[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PP...[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PPR.[Methods]Soluble N protein and NH fusion protein were successfully obtained in an Escherichia coli expression system by optimizing E.coli codon and expression conditions.Furthermore,based on purified soluble N protein and NH fusion protein,a double-antigen sandwich time-resolved fluorescence immunoassay method for detection of peste des petits ruminants virus(PPRV)was established.[Results]The method has high sensitivity and specificity and can specifically detect the antibody against PPRV in sheep serum,and it has no cross reaction with other related diseases.The method was used to detect 292 clinical samples,and compared with French IDVET competition ELISA kit.The coincidence rates of positive samples and negative samples from the two kinds of test kits were 92.47%and 97.26%,respectively,and the overall coincidence rate was 94.86%.The intra-group and inter-group coefficients of variation in the repeatability test were less than 10%.[Conclusions]Compared with the traditional ELISA method,the double-antigen sandwich time-resolved fluorescence immunoassay for detection of PPRV has equivalent sensitivity and specificity,and simple and rapid operation,and thus high application and popularization value.展开更多
A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed...A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed an IC50 value of 23.33 ng/mL with a limit of detection of 13.12 ng/mL for AFB1. The cross-reactivities of AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 with the antibody were 100%, 65.7%, 143%, 23.5%, 111.4%, and 2%, respectively. The group-specificity of anti-AFB1mAb indicated that the FPIA could potentially be used in a screening method for the detection of total AFs, albeit not AFG2 and AFM2. The total time required for analyzing 96 samples in one microplate was less than 5 rain. This study demonstrates the potential usefulness of the FPIA as a rapid and simple technique for monitoring AFs.展开更多
N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine ...N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine the free morphine in urine of abusers. The detection limit was calculated to be 40 ng/mL. Simulated urine samples were analyzed with good recoveries, which showed the feasibility of its application in specific morphine determination in urine of morphine abusers.展开更多
A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process ...A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%.展开更多
Estrone has been identified as a potential endocrine-disrupting chemical (EDC)[1]. Estrone is usually quantified by gas chromatography-mass spectrometry (GC-MS), GC-MS/MS, high performance liquid chromatography (...Estrone has been identified as a potential endocrine-disrupting chemical (EDC)[1]. Estrone is usually quantified by gas chromatography-mass spectrometry (GC-MS), GC-MS/MS, high performance liquid chromatography (HPLC), HPLC- MS, and HPLC-MS/MS, etc.[2-3]. Meanwhile, several immunoassays based on radioimmunoassay, enzyme linked immunosorbent assay (ELISA) or chemiluminescence immunoassay (CLIA) for determination of estrone in real samples have been developed[2'4]. Although these methods are sensitive, they need multistage separation and are thus time-consuming and laborious. A very promising way for the simplification of immunoassays for routine applications is a shift from heterogeneous methods (with separation) to homogeneous assays (without separation)[5]. Fluorescence polarization immunoassay (FPIA) is one of the homogeneous techniques that meets the requirements of a simple, reliable, fast, and cost-effective analysis[6]. Therefore, the present study is focused on the development of FPIA in order to analyze estrone based on antibody production.展开更多
Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and eval...Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and evaluate the assay.Results: The linear range of the CLIA method was 0.51~40 mg/L (Y=1.02X+0.44, r=0.995). The intra and inter CV (coefficient variance) of CLIA were 3.20% and 3.57%, respectively. The average recovery rate was 102.3%. This method was free from interference by brilirubin (<200 μmol/L), hemoglobin (<10 g/L), and triglycerides (<15 mmol/L). Conclusion: This method is simple, convenient and precise for clinical pharmacokinetics study oftheophylline.展开更多
Breast cancer is the second leading cause of cancerrelated deaths in women worldwide;a prime cancer biomarker to aid in the diagnosis, directed treatment, clinical management, and reoccurrence of this cancer is a MUC1...Breast cancer is the second leading cause of cancerrelated deaths in women worldwide;a prime cancer biomarker to aid in the diagnosis, directed treatment, clinical management, and reoccurrence of this cancer is a MUC1 peptide fragment: cancer antigen 15-3 (CA 15-3). Herein, an immuno-fluorescence assay for CA 15-3 was developed;this ALYGNSA system consists of a protein biolinker (Protein G’) adsorbed onto Poly (methyl methacrylate) (PMMA). The unique interaction of Protein G’ with PMMA, a thermo-plastic polymer has been demonstrated to improve human IgG capture antibody alignment/ orientation and result in greater assay sensitivity. Indeed a previous report (HEALTH 1 325 - 329, 2009) on the shed extracellular domain of HER-2/neu revealed a 10-fold increase in sensitivity of the ALYGSNA assay over a control ELISA assay. Results from this ALYGNSA assay study revealed that a 16-fold increase in detection (≤0.94 U/mL) of CA 15-3 was found in comparison to a commercial control ELISA kit (≤15 U/mL). In conclusion, this enhanced sensitivity of the ALYGNSA assay for CA 15-3, may provide insights into the role/function of this biomarker in normal, as well as, breast cancer and other epithelial cancers.展开更多
New reagents for immunofluorescence analysis of carbazole series containing fluorinated β-dicarbonyl fragments and carboxylic substituent groups separated by spacers of different lengths from the light-gathering carb...New reagents for immunofluorescence analysis of carbazole series containing fluorinated β-dicarbonyl fragments and carboxylic substituent groups separated by spacers of different lengths from the light-gathering carbazole scaffold have been developed. The markers in complex with Eu<sup>3+</sup> ions possess stability in the aqueous phase, intense and prolonged luminescence (τ 550 - 570 μs) with characteristic emission maxima in the region of 615 nm and excitation wavelengths in the region of 380 - 390 nm, which distinguishes them from most of the analogs used. In the study of marker conjugation with streptavidin, a reagent containing 4 - 5 europium labeling complexes based on spacer-containing carbazole tetraketone was obtained. The marker-doped silicate nanoparticles exhibit intense and long-lived luminescence in the characteristic region.展开更多
基金Supported by National Key R&D Program for the Prevention and Control of Major Exotic Animal Diseases(2022YFD1800500)National Mutton Sheep Industrial Technology System(CARS39)+2 种基金Key Research and Development Program of Shandong Province(Major Science and Technology Innovation Project)(2021CXGC011306)Scientific Research Project of General Administration of Customs(2024HK033)Scientific Research Project of Jinan Customs(2023JK005).
文摘[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PPR.[Methods]Soluble N protein and NH fusion protein were successfully obtained in an Escherichia coli expression system by optimizing E.coli codon and expression conditions.Furthermore,based on purified soluble N protein and NH fusion protein,a double-antigen sandwich time-resolved fluorescence immunoassay method for detection of peste des petits ruminants virus(PPRV)was established.[Results]The method has high sensitivity and specificity and can specifically detect the antibody against PPRV in sheep serum,and it has no cross reaction with other related diseases.The method was used to detect 292 clinical samples,and compared with French IDVET competition ELISA kit.The coincidence rates of positive samples and negative samples from the two kinds of test kits were 92.47%and 97.26%,respectively,and the overall coincidence rate was 94.86%.The intra-group and inter-group coefficients of variation in the repeatability test were less than 10%.[Conclusions]Compared with the traditional ELISA method,the double-antigen sandwich time-resolved fluorescence immunoassay for detection of PPRV has equivalent sensitivity and specificity,and simple and rapid operation,and thus high application and popularization value.
基金supported by grants from the International Science&Technology Cooperation Program of China(2009DFA32330)the Special Fund for Agro-scientific Research in the Public Interest(No.201203040)
文摘A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed an IC50 value of 23.33 ng/mL with a limit of detection of 13.12 ng/mL for AFB1. The cross-reactivities of AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 with the antibody were 100%, 65.7%, 143%, 23.5%, 111.4%, and 2%, respectively. The group-specificity of anti-AFB1mAb indicated that the FPIA could potentially be used in a screening method for the detection of total AFs, albeit not AFG2 and AFM2. The total time required for analyzing 96 samples in one microplate was less than 5 rain. This study demonstrates the potential usefulness of the FPIA as a rapid and simple technique for monitoring AFs.
文摘N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine the free morphine in urine of abusers. The detection limit was calculated to be 40 ng/mL. Simulated urine samples were analyzed with good recoveries, which showed the feasibility of its application in specific morphine determination in urine of morphine abusers.
基金supported by National Commission of Natural Science Foundation of China.
文摘A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%.
基金supported by Natural Science Foundation of China(U1301214)Guangdong Natural Science Foundation(S2013030013338)+1 种基金the PhD Programs Foundation of Ministry of Education of China(20114404130002)National Department Public Benefit Research Foundation(201003008-08)
文摘Estrone has been identified as a potential endocrine-disrupting chemical (EDC)[1]. Estrone is usually quantified by gas chromatography-mass spectrometry (GC-MS), GC-MS/MS, high performance liquid chromatography (HPLC), HPLC- MS, and HPLC-MS/MS, etc.[2-3]. Meanwhile, several immunoassays based on radioimmunoassay, enzyme linked immunosorbent assay (ELISA) or chemiluminescence immunoassay (CLIA) for determination of estrone in real samples have been developed[2'4]. Although these methods are sensitive, they need multistage separation and are thus time-consuming and laborious. A very promising way for the simplification of immunoassays for routine applications is a shift from heterogeneous methods (with separation) to homogeneous assays (without separation)[5]. Fluorescence polarization immunoassay (FPIA) is one of the homogeneous techniques that meets the requirements of a simple, reliable, fast, and cost-effective analysis[6]. Therefore, the present study is focused on the development of FPIA in order to analyze estrone based on antibody production.
文摘Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and evaluate the assay.Results: The linear range of the CLIA method was 0.51~40 mg/L (Y=1.02X+0.44, r=0.995). The intra and inter CV (coefficient variance) of CLIA were 3.20% and 3.57%, respectively. The average recovery rate was 102.3%. This method was free from interference by brilirubin (<200 μmol/L), hemoglobin (<10 g/L), and triglycerides (<15 mmol/L). Conclusion: This method is simple, convenient and precise for clinical pharmacokinetics study oftheophylline.
文摘Breast cancer is the second leading cause of cancerrelated deaths in women worldwide;a prime cancer biomarker to aid in the diagnosis, directed treatment, clinical management, and reoccurrence of this cancer is a MUC1 peptide fragment: cancer antigen 15-3 (CA 15-3). Herein, an immuno-fluorescence assay for CA 15-3 was developed;this ALYGNSA system consists of a protein biolinker (Protein G’) adsorbed onto Poly (methyl methacrylate) (PMMA). The unique interaction of Protein G’ with PMMA, a thermo-plastic polymer has been demonstrated to improve human IgG capture antibody alignment/ orientation and result in greater assay sensitivity. Indeed a previous report (HEALTH 1 325 - 329, 2009) on the shed extracellular domain of HER-2/neu revealed a 10-fold increase in sensitivity of the ALYGSNA assay over a control ELISA assay. Results from this ALYGNSA assay study revealed that a 16-fold increase in detection (≤0.94 U/mL) of CA 15-3 was found in comparison to a commercial control ELISA kit (≤15 U/mL). In conclusion, this enhanced sensitivity of the ALYGNSA assay for CA 15-3, may provide insights into the role/function of this biomarker in normal, as well as, breast cancer and other epithelial cancers.
文摘New reagents for immunofluorescence analysis of carbazole series containing fluorinated β-dicarbonyl fragments and carboxylic substituent groups separated by spacers of different lengths from the light-gathering carbazole scaffold have been developed. The markers in complex with Eu<sup>3+</sup> ions possess stability in the aqueous phase, intense and prolonged luminescence (τ 550 - 570 μs) with characteristic emission maxima in the region of 615 nm and excitation wavelengths in the region of 380 - 390 nm, which distinguishes them from most of the analogs used. In the study of marker conjugation with streptavidin, a reagent containing 4 - 5 europium labeling complexes based on spacer-containing carbazole tetraketone was obtained. The marker-doped silicate nanoparticles exhibit intense and long-lived luminescence in the characteristic region.