期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
FLUORIMETRIC DETERMINATION OF TETRACYCLINE IN SERUM AND URINE
1
作者 Jing He YANG Hua Bin ZOU +1 位作者 Nian Qin JIE Hong Mei GE Department of Chemistry,Shandong University,Jinan,250100 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第9期727-730,共4页
The Eu-Tetracycline(TC)-TOPO-sodium dodecyl sulfonate(SDS)system was studied,Experiments showed that the maximum fluorescence intensity was obtained in the pH range of 7.5-8.7 and the concentrations of Eu^(a+),TOPO an... The Eu-Tetracycline(TC)-TOPO-sodium dodecyl sulfonate(SDS)system was studied,Experiments showed that the maximum fluorescence intensity was obtained in the pH range of 7.5-8.7 and the concentrations of Eu^(a+),TOPO and SDS are 1.0×10^(-6)mol/L,1.0×10^(-8)mol/L and 1.0×10^(-8)mol/L,respectively,This fluorescence system can be used for the determination of TC in serum and urine,Beer's Law is obeyed in the range of 2.0×10^(-8)mol/L=1.0×10^(-6)mol/L for the concentration of TC. The determination limit is 1.2×10^(-8)mol/L,The composition and the luminescence mechanism were discussed. 展开更多
关键词 TOPO SDS TC fluorimetric determination OF TETRACYCLINE IN SERUM AND URINE Eu
下载PDF
A RAPID FLUORIMETRIC DETERMINATION OF TYROSINE IN SERUM BY THE REACTION WITH CERIUM (Ⅳ)
2
作者 Nian Qin JIE, Jing He YANG and Xue Fang LIU Department of chemistry, Shandong University, Jinan, 250100 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第5期435-438,共4页
A fluorimetric method for the determination of tyrosine in serum was proposed. The fluoriscence intensity is a linear function of tyrosine content in the range 0-1. 44ug/ml. The percentage of recovery was satisfactory.
关键词 Th IV A RAPID fluorimetric determination OF TYROSINE IN SERUM BY THE REACTION WITH CERIUM
下载PDF
DEHYDRATION AND FLUORIMETRIC DETERMINATION OF ADRIAMYCIN
3
作者 Yi Bzing ZHAO Xue Fang MA Xiang Qun GUO Jin Gou XU Guo Zhen CHEN Department of Chemistry,Xiamen University,Xiamen 361005,CHINA 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第12期1001-1002,共2页
A dehydration reaction of ADM was carried out in sulfuric acid solution and an intensely fluorescent product was formed.This reaction was applied to the determination of ADM in body fluids.
关键词 ADH DEHYDRATION AND fluorimetric determination OF ADRIAMYCIN
下载PDF
Fluorimetric determination of methylmercury with 2, 3-dimercaptonaphthalene
4
作者 LI Hua\|bin, PENG An, XU Xiang\|rong, WANG Wen\|hua (SKLEAC, Research Center for Eco\|Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2000年第S1期108-108,共1页
Methylmercury is the most toxic one among the mercury species. Many methods including atomic absorption spectrometry, atomic emission spectrometry, atomic fluorescence spectrometry, gas chromatography, high\|performa... Methylmercury is the most toxic one among the mercury species. Many methods including atomic absorption spectrometry, atomic emission spectrometry, atomic fluorescence spectrometry, gas chromatography, high\|performance liquid chromatography, ion chromatography, and capillary electrophoresis, have been published for the determination of methylmercury. These methods have been reviewed (Li, 1997; 1993; Niu, 1991). These methods require expensive equipment and highly qualified analysts. Although fluorimetric method is sensitive, inexpensive, easy to operate, no data about determination of methylmercury by fluorimetry can be found in the literature. In order to obtain a better method for the determination of methylmercury by fluorimetry, several reagents such as 8\| hydroxyquinoline, 8\|aminoquinoline, 8\|mercaptoquinoline, 2,3\| diaminonaphthalene, 2, 3\|dimercaptonaphthalene were tested. The 2, 3\|dimercaptonaphthalene gave better result than the other reagents. Under the optimal conditions, the concentration of 2, 3\| dimercaptonaphthalene was 5.6×10 -5 mol/L and the pH value of the solution was adjusted to 4.0 with acetate buffer solution. The excitation and emission fluorescence wavelengths of 2,3\| dimercaptonaphthalene-methylmercury complex were 512.5 nm and 500 nm(antistokes), respectively. The linear range was 0.3—80 ng/ml and the detection limit was 0.02 ng/ml. The relative standard deviation was 2.6%. The method may be applied to determine methylmercury in environmental samples, and detailed investigation is in progress. 展开更多
关键词 fluorimetric determination of methylmercury with 2
下载PDF
Derivatization Reaction of Carbohydrates with Urea as the Reagent and Fluorimetric Determination of Carbohydrates
5
作者 杨景和 曹西慧 +2 位作者 王敏 吴霞 孙长侠 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第1期51-56,共6页
It is found that in the presence of sulfuric acid carbohydrates condense withurea to afford the condensation products, which emit fluorescence. Under optimum conditions, thefluorescence intensities of system are propo... It is found that in the presence of sulfuric acid carbohydrates condense withurea to afford the condensation products, which emit fluorescence. Under optimum conditions, thefluorescence intensities of system are proportional to the concentrations of carbohydrates. Based onthis linear relationship, quantitative determination of kinds of carbohydrates has been made. Amongall the carbohydrates tested, the sensitivity of α-rhamnose is the highest and its limits ofdetection reaches 3. 5 * 10^(-8) mol/L. So α-rhamnose can be selectively determined in the presenceof other carbohydrates. A interaction mechanism is also discussed. 展开更多
关键词 CARBOHYDRATE UREA derivatization reaction fluorimetric determination
原文传递