Flow-injection chemiluminescence determination of tryptophan using galangin-potassium permanganate-polyphosphoric acid system 被引量:2
1
作者 Hui Chen Li Li Min Zhou Yong Jun Ma 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第2期203-206,共4页
A high sensitive flow-injection chemiluminescence (FI-CL) method for the determination of tryptophan has been developed. The method is based on the chemiluminescence reaction of galangin-potassium permanganate-trypt... A high sensitive flow-injection chemiluminescence (FI-CL) method for the determination of tryptophan has been developed. The method is based on the chemiluminescence reaction of galangin-potassium permanganate-tryptophan in polyphosphoric acid (PPA) media. Under the optimized conditions, tryptophan was determined in the range 0.05-10 μg/mL with the detection limit (3tr) of 5.0 × 10^-3 μg/mL. The relative standard deviation (RSD) was 1.0% for 11 replicate determinations of 1.0 μg/mL tryptophan. Three synthetic samples were determined selectively with recoveries in the range from 99.6% to 102.0% in the presence of other amino acids. 展开更多
关键词 chemiluminescence flow-injection GALANGIN Potassium permanganate TRYPTOPHAN
下载PDF
Flow-Injection Enhanced Chemiluminescence Method for Determination of Penicillamine 被引量:1
2
作者 李桂芝 刘永明 《Journal of Rare Earths》 SCIE EI CAS CSCD 2007年第S2期221-223,共3页
A new flow-injection procedure has been developed for the determination of penicillamine based on the enhancement of the chemiluminescence(CL) reaction of the penicillamine-cerium(Ⅳ)-hydrocortisone system. The method... A new flow-injection procedure has been developed for the determination of penicillamine based on the enhancement of the chemiluminescence(CL) reaction of the penicillamine-cerium(Ⅳ)-hydrocortisone system. The method was simple, selective and sensitive with a detection limit of 6.2×10-5 mol·L-1(S/N=3). It was applicable to the determination of penicillamine in the concentration range of 2×10-6~5×10-4 mol·L-1. The method was successfully applied to the determination of penicillamine in tablets. The relative standard deviation (RSD) was 1.42% (n=7) and the recovery was 97%~103% (n=4). 展开更多
关键词 PENICILLAMINE chemiluminescence flow-injection cerium(Ⅳ) hydrocortisone rare earths
下载PDF
Simultaneous Determination of Gold and Platinum by Double Artificial Neural Network Analysis with Flow-injection Chemiluminescence 被引量:1
3
作者 Ming Yang LIU Hai Tao ZHANG Jun Feng LI Shu Gui CHEN Hong Yan WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第10期1343-1346,共4页
A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simula... A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simulated mixed samples, without the boring process. 展开更多
关键词 Double artificial neural networks flow-injection chemiluminescence simultaneous determination gold and platinum.
下载PDF
DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
4
作者 唐玉海 韩小年 +2 位作者 于春玲 孙媛媛 姚宏 《Journal of Pharmaceutical Analysis》 SCIE CAS 2006年第2期136-138,共3页
Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can s... Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can sensitize obviously the chemiluminesence (CL) intensity of the reaction of luminol with KIO_4, the sensitized CL intensity is proportional to the concentration of tetracycline and oxytetracycline. So, a new flow-injection CL method has been developed. The optimum chemical conditions for the CL reaction were investigated. Results Under the optimized conditions (KIO_ 4 concentration: 1.0×10 -5 mol/L; NaOH concentration: 0.1 mol/L; luminol concentration: 1.0×10 -4mol/L), tetracycline and oxytetracycline were determined. The linear range of the working curves was 1.0×10 -7 - 1.0×10 -4g/mL, the detection limits was 1.0×10 -8g/mL and 1.1×10 -8g/mL, and the relative standard deviation was 2.6% (C_S=1.0×10 -6g/mL; n=11) and 2.0% (C_S=1.0×10 -6g/mL; n=11) respectively. Conclusion The method is simple, rapid, and sensitive, and it has been successfully applied to the the determination of tetracycline and oxytetracycline tablets, the mean recoveries being 99.7% and 98.8% respectively. 展开更多
关键词 flow-injection chemiluminescence TETRACYCLINE OXYTETRACYCLINE
下载PDF
Flow-injection Chemiluminescence Determination of Trace Calf Thymus DNA
5
作者 Min ZHOU, Yong Jun MA, Xiao Yong JIN, Xiu Lan TENG, Zi Yu ZHANG,Hui CHENInstitute of Chemistry, Northwest Normal University, Lanzhou 730070 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第10期1051-1053,共3页
A flow injection procedure for the determination of calf thymus DMA (CT DNA) over the range 2.1x10-6;.1x10-1 B.g mL-1 is described, based on measurement of the enhanced chemiluminescence emission of rhodamine B-Ce... A flow injection procedure for the determination of calf thymus DMA (CT DNA) over the range 2.1x10-6;.1x10-1 B.g mL-1 is described, based on measurement of the enhanced chemiluminescence emission of rhodamine B-Ce(IV) system, activated by imidazole-HCl buffer solution. This method is highly sensitive, with the linearity range broadened to five orders of magnitude. It has been applied to determine CT DNA in synthetic sample with satisfactory results. 展开更多
关键词 chemiluminescence flow-injection calf thymus DNA IMIDAZOLE rhodamine B.
下载PDF
Flow-injection-enhanced chemiluminescence method for the determination of three β-blockers
6
作者 Li-Juan Wang1,2,Yu-Hai Tang1,Bao-Ping Li,Hong-Lang Liu1,Jing-Feng Yi11. Institute of Analytical Sciences,School of Sciences 2. Medical School,Xi’an Jiaotong University,Xi’an 710061,China. 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第2期91-96,共6页
Objective To develop a rapid,simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol,atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system ... Objective To develop a rapid,simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol,atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL,1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL,respectively,with the detection limits of 5.0×10-8g/mL,7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3),respectively,and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol,atenolol and propranolol were 3.57%,2.21% and 2.26%,respectively. Conclusion The developed method is sensitive,accurate,rapid and of low cost. And it can be applied to determine bisoprolol,atenolol and propranolol in pharmaceutical preparations. 展开更多
关键词 flow-injection chemiluminescence Β-BLOCKER
下载PDF
Electrogeneration of ferrate (Ⅵ) in low concentration NaOH solution for flow-injection-chemiluminescence detection
7
作者 Hui Jing Zhang Yong Gang Hu +1 位作者 Yong Qian Wang Jie Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第8期951-954,共4页
The possibility of direct analytical applications of ferrate(Ⅵ) solution,which was freshly electrogenerated in low-concentration NaOH electrolyte,was studied by a flow-injection-chemiluminescence(FI-CL) system.It... The possibility of direct analytical applications of ferrate(Ⅵ) solution,which was freshly electrogenerated in low-concentration NaOH electrolyte,was studied by a flow-injection-chemiluminescence(FI-CL) system.It was found that some inorganic ions, organic molecule and biomolecule could enhance the chemiluminescence emission caused by ferrate(Ⅵ)-luminol reaction.V(Ⅴ), Ca(Ⅱ),Mg(Ⅱ),phloroglucinol,and bovine hemoglobin(Hb) chosen as samples were successfully detected by this developed method.The analytical characteristics of the system for the analytes determination including linear ranges,correlation coefficients, limits of detection combined with FI analysis were studied. 展开更多
关键词 chemiluminescence flow-injection analysis Ferrate(Ⅵ)
下载PDF
Flow-injection Chemiluminescence Determination of Catecholamines
8
作者 Huang, JC Zhang, CX Zhang, ZJ 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第9期843-845,共3页
A flow injection chemiluminescence (CL) method for the determination of catecholamines is described which is based on their inhibition of the intensity of CL from the luminol-hypochlorite system The hypochlorite was e... A flow injection chemiluminescence (CL) method for the determination of catecholamines is described which is based on their inhibition of the intensity of CL from the luminol-hypochlorite system The hypochlorite was electrogenerated on-line by a constant current electrolysis, resulting in the elimination of the instability of the hypochlorite solution prepared from a commercial reagent of sodium hypochlorite. The detection limits are 0.6 ng/ml for dopamine, 0.8 ng/ml for adrenaline and isoprenaline. The proposed method has been successfully applied to the determination of catecholamines in pharmaceutical injections. 展开更多
关键词 flow-injection chemiluminescence CATECHOLAMINE LUMINOL ELECTROLYSIS
全文增补中
Chemiluminescence detection of permanganate index (COD_(Mn)) by a luminol-KMnO_4 based reaction 被引量:15
9
作者 TIAN Jinjun HU Yonggang ZHANG Jie 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第2期252-256,共5页
A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol... A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results. 展开更多
关键词 flow-injection chemiluminescence permanganate index (CODMn) luminol-KMnO4
下载PDF
Chemiluminescence Determination of Molybdenum by on-Line Reduction with a Flow Injection System 被引量:4
10
作者 Zhi Jia ZHU (Experimental Center, Hebei Normal University, Shijiazhuang 050016) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第5期427-430,共4页
The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination o... The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples. 展开更多
关键词 chemiluminescence analysis reductant flow-injection MOLYBDENUM LUCIGENIN
下载PDF
Luminol-potassium permanganate chemiluminescence system for the determination of three anthracycline antibiotics
11
作者 Hong-Ling Yu,Yu-Hai Tang,Hai-Yan Lü,Jing-Feng Yi Institute of Analytical Sciences,School of Sciences,Xi’an Jiaotong University,Xi’an 710061,China. 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第1期20-24,共5页
Objective To establish a flow-injection chemiluminescence method for the determination of doxorubicin,epirubicin and mitoxantrone and study its reaction mechanism.Methods In alkaline medium,chemiluminescence of lumino... Objective To establish a flow-injection chemiluminescence method for the determination of doxorubicin,epirubicin and mitoxantrone and study its reaction mechanism.Methods In alkaline medium,chemiluminescence of luminol-potassium permanganate system could be inhibited obviously by anthracycline antibiotics.Combined with flow-injection technique,a new chemiluminescence method for determining the anthracycline antibiotics was set up.The chemiluminescence mechanism of the luminol-potassium permanganate system was also discussed.Results Under optimal conditions,the good linear ranges of doxorubicin,epirubicin and mitoxantrone were 5.0×10-9-1.0×10-6g/mL,1.0×10-9-1.0×10-5g/mL and 3×10-9-1.0×10-6g/mL,respectively.The detection limits of doxorubicin,epirubicin and mitoxantrone were 3.0×10-9g/mL,5.0×10-8g/mL and 2.0×10-9g/mL,respectively.During eleven repeated inter-day and intra-day precision tests of 1.0×10-6g/mL samples,the relative standard deviations corresponded to reference values of 3.0%,2.8% and 2.1%.Conclusion The developed method is sensitive,accurate,rapid and of low cost.It can be applied to determine doxorubicin hydrochloride,epirubicin hydrochloride and mitoxantrone hydrochloride in injection preparations. 展开更多
关键词 flow-injection chemiluminescence anthracycline antibiotics
下载PDF
Determination of Biotin in Pharmaceutical Formulations by Potassium Permanganate-luminol-CdTe Nanoparticles Chemiluminescence System
12
作者 TRAORE Zoumana Sékou SU Xing-guang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第4期604-608,共5页
A sensitive flow-injection chemiluminescence method was developed for the determination of biotin in the pharmaceutical formulations.The affinity between avidin and biotin was used to adsorb biotin on the polystyrene,... A sensitive flow-injection chemiluminescence method was developed for the determination of biotin in the pharmaceutical formulations.The affinity between avidin and biotin was used to adsorb biotin on the polystyrene,with subsequent quantification of biotin based on its ability to enhance the chemiluminescence(CL) signal generated by the redox reaction of potassium permanganate-luminol-CdTe nanoparticles CL system.The investigations prove that apart from 3-aminophthalate,the CdTe quantum dots(QDs) play both catalytic and emitter roles.Under optimum conditions,the linear range for the determination of biotin was 0.01―25 ng/mL with a detection limit of 7.3×10-3 ng/mL(S/N=3).The relative standard deviation of 5 ng/L biotin was 2.06%(n=7).The proposed method was used to determine the biotin concentration in the pharmaceutical formulations and the recovery was between 96.4% and 104%.The proposed method is simple,convenient,rapid and sensitive. 展开更多
关键词 flow-injection chemiluminescence BIOTIN CdTe nanoparticle
下载PDF
Flow Injection Determination of Tramadol Based on Its Sensitizing Effect on the Chemiluminescent Reaction of Permanganate-Sulfite 被引量:1
13
作者 Xun Yao Jingkai Zhang Jianguo Li 《American Journal of Analytical Chemistry》 2011年第7期768-775,共8页
In this paper, a novel chemiluminescence (CL) method for the determination of tramadol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite an... In this paper, a novel chemiluminescence (CL) method for the determination of tramadol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite and acidic KMnO4. A mechanism for the CL reaction has been proposed on the basis of fluorescent and CL spectra. Under the optimized conditions, the proposed method allows the measurement of tramadol hydrochloride over the range of 0.04 - 4 ?g/mLwith a correlation coefficient of 0.9995 (n = 8) and a detection limit of 0.01 ?g/mL (3σ), and the relative standard deviation for 2.0 ?g/mL tramadol (n = 11) is 2.1%. The utility of this method was demonstrated by determining tramadol hydrochloride in tablets and injections. 展开更多
关键词 chemiluminescence TRAMADOL HYDROCHLORIDE KMNO4 Sodium SULFITE flow-injection Analysis
下载PDF
Flow-injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anion-exchange Resin
14
作者 张四纯 周国俊 鞠熀先 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第10期1049-1054,共6页
A novel chemiluminescence (CL) sensor for the determination of gallic acid combined with flow injection analysis was developed by electrostatically immobilizing luminol and periodate on anion-exchange resins respectiv... A novel chemiluminescence (CL) sensor for the determination of gallic acid combined with flow injection analysis was developed by electrostatically immobilizing luminol and periodate on anion-exchange resins respectively. Gallic acid was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The possible reaction mechanism of the CL system was suggested and discussed. The response of the sensor to gallic acid concentration was linear over the range of 8.0×10 -9-1.0×10 -6 mol/L with a detection limit of 6.5×10 -9 mol/L (3σ). The relative standard deviation (RSD) for 7 repetitive determinations of gallic acid (1.0×10 -7 mol/L) was 1.8%. The sensor could be used for over 400 times determination with a good reproducibility. 展开更多
关键词 chemiluminescence sensor gallic acid LUMINOL PERIODATE flow-injection analysis
原文传递
A Study on the Interaction of the DAS-K with Bovine Serum Albumin by On-line Ultrafiltration and Chemiluminescence
15
作者 张琰图 章竹君 孙永华 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2006年第12期1777-1783,共7页
Potassium dehydroandrographolide succinate (DAS-K) has antibacterial and antiviral effects. It has been used widely for the treatment of virus pneumonia, malaria and respiratory infections. In this work, a novel flo... Potassium dehydroandrographolide succinate (DAS-K) has antibacterial and antiviral effects. It has been used widely for the treatment of virus pneumonia, malaria and respiratory infections. In this work, a novel flow-injection chemiluminescence (CL) method for the determination of DAS-K was proposed. The method is based on the reaction between DAS-K and hexacyanoferrate(III) in alkaline solution to give weak CL signal, which is enhanced by rhodamine B. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. Under the optimum conditions, the concentration of DAS-K is proportional to the CL intensity in the range of 0.1-80 μmol·L^-1 with a detection limit of 0.05 μmol·L^-1. The interaction of the DAS-K with bovine serum albumin by on-line ultrafiltration and flow-injection chemiluminescence was studied. The concentrations of unbound DAS-K from ultra filter tube were determined by the flow-injection CL method. The binding parameters were estimated by the Scatchard plot and Klotz plot. The proposed system proved that FIA-CL coupled with on-line ultrafiltration sampling was a fast and simple technique for the study of drug-protein interaction. 展开更多
关键词 chemiluminescence ultrafiltration sampling flow-injection analysis drug-protein interaction potassium dehydroandrograpolide succinate bovine serum albumin