期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Effect of flue gas recirculation technology on soot and NO formation in the biomass pyrolysis-combustion system
1
作者 YANG Yu ZHENG Shu +2 位作者 HE YuZhen LIU Hao LU Qiang 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第4期945-955,共11页
Pyrolysis of biomass followed by combustion of pyrolytic vapors to replace fossil fuels is an economic low-carbon solution.However,the polycyclic aromatic hydrocarbons and N-containing species in biomass pyrolysis vap... Pyrolysis of biomass followed by combustion of pyrolytic vapors to replace fossil fuels is an economic low-carbon solution.However,the polycyclic aromatic hydrocarbons and N-containing species in biomass pyrolysis vapors result in the soot and NO emissions.The flue gas recirculation(FGR)technology,having the potential to reduce the soot and NO emissions,was introduced to the biomass pyrolysis-combustion system.In addition,it was numerically studied by simulating the biomass pyrolysis vapors based co-flow diffusion flames with CO_(2)addition.Both the experimental and simulated results showed that the FGR had significant suppression effects on the soot formation.When the FGR ratio(i.e.,CO_(2)addition ratio)increased from 0%to 15%,the experimental and simulated soot volume fraction respectively decreased by 32%and 21%,which verified the models used in this study.The decrease in OH concentration caused by the CO_(2)addition was responsible for the decrease in the decomposition rate of A2(A2+OH=A2–+H_(2)O).Hence,more benzo(ghi)fluoranthene(BGHIF)was generated through A1C_(2)H–+A2→BGHIF+H_(2)+H,leading to the increase in inception rate.The decrease in benzo(a)pyrene(BAPYR)concentration was the major factor in the decrease in soot condensation rate.Moreover,the decrease in the C_(2)H_(2) and OH concentrations was responsible for the decrease in the HACA surface growth rate.Furthermore,the simulated results showed that the NO concentration decreased by 0.4%when the content of CO_(2)was increased by 1 vol.%.The decrease in OH concentration suppressed the NO formation via decreasing reaction rates of N+OH=NO+H and HNO+OH=NO+H_(2)O and enhanced the NO consumption via increasing reaction rate of HO_(2)+NO=NO_(2)+OH. 展开更多
关键词 biomass pyrolysis vapors biomass pyrolysis-combustion system flue gas recirculation NO emission soot reduction
原文传递
Influence of Recirculated Flue Gas Distribution on Combustion and NOx Formation Characteristics in S-CO_(2) Coal-fired Boiler
2
作者 Peipei WANG Mingyan GU +3 位作者 Yao FANG Boyu JIANG Mingming WANG Ping CHEN 《Mechanical Engineering Science》 2021年第2期42-52,共11页
Supercritical carbon dioxide(S-CO_(2))Brayton power cycle power generation technology,has attracted more and more scholars'attention in recent years because of its advantages of high efficiency and flexibility.Com... Supercritical carbon dioxide(S-CO_(2))Brayton power cycle power generation technology,has attracted more and more scholars'attention in recent years because of its advantages of high efficiency and flexibility.Compared with conventional steam boilers,S-CO_(2) has different heat transfer characteristics,it is easy to cause the temperature of the cooling wall of the boiler to rise,which leads to higher combustion gas temperature in the furnace,higher NOX generation concentration.The adoption of flue gas recirculation has a significance impact on the combustion process of pulverized coal in the boiler,and it is the most effective ways to reduce the emission of NOX and the combustion temperature in the boiler.This paper takes 1000MW S-CO_(2) T-type coal-fired boiler as the research target to investigate the combustion and NOX generation characteristics of S-CO_(2) coal-fired boilers under flue gas recirculation condition,the influence of recirculated flue gas distribution along the furnace height on the characteristics of NOX formation and the combustion of pulverized coal.The results show that the recirculated flue gas distribution has the great impact on the concentration of NOX at the boiler outlet.When the bottom recirculation flue gas rate is gradually increased,the average temperature of the lower boiler decreases and the average temperature of the upper boiler increases slightly;The concentration of NOx at the furnace outlet increases. 展开更多
关键词 S-CO_(2)boiler Pulverized coal combustion NOX emission flue gas recirculation Recirculated flue gas distribution
下载PDF
Pressure Analysis of the Initial Process of Diffusion Combustion Surge in a 350 kW Gas Boiler
3
作者 GAO Han ZHU Tong PAN Deng 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第2期582-589,共8页
In order to meet the increasingly stringent requirements for nitrogen oxides(NOx)emissions from gas boilers,flue gas recirculation(FGR)technology is commonly used to achieve ultra-low NOx emissions.However,under some ... In order to meet the increasingly stringent requirements for nitrogen oxides(NOx)emissions from gas boilers,flue gas recirculation(FGR)technology is commonly used to achieve ultra-low NOx emissions.However,under some ultra-low NOx combustion conditions with FGR,a surge phenomenon occurs in the boiler,which causes a flameout and should be avoided.In this study,the diffusion combustion surge of gas boiler with a rated power of 350 k W and equipped with FGR device was investigated.Pressure characteristic analysis results of the initial process of combustion surge showed that the high-frequency component of pressure is closely related to combustion stability and its change can provide reference for the occurrence of surge.Besides,the initial process of surge was analyzed by wavelet packet entropy method.Results indicated that the wavelet packet entropy of pressure signals could effectively reflect the stability of combustion in the furnace,and it could also be used to study the occurrence of surge. 展开更多
关键词 diffusion combustion flue gas recirculation wavelet packet entropy SURGE gas boiler
原文传递
Application of Response Surface Methodology for Analysis of Reheat Steam Temperatures in a Double Reheat Coal-Fired Boiler
4
作者 ZHANG Jian XU Wei +3 位作者 ZHANG Zhongxiao FAN Haojie WU Xiaojiang DONG Jiancong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第6期2203-2215,共13页
For the improvement of reheat steam quality and performance of double reheat coal-fired utility boiler under wide load operation, a variety of temperature regulation ways were utilized to adjust the energy distributio... For the improvement of reheat steam quality and performance of double reheat coal-fired utility boiler under wide load operation, a variety of temperature regulation ways were utilized to adjust the energy distribution between different heating surfaces. In this paper, thermodynamic calculation based on the fundamental heat transfer theory was conducted for the analysis of temperature regulation strategy effects to steam temperature. In consideration of the specific overlapping heating surface arrangement, the compartment model was adopted to solve this problem. Response surface methodology(RSM) was used to analysis the effect of each temperature regulating variables on the steam temperature and boiler efficiency;then the polynomial model was fitted to predict the primary and secondary steam temperature simultaneously. Results showed that the flue gas recirculation rate has a relatively significant influence on the steam temperature, the maximum temperature deviation between fitting value and calculation value is 3.85℃ in 75% THA;the quadratic model can well predict the steam temperature under different operation conditions in wide load change. The variation of flue gas baffle has a significant influence on the boiler efficiency, compared to the flue gas recirculation and angle of burner oscillation. The influence of various factors on the reheat steam temperature is flue gas baffle > flue gas recirculation > angle of burner oscillation. 展开更多
关键词 reheat steam temperature flue gas baffle flue gas recirculation response surface methodology coal-fired boiler
原文传递
上一页 1 下一页 到第