.Themerged liquid slugs were observed in every two channels,and their oscillation characteristics were found to be approximately the same in time and space.It was also found that the oscillations of the merged liquid slugs became slower,but the heat transfer rate of the PHP increased with a decrease in the filling ratio of the working fluid.This is because vapor condensation was enhanced in vapor plugs as the filling ratio decreased.However,the filling ratio had a lower limit,and the heat transfer rate was maximum when the filling ratio was 40.6%in the present experimental range.
文摘Understanding of the dynamic particulate flow structures within a dense gas-fly ash pneumatic conveyor must be improved in order to better aid its design guidance.The complex pulsatile movement of the gas-fly ash mixture dominates the flow performance within the pipeline,and historically,non-invasive measurement devices such as the electrical capacitance tomography(ECT) were often used to sufficiently capture the flow dynamics.However,inadequate studies have been conducted on the pulsatile flow phenomenon,which directly relate to the gas-fly ash two-phase flow performance.This paper aims to investigate the pulsatile flows using an ECT device.Initially,pulsatile flow patterns under various experimental conditions were obtained through ECT.Pulses within a flow were then characterised into pulse growth and decay segments,which represent the superficial fluidisation and deaeration processes during conveying.Subsequently,structural and statistical analyses were performed on the pulse growth and decay segments.Results suggested that the increasing air mass flow rate led to the decrease of the superficial fluidisation/deaeration magnitude,however,the increase of the superficial fluidisation/deaeration durations.Also,the air mass flow rate was indicated as the dominant factor in determining the pulsing statistical parameters.This research provides fundamental insights for further modelling the dense fly ash pneumatic flows.